Tender Value
₹32.4 L
EMD Value
₹64,750
Closing Date
12 Jun 2020, 1:00 pmClosed
DGM(T)M and S
Ist floor pre fabricated building, Rajghat Power House, New Delhi 110002
Repairing/Strengthening of Tower legs/stubs, chimney/muffing/coping of tower legs, raising height of chimney and earthing of 220kV and 400kV Double Circuit Transmission lines under GM(T)O and M - I
2020_DTL_189205_3
T19P122095
Open Tender
Miscellaneous Services
Works
365 days
Delhi Transco Limited
As per NIT
9 documents required · 9 mandatory
₹0
₹64,750
Yes
21 Sept 2020
28 May 2020
12 Jun 2020
28 May 2020
12 Jun 2020
28 May 2020
400kV D/C Transmission Lines under Manager(T)400kV S/Stn, Tikrikalan
Repairing/ Strengthening of rusted/damaged stubs/legs of 400kV double circuit line towers by making butt joint thereof with proper welding by suitable angles/channels/cleats etc. as per site requirement including necessary excavation., backfilling and dressing of earth around damaged stub, breaking of chimney/stub concrete manually or by drilling/chipping, laying/extending of cement concrete as per site requirement. Steel sections for cleats angles/stubs and flat plates will be made available by DTL but contractor will provide transportation with loading, unloading for transporting the material etc. among various DTL site/locations. However other required material such as cement, coarse sand, stone aggregate, welding rods, nuts & bolts with washers, petty material etc. shall be provided by contractor free of cost. Contractor will arrange his own transportation for transporting the material from DTL locations to site and vice-versa, labour and material etc. The contractor shall make his own arrangement for stay, drinking water, electricity and other civil amenities and facilities for his labour/staff and to store the material at site after receiving from J.E./Foreman.
Repairing of existing chimneys as per site requirement including all required material.
Raising the height of chimneys of 400kV double circuit line towers to avoid the submerging of tower legs in rainy season. The base of all chimneys are to be extended suitably for raising the height of chimneys of the legs to sufficient height (i.e. about 2 feet) as per site requirements. Including all the material and transportation involved for executing the repairing work.
220kV D/C Transmission Lines under Manager(T)O&M N -3
Repairing/ Strengthening of rusted/damaged stubs/legs of 220kV double circuit line towers by making butt joint thereof with proper welding by suitable angles/channels/cleats etc. as per site requirement including necessary excavation., backfilling and dressing of earth around damaged stub, breaking of chimney/stub concrete manually or by drilling/chipping, laying/extending of cement concrete as per site requirement. Steel sections for cleats angles/stubs and flat plates will be made available by DTL but contractor will provide transportation with loading, unloading for transporting the material etc. among various DTL site/locations. However other required material such as cement, coarse sand, stone aggregate, welding rods, nuts & bolts with washers, petty material etc. shall be provided by contractor free of cost. Contractor will arrange his own transportation for transporting the material from DTL locations to site and vice-versa, labour and material etc. The contractor shall make his own arrangement for stay, drinking water, electricity and other civil amenities and facilities for his labour/staff and to store the material at site after receiving from J.E./Foreman.
Repairing of existing chimneys as per site requirement including all required material.
Providing the additional earthing of 220kV of DTL in the NCT of Delhi , with the pipe type earthing & complete required materials along with transportation, loading/ unloading as per relevant IS which will be provided by contractor at his own cost.
cheena and co
Gupta Traders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .