Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | ₹16.7 L Quoted ₹16.8 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹16.9 L+₹7,926 (0.47%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | ₹16.9 L+₹7,926 (0.47%) | L2 | Rejected-Finance Being L2 |
| 3 | L3₹18.3 L+₹1.5 L (8.64%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹18.3 L+₹1.5 L (8.64%) | L3 | Rejected-Finance Being L3 |
| 4 | L4₹20.9 L+₹4.0 L (23.9%)Rejected-Finance | ₹20.9 L+₹4.0 L (23.9%) | L4 | Rejected-Finance Being L4 |
| 5 | L5₹20.9 L+₹4.1 L (24.2%)Rejected-Finance | ₹20.9 L+₹4.1 L (24.2%) | L5 | Rejected-Finance Being L5 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
9 Mar 2020, 6:00 pmClosed
GE AF BARODA
GE BARODA PO MAKARPURA BARODA 390014
REPAIR TO PLINTH PROTECTION, PLASTER, FLOORING, COMPOUND WALL, FENCING AND OTHER CONNECTED ITEMS AT MAKARPURA AF STN BARODA
2020_MES_319908_1
8557/E8
Open Tender
Miscellaneous Services
Item Rate
335 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND BOQ
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹48,000
Yes
12 May 2020
30 Jan 2020
12 Mar 2020
30 Jan 2020
9 Mar 2020
17 Feb 2020
31 Jan 2020 - 4 Feb 2020
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and directed.
Demolition of Concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Taking down cement plastered on brick or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for 15MM thick rendering in two layers (i.e) CM 1:6, 10mm thick as first layers and CM 1:4, 5mm thick as 2nd layer wtih water proofing compund on stone masonry surfaces or surfaces other than fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for 5 mm thick rendering on ceiling surfaces of concrete in cement mortar 1:3 finished even and smooth (without using extra cement) complete all as specified and directed.
M&L preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint over alkali resistant priming coat on walls upto 4th floor including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed.
-Ditto- all as per item No 06 above but on ceiling surfaces -ditto-.
M&L for complete removal of existing treatment by scraping down completely on brick walls/stone walls/concrete surfaces plastered or unplastered thoroughly, rubbing down, washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of Cement Base Paint (Colour or shade as approved by GE) over alkali resistant priming coat as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy including necessary steel scafolding upto 4th storey complete all as specified and directed.
-Ditto- all as per item No 08 above but on ceiling surfaces -ditto-.
M&L preparation of newly plastered or unplastered wall surfaces and applying two coats of exterior ACRYLIC Emulshion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy including necessary steel scafolding upto 4th storey complete all as specified and directed.
-Ditto- all as per item No 10 above but on ceiling surfaces -ditto-.
M&L for complete removal of existing treatment wall/ceiling surfaces by scraping down completely on brick/stone walls/concrete surfaces thoroughly, rubbing down washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of exterior ACRYLIC Emulshion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy including necessary steel scafolding upto 4th storey complete all as specified and directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 75mm thick Cement concrete type C-2 1:3:6 (using 40mm graded crushed stone aggregates) as in plinth protection , finished surfaces even and smooth without using extra cement, complete all as specified and as directed.
M&L for 75mm thick Plain cement concrete type D-2 1:4:8 (using 40mm graded crushed stone aggregate) as in thick sub base of flooring finished surfaces rough to receive floor finishes, complete all as specified and as directed.
M&L for 100mm thick Plain cement concrete type B-1 1:2:4 (using 20mm graded crushed stone aggregate) as in flooring, finished surfaces rough , complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and colour pigment , complete all as specified and as directed including taking down old unservicable existing pever block.
Taking down existing pever block and re-fixing of Machine pressed precast concrete interlocking paver block any shape, size and thickness, with grey cement and colour pigment , Complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation in layers, complete all as specified and as directed.
M&L for continuous Precast Plain Cement Concrete Kerb stone of size 400x200x100mm with Type B1 (1:2:4) (using 20mm stone aggregate) including weathering, slightly rounded or chemfered angle and set in cement mortar 1:4, complete all as specified and as directed.
Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A', complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings complete all as specified and as directed.
M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed.
M&L Rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:6, finished even and smooth without using extra cement complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and as directed.
M& L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165, complete all as specified and as directed.
Chanda Construction Co.
M/S Badri Electicals
Indobuildenterprise
RAIKA ENTERPRISES
Parimal Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .