| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.6 LAdmitted-Finance 32 1089 KALAMASSERY CHANGAMPUZHA NAGAR COCHIN ERNAKULAM KERALA 682033 | ERNAKULAM | KERALA | 682033 | L1 | Admitted-Finance | |
| 2 | L2₹62.3 L+₹7.7 L (14.0%)Admitted-Finance 2ND FLOOR KALOOR BUSSTAND COMPLEX BUS STAND COMPLEX KALOOR BUSSTAND COMPLEX ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L2 | Admitted-Finance | |
| 3 | L3₹65.3 L+₹10.7 L (19.5%)Admitted-Finance 65 905 SEBASTIAN ROAD KALOOR KALOOR ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | L3 | Admitted-Finance | |
| 4 | Rejected-Technical | - | Rejected-Technical Not submitted the proof of completion or Satisfactory performance certificate valid Grade B contract license issued by KSEBL undertaking for mobilization of man power Financial Statements IT Returns Dully filled signed and seal affixed as per TD |
| Sl No | Description | Qty | Unit | Geresh Electricals Private Limited L1 | SMEC AUTOMATION PVT.LTD L2 | POZITIVE POWER INDIA PRIVATE LIMITED L3 |
|---|---|---|---|---|---|---|
| 1.00 | Replacing of inspection lamp bulb and holder. Details as per sl No 1.1 in BOQ | 200 | Numbers | 10,000 ₹11,800 Lowest | 17,640 ₹20,815.2 | 27,000 ₹31,860 |
| 2.00 | Replacement of tube light fittings.Details as per sl No 1.2 in BOQ | 150 | Numbers | 11,250 ₹13,275 Lowest | 13,230 ₹15,611.4 | 21,750 ₹25,665 |
| 3.00 | Replacement of switches/MCBs for light fittings. Details as per sl No 1.3 in BOQ | 100 | Numbers | 10,000 ₹11,800 Lowest | 13,230 ₹15,611.4 | 12,500 ₹14,750 |
| 4.00 | Installation and charging of new light points (include wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.). Details as per sl No 1.4 in BOQ | 50 | Numbers | 20,000 ₹23,600 | 13,230 ₹15,611.4 Lowest | 1,05,000 ₹1,23,900 |
| 5.00 | Replacement of Street light fittings.Details as per sl No 1.5 in BOQ | 200 | Numbers | 1,00,000 ₹1,18,000 | 61,740 ₹72,853.2 Lowest | 1,64,000 ₹1,93,520 |
| 6.00 | Installation and charging of new street light points (includes wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.).Details as per sl No 1.6 in BOQ | 50 | Numbers | 12,500 ₹14,750 Lowest | 17,640 ₹20,815.2 | 2,09,500 ₹2,47,210 |
| 7.00 | Repair of light fittings (Tube light, HPMV, HPSV, CFL, LED, MH etc.). Details as per sl No 1.7 in BOQ | 100 | Numbers | 2,000 ₹2,360 Lowest | 13,230 ₹15,611.4 | 12,500 ₹14,750 |
| 8.00 | Removal of Ceiling fan, wall mounting fans, pedestal fans etc..Details as per sl No 2.1 in BOQ | 50 | Numbers | 7,500 ₹8,850 Lowest | 17,640 ₹20,815.2 | 21,000 ₹24,780 |
| 9.00 | Repair of Ceiling fan, wall mounting fans, pedestal fans.Details as per sl No 2.2 in BOQ | 25 | Numbers | 3,750 ₹4,425 | 9,922.5 ₹11,708.55 | 3,250 ₹3,835 Lowest |
| 10.00 | Replacement of Ceiling fan, wall mounting fans, pedestal fans. Details as per sl No 2.3 in BOQ | 100 | Numbers | 30,000 ₹35,400 Lowest | 39,690 ₹46,834.2 | 68,000 ₹80,240 |
Tender Value
₹65.5 L
EMD Value
₹1.1 L
Closing Date
27 Oct 2025, 10:30 amClosed
Shri. V A Anil Kumar DGM-Technical (Purchase)
IREL (India) Limited, RED, Udyogamandal
Rate contract for repair and maintenance of Electrical Installation at IREL,RED
2025_IREL_252064_1
IREL/Udyogamandal/25-26/ 36117
Open Tender
Miscellaneous Services
Works
730 days
IREL (India) Limited, RED, Udyogamandal
Details as per tender document
2 documents required · 2 mandatory
₹0
₹1.1 L
Yes
13 Nov 2025
13 Oct 2025
28 Oct 2025
13 Oct 2025
27 Oct 2025
13 Oct 2025
13 Oct 2025 - 25 Oct 2025
Replacing of inspection lamp bulb and holder. Details as per sl No 1.1 in BOQ
Replacement of tube light fittings.Details as per sl No 1.2 in BOQ
Replacement of switches/MCBs for light fittings. Details as per sl No 1.3 in BOQ
Installation and charging of new light points (include wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.). Details as per sl No 1.4 in BOQ
Replacement of Street light fittings.Details as per sl No 1.5 in BOQ
Installation and charging of new street light points (includes wiring (maximum of 10mtr.), providing switches, fixing light fittings supports and light fitting etc.).Details as per sl No 1.6 in BOQ
Repair of light fittings (Tube light, HPMV, HPSV, CFL, LED, MH etc.). Details as per sl No 1.7 in BOQ
Removal of Ceiling fan, wall mounting fans, pedestal fans etc..Details as per sl No 2.1 in BOQ
Repair of Ceiling fan, wall mounting fans, pedestal fans.Details as per sl No 2.2 in BOQ
Replacement of Ceiling fan, wall mounting fans, pedestal fans. Details as per sl No 2.3 in BOQ
Installation and charging of new Ceiling fan/wall mounting fans/ pedestal fans etc. Details as per sl No 2.4 in BOQ
Repair of exhaust fans of different capacity. Details as per sl No 2.5 in BOQ
Replacement of exhaust fans of different capacity.Details as per sl No 2.6 in BOQ
Installation and charging of new exhaust fans of different capacity (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.7 in BOQ
Repair of Tube axial fans/Air circulator/ Man cooler etc. Details as per sl No 2.8 in BOQ
Replacement of Air circulator Man cooler etc. Details as per sl No 2.9 in BOQ
Installation and charging of new Air circulator Man cooler (includes wiring (maximum of 10mtr.), providing switches etc. Details as per sl No 2.10 in BOQ
Air Blowing, cleaning and servicing of PCC/MCC panels. While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 3 in BOQ
Air Blowing, cleaning and servicing of Main Switches, Starters, DBs’ While cleaning any of the damaged component noticed, shall be replaced by contractor (All required spares shall be issued by IREL). Details as per sl No 4 in BOQ
Replacement of contactors.Details as per sl No 5.1 in BOQ
Replacement of over load relay. Details as per sl No 5.2 in BOQ
Replacement of DOL starter. Details as per sl No 5.3 in BOQ
Repair of DOL starter. Details as per sl No 5.4 in BOQ
Installation and charging of DOL starter.Details as per sl No 5.5 in BOQ
Replacement of contactors. Details as per sl No 6.1 in BOQ
Replacement of over load relay. Details as per sl No 6.2 in BOQ
Replacement of star delta timer. Details as per sl No 6.3 in BOQ
Replacement of Star Delta Starter. Details as per sl No 6.4 in BOQ
Repair of Star Delta starter. Details as per sl No 6.5 in BOQ
Installation and charging of Star Delta starter. Details as per sl No 6.6 in BOQ
Repair/replacement of remote switch station. Details as per sl No 7 in BOQ
Installation and charging of remote switch station.Details as per sl No 8 in BOQ
Repair/replacement of float switch control station. Details as per sl No 9 in BOQ
Replacement of float switch. Details as per sl No 10 in BOQ
Installation and charging of float switch control station & float switch (including its cabling). Details as per sl No 11 in BOQ
Repair/replacement of Drives and its programming. Details as per sl No 12 in BOQ
Repair/replacement of Lighting DBs. Details as per sl No 13 in BOQ
Installation and charging of New Lighting DB (Includes cabling, termination, earthing etc. Details as per sl No 14 in BOQ
Repair/replacement of Power DBs’. Details as per sl No 15 in BOQ
Installation and charging of New Power DB (Includes cabling, termination, earthing etc. Details as per sl No 16 in BOQ
32A to 160A. Details as per sl No 17.1 in BOQ
200A to 400A. Details as per sl No 17.2 in BOQ
Replacement of HRC Fuses. Details as per sl No 18 in BOQ
Removal fuse/ isolation of power from electro-mechanical machinery for maintenance work. Details as per sl No 19 in BOQ
Re-positioning fuse to circuit / charging the isolated power from the electro-mechanical machinery after maintenance work. Details as per sl No 20 in BOQ
Installation/Replacement/Repair of MCB/MPCB. Details as per sl No 21 in BOQ
32A to 160A. Details as per sl No 22.1 in BOQ
200A to 400A.Details as per sl No 22.2 in BOQ
630A and above. Details as per sl No 22.3 in BOQ
0.5 HP to 7.5HP.Details as per sl No 23.1 in BOQ
10HP to 30HP. Details as per sl No 23.2 in BOQ
40Hp to 50HP. Details as per sl No 23.3 in BOQ
0.5 HP to 7.5HP. Details as per sl No 24.1 in BOQ
10HP to 30HP. Details as per sl No 24.2 in BOQ
40Hp to 50HP. Details as per sl No 24.3 in BOQ
0.5 HP to 7.5HP. Details as per sl No 25.1 in BOQ
10HP to 30HP. Details as per sl No 25.2 in BOQ
40Hp to 50HP.Details as per sl No 25.3 in BOQ
0.5 HP to 7.5HP. Details as per Sl No 26.1 in BOQ
10HP to 30HP.Details as per Sl No 26.2 in BOQ
40Hp to 50HP.Details as per Sl No 26.3 in BOQ
0.5 HP to 7.5HP. Details as per Sl No 27.1 in BOQ
10HP to 30HP.Details as per Sl No 27.2 in BOQ
40Hp to 50HP.Details as per Sl No 27.3 in BOQ
Checking the conditions of heating coils & switch gears for the furnace/calciner. Details as per Sl No 28 in BOQ
Cleaning, lubricating, and checking of hooks, clamps, Nuts& bolts, wire rope, chain and replacement (if required) of electric hoist. Details as per Sl No 29 in BOQ
Repair the control circuit of the electric hoist. Details as per Sl No 30 in BOQ
Removing of the unused/damaged cable, rolling out the cables, transport to salvage/scrap yard, after weighing, (with in 200mtr inside the company premises). Details as per Sl No 31 in BOQ
Removing of the unused/damaged cable trays, light fixers, starter and frames, MS structural materials etc., Details as per Sl No 32 in BOQ
Disconnect incomer and outgoing power cable from the Old/damaged PCC/MCC/ MCB-DB panel, Removing the Old/damaged PCC/MCC/ MCB-Band Transport it to salvage/scrape yard after weighing (within 200mtr inside the company premises). Details as per Sl No 33 in BOQ
Installation and commissioning of PCC/MCC panes by connecting all the incoming, & outgoing cables including earthing of the panels. Details as per Sl No 34 in BOQ
Up to 6 ways. Details as per Sl No 35.1 in BOQ
Up to 12 ways. Details as per Sl No 35.2 in BOQ
Up to 24 ways. Details as per Sl No 35.3 in BOQ
Fabrication, Painting, Installation of cable tray, cable tray support, street light supports, fixing frames for MCB-DB/starters/remote push station etc. Details as per Sl No 36 in BOQ
Installation of FRP cable tray. (FRP cable tray for the works shall be provided IREL, RED). Details as per Sl No 37 in BOQ
Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm Details as per Sl No 38.1 in BOQ
Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 38.2 in BOQ
Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 38.3 in BOQ
Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 38.4 in BOQ
Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 38.5 in BOQ
Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 38.6 in BOQ
Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 38.7 in BOQ
Cable size (Al) 400Sq.mm. Details as per Sl No 38.8 in BOQ
Cable size (Cu) 1.5Sq.mm/2.5Sq.mm/4Sq.mm. Details as per Sl No 39.1 in BOQ
Cable size (Cu) 6Sq.mm/ OR (Al)16Sq.mm. Details as per Sl No 39.2 in BOQ
Cable size (Al) 25Sq.mm/35Sq.mm. Details as per Sl No 39.3 in BOQ
Cable size (Al) 50Sq.mm/70Sq.mm. Details as per Sl No 39.4 in BOQ
Cable size (Al) 95Sq.mm/120Sq.mm. Details as per Sl No 39.5 in BOQ
Cable size (Al) 150Sq.mm/185Sq.mm. Details as per Sl No 39.6 in BOQ
Cable size (Al) 240Sq.mm/300Sq.mm. Details as per Sl No 39.7 in BOQ
Cable size (Al) 400Sq.mm. Details as per Sl No 39.8 in BOQ
Laying, dressing and termination of earth strip/earth wire to the earth points on panels, equipment, earth pits etc. Details as per Sl No 40 in BOQ
Measuring, labelling and providing earth pit resistance report for all earth pits.Details as per Sl No 41 in BOQ
Transformer Oil filtration and its associated oil checks (as per IS 1180:2014, IS 1866:2000, IS 1448:1997 with its amendments) and providing report for 500KVA, 11/0.415KV transformers. Details as per Sl No 42 in BOQ
Supply, fabrication and installation of cable trays, cable tray supports, light fixing supports, DB fixing frames etc.Details as per Sl No 43 in BOQ
Painting of cable trays, cable tray supports, light fixing supports, DB fixing frames, PCC/MCC panels, PDBs, LDBs starters etc. Details as per Sl No 44 in BOQ
Additional charges for attending back shift breakdown work attending on emergency call basis per team of Supervisor and Electrician. Details as per Sl No 45 in BOQ
SMEC AUTOMATION PVT.LTD (BID ID -919913)
POZITIVE POWER INDIA PRIVATE LIMITED (BID ID -919599)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.78 MB
BOQ_289518.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .