| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC | ₹7.2 L Quoted ₹7.4 L | L1 | Accepted-AOC Found lowest as compare to all the bidders hence tender has been awarded to L-1 contractor |
| 2 | L2₹8.4 L+₹95,669.09 (12.9%)Rejected-Finance NEAR NEW BUS STAND ANNI DISTT KULLU H P | ANNI | KULLU | HIMACHAL PRADESH | ₹8.4 L+₹95,669.09 (12.9%) | L2 | Rejected-Finance L-1 is found lowest and other two bidders are put higher rate as compare to L-1 |
| 3 | L3₹8.4 L+₹1.0 L (13.6%)Rejected-Finance R O PURANA BAZAR KARSOG PO KARSOG TEH KARSOG DISTT MANDI H P 175011 | MANDI | HIMACHAL PRADESH | 175011 | ₹8.4 L+₹1.0 L (13.6%) | L3 | Rejected-Finance L-1 is found lowest and other two bidders are put higher rate as compare to L-1 |
Tender Value
₹9.9 L
EMD Value
₹24,814
Closing Date
29 Jun 2022, 10:30 amClosed
Er. Sushil Kumar, Sr. Executive Engineer,ED Karsog
Office of Sr. Executive Engineer,ED Karsog
Tender for providing 22KV HT Line to 63KVA 22/0.4KV S/Stn Batoni under ESD HPSEBL Seri.
2022_HPSEB_61925_1
184619/DB/2022-23-2266-72 Dated 18-06-2022
Open Tender
Supply and Erection
Item Wise
90 days
Seri
please refer tender document
10 documents required · 10 mandatory
₹1,180
₹24,814
25 Jul 2022
22 Jun 2022
29 Jun 2022
22 Jun 2022
29 Jun 2022
22 Jun 2022
Erection Part
Erection of steel tubular pole 9/10/11Mtr. (Long Single Pole Str of 22 KV HT Line): -Excavation of earth in all kinds of soil for making pits of size (1.8x1x1x) mtr. suitable for installing S.T.P. 9/10/11 M long, erection of S.T.P 9/10/11 M long with RCC muff in the excavated pit refilling of pit with excavated soil including watering and ramming etc. as required, disposing off surplus soil at the dumping site & local bodies, fixing of M.S clamps , stay clamps, stay wire,M.S channel cross arms,AI bracing,barbed wire danger plats, isulators nut & bolts including drilling,bending welding etc.as required, filling of RCC muffwith Cement concrete in ratio 1:2:4 (1cement:2 sand :4 concrete 20mm nominal size) from bottom to top painting of all steel parts and STP with two coats of aluminium paint A grade fixing of any other item required to complete the job, as per standard practice of HPSEBL as per the direction of Engineering in charges.
Erection of HT steel tubular pole 9/10/11 mtr. Long(Double pole structure:-Excavation of earth in all kinds of soil for making two numbers pits of size (1.8x1x1x)M each, suitable for installing STP 9/10/11 mtr long, erection of S.T.P 9/10/11 M long with RCC muff in the excavated pit, refilling of pit with excavated soil including watering and ramming etc. as required, disposing off surplus soil at the dumping site of local bodies, fixing of M.S clamps , stay clamps, stay wire, M.S channel cross arms, AI bracings,barbed wire, danger plats, isulators, nut & bolts,continuous earth wire with MS clamps, including drilling,bending welding etc.as required, filling of RCC muff with Cement concrete in ratio 1:2:4 (1cement:2 sand :4 concrete 20mm nominal size) from bottom to top painting of all steel parts and STP with two coats of aluminium paint superior grade and fixing of any other item required to complete the job, as per standard practice of HPSEBL/REC, as per the direction of Engineer-in -charge
Erection of HT stay set :-Excavation of earth in all kinds of soil foor making stay pit of size 1.2x1x1M, fixing of HT stay set ,nozelling and tightening of stay wire complete, refilling of pit with excavated soil including watering and rammining of soil,disposing off all surplus soil at dumping site of local bodies, fixing of any other material required to complete the job, complete in all respects as per standard practice of HPSEBL and as per satisfaction & direction of Engineer in Charges, complete in all respect.
Erection of HT earthing Set:-Excavation of earth in all kinds of soil for making pits of size (2.5x1x1mtr) fixing of HT earthing set with GI wire in pit refilling of pit with alternate layer of charcoal 40 Kg, salt 40Kg and soft soil, including ramming watering etc. as required, disposing of surplus soil at dumping site of local bodies, earthing of structure and allied material such as stay wire, isolators channels etc. with GI wire 6 SWG and P/fixing any otherpetty Items to complete the job as per satisfaction & direction of Engineer in Charges, complete in all respect.
Sagging of Conductor 1.00 Km. Single G.I. Wire/ AAAC/ACSR 20/25 mm2 : Laying, Stringing, Sagging & binding with insulator complete the job as per satisfaction & direction of Engineer in Charges, complete in all respect.
Sagging of Conductor : 1Km Single ACSR/AAAC 6/1/2.59mm (30mm2) : Laying, Stringing, Sagging & binding with insulator complete the job as per satisfaction & direction of Engineer in Charges, complete in all respect.
Extra Mannual carriage for an average lead of 0.200 Km from road side to site of work for Steel Tubular Pole 9/10/11 Mtr Long with allied material. For an average lead of 1.810/2+0.200 km
Providing and Supply of Material
Prov. G.I.No. 6/ 8 SWG for Earth wire for S/T Pole ( as per standrad specification of REC/HPSEBL , specification attached)
Prov. 22 KV Pin Insulator with Pin Hellically formed fitting (Porcelain, 12kV, 10kN) ( as per standrad specification of REC/HPSEBL , specification attached)
Discs insulator sets (comprising 2 No. Disc: ^^(Porcelain, BS, 12 kV, 90 KN) including Dead End Clamps etc.) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing C I X-arm (1800x100x50x6 mm) , ( as per specification attached)
Providing C I X-arm (1500x100x50x6 mm) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing C I X-arm (2800x100x50x6 mm) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing A I X-arm (2100x50x50x6 mm) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing A I X-arm (3000x50x50x6 mm) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing A-I Knee bracing set 2x(850x50x50x) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing Belt set (X- bracing set) 2(1500x50x50x5) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing Belt set (X- bracing set) 2(2700x50x50x5) ( as per standrad specification of REC/HPSEBL , specification attached)
Providing Stay wire 7/4.00mm Per pole 9 Kg ( as per standrad specification of REC/HPSEBL , specification attached)
Providing Half Clamp made of M.S. Flat 50x6mm suitable for 9/8 mtr ST ple as per the standard specification of HPSEBL ( as per standrad specification of REC/HPSEBL , specification attached)
Providing Full Clamp made of M.S. Flat 50x6mm suitable for 9/8 mtr ST ple as per the standard specification of HPSEBL at site of work.
Providing Top Clamp (Flat 50x6 mm) ( as per standrad specification of REC/HPSEBL , specification attached)
Prov. Earth Hook for Earth Wire ( as per standrad specification of REC/HPSEBL , specification attached)
Prov. Danger Plate (250x200x1.6 mm) ( as per standrad specification of REC/HPSEBL , specification attached)
Prov. MS Nuts & Bolts off size ( as per standrad specification of REC/HPSEBL , specification attached)
Providing Barbed wire ( as per standrad specification of REC/HPSEBL , specification attached)
Prov. 22 KV G.O. AB Switch Unit (11 KV, 400A, 25 KA) ( as per standrad specification of REC/HPSEBL , specification attached)
Prov. Aluminium Paint ( as per standrad specification of REC/HPSEBL , specification attached)
SUNEEL THAKUR ELECTRICAL
Koyla Engineering Works
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .