| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.6 LAdmitted-Finance NIGEEN HAZRATBAL SRINAGAR | ₹3.6 L | L1 | Admitted-Finance |
| 2 | L2₹3.8 L+₹21,000 (5.88%)Admitted-Finance 15 NEW IDDGAH BUILDINGS NH BARAMULLA BARAMULLA JAMMU KASHMIR 193101 | BARAMULLA | JAMMU AND KASHMIR | 193101 | ₹3.8 L+₹21,000 (5.88%) | L2 | Admitted-Finance |
| 3 | L3₹4.0 L+₹48,000 (13.4%)Admitted-Finance 37 LACHMAN PORA BATAMALOO SRINAGAR J K | ₹4.0 L+₹48,000 (13.4%) | L3 | Admitted-Finance |
| 4 | L4₹4.5 L+₹93,000 (26.1%)Admitted-Finance BAGH I ALI MARDAN KHAN NOWSHERA SRINAGAR J K 190011 | SRINAGAR | JAMMU AND KASHMIR | 190011 | ₹4.5 L+₹93,000 (26.1%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | BHAT CONSTRUCTIONS L1 | M/S P.M.T INDUSTRIES L4 | NSCOO ENGINEERING PRIVATE LIMITED L2 | Hydro Engineers L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | SITC of Transformer Oil Pump motor assembly set used for circulation of transformer oil in 14 MVA power transformers (compatible to the existing OFWF system)with following specifications:
CONFIGURATION: Elbow (end suction) glandless oil submerged motor on common shaft with impeller, High grade cast iron casing and bronze impellers, Fully weatherproof
Fluid Type: Transformer Oil
Power : 3.08HP, 2.3KW
No. of Phases = 3NO'S
RPM = 1420 rpm.
Inlet Suction Diameter = 4inch
Outlet Suction Diameter = 4 inch.
Capacity= 12 ltr/sec.
Insulation = Class-B
Head = 5.48 m
Frequency = 50 HZ
volts = 380-420 V
The job includes replacement of malfunctioning/ deteriorated pumps of 14MVA Power transformer banks including on site modifications, changes in design for fixing gaskets, wiring, control and protection, allied accessories, etc. required for the job. | 3 | Nos | 1,19,000 ₹3,57,000 Lowest | 1,50,000 ₹4,50,000 | 1,26,000 ₹3,78,000 | 1,35,000 ₹4,05,000 |
Tender Value
₹5.7 L
EMD Value
₹11,420
Closing Date
4 Jul 2026, 4:00 pmClosed
Executive Engineer
GENERATION DIVISION LJHP GANTAMULLA BARAMULLA
Replacement of old pumps motor set of 14 MVA transformer with new ones(03 no.) along with replacement of MK1 type motor starters with contactor-based starters with all protection systems
2026_SPDC_311944_1
E-NIT No 18 of 2026-27 dated 08.06.2026
Open Tender
Electrical Works
Item Wise
60 days
LJHP POWER HOUSE
Please refer Tender documents.
6 documents required · 6 mandatory
₹700
Yes
Executive Engineer
₹11,420
Yes
Executive Engineer
11 Aug 2026
9 Jun 2026
6 Jul 2026
10 Jun 2026
4 Jul 2026
10 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of Transformer Oil Pump motor assembly set used for circulation of transformer oil in 14 MVA power transformers (compatible to the existing OFWF system)with following specifications:
CONFIGURATION: Elbow (end suction) glandless oil submerged motor on common shaft with impeller, High grade cast iron casing and bronze impellers, Fully weatherproof
Fluid Type: Transformer Oil
Power : 3.08HP, 2.3KW
No. of Phases = 3NO'S
RPM = 1420 rpm.
Inlet Suction Diameter = 4inch
Outlet Suction Diameter = 4 inch.
Capacity= 12 ltr/sec.
Insulation = Class-B
Head = 5.48 m
Frequency = 50 HZ
volts = 380-420 V
The job includes replacement of malfunctioning/ deteriorated pumps of 14MVA Power transformer banks including on site modifications, changes in design for fixing gaskets, wiring, control and protection, allied accessories, etc. required for the job. | - | Nos | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
Tendernotice_2.pdf
PDF • 1.23 MB
BOQ_1009852.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .