Loading…
Loading…
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
4 Jul 2026, 6:00 pm
GE ARMY
BHUJ
CERTAIN E/M WORKS TO VARIOUS BLDGS OF POCKET A,B, AND C OF BHUJ, KHAVDA AND GANDHIDHAM UNDER GE (ARMY) BHUJ
2026_MES_771640_1
8423
Open Tender
Civil Works
270 days
BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE ARMY
₹90,000
Yes
13 Jun 2026
13 Jun 2026
6 Jul 2026
13 Jun 2026
4 Jul 2026
27 Jun 2026
Taking out & removing old burnt-out windings of electric celling fans/BLDC fan of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by the Engineer-in-charge including insulating material such as illuminous paper, Letherized paper, cotton tape, glass sleeving, insulating varnish etc testing at workshop and transportation to site, connecting and testing on full load to the entire satisfaction of Engr-in-charge of ceiling fan/exhaust fan/Air circulators/Wall mounted fans/Pedestal fan complete all as specified and directed.
Supply only bearing of celling fans for celling fans of 1200/1400mm sweep suitable for different makes /type of fans complete all as specified and directed.
Supply only bushes gun metal suitable for celling fans 1200/1400mm sweep of any size complete all as specified and directed.
Supply only rubber reel type synthetic rubberwith 14.5 mm hole suitable for hooks of celling fans, complete all as specified and directed.
Supply only nuts, bolts and washers of appropriate size for hanging of celling fan including split pins of galvanished iron 1/8" dia, 2" length complete , all as specified and directed.
Supply only top/bottom (Set of Two) canopy of required size complete with tightening screws, complete all as specified and directed.
Supply only down rod 30cm long made out of heavy grade MS pipe with necessory threading at both ends holes as required with suitable matching colour of ceiling fan 1200/1400mm complete all as specified and directed.
Supply only condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of suitable for ceiling fan complete all as specified and directed.
M&L for Painting of celling fan 1200/1400mm sweep AC 230 volts single phase complete in site or at contractor workshop with synthetic enameled white/maching paint by spraying one coat including filling of cavities after cleaning all dust complete all as specified and directed.
Rewinding of exhaust fan 300mm to 450mm sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete , all as specified and directed.
Supply only ball bearing suitable for exhaust fan 300 to 450mm sweep of different make,complete , all as specified and directed.
Supply only exhaust fan frame made out of MS sheet for any make and size of exhaust fan with suitable size of nuts, bolts lugs and washers complete, all as specified and directed.
M&L for Painting of exhaust fan 300 to 450 mm sweep AC 230 volts single phase complrtr with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust,complete all as specified and directed.
Supply only fan blade (set of three), complete with tightening bolts/screws, made of suitable for any make and colour of exhaust fan complete all as specified and directed.
Description all as per item No 12 here - in - before but capacity 4 MFD for exhaust fan of approved make and quality complete all as specified and directed.
Rewinding of table fan/wall mounted/cabin fan of any sweep AC 230 volts single phase with super enameled copper wire of appropriate size including packing insulating material, soldering, varnishing , assembling and testing complete , all as specified and directed.
Supply only ball bearing suitable for table fan/wall mounted/cabin fan of different make, complete all as specified and directed.
Supply only frame suitable for table fan/wall mounted/cabin fan frame made out of MS sheet for any make and any size with suitable size of nuts, bolts lugs and washers complete all as specified and directed.
M&L for Painting of table fan/wall mounted/cabin fan frame complete with synthetic enameled white/grey/matching paint by spraying one coat including filling of cavities after cleaning all dust, complete all as specified and directed.
Supply only fan blade suitable for table fan/wall mounted/cabin fan made out of M S sheet/PVC as per existing model suitable for any make , sweep and colour of celling fans complete all as specified and directed.
Labour only for repairing and attending the complaint of geyser by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed. Note :- (replacement of spare part will be measured and paid separately under appropriate items )
Disconnecting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed.Following items shall be replaced if found defective. Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A"
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size complete all as specified and directed.
(b) Geyser element 1.5 KW, complete , all as specified and directed. Make :- Theata/Venus
(b) Geyser element 2.0 KW, complete , all as specified and directed. Make :- Theata/Venus
(d) Thermostate switch ISI Marked.
(e) S/S inner tank Capacity 25 Ltrs heavy duty .
(f) S/S Copper inner tank capacity 06 ltr heavy duty .
(g) S/S Copper inner tank capacity 50 Ltr heavy duty .
(h) Indicator lamp of any type/colour.
(i) Top and bottom cover of outer body of any type Geyser suitable for 03/06/25/50 lts capacity including two coats of synthetic enamelled paint and preparation of surfaces. complete , all as specified and directed.
(j) CP connection 450mm long nylon braided and double flat with nut and washers both side complete all as specified and directed.
(k) -do- but of size 300mm long.
(l) Copper flexible cable PVC insulated 3 core 40/.0076 All as specified and directed.
(m) Outer body 50 Ltr capacity Geyser sutaible for existing make.
(o) Outer body but 25 ltr capacity Geyser sutaible for existing make.
(p) Pressure release valve ISI marked.
(q) Safty plug of geyser for 25/35/50 Ltr capacity.
(r) Plug top 3pin 15 Amps ISI Marked .
(s) Non return valve 15mm dia pipe brass made ISI marked.
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecnting, dismantling and taking out the non functional Air Conditioner Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Supply and fix in replacement of LED 30 watt 230 V AC outdoor type building security light with high pressure die cast aluminium hosing and heat resistant complete with driver with min 100 lumen/watt efficiency with lamp bracket and ingress protection IP66 including all connected accessories complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 2 TR Capacity for any type of window AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 1.5 TR and S&F compressor sealed unit suitable for 1.5 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
Taking down defective /unserviceable AC compressor of any make of capacity 2.0 TR and S&F compressor sealed unit suitable for 2 TR Capacity for any type of Split AC Single Phase 230 Volts incl brazing to suction & discharge line vaccum testing with and including charging of refrigerant gas as per existing & testing incl disconnecting and taking out existing defective compressor of any description & in any position complete all as specified and directed.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
(a) Split type AC 1.5/2 Ton capacity.
(b) Window type AC 1.5/2.0 Ton capacity
Supply only starting relay complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/2” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 3/8” completes all as specified and as directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 1/4” completes all as specified and as directed.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed. Note- Any additional copper tubing required for the work is included in the item)
S&F in replacement of remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR complete all as specified and directed.
Supply only thermostats of of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only overload protector of followings :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Preparation of old painted surfaces of the following appliacnes, painting with two coats of synthetic enamel paint by spraying all as directed by Engr-in-charge for :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC 1.5/2 Ton capacity.
Supply only internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity
(b) Split type AC of any make and capcity 1.5/2 ton.
Supply only condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC of any make capactiy 1.5 Ton cap.
(b) Split type AC of any make and capcity 1.5/2 ton.
Supply only bottom tray of window type ACs 1.5/2.0 Ton capacity of any make complete all as specified and as directed by Engineer-in-Charge.
Supply only heavy duty PVC flexible pipe with necessary jubilee clamps for split ACs/Window ACs drains of size :-
(a) 15mm dia bore.
(b) 20 mm dia bore.
Supply only PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed by Engineer-in-Charge.
M&L, for providing rubber foam heavy duty insulation tube over the existing copper tubing of any length at any location in replacement of worn out insulation including fixing with cable tie, clamping all as required at site, complete all as specified and directed by Engr-in-Charge.
Supply only front grill of window type AC as per sample, complete all as specified and directed by Engr-in-Charge.
Supply only air filters of split type AC of 1.5/2.0 TR capacity as per existing pattern, complete all as specified and directed by Engr-in-Charge.
Supply only new coling fan motor for window type AC1.5TR/2TR, complete all as specified and directed by Engr-in-Charge.
Supply only new cooling fan motor for split type AC of 1.5/2.0 TR capacity, complete all as specified and directed by Engr-in-Charge.
Supply & Fix in replacement MS stand factory made suitable for condensing unit of split type AC duly powder coated all as specified and as directed by Engineeer-in-Charge.
supply and fix swing motor suitable capacity for window/split AC complete all as specified and as directed by Engineeer-in-Charge.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure for Water coolers 40 to 150 ltrs capacity.complete all as specified and directed by Engr-in-Charge for the following appliances:-
Supply only starting relay of Water coolers 40 to 150 ltrs capacity. complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
Supply only thermostats for water coolers 40 to 150 ltrs capacity.
Supply only overload protector Water coolers 40 to 150 ltrs capacity.
Preparation of old painted surfaces of the for Water coolers 40 to 150 ltrs capacity., painting with two coats of synthetic enamel paint by spraying all as directed by Engr-in-charge.
Supply only condenser unit for water coolers 40 to 150 ltrs capacity. including making of all connectiions as specified and directed by Engr-in-charge
Supply only cooling coil for water coolers 40 to 150 ltrs capacity.of following :-
Supply only top cover gasket of water cooler 40 to 150 ltrs capacity.
Supply only internal wiring kit complete for water coolers 40 to 150 ltrs capacity
Supply only condenser fan motor complete for Water coolers of any make and cap 40 to 150 ltrs capacity. with necessary mounting bracke to and base frames
S&F in replacement of water tap for water cooler of capacity 40 Ltrs / 150 Ltrs, complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable water cooler (capacity 40 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
S & F in replacement of float valve assembly Complete suitable for water cooler of any size/cap Non metallic body complete all as specified and directed by Engr-in-Charge.
M&L for checking for leakages, creating vacuum, charging of R-410 gas in the unit to the required pressure complete Refrigerator of 165 to 310 ltrs capacity. all as specified and directed by Engr-in-Charge for the following appliances:-
Supply only starting relay Refrigerator of 165 to 310 ltrs capacity. complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
Supply only thermostats for Refrigerator of 165 to 310 ltrs capacity
Supply only overload protector Refrigerator of 165 to 310 ltrs capacity. of followings :-
Preparation of old painted surfaces of the following appliacnes, painting with two coats of synthetic enamel paint by spraying for refrigerator of 165 to 310 ltrs capacity. all as directed by Engr-in-charge for :-
Supply only condenser unitRefrigerator of 165 to 310 ltrs capacity. including making of all connectiions as specified and directed by Engr-in-charge
Supply only cooling coil Refrigerator of 165 to 310 ltrs capacity.
Supply only internal wiring kit complete sutaible for Refrigerator of 165 to 310 ltrs capacity.
Supply only magnetic door gasket of refrigerant 165 to 310 Ltrs cpacity.
Supply only ice tray with PVC cubicle separater.
Supply only cabinet bulb of refrigerators of suitable size and capacity.
Taking down defective /unserviceable refrigarator (upto capacity 260 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
Taking down defective /unserviceable Refrigrator (upto capacity 320 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
M&L for checking for leakages of Deep freezers of Upto 425 ltrs capacity., creating vacuum, charging of R-410 gas in the unit to the required pressure complete all as specified and directed by Engr-in-Charge for the following appliances:-
Supply only starting relay for Deep freezers of Upto 425 ltrs capacity. complete all as specified and directed by Engr-in-Charge. for the following appliances:-Make- Hitech
Supply only capacitors of the following capactities for ACs, water coolers, Refrigerators, Deep freezers etc as per site requirement.
Supply only overload protector for Deep freezers of Upto 425 ltrs capacity.
Preparation of old painted surfaces Deep freezers of Upto 425 ltrs capacity. , painting with two coats of synthetic enamel paint by spraying all as directed by Engr-in-charge
Supply only condenser unit for Deep freezers of Upto 425 ltrs capacity. including making of all connectiions as specified and directed by Engr-in-charge
Supply only cooling coil for Deep freezers of Upto 425 ltrs capacity.
Supply only internal wiring kit complete sutaible forDeep freezers of any make & cap 200 to 425 ltrs capacity.
Supply only condenser fan motor suitable for Deep freezers of any make & cap 200 to 425 ltrs capacity. complete with necessary mounting bracke to and base frames for :-
Taking down defective /unserviceable Deep freezers (capacity upto 425 ltrs) compressor of make tecumseh/kirloskar/emerson , transporting to company authorized outlet , collecting company repaired compressor of same make in replacement of unserviceable compressor, transporting back to site, refixing including brazing work etc, pressure testing & establishing vacuumed for dehydration complete all as specified and directed by Engr-in-Charge.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank etc, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of desert cooler fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed by Engineer-in-Charge.
Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed by Engr-in-charge.
Supply & fixing in replacement of capacitor 4 mfd make Usha/Universal/Epcos
Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness as directed.
Supply & fixing in replacement of old rusted front panel with show grill of desert cooler with new grill made out of GI sheet 22 SWG complete with front show plate with ON/OFF switch for pump & four speed regulator for fan of approved make all as specified and as directed by Engr-in-Charge.
S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed by Engr-in-Charge.
Supply and fixing indoor unit of split type AC 2 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor,swing blade filter, PCB, Thermostate etc complete all as specified and as directed by Engineer-in-charge. Make- Voltas/ LG
Supply and fixing in replacement to worn out door unit of split type AC of cap 2 TR. comprises of condensor, condenser motor, condensor fan and blade , capacitor, suction, discharge valve, outer cover duly powder coated etc complete all as specified and as directed by Engineer-in-Charge.Make-Voltas/ LG.
Supply and fixing ceiling fans complete with blades, down rods, remote and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete.
Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 250 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450 mm sweep with, blades, and frame and louvers including making hole for fixing exhaust fan , the disturbed surface to be matched with existing complete.
Supply& Install Desert cooler steel body , electric driven (single phase), having nominal air flow capacity of 4000 CFM , Honeycomb cooling pads design, ice chamber,water level indicator,Four way air deflection,Easy Mobility complete.
Taking down carefully copper/alumunium point wiring for light, fan, bell, socket or power complete including fittings such as switches, ceiling roses pendents regulators, sockets and tube light fittings etc, removing materials from site or for reuse refixing and making good distrubed surface of wall, floors etc all as specified and directed.
-ditto- all as per item No 117 above but for one 3 pin switch socket 5 Amp single pole one way on same board with other switches including continuous 1.5sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete all as specified and directed.
-ditto- all as per item No117 herein above but for one 3 pin switch socket 5 Amp independent complete all as specified and directed.
-ditto- all as per item No 117 above but for 3 pin switch socket outlet 15 Amp independent with cable 2.5 sqmm unsheathed stranded 1100 Volts grade complete with 2.5 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
-ditto- all as per item No 117 above but for 3 pin switch socket outlet 15 Amp independent with cable 4.0 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
All as per item Ser No 122 above but for one 3 pin socket 5 Amp single point pole one way on same board with other switches including continuous 1.5 sqmm PVC insulated copper conductor earth wire to common wire earth and connecting to earth dolly complete.
All as per item Ser No 122 above but for one 3 pin socket 5 Amp independent complete all as specified and directed
-ditto- all as per item No 122 above but for 3 pin switch socket outlet 15 Amp independent with cable 4.0 sqmm unsheathed stranded 1100 Volts grade complete with 4.0 sqmm PVC insulated earth wire and connecting to earth dolly complete all as specified and directed.
Supply and fixing ceiling fan electronic regulator 100 watt step type 230V, all as specified and directed.
Supply and fix in repair switch piano type 5 Amp single pole one way complete all as specified and directed.
Supply and fix in replacement of switch modular type 6 amp single pole one way 230 V all as specified and directed.
Supply and fix in replacement of switch modular type 16 amp single pole one way 230 V all as specified and directed.
Supply and fix in replacement of socket outlet multi purpose 5 pin 6 Amp modular type complete all as specified and directed.
Supply and fix in replacement of socket outlet multipurpose 3 pin 16 Amp and 3 pin 6 amp modular type 2 in 1 complete all as specified and directed.
Supply and fixing in replacement of ceiling fan regulator modular type 120 watts all as specified and directed.
Supply and fix in replacement of ceiling rose surface backelite three terminal complete all as specified and directed.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 20 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and fixing integrated sleek extruded LED channel with acrylic cover 10 watt with white light including with driver and prewired complete including 0.5 sqmm 3 core flexible wire connecting from ceiling rose complete all as specified and difected.
Supply and install hi wall inverter type split units indoor and outdoor complete with cordless remote control unit and with in built air filter for better indoor air quality with minimum 5 star rating single phase 240 Volts 50 HZs of 1.5 Ton complete with all fixing acessories. (a) Room evaporator indoor unit with speed blower fan of approipriate capacity including PCB , thremostatic control , air filter and drain for condensing water. (b) Outdoor condensing unit of capacity 5175 Kacl/Hr capacity with condensor fan motor of appropriate capacity - 01 No. Air cooled condensor of capacity 1.5 TR - 01 No.Shall be installed outside the building on and including suitable factory made mild steel brackets fixed on wall using fastners for fixing and installing of ACs. (c ) Refrigerant cooper pipe of suction and discharge line with insulation , condensing water drain pipe & protected by suitable size of flexible PVC conduit withy control valves & safety acessories invcluding complete wiring for evaporator & condensing unit with fixing of suitable size of copper cable. (d) Making good the disturbed surface to match with the existing surface complete all as specified and directed.
Supply and fix Water heater storage type, electric,capacity 25 litres.BEE 5 star rate complete with all fixing acessories, temperature display complete all as specfied and directed.
Supply and fix in replacement of BLDC fan PCB(Control board ) complete all as specfied and directed.
Note :- (1) The contractor shall keep all items readily available at site, which is required for urgent repair works of appliances.
(2) In case of absence of manpower without providing suitable replacement an amount of Rs 1000/- per day shall be recovered as liquidated damage per person per day from the bill.
(4) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost. Workshop shall be setup for rewinding/ repair of ceiling fan, exhaust fan, wall mounted fan, refrigerator, deep freezer & desert cooler etc. Rewinding machine should be installed in workshop with the latest configuration.
(5) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(6) The electrician on duty round the clock will have to be available at the site service centre created by the contractor & should have mobile phone. In case of absence of electrician, Rs 500/- will be levied as penalty for each instance.
(7) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.
(8) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(9) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(10) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(11) All repair and maintenance related complaints shall be attended within two hoursfailing, which a recovery of Rs 500/- per event per hour shall be made from the subsequence payment of the contractor.
(12) The date of repair, unit name & serial number shall be mentioned in neat sticker in the appliances after repair.
(13) Contractor is to collect the faulty appliances from units & return them after repair within a week. No separate charges shall be given for transportation.
(14) To carryout the serving of AC, refrigerator, deep freezer & water cooler, following T&P should be brought at site (service centre):-
(i) Drilling machine for making hole in wall.
(ii) Jet spray for cleaning of indoor and outdoor units.
(iii) Vacuum cleaner and blower
(iv) Ref mechanic tools kit
(16) The same nature of complaints in same location shall be counted as one complaint in internal electrification. Job card and complaint register for entry of complaints shall be provided at his/ her own cost.
(17) The contractor provide test certificate of material to be incorporated in the work.
(18) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(19) In the event of the contract work getting delayed due to reasons attributable to the contractor, the department shall be levying the penalty at the rate of 1% per week to the maximum of 10% of the contract value.
(20) Contractor shall carry out all test. The equipments shall conform to Indian standards.
(21) Contractor shall identify the real cause of burned winding of fan motor. Winding problems that are identified should be documented. Then, winding of fan motors shall be cut/ removed completely in presence of officials. Rewinding of same shall be carried out with proper copper gauge wire.
(22) Work diary & hindrance register of maintained by the contractor. The both shall be deposited to department daily.
(23) Job card /Docket shall be maintaned properly mentioning as below: a) service Number b) Name c) Rank d) unit e) Date Format of docket/job card shall be provided to contractor. Date of receiving & Date of resolving with time shall be endosrsed on job card. (24) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge. (25) Stationery such as complaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor
Taking down carefully existing unserviceable aluminum/copper point wiring (light, fan, socket or power) of any description & in any position complete including all fittings & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc including taking out and removing serviceable fittings/fixtures and making good the disturbed surface of walls, floors, ceiling etc. to match with the existing surfaces complete all as specified and directed.
One light/buzzer point controlled by one; one way switch complete all as specified and directed.
One fan/exhaust fan point controlled by one, one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch complete all as specified and directed.
One 3 pin socket out let 5 amp point on the (same board) with other switches complete all as specified and directed.
All as per item No. 140 here-in-before but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board complete all as specified and directed.
S&F ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed.
Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular bell switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed.
Supply and fix modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed.
S&F in repair modular socket 6 Amps / 16 Amps , 2/3 pin combined 2 module complete all as specified and directed.
S & F in repairs earth plug and socket, single pole, neutral sheet metal enclosures with a two pin, plug and socket 20Amp, 240 volts with and including one MCB, SP, 20A, 240 Volts as per complete all as specified and directed.
S&F fan regulator electronic, step type, suitable for ceiling fans of any capacity, pre-wired 230 volts AC 50Hz supply 100Watt complete all as specified and directed.
S & fix condenser/capacitor suitable for 230 volts singls phase celling fan 1200mm/1400 sweep of approved make and quilty of capacity 2.5 MFD complete all as specified and directed.
S&F in replecement bell Multi music type , 240 Volt , Single Pole ISI marked complete all as specified and directed. Make :- ANCHOR
S & F in replacement elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
S & F in replacement 10 W mirror light having indirect up down light for mirror and as well light application with CCT 6000K, including LED Bulb/Module and Electrical connection with 3 core flexible wire of appropriate size from ceiling rose to the tubelight fitting complete all as specified and directed.
S&F lamp holder PVC / Polycarbonate type with cord grip cap suitable for LED lamp fitting complete all as specified and directed.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , SPN & TPN distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used V-TPN (Triple pole and neutral) 6 way, 415 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, single door type complete all as specified and directed. ( Note : Double Door)
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 08 way, 240 Volts, sheet metal powder coated, IP 42 protection with 100 Amps rated bus bar, single door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 04 way, 240 Volts, sheet metal powder coated, IP 42 protection with 100 Amps rated bus bar, single door type complete all as specified and directed.
Supply and fixing MCB TPN, 63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
Supply and fixing MCB SPN, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.
S&F MCB single pole, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed
Taking Down Old Unserviceable Submain wiring complete including all accessories and making good the disturbed surfaces complete all as specified and directed.
M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 4 Sqmm drawn through PVC conduit/casing capping including accessaries with 4sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting upcomplete all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.
M/L for Sub main wiring with 2 runs of PVC insulated unsheathed multi stranded single core copper conducter 6 Sqmm drawn through PVC conduit/casing capping including accessaries with 6 sqmm PVC insulated earth wire fixed to the existing wall with saddles, screws etc after removing the unserviceable wiring and connecting upcomplete all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit/Casing & Caping will be measured as one length.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core 0.5 sqmm flexible copper conductor cases of suitable size complete all as specified and directed. Note : Include warm &natural&cold white as per site requirement)
Supply and fix street light timer panel of capacity 3 phase, 5KW , IP 65, made of polycarbonate,UV ray protected, and contactor of capacity 40A complete all as specified and directed.. (Note : suitable bracket of pole with nut and bolt include)
Supply and fixing in replacement of LED Bolard new generation ,energy saving, environmental friendly , long life aesthetically designed aluminum landscape for diffused lighting with high power LEDs ,IP65 protection and impact of capacity 20 Watt including suitable PCC foundation complete all as specified and directed.
Supply & Fixing in repair LED Flood Light 170 watt suitable for High Mast lifht 230V AC putdoor type with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant complete with driver & lamp complete all as specified and directed. (Note :including taking down of old unsv floof light for existing high mast light and installation new flood light on high mast pole.)
Supply and fixing ceiling fans complete with three blades, down rods, regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 220 CFM with service value 6.00 BEE, five star rated with squirrel cage induction motor Copper Winding complete all as specified and directed. (Note :Old ceiling Fan to be deposited in MES store yard for repair )
Supply and fix in repair exhaust fan in repair made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep upto 300 mm complete all as specified and directed. Note : suitable E/F place according to site )
Supply & fix exhaust fan, steel body AC single phase 230/ 240 volt of size 300 mm sweep with blades, frame and louvers complete all as specified and directed.
Supply and fix desert cooler electric driven ,single phase motor of suitable size with ISI marked, having nominal air flow capacity of 4000 CuM per hour (or nearest size).Plastic/PVC Body Honeycomb Cooling Pads specially processed anti-bacterial, anti-erosion, antideformation with hydrophilic property; absorb remainder dust particles, auto swing grill, Tank Capacity not less than 55 Ltrs, completely Collapsible Louvers,water circulating pump of suitable size , including rolling arrangement on wheels for moving purpose. Rated power not less than 160W, volt rating 220-240 volts complete all as specified and directed. (Make :- Havells/Symphony/Crompton)
Disconnecting electrically and mechanically the existing geyser of any description, any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconnecting existing cold & hot water pipe connections, strip opening of geyser for descaling of tank, element, thermostate, inlet/outlet water pipe connection etc using suitable chemical/wire brush, brazing/soldering/welding of inner tanks for stopping any leakage, replacement of unserviceable parts reassembling the same after, repair/descaling, fixing in position incl, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed. Note : U/s parts replaced with new one shall be measured and paid for separately as "Supply only" under appropriate item of Sch "A". Supply only of following items for geyser complete.
(a) Apparatus plate heavy duty rubber gasket suitable for 03/06/25/50 Ltr of any size and directed.
(b) Geyser element 1.5 KW, complete all as specified and directed. Make :- Theata/Venus
(c) Geyser element 2.0 KW, complete all as specified and directed. Make :- Theata/Venus
(d) Thermostate switch ISI Marked complete all as specified and directed.
(e) S/S inner tank Capacity 25 Ltrs heavy duty complete all as specified and directed.
(f) S/S Copper inner tank capacity 06/03 ltr heavy duty complete all as specified and directed.
(g) Indicator lamp of any type/colour.
(h) Top and bottom cover of outer body of any type Geyser suitable for 03/06/25/50 lts capacity including two coats of synthetic enamelled paint and preparation of surfaces complete all as specified and directed.
(j) CP connection 800 mm long nylon braided and double flat with nut and washers both side complete all as specified and directed.
(k) Copper flexible cable PVC insulated 3 core 40/.0076 complete all as specified and directed.
(l) Outer body but 25 ltr capacity Geyser sutaible for exesting make complete all as specified and directed.
(m) Pressure release valve ISI marked complete all as specified and directed.
(n) Safty plug of geyser for 25/35/50 Ltr capacity complete all as specified and directed.
(o) Plug top 3pin 15 Amps ISI Marked complete all as specified and directed.
(p) Non return valve 15mm dia pipe brass made ISI marked complete all as specified and directed.
M&L for cleaning after taking down complete body including fitting and fixtures of desert coolers of capacity 4000/5000 cum/hours of any make with wire including removal of all sludge, loose paint dirt etc and preparationand cleaning of surface for painting and applying two coats of synthetic enamenl spray paint inside and outside surfaces and applying two coats rubber seal paint inside the water tank etc, complete all as specified and directed.
(a) S&F in replacement Submersible PVC pump for desert cooler 230 volt single phase 50 HZ complete all as specified and directed.
(b) S&F in replacement of fan motor copper wound for desert cooler for operation on AC single phase 230 / 250 volts 50 HZ 1440 RPM complete all as specified and directed.
(c) Supply & replacement of wood wool pad ( Set of three) heavy duty for desert cooler complete all as directed.
(e) Supply & fixing in replacement of capacitor 4 mfd make Usha/Universal/Epcos complete all as specified and directed.
(f) Supply & fixing in replacement desert cooler fan blades made of galvanised iron sheet of appropriate thickness as directed.
(g) S&F in replacement of 3 Pin Top, 5 Amp for desert coolers, complete all as specified and directed.
Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Disconnecnting, dismantling and taking out the non functional Air Conditioner window type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
Disconnecnting, dismantling and taking out the non functional Air Conditioner Split type of any description, any make and in any position 1.5 TR/2.0 TR capacity Single Phase 50 HZ, strip opening, coil of indoor unit and brazing the discharge and suction line by and checking & retightening of all electrical connections. Replacement of minor part such as nut, bolts, screws, washers, fixing properly bracket housing of capacitors, relay incl replacment of unserviceable parts, cleaning and servicing of the AC with using caustic soda/detergent powder solution, taking out and removing unserviceable/defective wiring & parts incl painting the bottom with one coat of black synthetic enamel paint, replacement of unserviceable and defective parts brazing reassembling and testing of the AC complete all as specified and directed. Note :- (i) The replacement of defective/nonfunctional parts shall be measured & paid for seperatly as` supply only' under appropriate item of Schedul A and fixing charges for new items are deemed to be included under this item. (ii) The rate for above items are deemed to include for transpotation of AC to & from workshop as approved by Engr-in-Charge for necessary unserviceable screws/nuts/bolts /washer/packing etc with new one. (iii) Charging of gas if required shall be measured and paid for separatly under appropriate item of schedule A however vacuum and pressure leakage testing with nitrogen (N2) if any required is deemed to be included under the units rate quoted by the contractor for this item.
M&L for servicing of following appliances comprising of through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts etc to make the unit for smooth operation for :- Note :- (replacement of spare part will be measured and paid separately under appropriate items )
(a) Water coolers 40 to 150 ltrs cooling capacity complete all as specified and directed.
(b) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
(c) Deep freezers of Upto 425 ltrs capacity complete all as specified and directed.
Supply only heavy duty PVC flexible pipe with necessary jubilee clamps for water cooler/split ACs/Window ACs drains of size :-
(a) 15mm dia bore complete all as specified and directed.
(b) 20 mm dia bore complete all as specified and directed.
Supply and fixing of inverter /non inverter type AC (Indoor or outdoor unit )PCB of split type AC Cap 1.5/ 2 TR as per existing make and model. Complete all as specified and directed.
Supply only new coling fan motor for window type AC 1.5TR/2TR, complete all as specified and directed.
Supply only new cooling fan motor for split type AC of 1.5/2.0 TR capacity, complete all as specified and directed.
S&F in replacement of remote control ( micro- processor) unit suitable make of split type AC 1.5/ 2 TR complete all as specified and directed.
Supply only condenser unit of the following appliances including making of all connectiions as specified and directed by Engr-in-charge following :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Split type AC 1.5/2 Ton capacity. complete all as specified and directed.
(c) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
(e) Deep freezers of Upto 425 ltrs capacity complete all as specified and directed.
Supply only cooling coil of following :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Split type AC 1.5/2 Ton capacity complete all as specified and directed.
(c) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
(e) Deep freezers of Upto 425 ltrs capacity complete all as specified and directed.
Supply only internal wiring kit complete sutaible for following :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(c) Split type AC of any make and capcity 1.5/2 ton complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity complete all as specified and directed.
Supply only condenser fan motor complete with necessary mounting bracke to and base frames for :-
(a) Window type AC 1.5/2.0 Ton capacity complete all as specified and directed.
(b) Water coolers 40 to 150 ltrs capacity complete all as specified and directed.
(c) Split type AC of any make and capcity 1.5/2 ton complete all as specified and directed.
(d) Refrigerator of 165 to 310 ltrs capacity complete all as specified and directed.
(e) Deep freezers of any make & cap 200 to 425 ltrs capacity complete all as specified and directed.
Supply only capacitors of the following capactities for ACs water coolers, refrigerators, Deep frizers etc as per site requirement.
(a) 6 Mfd complete all as specified and directed.
(b) 10 Mfd complete all as specified and directed.
(c ) 36 Mfd complete all as specified and directed.
Supply, installation including brazing, jointing copper tubing superior quality of dia 5/8” completes all as specified and as directed.
M&L for shifting of split type AC from one location to other location including fixing evaporator unit with gitties/fastner, cutting wall/concrete incl arrangement of T&P for laying copper tubing, positioning condensing unit, laying copper tubing incl brazing work, connecting drain pipe, making good disturbed surface complete all as specified and as directed. Note- Any additional copper tubing required for the work is included in the item)
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
Please Enable Macros to View BoQ information
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
TENDER8423.pdf
Tender Documents • 0.56 MB
PS8423.pdf
Tender Documents • 0.62 MB
LISTOFMAKE.pdf
Tender Documents • 0.20 MB
BOQ8423.xls
Tender Documents • 0.49 MB
Download all tender documents and submit your bid