Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.6 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L-1 | Accepted-AOC Accepted | |
| 2 | L-2₹20.2 L+₹4.3 L (27.2%)Rejected-AOC HOUSE NO 120 1 NEAR HANUMAN MANDIR AT POST SHEL PIMPALGAON TAL KHED DIST PUNE PIN 411014 | PUNE | MAHARASHTRA | 411014 | L-2 | Rejected-AOC Rejected | |
| 3 | L-3₹20.3 L+₹4.5 L (28.2%)Rejected-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | L-3 | Rejected-AOC Rejected | |
| 4 | L-4₹20.6 L+₹4.7 L (29.7%)Rejected-AOC | L-4 | Rejected-AOC Rejected | |
| 5 | L-5₹2.0 Cr+₹1.9 Cr (1168.9%)Rejected-AOC T 1 GARDEN VIEW APARTMENT NEW BANKER COLONY MUNDRA ROAD BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | L-5 | Rejected-AOC Rejected |
Tender Value
₹16.5 L
EMD Value
₹33,000
Closing Date
1 Sept 2022, 6:00 pmClosed
GE AF NALIYA No 1
GE AF Naliya
REPAIR, MAINT REPLACEMENT OF SECURITY LIGHTS, STREET LIGHTS, FLOOD LIGHTS, TIMER PANELS, CABLES AND CONNECTED ITEMS AT TECH AREA AT AF STN NALIYA
2022_MES_546029_1
8840/E8
Open Tender
Miscellaneous Works
Item Rate
330 days
Naliya
Class E category b(I)
8 documents required · 8 mandatory
₹500
Yes
GE AF NALIYA No 1
₹33,000
Yes
31 Oct 2022
18 Aug 2022
3 Sept 2022
18 Aug 2022
1 Sept 2022
25 Aug 2022
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for laying of under ground electric cable complete all as specified.
Taking out LT UG cables of any size by excavation and earth work in any type of soil, removing bricks or PCC cover of any size complete all as specified and directed NOTE:- (i) Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately.
Relaying old serviceable under ground LT cable of any size obtained from item 2 above complete all as specified and directed.
Supply and lay, jointing and testing in repairs/replacement of LT cable of size 16 Sqmm 4 core XLPE insulated, armoured, heavy duty with multi stranded aluminum conductors, 1100V grade, laid in trenches / ducts / through GI pipe fixed to pole complete all as specified and directed Note: Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately.
M & L for river bed sand used in trenches/ ducts 08 cm under cable and 15 cm above the cable for cushioning/protection to cable and get thick 18cm after hand punning complete all as specified and directed. Note: Punned thickness shall be measured for payment purpose.
Laying only serviceable un-reinforced precast concrete cable cover class LV, Type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over for cable protection complete all as specified and directed.
Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over for cable protection.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed
Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified
Supply, fixing and testing LT cable jointing kit straight through type heat shrinkable suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100 volts grade LT cable of size 3.5/4 core 16 to 50 sqmm and including taking out cable from faulty portion in any situation/position complete all as directed.
All as per srl item No 10.00 here-in-before but size 3.5 core 70 sqmm to 150 sqmm .
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads in drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, pipes of 50 mm bore ,fixed in repair complete all as specified and as directed.
Restretching/ tightening of ACSR conductor of any type and size by disconnecting from insulators from any location complete all as directed. Note:- (i) Proper shut down has to be taken from MES. (ii) T & P i.e. Ladder, safety items, or any other equipment for repair tightening of ACSR conductor shall be provided by Contractor and cost for the same deemed to be included in respective items
Dismantling / taking down in repairs the street light / security lights of any capacity & description from existing LT pole/walls at any height and refixing the fittings in existing / another location after repair work all as directed by Engg-in-charge. Note:- (i) Replacement of defective parts / accessories shall be measured and paid separately under relevant items. (ii) Transport and T & P i.e. Ladder, safety items, or any other equipment for repair of street light shall be provided by Contractor and cost for the same deemed to be incl in respective items
S&F in repair tube rod for T-5 light fitting 24 watts complete all as specified
S&F Electronic ballast 24 watts for T 5 light fitting lamps complete all as specified
S&F bipin Lamp Holder suitable for 24W FTL street light fitting complete all as specified
S&F in repairs brackets for street light fitting made out of 32 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. clamps made of M.S flat of size 40 mm x 3 mm, 2 Nos, M.S nut & bolt with cup washers and dismantling old rusted/unserviceable bracket with its rusted clamps and nut bolts complete all as specified. Note- Rate of GI Pipe, clamps, flat and nut bolts inclusive in item rate
S&F in repair service wire 1100 volts grade PVC insulated PVC unsheathed cable multi stranded copper conductor of size 3 core 1.0 sqmm complete all as specified
S&F in repair service wire 1100 volts grade PVC insulated PVC sheathed cable weather proof multi stranded with aluminum conductor of size 2 core 6.0 sqmm complete all as specified
M&L for Cutting under road/PCC path and passing GI pipe for cable protection and making good as existing complete all as specified and as directed.
Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fixing LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
S&F in repair/replacement of auto /manual street light timer nature switch weather proof enclosure made out of UV stabilized, FR grade special molding compound, rust proof, electric shock proof, vermin proof outdoor pole mountable with mounting bracket made out of GI and nut, bolts, washers including cable glands, openable door with 08 kW three phase load with Power contactors 3nos as incoming and outgoing with MEC rating of 32 Amps/phase and circuit wiring of min 16 sqmm including taking down existing switch complete al as specified.
S&F in repair/replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded and cover with hinged door, pole mounting type comprising of aluminum TPN bus bar of 60 Amps of minimum size 300x250x150mm, fixed on pole with MS, clamps 30x5mm with necessary nuts, washer complete all as directed. Note. Rate of TPN bus bar and MS clamp inclusive in item rate
S&F in repair LED Aviation light at overhead tank/Signal tower/Telephone tower or any high rise buildings at any location of Red colour, 230V AC complete all as specified and directed.
S&F in repair LED driver 45/48W 1500mA suitable for LED light fitting
S&F in repair LED driver 72W/80W 2600mA suitable for LED light fitting
S&F in repair LED driver 100W,2600mA suitable for LED light fitting
S&F in repair LED driver 150/240W3000mA suitable for 240 watt LED light fitting
S&F in repair MH ballast 70W suitable for 70 watt MH light fitting
S&F in repair MH ballast 150W suitable for 150/250 watt MH light fitting
S&F in repair MH ballast 250W suitable for 250 watt MH light fitting
S&F in repair MH lamp 70W suitable for 70 watt MH light fitting
S&F in repair MH lamp 150W suitable for 150/250W MH light fitting
S&F in repair MH lamp 250W suitable for 400W MH light fitting
S&F in repair Igniter for MH lamp suitable for 70/150/250/400W MH light fitting
Trimming of tree branches touching to over head lines, up to 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearance of HT/LT pole and sub station premises all as directed Note: (i) Trimming of all branches of trees falling under one span between two pole shall be considered as one span only. (ii) Contractor have to arrange all T&P, safety equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishappening occurred due to negligence of safety aspects.
Disconnecting burnt LT cable in junction box, taking out cable loop by excavation/dismantling of PCC and reconnection in bus bar of junction box using cable lugs and bus bar of appropriate capacity all as specified and directed by Engr-in-Charge. Note : 1. Rate of excavation, bus bar and cable lugs deemed to be included in item rate. 2. PCC work will be measured and paid separately under relevant item.
Disconnecting and taking down security light fitting, brackets from poles of any height and shifting the fitting in other pole by using old brackets and reconnecting the same complete all as specified and as directed. Note : The rate of Nut, bolts if required will be deemed to be included in quoted rate. 2. Service wire will be measured and paid separately under relevant item.
S&F copper earth continuity conductor or main earthing lead of size 20mmx3mm mounted on porcelain insulator and fixed to wall/pole or buried in ground or any other indicated situation for loop earthing etc complete all as specified and as directed. Note : The rate of porcelain insulator is inclusinve in quoted rate.
S&F swimming pool LED under water lights fittings, 18 Watts, Surface/wall mounted round shape, IP 66 protection with necessary electrical connection, all as specified and directed by Engr-in-Charge
NILESH SUBHASH KARALE
M/s. Shree Shakti Enterprise
SHREE CHAMUNDA CONSTRUCTION WORK
Venus Engineering
GEE CEE ENTERPRISES
baghela construction
NEELKANTHA ASSOCIATE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .