Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹3.0 L+₹15,630 (5.48%)Rejected-Finance | L2 | Rejected-Finance Other Than Lowest tenderer | |
| 3 | L3₹3.3 L+₹41,235 (14.5%)Rejected-Finance | L3 | Rejected-Finance Other Than Lowest tenderer | |
| 4 | L4₹3.3 L+₹43,090 (15.1%)Rejected-Finance | L4 | Rejected-Finance Other Than Lowest tenderer | |
| 5 | L5₹3.4 L+₹57,336 (20.1%)Rejected-Finance | L5 | Rejected-Finance Other Than Lowest tenderer |
Tender Value
₹3.2 L
EMD Value
₹6,400
Closing Date
22 Dec 2022, 6:00 pmClosed
AGE (I) Suryalanka
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENTS
2022_MES_567009_1
AGE(I)/SL/8497
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Suryalanka
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹300
AGE (I) SURYALANKA
₹6,400
Yes
26 Dec 2022
2 Dec 2022
24 Dec 2022
2 Dec 2022
22 Dec 2022
16 Dec 2022
3 Dec 2022 - 9 Dec 2022
Amount
M&L for point wiring complete with 1.5 Sqmm single core multistranded copper conductor, FURLS, PVC insulated unsheathed cable 1100 volts grade fixed in and including concealed/surface PVC conduit, making good with chasing, chipping, applying cement, fitting and accessories, joints boxes including one 1.5 sqmm copper FRLS PVC insulated unsheathed as earth continuity conductor connected in the common earth along with MS/GI box, hilum sheet of 3mm thick for mounting switches/sockets complete all as specified and as directed including taking down existing point wiring for Light/ Fan/ Exhaust fan/ Independent 5 A Socket/ Security light complete all as specified and as directed.
All as per item No. 1 above but with 4 sqmm Single core wiring for Phase, neutral and earth for Independent 15 Amps power socket complete all as specified and as directed.
S&F in repairs Modular socket, 6A, 5 pin combination 2 module complete all as specified and as directed.
S&F in repairs modular switch socket combination 16A, 6 pin, 3 module complete all as specified and as directed.
S&F in repairs modular switch one way 6 Amps, 1 module complete all as specified and as directed.
S&F in repairs of Modular Bell Push 6/10 Amps, 01 Module complete all as specified and as directed.
S&F in repairs of modular Fan regulator electronic step type, 120W- 2 module, 240V single phase complete all as specified and as directed.
S&F in repairs flush type switch socket combination 5A, 2 in one , complete all as specified and as directed.
S&F in repairs flush type switch socket combination 16A, 3 pin, complete all as specified and as directed.
S&F in repairs socket 2 in 1, 3 pin, 6 Amp flush type universal complete all as specified and as directed.
S&F in repairs switch flush type one way 6 Amps, complete all as specified and as directed.
S&F in repairs of stepped type electronic Fan regulator flush type , 120W 240V single phase complete all as specified and as directed.
S&F in repairs of flush type Bell Push 5/6 Amps, complete all as specified and as directed.
S&F in repairs of 230 Volts, AC, Bell Ding-Dong complete all as specified and as directed.
S&F in repairs modular white cover plate with frame and metal flush box, 3 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame and metal flux box, 6 module complete all as specified and as directed.
S&F in repairs modular white cover plate with frame and metal flush box, 12 module complete all as specified and as directed.
S&F in repairs ceiling rose, 3 plate PVC/polycarbonate, isolated body complete all as specified and as directed.
S&F in repairs submain wiring with two run of single core cable FRLS PVC insulated sheathed cable 1100 volts grade 4 Sqmm copper multistranded conductor including and drawing into concealed/Surface PVC conduit, making good with chasing, chipping, applying cement, fixed on/in wall, ceiling including 4 sqmm FRLS PVC insulated unsheathed multistranded for earth wire connected to earth complete including taking down existing sub main wiring complete all as specified and as directed.
All as per Item No.19 but with 6 sqmm copper FRLS cable complete all as specified and as directed.
S&F in repairs LED Bldg light fitting with and including individual high power 25 watt, efficiency not less than 110LM/W LED new generation energy saving and environmental friendly long life LED street light made up of pressure die cast alu with secondary optics, suitable for outdoor use IP 66, fixed on Wall/ Pole, connected with connecting cable, making good disturbed surface complete all as specified and as directed.
S&F in replacement of MCB, SP 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.
S&F in replacement of MCB, SPN 6-32 Amps, C Curve, 10 kA, Complete all as specified and as directed.
S&F in replacement of MCB, Four Pole 40 - 63 Amps, C Curve Complete all as specified and as directed.
S&F in replacement of MCB, Three Pole 40 to 63 Amps, C Curve Complete all as specified and as directed.
S&F in repair MCB DB Double Door, SPN 8 way IP 54, fixed to wall in concealed by disturbing the existing wall surface and making good complete all as specified and as directed.
S&F in replacement two pin and earth Metal clad plug and socket with MCB SP 20Amps, complete all as specified and as directed.
S&F 4 Feet LED Tube light of 20 Watt Batten with integrated electronic driver having THD < 20% and aluminium housing with necessary fixing screws, and connected upto ceiling rose including taking down existing Tube light fitting of any type and making Good complete all as specified and as directed.
S&F 2 Feet LED Tube light of 10 Watt Batten with integrated electronic driver and aluminium housing with necessary fixing screws, and connected upto ceiling rose including taking down existing Tube light fitting of any type and making Good complete all as specified and as directed.
S&F in repair LED Tube light of 10/15 Watt recess type round cut, suitable for 6 inch size cut hole of false ceiling with electronic driver, necessary fixing screws/ clips, and connecting including taking down existing light fitting of any type and making Good complete all as specified and as directed.
Taking down ceiling fan/ Exhaust fan/ wall mounted fan/ pedestal fan of any make and sweep, cleaning externally and internally. Stripping out the fans, examine the unserviceable spares/ burnt winding by testing, cleaning and lubricating bush/ bearings. Refixing the fan to any location and position after necessary works/ servicing including carring out the replacement worn out parts, body covers, screws, spilt pins nuts condensor and flexible wire copper conductor from ceiling fan to ceiling rose etc complete all as specified and directed. Note:- (i) The parts replaced will be measured by relevant item as supplied only.
Removing defective winding of any type / sweep of ceiling fan and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of any make and re-assembling testing complete including replacement of flexible copper wire from ceiling rose to ceiling fan complete all as specified and as directed.
All as per Item No. 32 above but exhaust fan of size 300/ 380mm sweep complete all as specified and as directed..
All as per Item No. 32 above but exhaust fan of size 400/ 450mm sweep complete all as specified and as directed.. Note for Serial Item No. 32 to 34 (a) Replacement of spare parts found unserviceable/ defective will be measured and paid separately under relevant item of BOQ as supply only. (b) The rate for fixing serviceable items and new replaced items are deemed to be included in unit rate quoted by tenderer for above item. (c) All retrieved unserviceable item obtained from dismantling shall be given to the contractor under relevant item of 'Schedule of Credit'.
Supply only following spare parts of ceiling fan of 1200mm/ 1400mm sweep of different make required as per the makes of existing fans as required at site or in winding shop complete all as specified and as directed.
Rubber bush for shackle with bolt, nut, washers and lock pin suitable for Ceiling fan 1200mm/ 1400mm sweep complete all as specified and as directed.
Ball bearing of size No. 6201/6202/ 6203 suitable for ceiling fan / exhaust fan complete all as specified and as directed. Make:- SKF/ NBC/NTN/ ZKL/ Koyo/ Tata/ RHP
S&F in replacement condenser (capacitor) 3.15/ 2.5 MFD, 220 Volts, AC, 50 Hz as per IS : 1709 suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and as directed. Make:- Tibcon/Ducati/ Keltron/ Crompton / Bajaj / Concap/ ABB
S&F in replacement condenser 4 MFD, 220 Volts, AC, 50 Hz as per IS : 1709 suitable for exhaust fan 300/ 380/ 450 mm sweep complete all as specified and as directed. Make:- Tibcon/Ducati/ Keltron/ Crompton / Bajaj / Concap/ ABB
M&L for repair/ replacement of heater element of 1.5 kw suitable for geyser of capacity 15 to 25 Ltr as per exisiting model complete all as specified and as directed.
M&L for repair/ replacement of Thermostat suitable for geyser of capacity 15 to 25 Ltr as per exisiting model complete all as specified and as directed.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .