Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Being lowest tenderer |
| 2 | L2₹1.8 Cr+₹29.3 L (19.5%)Rejected-Finance | ₹1.8 Cr+₹29.3 L (19.5%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.8 Cr+₹29.7 L (19.7%)Rejected-Finance PLOT NO 44 SIDDARTH PARK BEHIND ICE FACTORY KODKI ROAD BHUJ PIN 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | ₹1.8 Cr+₹29.7 L (19.7%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹2.1 Cr+₹56.3 L (37.4%)Rejected-Finance | ₹2.1 Cr+₹56.3 L (37.4%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹2.1 Cr+₹61.0 L (40.6%)Rejected-Finance | ₹2.1 Cr+₹61.0 L (40.6%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹1.9 Cr
EMD Value
₹2.7 L
Closing Date
28 Oct 2020, 6:00 pmClosed
CE (AF) GANDHINAGAR
LEKAVADA PATIA CHILODA GANDHINAGAR 382042
PROVISON OF ALL WEATHER GROUND RUN POINT AND MISC STORES/SHEDS AT CERTAIN LOC IN TECH AREA AT AF STN BHUJ
2020_MES_370451_1
87192
Open Tender
Civil Works
Lump-sum
730 days
GE (AF) BHUJ
As per NIT and Tender documents
10 documents required · 10 mandatory
₹1,000
GE (AF) BHUJ
₹2.7 L
Yes
11 Nov 2020
19 Aug 2020
29 Oct 2020
19 Aug 2020
28 Oct 2020
14 Oct 2020
26 Aug 2020 - 2 Sept 2020
Amount
NOTE: Schedule ‘A’ Part IA, II to VII are under Ser No. 1.00 to 7.00 are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Lump sum price worked out for BUILDINGS / STRUCTURES as listed in Sch 'A’ Part IA.
Lump sum price worked out for EXCAVATION & EARTH WORK as listed in Sch 'A’ Part II
Lump sum price worked out for INTERNAL ELECTRIFICATION INCLUDING WIRING FOR AC, (HIGH BAY LIGHTS) as listed in Sch 'A’ Part III
Lump sum price worked out for LIGHTENING PROTECTION as listed in Sch 'A’ Part IV
Lump sum price worked out for EXTERNAL ELECTRIFICATION as listed in Sch 'A’ Part V
Lump sum price worked out for ROAD/PATH as listed in Sch 'A’ Part VI
Lump sum price worked out for MOURING RING as listed in Sch 'A’ Part VII
SCHEDULE `A' PART - IB (TO BE QUOTED BY THE CONTRACTOR)
Lump sum price worked out for (PEB) PRE ENGINEERED BUILDING (WEATHER SHELTER) AND TESTER ROOM as listed in Sch 'A’ Part IB.(To be quoted by tenderer)
8. SCHEDULE 'A' PART-VIII MISCELLANEOUS ITEMS OF WORK (Note for items 8.01 to 8.29. The contractor shall quote his rate for each of these items separately. The estimated rate is left blank since the same is not prepriced by MES).
INTRENAL ELECTRIFICATION
Supply and fix LED Flame proof-weather proof highbay light fitting of 150 W (Minimum wattage or above) with proper clamp, Powder coated Aluminium housing fixtures, Powder coated control gear unit made of pressure die-cast aluminium, LED fixed to MCPCB on aluminium housing for proper thermal management, Constant current LED driver provided with surge protection of 4 KV, Fixture Input voltage range : 120-277 V AC, completely prewired with accessories, Eye-bolt provided for suspension mounting, fixture having IP65 protection and duly certified by CIMFR Dhanbad all as specified and directed by Engineer-in-Charge.
M&L for Submain wiring with 02 runs of 6 Sqmm and one run of 6 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-694) drawn through and including 25 mm ERW conduit grade ISI marked including accessories such as bendes, supports etc all as specified. Note : 2 runs of main cable and one run of earth cable and one run of conduit/casing caping shall be measured as one unit.
M&L for Submain wiring with 02 runs of 2.5 Sqmm and one run of 2.5 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-694) drawn through and including 25 mm ERW conduit grade ISI marked including accessories such as bendes, supports etc all as specified. Note : 2 runs of main cable and one run of earth cable and one run of conduit/casing caping shall be measured as one unit.
M&L for Submain wiring with 03 runs of 06 Sqmm and 02 run of 06 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLSH grade copper conductor cable signle core multistranded ISI marked (IS-694) drawn through and including 25 mm ERW conduit grade ISI marked including accessories such as bendes, supports etc all as specified. Note : 3 runs of main cable and 2 run of earth cable and one run of conduit/casing caping shall be measured as one unit.
Supply and fix FLP WP 4 WAY TPN, IP 65, factory made distribution box in cast aluminium alloy LM6 construction with suitable terminals & cable glands, light grey epoxy powder coated, SS hardware certified by CIMFR, Dhanbad for Gas Gp-I, IIA & IIB as per IS/IEC-60079 1:2007 consisting of following :- Incoming 1 Nos 63 Amps TPN MCB Outgoing : 3 Nos 32 Amps SPN & 6 Nos 16 Amps MCB SP
Supply and fix Flamproof Light WP12 way SPN factory made distribution box in LM6 construction with suitable terminals and glands, ligth grey epoxy powder coated, SS hardware cerfified by CIMFR Dhanbad for gas grade-IIA & IIB as per IS/IEC-60079 consisting following :- (a) Incoming : 63 Amp MCB 01 Nos. (b) Outgoing : 6-20 Amps MCB SP 10 Nos
Supply and fix Flamproof Light WP08 way SPN factory made distribution box in LM6 construction with suitable terminals and glands, ligth grey epoxy powder coated, SS hardware cerfified by CIMFR Dhanbad for gas grade-IIA & IIB as per IS/IEC-60079 consisting following :- (a) Incoming : 40 to 63 Amps MCB 01 Nos. (b) Outgoing : 6-20 Amps MCB SP 06 Nos
Supply and fix Flamproof Light WP04 way SPN factory made distribution box in LM6 construction with suitable terminals and glands, ligth grey epoxy powder coated, SS hardware cerfified by CIMFR Dhanbad for gas grade-IIA & IIB as per IS/IEC-60079 consisting following :- (a) Incoming : 40 to 63 Amps MCB 01 Nos. (b) Outgoing : 6-20 Amps MCB SP 02 Nos
Supply and fix FLP WP Rotary switch 16A, IP 65, three phase ON-OFF with cable termination box in LM6 complete all as specified and directed.
Supply and fix FLP WP Rotary switch 25A, IP 65, single pole ON-OFF with cable termination box in LM6 complete all as specified and directed.
M&L for flame proof and weather proof (Protection Class IP-65) enclosure suitable for LED tube light fitting including lamp (tube), 2 x 22 watt, aluminium cast alloy LM-6, inside and outside light grey epoxy coating, prewired complete with electronic ballasts, capacitors, spring loaded rotor type lamp holder, starter, starter holder and connector block etc all accessories fixed on two numbers of wooden block on wall or on ceiling and connecting up complete with 23/0.0076 flexible three core copper cable in flexible steel conduict with flame proof cable glands all as specified and directed.
Supply and fix flame proof switch socket 25A, 500V, 3P+Earth, with operating switch cast aluminium body LM6 alongwith all as per Engineer-in-Charge.
Supply and fix flame proof switch socket 16A, 250V, 2P+Earth, with operating switch cast aluminium body LM6 alongwith all as per Engineer-in-Charge.
Supply, install and commissioning hi wall 1.5 TR Split AC units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 complete all as specified and as directed.
M&L for Submain wiring with 02 runs of 4 Sqmm and one run of 4 Sqmm as earth continuity, 1100 V grade PVC insulated, unsheathed FRLS grade copper conductor cable signle core multistranded ISI marked (IS-694) drawn through and including 25 mm ERW conduit heavy grade ISI marked including accessories such as bendes, supports etc all as specified. Note : 2 runs of main cable and one run of earth cable and one run of conduit/casing caping shall be measured as one unit.
EXTERNAL ELECTRIFICATION
Supplying and laying un-reinforced precast concrete cable cover, class LV type 2, flat of size 300mm x 180mm x 40mm with engraved text "LT CABLE" complete all as specified and as directed.
Supply laying & testing of XLPE, insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cable (heavyduty) with aluminium conductor, 1100 volts, Earthed grade of size 3.5 core 50 Sqmm complete all as specified and as directed.
Supply laying & testing of XLPE, insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cable (heavyduty) with aluminium conductor, 1100 volts, Earthed grade of size 4 core 10 Sqmm complete all as specified and as directed.
Supply laying & testing of XLPE, insulated, screened, PVC bedded, galvanised steel strip armoured, electric power cable (heavyduty) with aluminium conductor, 1100 volts, Earthed grade of size 2 core 6 Sqmm complete all as specified and as directed.
Supply and fix LED flood light 70W pressure die-cast aluminium housing, complete with all accessories IP 65 including nut/bolt clamps including connection from MCB to LED light with one run of 1.5 Sqmm three core multistranded copper conductor FRLS PVC insulated and unsheathed cable 1100 volts grade ISI marked wire all as directed by Engineer-in-Charge.
ROAD/PATH
M&L for 150mm thick (Compacted thickness) approved Granular Sub Base (GSB) type I over compacted sub grade by crushed stone for newly construction of rigid pavement in layer not exc 100mm thick single, including spreading, levelling, watering and rolling with 8 to 10 ton roller to gradient and camber as per MORTH specification complete all as specified. Note :- Area of 150mm thick layer shall be measured for payment purpose.
M&L for 150mm thick (compacted thickness) WMM (Wet Mix Macadam) with coarse aggregate of granite, trap or basalt stone, spread with mechanical paver, rolled and consolidated to required gradient and camber all as specified and as directed. Note :- The compacted thickness 150mm shall be achieved by laying material in two equal layers and rolled each layer seperately.
M&L for 150 mm (compacted thickness) DLC (Dry Lean Concrete) using minimum 240 Kg/Cum of cement and 7 days compressive strength M-15 (design mix) using crushed stone aggregate all as specified and as directed.
M&L for providing 400 micron thick HDPE sheet with end lap and side lap 100mm minimum complete all as specified and as directed. Note :- Net Plan area of sheet in contact with PQC (without allowance of lap) shall be measured for payment purpose.
M&L for 320 mm thick pavement quality concrete (PQC) of flexural strength 44 Kg/Sqcm in field using minimum 400 kg of cement per cubic metre of concrete laying in bays as specified in drgs including necessary steel form work and using non circular synthetic triangula recron fibre @ 0.25% by weight of cement, duly broom finished complete all as specified and as directed.. Note - Non circular recron fibre shall be measured and paid seperately.
M&L for forming expansion joint 25mm thick filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound grade 'A' for thickness of concrete 320 mm.
M&L for forming construction joint 30mm deep and 10mm wide filled with sealing compound grade 'A'.
M&L for forming contraction (dummy) joint 110mm deep and 8mm wide filled with sealing compound grade 'A'.
M/s Pal Builders
M/S S. SINGH TRADERS
M/s Vijay Kumar Garg
GARGA ASSOCIATES
Singla Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .