| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹59.0 LAccepted-AOC VILL MOKHAWA TEHSIL GUDAMALANI DIST BARMER RAJASTHAN 344031 | GUDAMALANI | BARMER | RAJASTHAN | 344031 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹62.8 L+₹2.3 L (3.86%)Rejected-Finance 164 HIRANI NAGAR OPP SIDDHI VINAYAK TEMPLE MADHAPAR KUTCH 370 020 | KACHCHH | GUJARAT | 370020 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹65.5 L+₹4.9 L (8.17%)Rejected-Finance CB 1 MAHAVEER NAGAR BARMER 344001 RAJ | BARMER | RAJASTHAN | 344001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹66.0 L+₹5.4 L (9.01%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹68.9 L+₹8.4 L (13.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest Bidder |
| Sl No | Description | Qty | Unit | Hi-Tech Systems L5 | SHOBHIT BUILDERS L4 | Pelectricals L2 | NAGEL ENTERPRISES L1 | M/S PRASHANT BENIWAL L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | M & L for taking down carefully Transformer / Isolation transformer of capacity up to 750 KVA, any make, any type from pole / plinth/ base, disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm, shifting / transporting transformer carefully from the site to the workshop opening the top cover of the transformer, draining of oil from the transformer, lifting the core complete taking out defective coils from the core, cleaning the tank and reassembling the transformer after carrying out the repairs ovening the complete unit till to get desired megger value, transporting returning back to the site installing re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc all as directed by EIC. Note :(i) Spares, Rewinding of transformer,reinsulating & heating if required will be measured and paid separately under respective Sch'A' items (ii) T&P required , rent of vehicle, crane, labour involved for shifting, lifting are deemed to be included in the quoted rate.(iii) Testing to done after repair if desired result not come then contractor will redo same again without any extra cost. | 8 | Each Job | 22,500 ₹1,80,000 | 75,250 ₹6,02,000 | 11,500 ₹92,000 Lowest | 20,000 ₹1,60,000 | 31,000 ₹2,48,000 |
| 2.00 | Supply & Fixing in replacement top cover gasket made up of 5 mm thick cork sheet. | 8 | Each | 740 ₹5,920 Lowest | 1,000 ₹8,000 | 1,200 ₹9,600 | 1,800 ₹14,400 | 2,000 ₹16,000 |
| 3.00 | S & F in replacement HT bushing, porcelain vitreous brown body suitable for 11 KV Indoor/outdoor suitable upto 750 KVA capacity Transformer as per IS 3347. | 24 | Each | 1,120 ₹26,880 | 500 ₹12,000 Lowest | 500 ₹12,000 Lowest | 1,800 ₹43,200 | 2,000 ₹48,000 |
| 4.00 | S&F in replacement LT bushing, porcelain vitreous brown body 433 V grade Indoor/outdoor suitable upto 750 KVA capacity Transformer as per IS 3347. | 32 | Each | 1,000 ₹32,000 | 250 ₹8,000 Lowest | 650 ₹20,800 | 1,200 ₹38,400 | 1,000 ₹32,000 |
| 5.00 | S&F in replacement HT brass studs,Nuts, Chucknuts along with washers complete with rubber parts for one terminal 11 KV Indoor/outdoor suitable upto 750 KVA capacity Transformer. | 24 | Each | 1,590 ₹38,160 | 700 ₹16,800 | 500 ₹12,000 Lowest | 1,500 ₹36,000 | 1,000 ₹24,000 |
| 6.00 | S&F in replacement LT brass studs,.nuts,chuknuts along with washers for one terminal 433 Volts grade Indoor/outdoor suitable upto 750 KVA capacity transformers. | 32 | Each | 1,540 ₹49,280 | 800 ₹25,600 | 500 ₹16,000 Lowest | 1,200 ₹38,400 | 1,300 ₹41,600 |
| 7.00 | S&F in replacement breather assembly complete with silica GEL as required at site. | 8 | Each | 1,795 ₹14,360 | 2,000 ₹16,000 | 1,250 ₹10,000 | 1,000 ₹8,000 Lowest | 1,000 ₹8,000 Lowest |
| 8.00 | Supply and fix in replacement Temp level indicator including its bolts, nuts, gasket etc complete. | 8 | Each | 1,600 ₹12,800 | 1,000 ₹8,000 Lowest | 2,500 ₹20,000 | 2,500 ₹20,000 | 4,000 ₹32,000 |
| 9.00 | Rewinding old / burnt out HT coils by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, tanking, ovening, keeping coils in position, etc for transformer up to 63 KVA to 160 KVA. | 265 | Kilogram | 2,050 ₹5,43,250 | 1,200 ₹3,18,000 | 1,100 ₹2,91,500 Lowest | 1,200 ₹3,18,000 | 1,100 ₹2,91,500 Lowest |
| 10.00 | Rewinding old / burnt out HT coils by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, tanking, ovening, keeping coils in position, etc for transformer up to 200 KVA to 750 KVA. | 304 | Kilogram | 2,050 ₹6,23,200 | 1,200 ₹3,64,800 | 1,100 ₹3,34,400 Lowest | 1,200 ₹3,64,800 | 1,150 ₹3,49,600 |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
1 Jul 2026, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
REPAIR/REPLACEMENT AND PREVENTIVE MAINTENANCE TO THE HT SWITCH GEARS LIKE TRANSFORMER, VCB, RMU, VLE SWITCHES, RELAYS, ISOLATION TRANSFORMER AND HT UG CABLES AND OTHER CONNECTED ITEMS AT AF STN BHUJ
2026_MES_769010_1
84276/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) BHUJ
₹1.4 L
Yes
13 Aug 2026
1 Jun 2026
4 Jul 2026
1 Jun 2026
1 Jul 2026
23 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for taking down carefully Transformer / Isolation transformer of capacity up to 750 KVA, any make, any type from pole / plinth/ base, disconnecting HT & LT side connections, earthing strip of transformer, supporting angles, cross arm, shifting / transporting transformer carefully from the site to the workshop opening the top cover of the transformer, draining of oil from the transformer, lifting the core complete taking out defective coils from the core, cleaning the tank and reassembling the transformer after carrying out the repairs ovening the complete unit till to get desired megger value, transporting returning back to the site installing re-commissioning and testing of the transformer at its original place, connecting up HT & LT sides, earthings, supports / cross arms etc all as directed by EIC. Note :(i) Spares, Rewinding of transformer,reinsulating & heating if required will be measured and paid separately under respective Sch'A' items (ii) T&P required , rent of vehicle, crane, labour involved for shifting, lifting are deemed to be included in the quoted rate.(iii) Testing to done after repair if desired result not come then contractor will redo same again without any extra cost. | 8 | Each Job | 1 | ₹8 |
| 2 | Supply & Fixing in replacement top cover gasket made up of 5 mm thick cork sheet. | 8 | Each | 1 | ₹8 |
| 3 | S & F in replacement HT bushing, porcelain vitreous brown body suitable for 11 KV Indoor/outdoor suitable upto 750 KVA capacity Transformer as per IS 3347. | 24 | Each | 1 | ₹24 |
| 4 | S&F in replacement LT bushing, porcelain vitreous brown body 433 V grade Indoor/outdoor suitable upto 750 KVA capacity Transformer as per IS 3347. | 32 | Each | 1 | ₹32 |
| 5 | S&F in replacement HT brass studs,Nuts, Chucknuts along with washers complete with rubber parts for one terminal 11 KV Indoor/outdoor suitable upto 750 KVA capacity Transformer. | 24 | Each | 1 | ₹24 |
| 6 | S&F in replacement LT brass studs,.nuts,chuknuts along with washers for one terminal 433 Volts grade Indoor/outdoor suitable upto 750 KVA capacity transformers. | 32 | Each | 1 | ₹32 |
| 7 | S&F in replacement breather assembly complete with silica GEL as required at site. | 8 | Each | 1 | ₹8 |
| 8 | Supply and fix in replacement Temp level indicator including its bolts, nuts, gasket etc complete. | 8 | Each | 1 | ₹8 |
| 9 | Rewinding old / burnt out HT coils by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, tanking, ovening, keeping coils in position, etc for transformer up to 63 KVA to 160 KVA. | 265 | Kilogram | 1 | ₹265 |
| 10 | Rewinding old / burnt out HT coils by super enameled copper winding wire / strips of appropriate size of super quality (as per existing material & size of transformer coils) including, insulating, tanking, ovening, keeping coils in position, etc for transformer up to 200 KVA to 750 KVA. | 304 | Kilogram | 1 | ₹304 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
TENDER84276.pdf
Tender Documents • 0.94 MB
4.EM SEPERATE.pdf
Tender Documents • 9.55 MB
BOQ_861200.xls
BOQ • 1.54 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .