Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.4 L+₹57,680 (1.61%)Rejected-Finance WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L2 | Rejected-Finance Being L2 other than lowest bidder | |
| 3 | L3₹37.5 L+₹1.7 L (4.68%)Rejected-Finance NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | L3 | Rejected-Finance Being L3 other than lowest bidder | |
| 4 | L4₹41.0 L+₹5.2 L (14.5%)Rejected-Finance | L4 | Rejected-Finance Being L4 other than lowest bidder |
Tender Value
₹42.9 L
EMD Value
₹85,900
Closing Date
19 Feb 2020, 6:00 pmClosed
GE(North) Tezpur
GE (North)Tezpur Solmara PO-Dekargaon Dist - Sonitpur Assam - 784501
REWIRING INCLUDING REPAIR/REPLACEMENT OF FITTING AND FIXTURE OF INTERNAL ELECTRIFICATION OF AGE CHARDUAR AREA UNDER GE(N) TEZPUR
2019_MES_304709_2
GE(N)/TEZ/2019-20/8375
Open Tender
Miscellaneous Services
Item Rate
240 days
GE(North) Tezpur
As per NIT
8 documents required · 8 mandatory
₹500
GE (North)Tezpur
₹85,900
Yes
2 Apr 2020
8 Feb 2020
20 Feb 2020
8 Feb 2020
19 Feb 2020
10 Feb 2020
8 Feb 2020 - 10 Feb 2020
Amount
Note 1: (Applicable for all parts/items) : The bidders/contractors are advised to read tender document, all drawings & all corrigendum/amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected. Fixed credit has been given in technical documents which shall be taken into account during acceptance of bid/tender.
Taking down carefully copper/aluminium point wiring (light, fan socket or power ) complete fitting such as switches , ceiling rose pendent , regulators , sockets light fitting etc to be measured separately ) removing material from site and making good disturbed surface of wall floor etc complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade drawn in and including PVC casing and capping of size 30/32 mm fixed to wall ceiling including PVC closed recessed boxes ISI marked with 3.00 mm thick plastic laminated sheet top cover for mounting of switches, sockets etc incl 1.50 sqmm (nominal area) PVC insulated and sheathed multistranded copper conductor cable FRLSH 1100 volts grade single core earth continuity conductor connected to common earth dolly complete all as specified and as directed. for following:-
One light /fan point controlled by one switch.
One bell /buzzer point controlled by one buzzer switch.
One 3 pin socket outlet 5 Amps on same board. With other switches.
One 3 pin socket outlet 5 Amps on indpendent board
All as per item No. 3.00 above but with 2.50 sqmm single core multistranded copper conductor cable for 3/5 pin 15 Amp socket outlet on independent board.
S&F in repair switch piano flush type single pole, one way, 5/6 Amps complete all as specified and directed.
S&F in repair socket out let 2 in one 3/5 pin 5 Amps, 240 Volts flush type, complete all as specified and directed.
S&F in repair switch socket combination 2 in one , 5 pin 5 Amps flush type, universal complete all as specified and directed.
S&F in repair switch socket combination 2 in one , 5 pin 5 Amps & 15 Amps flush type, universal complete all as specified and directed.
S&F in repair bell push flush type 5 Amps complete all as specified and directed.
S&F in repair call bell Ding dong AC 230 Volts single pole complete all as specified and directed.
S&F in repair lamp holder PVC/Polycarbonate type with back plate suitable for batten fitting, straight or angular type complete all as specified and directed.
S&F in repair fan regulator electronic step type 230 V AC 100/150W complete all as specified and directed.
S&F in repair ceiling rose,surface bakelite 65x50mm two to three terminal complete all as specified and directed.
S& F in repair surface and wall mounted E-lite LED Curve with wide angle profile high lumen with efficiency of 100 llumens batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate housing & integrated electronic driver including LED tube light 20 watt 6500K 4 feet complete all as specified and directed. Make: Jaquar Cat No- LGLJ01X020XC or equivalent of Philips/Wipro.
S&F in repair environmental friendly ultra modern energy saving surface mounted decorative round plastic bulk head LED bulk head luminaries suitable for 9 watts LED 6000K and connecting up electrically complete all as specified and as directed. Make: Jaquar /Philips/Wipro.
S&F in repair Recess mounted round shaped LED downlighter with durable housing with AIuminium heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 15 W LED 6000K complete all as specified and directed.Make: Jaquar /Philips/Wipro.
S&F in repair Recess mounted round shaped LED downlighter with durable housing with AI heat sink with PC diffuser in white powder coated finish with integrated driver to give glare free light with removable driver 25 W LED 6000K complete all as specified and directed.
S&F in repair Environmental friendly,slim surface mounted round LED panel die cast body with premium diffuser to ensure glare free and even distibution of light for 18 watt LED 6000K lamp including lamp complete all as specified and directed.
S&F in repair 9W LED new adore 9W B22 cool day light ball lamp all as specified and directed. Make: Jaquar /Philips/Wipro.
S&F in repair 14W LED new adore 14W B22 cool day light ball lamp all as specified and directed. Make: Jaquar /Philips/Wipro.
Note for Ser No 14 to 20 above: (i) Every fitting will be marked/ printed with "CA No" & "GE(North) Tezpur' (ii) 02 Years manfuctures warranty shall be submitted by the contractor.
S&F in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 4 way with 200 amps rated bus bar SPN double door complete all as specified and directed.
S&F in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 8 way with 200 amps rated bus bar SPN double door complete all as specified and directed.
S&F in repair sheet metal enclosure for DB’s when MCB’s to be used of 240 volt 2 way with 200 amps rated bus bar SPN double door complete all as specified and directed.
S&F in repair MCB single pole 5 amps to 32 amps , C series complete all as specified and directed.
S&F in repair MCB single pole & neutral 240 volts 5/6 to 30 Amps,10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.
M&L for submain wiring with two runs of PVC insulated multistranded,copper coductor of size 4 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 4 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 4sqmm cable+ 1 run of 4sqmm earthed cable+ 1 run of casing capping shall be measured as one unit.
M&L in repair for submain wiring with two runs of PVC insulated multistranded, copper coductor of size 6 Sqmm cable single core 1100 Volts Grade and one run of earth continuity conductor cable of 6 Sq mm solid strand cable drawn in and incl 30/32 mm PVC casing caping complete all as specified and as directed. Note:- 2 run of 6sqmm cable+ 1 run of 6sqmm earthed cable+ 1 run of casing capping shall be measured as one unit.
S&F in repair metal clad socket out let with MCB single pole 20 Amp including sheet metal enclosure complete fixed on flat iron 32x6 mm or 2nd class hard wood wooden board including complete electrical connection by proper size of copper lugs complete all as specified and directed.
S&F in repair MCCB, AC 415 V, 100 Amp,16 KA 4 Pole fixed thermal and magnetic setting complete all as specified and directed.
S&F in repair MCCB, AC 415 V, 200 Amp,16 KA 4 Pole fixed thermal and magnetic setting complete all as specified and directed.
M&L in repair for providing fan hook made out of MS round bars of 20 mm dia cut to size and made to shape hanging from roof supporting bars to the required length up to the ceiling level including shackle type rubber bush, MS clamp, nuts, bolts, washers etc, complete all as specified and as directed.
S&F ceiling fan 1200 mm sweep AC 230 volts single phase including making connection with three core PVC insulated 1100 volts grade multi stranded copper wire of appropriate size including testing complete all as specified.
S&F in repair twin twisted flexible cable, PVC insulated with stranded copper conductor of size 14/0.0052, AC 1100 volts grade complete all as specified and directed.
S&F in repair twin twisted flexible cable, PVC insulated with stranded copper conductor of size 14/0.0076, AC 1100 volts grade complete all as specified and directed.
M&L for detecting faults in internal wiring/LT distribution system in OTM accn under AGE Charduar(Sonaipam,Thakurbari,Phulbari,Charduar,Amaribari & TCP Bhalukpong) and rectifiying the defects for restoring supply including taking down of old unserviciable defective electrical accessories in replacement complete all as specified and directed. NOTE S&F Rate for any item shall be measured and paid under respective item of schedule . Essential material like, insulation tape,screws and all tools required for carrying out the works and insutruments to the defect fault shall be deemed to be included in the quoted rate The work is of day to day maintenace, required Electricians and Helper has to be present daily to carryout the above work. Complaints in writting pertaining to internal wiring/LT distribution system shall be collected from concern JE at AGE Charduar office for various areas under AGE Charduar in writting during the hours as fixed by the Engr-in-Charge and detecting faults in internal wiring/LT distribution system in any area under AGE Charduar and rectify the fault to restore the elect supply in all respect and upto entire satisfaction of Engr-in-Charge and depositing the complaint slip to concern JE on same day duly singned by the concern user/complainant. Minimum Three shift of 01xSkilled Electricion and 01xhelper along with necessary T&P shall be required to attend emergency breakdown and repairs/maint of the same on any day and time during the currency of contract (including Sundays and holidays 24x7 on any circumstance) for various pockets under AGE Charduar. The Electricians/Helpers deployed shall have requsite experience of working on Live HT/LT lines/wiring of various circuits. (vii) The contractor shall be solely responsible for any accident or mishap due to any uncertain reason and no compensation in this regard shall be paid by the department for reason whatsoever. (viii) Contractor shall be bound to follow the instructions as asked by the concern unit and he himself shall be responsible for any lapses in security/information in national interest
S&F PVC switch boards ,with 3mm thick plastic laminated sheet cover of size 100 mm X100mmX50 mm deep complete all as specified and directed.
S&F PVC switch boards ,with 3mm thick plastic laminated sheet cover of size 175 mm X100mmX50 mm deep complete all as specified and directed.
S&F PVC switch boards ,with 3mm thick plastic laminated sheet cover of size 200 mm X150mmX50 mm deep complete all as specified and directed.
S&F PVC switch boards ,with 3mm thick plastic laminated sheet cover of size 250 mm X200mmX50 mm deep complete all as specified and directed.
S&F in repair bi-pin holder for FTL fittings 36 / 40 W all complete all as specified and directed.
S&F in repair bi-pin holder for FTL fittings 28W complete all as specified and directed.
S&F in repair fan capacitor, AC 230 V, 2.5 MFD complete all as specified and directed.
S&F in repair fan capacitor, AC 230 V, 3.15 MFD all as specified and directed.
S&F in repair PVC casing & capping with fittings, ISI marked, 25 mm size complete all as specified and directed.
S&F in repair PVC casing & capping with fittings , ISI marked, 32 mm size complete all as specified and directed.
S&F in repair 1.5 Sqmm PVC Cable FRLSH PVC insulated, single core,copper conductor for voltage grade upto 1100 V Conforming to IS-694:2010 complete all as specified and directed.
S&F in repair 2.5 Sqmm PVC Cable FRLSH PVC insulated, single core,copper conductor for voltage grade upto 1100 V Conforming to IS-694:2010 complete all as specified and directed.
S&F in repair 4.00 Sqmm PVC Cable FRLSH PVC insulated, single core,copper conductor for voltage grade upto 1100 V Conforming to IS-694:2010 complete all as specified and directed.
S&F in repair 6.00 Sqmm PVC Cable FRLSH PVC insulated, single core,copper conductor for voltage grade upto 1100 V Conforming to IS-694:2010 complete all as specified and directed.
S&F service cable passing through service bracket 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 6 Sqmm including taking down old complete all as specified and directed.
S&F service cable passing through service bracket 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 mtr apart incl 4mm suspension wire one twin core cable of size 10 Sqmm including taking down old complete all as specified and directed.
S&F New generation, post-top, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs 25watt as light source complete all as specified and directed. Make: Jaquar /Philips/Wipro.
Supply only surface and wall mounted LED tube light Curve with wide angle profile high lumen with efficiency of 100 Lumens batten extruded aluminium housing provided for efficient heat dissipation with polycarbonate housing & integrated electronic driver including LED tube light 20 watt 4 feet complete all as specified and directed. Make: Jaquar Cat No- LGLJ01X020XC or equivalent of Philips/Wipro.
Supply only LED lamps 9 watts 230 volts PF>0.9, CRI>80 beam angle>120 degree complete all as specified and directed. Make: Jaquar /Philips/Wipro.
Supply only LED lamps 12 watts 230 volts PF>0.9, CRI>80 beam angle>120 degree complete all as specified and directed. Make: Jaquar /Philips/Wipro.
Supply only LED lamps 14 watts 230 volts PF>0.9, CRI>80 beam angle>120 degree complete all as specified and directed. Make: Jaquar /Philips/Wipro.
Note for Ser No 53 to 57 above: (i) Every fitting will be marked/ printed with "CA No" & "GE(North) Tezpur' (ii) 02 Years manfuctures warranty shall be submitted by the contractor.
Supply only switch piano type 5/6 amps 230 volts complete all as specified and directed.
Supply only switch socket 5 pin 5/6 amps 230 volts complete all as specified and directed.
Supply only switch socket 5 pin 5amps & 15 amps multi 230 volts complete all as specified and directed.
Supply only fan capacitor, AC 230 V, 2.5 MFD complete all as specified and directed.
Supply only fan capacitor, AC 230 V, 3.15 MFD complete all as specified and directed.
Supply only tap insulation 25mm 20mtr in red/yellow/blue colour suitable for working voltage of 440 volts.
Supply only tap insulation 25mm 20mtr in black colour suitable for working voltage of 440 volts complete all as specified and directed.
Supply only twin twisted flexible cable, PVC insulated with stranded copper conductor of size 24/0.0076, AC 1100 volts grade complete all as specified and directed.
Supply only 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed for service connections twin core of size 10 Sqmm complete all as specified and directed.
Supply only MCB single pole 10 amps, C series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB .
Supply only MCB single pole 16 amps, C series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB .
Supply only MCB single pole 20 amps, C series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB .
Supply only MCB single pole 32 amps, C series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB
Supply only MCB single pole & neutral 240 volts 32 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.
Supply only MCB single pole & neutral 240 volts 40 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.
Supply only MCB single pole & neutral 240 volts 63 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.
Supply only MCB TPN 240 volts 40 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.
Supply only MCB TPN 240 volts 63 Amps, 10 KA , C Series complete all as specified and directed. Note:- MCB Rating shall be suitable to the existing DB.
S&F in repair air termination,single pointed, copper rod 12mm dia and 300mm long including joiting materials such as nuts,bolts and washers of suitable size complete all as specified and directed.
M&L in repair for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm dia galvanised iron strip including jointing materials as required complete all as specified and directed.
M&L for earthing with galvanised iron earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre below ground level) with top edge of the earth plate not less than 1.5 metre below ground level surrounded from all sides 15 mm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using earth lead GI wire 4mm dia(8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to common earth dolly and protected by galvanised iron light grade pipe 15 mm bore in wall/floor and including 20 mm galvanised pipe for watering with funnel and wire mesh all as specified or indicated including excavation and connected earth work, in soft/loose soil, PCC 1:3:6 type C1 using 20mm graded stone aggregate as in pit and RCC 1:2:4 type B1 cover for earth pit cover reinforced with 8 mm dia TMT Bars @ 75mm C/C both ways and with handle made out of 08mm dia bars, GI funnel, strainer, including alternate layer of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part I and testing on completion , complete all as specified and directed.
Flint India
PURBANCHAL BUILDERS
SRI JAINATH SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .