Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
19 Jul 2021, 6:00 pmClosed
GE (North) Tezpur
GE (North) Tepur Solmara Cantt Tezpur (Assam) PIN -784501
Prvon of medium high mast light at 189 Fd Wksp under GE (North) Tezpur
2021_MES_457481_1
3036/Job Qtn/ 04 /E3 of 2021-22
Limited
Miscellaneous Services
Item Rate
90 days
GE (North) Tezpur
Please refer Tender documents
4 documents required · 4 mandatory
₹0
Exempted
21 Jul 2021
6 Jul 2021
21 Jul 2021
6 Jul 2021
19 Jul 2021
6 Jul 2021
6 Jul 2021 - 19 Jul 2021
(a) Materials and Labour for steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws as specified of type 410 SP 55(Overall length 11.00 meter). Pole shall be painted with two coats of black bituminous paint throughout internally and externally upto planting depth and from ground level upto 1.5m with synthetic enamel paint (painting in black & white alternate strips of 30cm each ) remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer complete. Erected in truly vertical position, grouted to a depth of 1.5 Mtr below ground level including necessary excavation and earth work, PCC (1:4:8) type D-2 in base (60 x 60 x 10 cm) and foundation (50 x 50 x 140 cm) and coping (60 x 60 x 30 cm) with (1:3:6) type C-1 including form work up to 30 cms above ground level , disposal of surplus soil to a distance not exceeding 50 mtr complete incl numbering of poles all as specified and directed.-02 Nos. (b) Supply and Fixing energy saving,envoirmental friendly long life LED flood light, made of pressure die-cast housing with toughned glass and induvidual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 with driver etc, and suitable for 150W LED all as specified and directed.Make- Havell's/Bajaj/Philips- 12 Nos. (c ) Supply and laying of LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core. 280 Rm. (d) Excavation in trenches, in soft / loose soil not exceeding 1.5m wide and not exceeding 1.5m in depth loose soil and getting out for laying of cable complete all as specified and directed.-55 CUM. (e) Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.-28 CUM. (f) Removing excavated materials (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.-26 CUM (g) Material and labour for sand cushioning for cable protection using clean dry sand complete all as specified and directed.-15 CUM (h) Supply and laying in trenches brick common burnt clay building brick, sub class 'B' designated- 75 with width equal to length of brick for cable protection complete - 1.0 Thousand (j) Supply and fixing of MS Angle/chanel made to shape, bend hot/cold including necesary clamps ,nuts,bolts& washrs ,suitable for fixing of flood lights-06 Nos,including necessary welding or fabrication work all as specified and direted. -0.50 Qtl (k) Supply and fixing junction box made out of thermo plastic, weather & vermin proof including provn of terminals and having provison of cable entry with cable glands including fixing arrangements i.e. MS clamps, nuts, bolts etc .Size of box - 155 x 210 x 92 mm. Make Hansel Cat No K- 9255 or eqvt. including one Nunbers MCB SP 10Amp 240 Volts .-02 Nos (l) M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground ( earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Metre below normal ground level connected to GI wire 4 mm dia by means of bolts, nuts , check nuts and washers of GI and GI tubing 15 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as shown on electrical plate No. 3 of SSR part - I complete alll as specified and directed.-02 Nos.
M/S B S TRADERS
MAX Graphics
stage.html
html • 0.02 MB
finance_509893.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .