Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹49.8 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 1 | Accepted-AOC AOC | |
| 2 | 2₹50.8 L+₹52,282 (1.04%)Rejected-AOC | 2 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
14 Sept 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
GE ARMY BHUJ
SPL REPAIR TO BLDG NO P-44 01 TO 08 T 285 AT MIL STN BHUJ UNDER GE(A) BHUJ
2023_MES_613399_1
8148
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE ARMY BHUJ
₹93,000
Yes
8 Oct 2023
12 Aug 2023
16 Sept 2023
12 Aug 2023
14 Sept 2023
28 Aug 2023
Amount
Demolition of cement concrete (unreinforced) in ground floor and paving n.exc 15cm in thickness (below or above ground level) all as specified.
Demolition of reinforced cement concrete of any description and in any position not otherwise specificlly provided for (reinforcement cut as required to facilitate demolition) all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles all as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises all as directed.
Taking down cement plaster on brick / stone walls including raking out joints, hacking for key, scrubbing down with water all as directed
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
M&L for glazed ceramic coloured tiles of size 450 x 300 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas; all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
S&F mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip all as specified & directed by Engineer-in-Charge.
S&F mild steel TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mmdia or securing with clip all as specified & directed by Engineer-in-Charge.
M&L for rendering, 15 mm thick on brick work or concrete surfaces in cement mortar 1:6 on wall finished even and smooth without using extra cement all as sepecified and directed.
M&L for rendering, 10 mm thick on brick work or concrete surfaces in cement mortar 1:4 on ceiling finished even and fair all as sepecified and directed.
Preparation of old decorated plastered or unplastered surfacesof wall including washing , rubbing down and stopping of distempered surface M&L for applying one coat of distemper oil emulsion paint white or tinted complete all as specified
M&L for 3 coats of white wash on newly / old plastered surfaces incl preparation etc. complete on ceiling.
Preparation of New/ old decorated surfaces of comougflage wall pattern including cornices plastered or unplastered surfaces by brooming down or steel wire brushing to remove dust, dirt and loose scales of cement paint and other foreign material, scrapping down, moss and efflorescent salts, washing, rubbing down and stopping of painted surface and M&L for applying Two coats of cement base paint incl watering and curring of surfaces adequately before and after application of cement base paint compelete all as specified and directed.
M&L for broken brick boulder hard core of gauge, deposited, spread and levelled in layers n exc 15 cm thick, watered and rammed to a true surface.
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
M&L preparation of new steel surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over a coat of red oxide primer all as specified.
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 and finished fair and even including mixing of WPC in mortar complete all as directed by Engr-in-charge.
Supply only integrated water proofing compound complete all as directed by Engr-in-charge. Make:- Dr Fixit/Fosroc/BASF/STP
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame)
Taking down shutters of any description exc 1 Sqm and n.exc 2 Sqm each all as sepcified and directed.
S&F framed work as in chowkats of doors windows of angle iron ,gates or other section with gusset plates, rails, braces etc conforming to Gde Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-Charge.
S&F hold fast of flat iron 25 x 3 mm conforming to Fe-290 or Fe 330 including preparing the surfaces & treated with two coats for coaltar & sanded with clean sharp sand complete all as specified & directed
M&L for Cement concrete 1:3:6 type C–1 (using 20mm graded crushed stone aggregate) as in coping, hold fast, bed blocks or similar block etc complete all as specified and directed by Engineer - in - Charge.
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required built in colour in three legged of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood in all three legs frame shall be covered with fibreglass from all sides MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled doorshutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge.
S&F 100 mm long butt hinge, extruded aluminium alloy with galvanised mild steel hinge pin, anosied and fixed type B-21 all as specified and directed.
S&F 200 mm long aluminium anodised barrel tower bolt, of extruded sections all as directed.
S&F 150 mm long aluminium anodised handle, cast type all as directed.
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each all as specified and directed. (Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
S&F 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated all as directed.
S&F 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) all as directed.
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel all as specified and directed.
S&F 300 mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate all as directed.
S&F as 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed by Engr-in-Charge.
S&F 125 mm long aluminium anodised handle, cast type all as directed.
S&F stainless steel wire cloth 0.63 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples all as directed.
All as per item No 40 above but fixed in repairs.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in squares n. exc. 0.5 Sqm in each pane complete all as specified & directed by Engineer-in- charge.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as directed.
M&L preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified.
M&L preparation of old painted wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint all as specified.
S&F drapery rods, coloured, standrad quality, SS Finish not less than 25mm dia with heads at both ends and middle support, rings, etc.complete all as specified and directed by Engineer - in Charge.
S&F in repair towel rails 20mm dia 600mm long brass chromium plated superior quality brass chromium plated fancy type complete all as specified.
S&F in repairs vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests (excl flushing cistern) but including CI 'P' trap set in and including concrete fixed.
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe and connection to pipe and flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern all as directed.
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, long screwed shank fly nut flange end including cutting for and pinning in ends of brackets in 1:3 CM including 32mm dia chromium plated waste coupling/trap all as specified .
S&F pillar tap, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed. Wt not less than 450 gms
S&F in repair bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, hand operated, screwed for iron pipe or for brass ferrule all as specified.
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed all as specified.
S&F in repair CP brass stop valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed all as specified. Make : Jaquar cat No- 7053 or equivalent in Marc/Plumber.
S&F in repair, shower rose, 125 mm size, brass chromium plated with sweivel joint all as directed.
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm all as directed.
Dismentling of water tanks of capacity exc 500 and n.exc 1000 ltrs and removing from site all as specified and directed.
S&F rotational moulded polythene water storage tank 1000 ltr capacity of tripple layer vertical with closed top hoisted and fixed in position all as specified in SSR part-I. All as directed.
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore fixed in repair all as specified and as approved by GE/Engineer-in-Charge.
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe all as specified and directed.
Taking down 15 mm dia steel GI tubing including all connected fittings of any dia and in any position including cleaning for re fixing the serviceable pipe all as directed.
All as per item No 63 above but 20mm dia pipe.
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as directed.
All as per item No 65 above but 15mm dia pipe fixing only.
All as per item No 65 above but 20mm dia pipe.
All as per item No 65 above but 20mm dia pipe fixing only.
Supporting: Supporting the structural element temporarily using heavy duty flat headed steel ropes vertically in plumb, braced horizontally and diagonally at centre with each other using 40NB heavy steel pipes and supporting a continuous 4"x 3" wooden runner just below the structural elements, resting on wooden block to support the structure provisionally during repairs and maintaining them in position till required complete all as specified and as directed by Engr-in-charge. (Note : Mode of measurement per prop per repetition). NOTE : To be done only where the structure is in danger of falling as assessed by the GE.
Carefully chipping, removing existing loose/ damaged concrete with plaster by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower complete as specified and as directed by Engr-in-charge.
Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, all as specified and directed. (Mode of measurement: per sqm of breaking area of concrete.) Make: SG Corporation- Eget ARUP/ Pratham Enterprises- Impermo 1002/ Optimus Chemicals- Optychem PAR or equivalent
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min 0.4 kg/Sqm approx) as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) Make: SG Corporation- Eget ACORB/Pratham Enterprises- Impermo 1003/ Optymus Chemicals- Optychem BOR or equivalent..
Additional rebars 10mm dia and above Providing and fixing additional corrosion resistant hot dip galvanised steel rebar Fe 415 or high grade as per required diameter in various structural elements to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and directed.
Shear key connectors: Drilling holes in concrete of suitable diameter, providing and fixing 8 mm diameter High Yield Steel reinforcing bars at on the RCC surface at 350 mm c/c or as per site requirement. Shear keys shall be 75mm long with embedment length of 40mm and projecting out of the concrete surface with a horizontal bend of about 25mm all as specified and as directed.
Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Beams and Lintels. Make: SG Corporation- Catena SB/ Pratham Enterprises- Impermo 2001/ Optimus Chemicals- Optybond SOV or equivalent.
Rebuilding the section of structural damaged RCC/PCC elements of Beams and Lintels repair to spalling concrete to its original size and shape in layers of 20 mm each by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79. Make: SG Corporation- Verdhaio PMM/ Pratham Enterprises- Impermo 4006/ Optimus Chemicals- OptyRE P40 or equivalent.
10 mm average thickness in 1st layer
Add for each addl 10mm uniform thickness for subsequent layers.
Plaster: Providing and Applying Cement plaster: ready to mix cement plaster with high quality polymer additives with 4 Mpa compressive strength of average 15 mm thick over the entire surfaces including all tools and tackles etc complete.
Providing and applying white-wash in one coat on plastered or masonry surfaces and including preparing the surface by brushing and brooming down etc. complete.
Excavation: Excavation around footings of columns in earth, soils of all types, sand, gravel, soft murum including shoring and strutting, dewatering as necessary and disposing off or stacking excavated stuff as directed etc. complete
Re filling of excavation: Providing and filling good and approved earth, including watering, levelling, laying stone soling over fully compacted subbase, filling voids/interstices with smaller size stones, binding layer of sand and stone grit, including compaction, etc. as per site conditions etc. complete.
PCC: 100mm thick Plain Cement Concrete 1:2:4 type B-1(using 20mm graded stone aggregate) surface finished to receive finishing coat of metalic hardner complete all as specified and as directed.
Demolition of masonry: Demolition of brick masonary including stacking of serviceable materials and disposal of unserviceable materials with all lead and lift at specified location, etc. complete.
Reconstrcution of masonry: Providing and laying brick masonry in cement mortar 1:4 (1 cement : 4 coarse sand ) including placing 2 Nos of 6mm dia. bars at every 1m height of masonry work, raking of joints, curing, etc. completed as directed by Engineer-in-Charge.
Carefully chipping, removing existing loose/ damaged concrete with plaster by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower complete as specified and as directed by Engr-in-charge.
Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, all as specified and directed. (Mode of measurement: per sqm of breaking area of concrete.) Make:SG Corporation- Eget ARUP/ Pratham Enterprises- Impermo 1002/ Optimus Chemicals- Optychem PAR or equivalent.
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min 0.4 kg/Sqm approx) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) Make: SG Corporation- Eget ACORB/Pratham Enterprises- Impermo 1003/ Optymus Chemicals- Optychem BOR or equivalent.
Additional rebars 10mm dia and above Providing and fixing additional corrosion resistant hot dip galvanised steel rebar Fe 415 or high grade as per required diameter in various structural elements to replace the lost rebar section due to corrosion including cutting, bending and fixing the bar by installing new rebar with Epoxy Acrylate based anchoring adhesive complete all as specified and directed.
Shear key connectors: Drilling holes in concrete of suitable diameter, providing and fixing 8 mm diameter High Yield Steel reinforcing bars at on the RCC surface at 350 mm c/c or as per site requirement. Shear keys shall be 75mm long with embedment length of 40mm and projecting out of the concrete surface with a horizontal bend of about 25mm all as specified and as directed.
Fixing of nozzles: Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 350 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
Epoxy grouting: Grouting, injecting two part, low viscosity, moisture insensitive injectionliquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost. (Mode of measurement: per kg of material consumed) Make: SG Corporation- Verdhaio LVG/ Pratham Enterprises- Impermo 4002/ Optimus Chemicals- OptyRE POLYG or equivalent
Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Beams and Lintels. Make: SG Corporation- Catena SB/ Pratham Enterprises- Impermo 2001/ Optimus Chemicals- Optybond SOV or equivalent
RebuildingthesectionofstructuraldamagedRCC/PCCelementsofBeamsandLintelsrepairtospallingconcretetoitsoriginalsizeandshapeinlayersof20mmeachbyprovidingandapplyingwithpre-batched,onecomponentfiberbasedrepairmortarhavingcompressivestrength>=50N/sqmm(28days)accordingtoASTMC109;flexuralstrength>=5N/sqmm(7days)accordingtoASTMC293-79.Make:SGCorporation-VerdhaioPMM/PrathamEnterprises-Impermo4006/Optimus Chemicals- OptyRE P40 or equivalent.
(a) 10 mm average thickness in 1st layer
(b) Add for each addl 10mm uniform thickness for subsequent layers
Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacture specification including cleaning of surface to remove all dirt, dust or any other impurities, etc. complete as specified and directed. The product should comply with ASTM C 881 Type II Grade 2 Class B+C and bond strength should be 10 MPa. Make: SG Corporation- Catena EB/ Pratham Enterprises- Impermo 2004/ Optimus Chemicals- Optybond EOB or equivalent.
Rebuilding the section of damaged RCC elements to its original size in thickness upto 100mm by providing and casting with ready to use non shrink, cementitious free flow micro-concrete having compressive strength > 60 N/sqmm (28 days) according to ASTM C 1107-99 including mixing, placing, leveling the surface by grinding off cementitious slurry or cementitious joints differences if any and curing complete all as specified and directed. Make: SG Corporation- Verdhaio MC/ Pratham Enterprises- Impermo 4004/ Optimus Chemicals- OptyRE M60 or equivalent.
Formwork and shuttering: Providing watertight form work of ordinary timber plankings so as to give a rough finish including centering, shuttering, struting and propping et., all as specified and as directed.
Providing and applying white-wash in one coat on plastered or masonry surfaces and including preparing the surface by brushing and brooming down etc. complete.
Carefully chipping, removing existing loose/ damaged concrete with plaster by low impact high frequency hammer/ chipper without damaging the existing sound concrete and exposing old reinforcement upto 10mm beyond corroded reinforcement bars using electrically operated diamond concrete saw blade making the edges straight and even and cleaning it by wire brush and then by air blower complete as specified and as directed by Engr-in-charge.
Cleaning all existing reinforcement bars with wire brush/rotary wire brush to make entire circumference surface of bars free from rust scales, loose material, dirt etc., complete and applying alkaline rust converting primer on the existing rebar and allowing it to react with rust for 6 hrs and form a corrosion resistant, insoluble and adherent protective layer including cleaning the reinforcement, wire brushing to remove the rust spalls, complete as per manufacturers instructions, all as specified and directed. (Mode of measurement: per sqm of breaking area of concrete.) Make:SG Corporation- Eget ARUP/ Pratham Enterprises- Impermo 1002/ Optimus Chemicals- Optychem PAR or equivalent.
Providing and application of Zinc rich epoxy anti-corrosive protective coating for reinforcement bars as corrosion protection system in 2 coats to the entire circumference surface of bars (consumption Qty as per manufacturers instructions but min 0.4 kg/Sqm approx) in Roof, Ceiling, Chajja, Fascia, Fins, Drops and similar items complete all as specified and directed by Engr-in-charge. The product should confirm carbonation resistance of 2 mm and bond strength > 1N/sqmm according to ASTM C 882-78 (Mode of measurement: per sqm of application area of concrete.) Make: SG Corporation- Eget ACORB/Pratham Enterprises- Impermo 1003/ Optymus Chemicals- Optychem BOR or equivalent.
Fixing of nozzles: Drilling Holes of 12mm dia up to 100 mm deep holes in structural members at the interval of 350 mm in staggered manner or along the crack line in Reinforced Concrete (RC) structural element including cleaning of the holes by air blower and inserting 12mm dia NRV (Non Returnable Valve) nozzle compatible with epoxy injector and having machined external end to receive outlet of Grouting Gun. Fix inside the hole by applying thixotropic epoxy adhesive to ensure complete sealing and allow curing the system for minimum of 8 Hrs before Grouting including nozzle projections, excess putty, if any, over concrete element by grinding, leveling and finishing the external surface, after completion of the work, etc. complete all as specified and directed.
Epoxy grouting: Grouting, injecting two part, low viscosity, moisture insensitive injectionliquid, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout having following properties:- (i) Mixed Density 1.1 kg/l (at +27°C); Viscosity ~ 250 mPas at +30°C and should comply according to ASTM C 881, Type II and IV, Grade-1, Class E+F (ii) Compressive strength >= 70 N/sqmm (7 days) according to ASTM C 579; Tensile Strength ~ 50 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); Tensile Modulus ~ 2000 N/sqmm (after 7 days at +30°C cure) (According to ASTM D 638); (iii) Bond Strength ~ 10.8 N/sqmm (failure in concrete) after 14 days at +30°C cure; Flexural strength ~ 50 N/sqmm according to ISO 178. (iv) Seal the nozzle with thixotropic epoxy adhesive after the refusal of grout material from the nozzle. Note:- leakage through other nozzle or cracks are required to be monitored while grouting and such points to be sealed as and when required without any extra cost. (Mode of measurement: per kg of material consumed) Make: SG Corporation- Verdhaio LVG/ Pratham Enterprises- Impermo 4002/ Optimus Chemicals- OptyRE POLYG or equivalent.
Apply SBR based bonding agent to the entire concrete surface prior to building up of concrete with Polymer modified mortar or any other treatment , including cleaning the surface to remove dirt, dust or any other impurities on the surface, etc. complete in Beams and Lintels. Make: SG Corporation- Catena SB/ Pratham Enterprises- Impermo 2001/ Optimus Chemicals- Optybond SOV or equivalent.
Rebuilding the section of structural damaged RCC/PCC elements of Beams and Lintels repair to spalling concrete to its original size and shape in layers of 20 mm each by providing and applying with pre-batched, one component fiber based repair mortar having compressive strength >= 50 N/sqmm (28 days) according to ASTM C 109; flexural strength >= 5N/ sqmm (7 days) according to ASTM C 293-79. Make: SG Corporation- Verdhaio PMM/ Pratham Enterprises- Impermo 4006/ Optimus Chemicals- OptyRE P40 or equivalent
10 mm average thickness in 1st layer
Add for each addl 10mm uniform thickness for subsequent layers
Fiber wrapping: Design, fabrication and supply of FRP system for strengthening of structural elements comprising of FRP sheet and compatible saturant, by dry/wet layup system including, Surface preparation: Grinding, moulding concrete substrate. Cleaning it with wire brush, removing oil, laitance if present. Rounding off sharp edges to minimum 25 mm radius. Profiling: Applying epoxy primer on prepared substrate, filling holes and uneven surfaces with thixotropic putty, etc. complete. Wrapping: Wrapping the fibre sheet to structural element at desired orientation with application of compatible epoxy saturant using tamping roller to avoid any air voids. Sand pasting: Applying second coat of saturant, rectify air voids if any; paste the river sand on it to make surface rough to take further finishes. (Mode of measurement: Fiber area of application, not surface area of RCC member.) Make: GFRP: SG Corporation - Verdhaio GWRP 900/ Pratham Enterprises - Impermo 4014/ Optimus Chemicals - OptyRE GRHD9 or equivalent. Epoxy Primer: SG Corporation - Verdhaio Prime/ Pratham Enterprises -Impermo 4007/ Optimus Chemicals - OptyRE PME or equivalent. Epoxy Saturant: SG Corporation - Verdhaio Saturant/ Pratham Enterprises - Impermo 4008/ Optimus Chemicals - OptyRE STT or equivalent.
Plaster: Providing and Applying Cement plaster: ready to mix cement plaster with high quality polymer additives with 4 Mpa compressive strength of average 15 mm thick over the entire surfaces including all tools and tackles etc complete.
Providing and applying white-wash in one coat on plastered or masonry surfaces and including preparing the surface by brushing and brooming down etc. complete.
M&L in repair for preparing the existing surface by cleaning thoroughly to make it smooth and free from any foreign matter such as fungus, moss, dust etc by wire brushing and dusting followed by 10mm thick rendring in CM 1:4 including water proofing compound and applying a coat of bitumenous primer conforming to IS : 3384 - 1986 @ 0.30 litre / Sqm and then pressing & laying 3mm thick Atactic Polypropylene Polymer (APP) modified prefabricated with non woven polyester reinforcement five layer water proofing membrane weighing not less than 3.50 Kg/ Sqm comprising of centre core of 160 - 170gsm non - woven polyster matt sandwitched on both sides by APP polymer modified bitumen duly protected on both sides by 20 micron HMHDPE film by torch on application with gas welding torch (Butane torch), and thereover applying a tack coat of 85/25 blown grade bitumen conforming to IS : 702 @ 1.20 Kg / Sqm and finish the top surfaces with aluminium paint (Super Silver Shield) @ 0.150 Ltr / Sqm complete all as specified. as per manufacturer's instructions and as directed. Note :- 1. The WPT work shall be got done through manufacturer's authorised applicator only under strict supervision of manufacturer's technical representative. 2. Water proffing compound measured and paid separately.
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) internal dia of pipe in 75mm set in cement mortar
Demolition and breaking up drain pipes (salt glazed ware, AC or Reinforced concrete) internal dia of pipe in 110mm set in cement mortar and taking out of trenches, if required
S&F for 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F for 110mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 75mm dia PVC (SWR) bends any radius with access door.
S&F 110mm dia PVC (SWR) bends any radius with access door.
Supply & fix rolled mild steel in joist, angle ,channel as in purlins, rafters cleats etc conforming to Fe-410- W (Gde-E-250)quality A, all as directed.
S&F mild steel rolled section as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe 290 GdeE-165 complete all as specified
Dismantling asbestos cement (corrugated or semi corrugate, etc.,) sheets in roof covering complete all as specified
S&F prepainted galvaluam aluminium zinc coating GI base corrugated steel sheet 0.60mm thick of colour as directed by GE having tensile strength of 550MPa as in roof covring/cladding to wall, with necessary rubber/PVC end cappings/closure at support fixed with self tapping screws complete all as spd and directed (Note: Corrugation shape and colour of sheet shall be approved by GE)
S&F prepainted galvaluam aluminium zinc coating GI base plain sheeting steel sheet 0.60mm thick of colour as directed by GE for ridge having tensile strength of 550MPa as as in roof covring/clading to wall, with necessary rubber/PVC end cappings/closure at support fixed with self tapping screws fixed with self tapping screws complete all as spd and directed (Note: Corrugation shape and colour of sheet shall be approved by GE)
S & F for hand rails, half round or other stock section, drilled to wind ties for roof including securing bolts etc, including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.
M&L for preparation of new steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified.
M&L for Pre-cast cement concrete block masonry (Type C1, 1:3:6, 20mm aggregate) with solid blocks, exc. 10cm in width and setting in mortar, complete all as specified and directed.
Demolition of concrete block masonry built in cement mortar or cement lime mortar
Taking down cement plaster of any description and in any position of brick/concrete surfaces on walls / celing etc. including racking out joints, hacking for key, scrubbing down with water etc & prepared to receive new plaster and disposing off the rubbish off the premises of cantonment complete all as specified and directed.
M&L rendering 15 mm thick in CM (1:4) on brick work or concrete surfaces finished the surfaces even and smooth without using extra cement with integral WPC complete all as specified. (Note:- Water proofing compound shall be measured and paid seperately under appropriate item of Sch 'A' as "supply only")
M&L for 10 mm thick rendering on surfaces other than fair faces of brick/concrete surfaces in CM (1:6) and finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparing newly plastered or unplastered surface of wall and applying three coats of white washing complete all as specified and directed.
Supply only water proofing compound (ISI Mark) complete all as specified and directed.
Dismantaling and taking down copper / aluminium point wiring any type / size complete with removing all connection and accessories such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed by Engr-in-charg.
M&L for Point wiring complete with FR PVC insulated unsheathed , 1100 V grade conforming to IS 694 , 1.5 Sqmm (Norminal area) multistranded ,copper conductor cable drawn through in non metallic rigid PVC conceled/surface conduit medium grade ,minimum 20 mm dia, ISI Marked, with sutaible size of 1 to 8 module metal flush boxes and back plate for mounting of modular switches/socket and regulators and including modular fornt plate with all acessories complete .
(a) One light point controlled by one way one switch SP 5 Amps ,240 V.
(b) One light point controlled by two 2 way switch SP 5 Amps ,240 V.
(c) One ceiling/exhaust fan point controlled by one way one switch SP 5 Amps, 240 V.
(d) One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
(e) One switch socket outlet 3 Pin, 5 Amps, SP on same board.
All as per the above item No 4 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet.
S&F switch piano flush type single pole one way 6 Amps 240V grade ISI marked.
S&F switch piano flush type single pole two way 240V grade ISI marked .
S&F socket outlet 2 in 1, 3 Pin , 6 Amps flush type ISI marked.
S&F socket outlet non inter locking type 3 pin ,16 Amps flush type ISI marked.
S&F switch piano flush type single pole one way 16 Amps 240V grade ISI marked.
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete
Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting upto PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square PVC bolck for fixing of FTL fitting complete all as per directed by Engr-in-charge.
Supply and fixing of mirror light of capacity 1x10 Watt epoxy white powder coated CRCA sheet steel housing with acrylic diffuser gaskat with all fixing acessories complete all as specified and directed.
supply & fixing of electronic type regulator of capacity 240 Volt flush type .
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 12 way, 240 Volts, sheet metal powder coated, IP 42 protection , double door type complete all as specified and directed.
S&F MCB SPN, 40 Amps, 240 Volts, rupturing capacity 10 KA."B" Series complete.
S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
supply and fix AC surge protection device, one pole & neutral, Voltage 240V DIN rail mounted,electrical conncetion with suitable rating copper wire complete all as specified and directed by Engr-in-charge.
supply and fixing under voltage & over voltage protection ,DIN rail mounted,single phase electrical conncetion with suitable rating copper wirecomplete all as specified and directed by Engr-in-charge.
Supply & fix RCBOs double pole 40A for earth leakage, overload & short- circuit protection 30 mA complete
M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
S&f angle holder backlite with 1x11 Watt LED Bulb with fixed on hylum sheet including all fixing acessories and making of connection with twin core flexible copper conductor from ceiling rose to fitting complete all as specified and directed.
Taking down celing fan /exhaust fan for refixing after painting , overhauling including greasing oiling etc complete.
Hanging only repaired celing fan /exhaust fan after painting , overhauling , greasing and replacement of U/S componante to make functional including provision of 3 core flexible copper conductor from ceiling rose to fan complete all as specified and directed .
Supply and lay pipe uPVC pipe including fittings of size 50 mm (2.0") dia complete all as specified and directed
Supply and lay pipe uPVC pipe including fittings of size 25 mm (1.0") dia complete all as specified and directed
M&L for cutting of existing DI/CI pipe line in position for rectifying leakage and reducing to required length, in position, for insertion of collars or other fittings including necessory exvation and earthwork, dewatering etc,if any involed, complete all as specified and directed for 50 / 100 mm bore of pipes
supply and fix ball valve 25 mm dia including all fittings all as specfied and directed
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
Dismantaling and taking down copper / aluminium point wiring any type / size complete with removing all connection and accessories such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed by Engr-in-charg.
M&L for point wiring with 1.5 Sqmm PVC insulated sheathed fire retardant (FR) cable with multithreaded copper conductor cable in and including heavy duty 20mm dia ISI marked concealed PVC conduit with all accessories for one light/fan point controlled by one switch with 1.25mm thick Metal boxes concealed in wall duly painted with one coat of primer and two coat of black bituminous paint ,sleek mounting plates for fixing switches regulator and including 1.5 Sqmm stranded copper conductor earth wire connected to common earth and dully complete all as specified.
(a) One light point controlled by one way one switch SP 5 Amps ,240 V.
(c) One ceiling/exhaust/Air circulator fan point controlled by one way one switch SP 5 Amps, 240 V.
(d) One switch socket outlet 3 Pin, 5 Amps, SP on independent board.
(e) One switch socket outlet 3 Pin, 5 Amps, SP on same board.
All as per the above item No 4 herein before but with 2.5 Sqmm cable for 3 Pin 5/15 Amps switch socket outlet.
S&F switch piano flush type single pole one way 6 Amps 240V grade ISI marked.
S&F socket outlet 2 in 1, 3 Pin , 6 Amps flush type ISI marked.
S&F socket outlet non inter locking type 3 pin ,16 Amps flush type ISI marked.
S&F switch piano flush type single pole one way 16 Amps 240V grade ISI marked.
S&F ceiling rose surface backlite 65 x 20mm size three terminal ISI marked complete
Supply and fixing LED lights fitting 1x 20 W, 220V,AC decorative box type with driver, holder including LED tube light connecting upto PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through in PVC flexible conduit including as per site requirement and 2 Nos of round or square PVC bolck for fixing of FTL fitting complete all as per directed by Engr-in-charge.
Supply and fixing LED flood lights fitting of capacity 100 Watt 230Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection , with impact and corrosion resistant complete with driver and lamp complete all as per directed by Engr-in-charge.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated, IP 42 protection , double door type complete all as specified and directed.
S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
S&F MCB SPN, 40 Amps, 240 Volts, rupturing capacity 10 KA."B" Series complete.
M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
S&F building security light of capacity 35 watt top openable , separate driver compartment , 10 KV surge protection external type , under voltage & high voltage protection , 100 lumen per watt or higher , 1 LED be 1 to 3 watt , pressure die cast aluminium body , moulded type driver , IP - 67 , including all fixing arregement complete.
Supply and fix in replacement XLPE insulated armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross sectional area 10 sqmm 2 core complete all as specified and directed
Excavation in trenches in soft/loose soil , not.exc 1.5 mtr wide and not.exc 1.5 mtr deep and getting out in soft/loose soil for laying of cable/foundation of pole and stay etc in complete as sepecified.
Returning filling including spreading, levelling, watering and well ramming in layers n.exc 25 cm.
Removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above ground level from starting point.
M&L for river sand cushioning in trenches for protection of LT under ground cable including watering and consolidation.
Supplying and laying un-reinforced precast concrete cable cover class LV Type 1, flat, size 250mm x 150mm x 40mmcomplete as sepecified.
Supply and laying GI tube light grade 40 mm bore complete as sepecified.
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
machine vision plus
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .