Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-Finance | L1 | Accepted-Finance AS PER DOCUMENTS | |
| 2 | L2₹7.3 L+₹7,495 (1.04%)Accepted-Finance | L2 | Accepted-Finance AS PER DOCUMENTS | |
| 3 | L3₹7.5 L+₹36,842.50 (5.13%)Accepted-Finance | L3 | Accepted-Finance AS PER DOCUMENTS | |
| 4 | L4₹8.2 L+₹99,790 (13.9%)Accepted-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L4 | Accepted-Finance AS PER DOCUMENTS |
Tender Value
₹7.4 L
Closing Date
11 Feb 2025, 6:50 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMDT CHARANMEET SINGH
CGDHQ-1, PORBANDAR
DEFECT RECTIFICATION ON VARIOUS HULL ENGINEERING AND ELECTRICAL DEFECTS ONBOARD ICGS C-445 AND C-161
2025_ICG_696758_1
344/161/445/10/24-25
Limited
Miscellaneous Services
Lump-sum
AT ICGS C-161, C-445
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
13 Feb 2025
6 Feb 2025
12 Feb 2025
6 Feb 2025
11 Feb 2025
6 Feb 2025
Amount
C-445-E-22:Following defects observed on emergency fire pump: (i) Pump Discharge hose female end connection deteriorated. End connection to be fabricated. (ii) Pump suction end connection deteriorated. Connection to be fabricated. (iii) Pump body cover deteriorated. To be repaired. (iv) Battery starter motor not working. System to be overhauled and proved. Defect to be rectified by repair/renewal of defective items. Pump to be proved satisfactory operation.
C-445-E-24Following defects observed in diving air compressor:- (i) Vibration observed in belt guard cover due to deterioration of welding joints. Guard to be fabricated. (ii) Belt found loosen due to improper alignment. Alignment to be rectified by repair/renewal of pulley. (iii) 1st and 2nd stage cylinder holding clamps uprooted. To be repaired. (iv) Compressor to be overhauled and air analysis to be carried out and certificate to be submitted.
C-445-H-179: Following defects observed onboard Gemini:- (i) Air charging NV valves not holding pressure. Same to be renewed/ repaired.(Qty- 05 nos). (ii) Life line deteriorated. Same to be renewed/ repaired as per sample. (iii) Sitting planks in Gemini ruptured. Same to be repaired as per sample. (Qty- 03 Nos) (iv) Straps deteriorated at various locations same to be renewed and fixed in position as per sample. (Qty-09 Nos).
C-161: E006-Following defects were observed from Stbd DA (Make: Caterpillar, Model: C4.4 DITA)are as follow:- (i) Minor sea water leakage observed from pin hole on discharge pipeline (Dia: 40 mm, length: 50cm, Mat: Cu)of sea water pump. (ii) Sea water suction was not developing after discharge of sea water pump suspect bearing inside the pump may be deteriorated or shaft along pinion gear may be defective. Same to be renewed/rectified and proved for satisfactory operation.
C-161-L008: ASD compartment exhaust fan not working and showing low insulation, suspect motor winding burnout. Defect to be rectified/ renewed and proved for satisfactory operations.
C-161-L010: Captain washroom and sailor's washroom exhaust fan not working, showing low insulation, suspect motor winding burnout and power supply also not available at motor terminal, suspect cable faulty between breaker and motor terminal. Defect to be rectified and proved for satisfactory operations.
C-161-L004: Annual servicing of 02 in Nos. SART(Make: Samyung, Model: SAR-9) falling due in Jan 25. Service to be carried out and proved for satisfactory operation.
C-161: L005: Annual servicing of 01 in No. EPIRB(Make: McMurdo, Model:Z704) falling due in Jan 25. Service to be carried out and proved for satisfactory operation.
C-161-H-025: 02 in Nos. commissioning plates, 01 in No. ship builder plate and 02 in Nos. ship's name plates deteriorated. Same to be electroplated. (Mat: Brass)
C-161-L003: 01 in no. Charger of Radio equipment non-ops suspect SMPS unit defective, same to be rectified and proved for satisfactory operation.
C-161-L012: 06 Nos. Navigation Light non-ops, output voltage not available from control unit, suspect PCB is defective, same to be rectified and proved for satisfactory operation. Above mention defects are needs to be rectified for maintain good navigation &communication and seaworthy.
MSS Meditechno Pvt. Ltd. (BID ID -3233951)
Chamunda Fabrication (BID ID -3233904)
OM ENTERPRISE (BID ID -3233636)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_780201.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .