| 1 | L1₹32.2 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹33.3 L+₹66,963.50 (2.05%)Rejected-Finance B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Rejected-Finance HIGHER RATE | |
| 3 | Rejected-Technical A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY a(i) | |
| 4 | Rejected-Technical | - | Rejected-Technical NOT ENLISTED IN APPROPRIATE CATEGORY a(i) |
Tender Value
₹29.9 L
EMD Value
₹59,880
Closing Date
17 Apr 2025, 6:00 pmClosed
GE ARMY
BHUJ
SPECIAL REPAIR TO THE OLD POWER SUPPLY PANELS LUGS AND SPECIAL REPAIR TO THE STAGING OF OVERHEAD WATER TANK FOR 05 IN NO BATHROOM COMPLEXES AT 4M DET SIYOT AND PROVISION OF GENERATOR SET DIESEL ENGINE AC OF CAPACITY 15 KVA 12KW AT MIL STN BHUJ
2025_MES_702289_1
8296
Open Tender
Civil Works
Item Rate
180 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹59,880
Yes
21 May 2025
22 Mar 2025
19 Apr 2025
22 Mar 2025
17 Apr 2025
4 Apr 2025
Amount
From Item No 01 to 33 Location of work is Siyot Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in hard soil complete as specified and as directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete as specified and as directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete as specified and as directed.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. (Note: Punned thickness shall only be measured and paid)
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete as specified and as directed.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe complete as specified and as directed.
Disconnecting, taking out, removing old existing unserviceable LT underground cable of any size complete as specified and as directed.
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete including transportation from store to site all as specified and directed of size 4 core 16 sqmm complete as specified and as directed.
All as per above Item No.8 here in above but of size 3.5 core 35 Sqmm complete as specified and as directed.
All as per above Item No.8 here in above but of size 3.5 core 50 Sqmm complete as specified and as directed.
All as per Item No.8 here in above but of size 3.5 core 70 Sqmm complete as specified and as directed.
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in hard rock vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron strip 25 X 4 mm , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ (NOTE - The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced with 8mm dia TMT bars @ 150mm C/C both ways, funnel with watering pipe.)
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25X4mm dia galvanised steel strip complete as specified and as directed.
All as per item no 14 here in before but LT Panel consisting of following items Location : PH ,Parde ,Hill top (a) copper Bus Bar 240 A rating for 3 Phase and 120 A for Neutral - 01 Set (b) 3 Line digital multimeter for measuring basic electrical parameter of all outgoing and incomings (c) LED Indication Lamp for 3 Phase for incoming and for all outgoing (e) MCCB 4 Pole 160Amps 36 KA , Ics=100%ICu, thermal adjsutable, shortcircuit adjsutable - 01 Nos (01 No for Incoming) (f) MCCB 4 Pole 100 Amps 16 KA Ics=100%ICu, thermal adjsutable, shortcircuit adjsutable- 01 Nos (01 Working) (g) MCCB 4 Pole 63 Amps 16 KA - 04 Nos (03 Working +1 stand by)
All as per item no 14 here in before but LT Panel consisting of following items Location : court, gallery, Rear gate. (a) Copper Bus Bar 240 A rating for 3 Phase and 120 A for Neutral - 01 Set (b) 3 Line digital multimeter for measuring basic electrical parameter of all outgoing and incomings (c) LED Indication Lamp for 3 Phase for incoming and for all outgoing (e) MCCB 4 Pole 160 Amps 36 KA, Ics=100%ICu, thermal adjsutable, shortcircuit adjsutable - 01 Nos (01 No for Incoming) (f) MCCB 4 Pole 63 Amps 16 KA - 05Nos (04 Working +1 stand by No for outgoing) (g) MCB SPN 32A outgoing -2 nos (01 working +01 standby for outgoing)
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete as specified and as directed.
M & L for PCC 1:4:8 type D2 (using 40mm graded trap stone aggregate) as in foundation complete as specified and as directed.
S&F of Framed works for chain links angles, frame work for watertanks including etc conforming to Fe-290.Gde-E-165 complete as specified and as directed.
Supply only mild steel flat iron of Fe-410-0 or Fe-310-0 in required length for fixing/supporting to chain link fencing and post and water stageing complete as specified and as directed.
M&L Preparation of new steel surface exc 10 cm width and girth and applying two coat of synthetic enamel paints over and including a coat of red oxide primer complete as specified and as directed.
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F Stop valves, cast copper alloy, ISI marked ,screwed down high pressure with crutch of butter fly handle, fancy type , chromium plated, with long shank and cup, screwed both ends for iron pipes or for union , for 15 mm bore , complete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 15mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 25mm dia, any grade, of any description or in any position including fittings complete all as specified and directed.
Supplying and Laying 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and Laying 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
Supplying and Laying 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed.
S&F bib tap, cast copper alloy chromium plated, screwed down high pressure with crutch of butter fly handle fancy type CP for 15 mm bore dia complete all as specified and directed.
S&F for Swivel shower rose size 125 mm of PTMT , any colour , for fixing with 15 mm dia pipe ,( minimum weight 40 gm. ) with and including Shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of PTMT any colour (Min wt. 40gms) , fixed in repairs , complete all as specified and directed .
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm complete as specified and as directed.
S&F in repair Bib tap standard of PTMT any colour high pressure screwed for iron pipe 15mm bore (Minimum weight 90 gms) complete all as specified and directed.
(a) Engine: Diesel engine,direct injection, water cooled as per manufactured standard BHP @ 1500 RPM for continuous duty of suitable for 15 KVA alternator with provision of 10% over load for one hour in every 12 hour running confirming to latest BS/IS totally enclosed .The engine shall consists of following specification :- The scope of supply includes: -Electrical starter motor 12V DC, Battery charging alternator -Radiator cooling,with turbo charged after cooling -Fuel injection Pump -Governor -fuel filter -Spin-on full flow lub oil filter -Residential silencer -Dry type air cleaner -Shut-off coil with safeties for LLOP/HWT -Flywheel and flywheel housing to suit single bearing alternator
(i) Alternator: suitable for operation at 1500 RPM, 415 Volts, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire system, conforming to latest BS/IS. The Alternator is brushless type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator has the following features: -+ 1.0 % Voltage regulation (max.) in static conditions -Permissible overload of 10%. operation as per standards (ii) Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. The steel shall be TESO / SAIL or equivalent make
(iii) Control panel: The control panel is manufactured with standard gauge CRCA sheet and is powder coated for a weather-proof, long lasting finish. The control panel consists of following parts: -Standard engine instrumentation -Multi function meter which measures: 1) Individual phase current (Amps) 2) Phase voltages (V) 3) Generator output frequency (Hz) 4) Engine water temperature (Deg.C) 5) Lube oil pressure (kg/cm2) and equipped with hour counter -MCCB of suitable rating -Key switch -Push button (Starter) -LED: Battery charging alternator fail indication -Current transformers -Instrument fuses duly wired and ferruled (iv) Others: -Fuel tank suitable for 8 hours of operation -One charged battery 12V, suitable rating AH with battery leads & cable
Acoustic enclosure: The acoustic enclosure is made of standard CRCA sheets and structural/ sheet metal base frame duly painted. The walls of the enclosure are insulated with fire retardant foam so as to comply with the 75 dBA at 1mtr sound levels specified by Ministry of Environment & Forest. The enclosure has the following features: -Specially designed to meet stringent MOEF/ CPCB norms of 75 dBA @ 1mtr at 75% load under free field conditions, -Single point lifting for easy handling, -Designed to have optimum serviceability -Air inlet louvers specially designed to operate at rated load, -Made on special purpose CNC machines for consistency in quality and workmanship, -Powder coated for long lasting service life and superior finish, -With UV resistant powder coating, can withstand extreme environments, -Use of special hardware for longer life, -Insulation material meets exacting IS 8183 specifications for better sound attenuation, -Flush styling - no projections, -Fluid drains for lube oil and fuel, -Fuel filling point. The following tools are requried for maintenence of DG Set and to be handed over to Engr-in-Charge. Tools (As per manufacturers instructions (a) 'D' spanners - 01 Set (b) Ring spanners - 01 Set (c) Screw driver 5" to 12" - 01 Set (d) Cutting plier 9" - 01 No (e) Hammer 2 LBS - 01 No Note : Rate of Cable suitable size for connecting AMF panle to DG set deemed to be included in quoted rate
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for sand cushioning in trenches for protection of LT under ground cable including watering and consolidation.
Supplying and laying un-reinforced precast concrete cable cover class LV Type 1, flat, size 250mm x 150mm x 40mm complete.
Supply and laying GI tube light grade 40 mm bore complete.
Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type , front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :-
Incoming
(a) Copper Bus bar, 200 Amps TPN -01 set
(b) MCCB 4 Pole thermal magnetic release 415 volts 100 A 25 KA-01
(d) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(f) Digital Multifunctional meter - 01 No
Outgoing
(g) MCCB 4 Pole thermal magnetic release 415 volts 63 A 25 KA-01
(h) MCCB 4 Pole thermal magnetic release 415 volts 40 A 16 KA-02
(j) On load type 4 pole chage over switch of capacity 100Amps.
(k) Spare compartment for 63 Amps MCCB 4 Pole Thermal adjustable and magnetic adjuistable release - 01 Nos
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected to galvanized iron earth strip 32 x 6 mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’
Abhishek Enterprises (BID ID -3281419)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .