Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC | ₹2.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.7 Cr+₹6.4 L (2.42%)Rejected-AOC | ₹2.7 Cr+₹6.4 L (2.42%) | L2 | Rejected-AOC L2 |
| 3 | L3₹2.9 Cr+₹26.1 L (9.85%)Rejected-AOC | ₹2.9 Cr+₹26.1 L (9.85%) | L3 | Rejected-AOC L3 |
| Sl No | Description | Qty | Unit | HITECH BIO FERTILIZERS INDIA L3 | DREAM LIGHT WATER TECHNOLOGIES PVT LTD L2 | ELIXIRSOL L1 |
|---|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing, And Commissioning of Pumps & Pipelines from WTP to Underground Sump (Water Tank Tower) as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279 | ||||||
| 1.01 | Supply, Installation, Testing, And Commissioning of Level Switch (Including Redundancy Level Switch and Cable laying between Level Switches and Control Panel) in Treated Water Tank as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279 | 2 | Nos | 1,225 ₹2,450 | 1,211.65 ₹2,423.3 | 1,173.43 ₹2,346.86 Lowest |
| 1.02 | Supply, installation, testing, and commissioning of NSF-certified Triple layer PPR pipelines conforming to DIN 8077 / DIN 8078 standards, of PN16 pressure rating, having a minimum internal diameter of 116 mm, for treated-water conveyance from the Treated Water Storage Tank to the Treated Water Transfer Pumps. The item shall include all necessary straight pipe sections, couplings, and jointing accessories not covered under item number 7 of the BOQ, complete in all respects as per the technical specifications, drawings, and terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279. | 30 | Mtrs | 3,325 ₹99,750 | 3,141.26 ₹94,237.8 Lowest | 4,010.63 ₹1,20,318.9 |
| 1.03 | Supply, Installation, Testing, And Commissioning of Suction Diffuser required for the Treated Water Transfer Pump as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279 | 2 | Nos | 49,100 ₹98,200 | 48,621.88 ₹97,243.76 | 47,088.22 ₹94,176.44 Lowest |
| 1.04 | Supply, Installation, Testing, And Commissioning of Treated Water Transfer Pump with OEM's IE5 Motor, Predictive Sensors & Sensor Suite, Cloud Monitoring, Control & Predictive Analytics Platform, IIOT Gateway, Oracle EAM API, Centralised Command Dashboard and Oracle EAM Integration Modules as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279. The cost for the pumps, motors, automation requirement, cloud/GPRS services has to be considered for a period of three years so as to satisfy all the conditions mentioned under clause no 5.6 of the special conditions of contract. (Approved make and native platforms to be considered : Refer to '5.6 D' unders Special conditions of the contract.)
In addition to the above, the contractor should also quote the rate of condition monitoring system if all the specifications mentioned under clause no: 5.6 A (3) and 5.6 B of the special conditions of contract are not covered under the OEMs (Armstrong, Grundfoss, Xylem, Wilo) native platform/sensors/cloud services considered by the contractor. The cost should include the rate for the required sensors to satisfy the requirement as mentioned in the tender for predictive maintenance (mentioned under clause no: 5.6 A (3) and 5.6 B of the special conditions of contract) including the amount for condition monitoring sensors, communication gateway, GPRS/Sim charges and cloud charges for digital twin capability for a period of three years. Approved makes for condition monitoring system: ABB/Siemens/Schaeffler. | 2 | Nos | 10,75,000 ₹21,50,000 | 10,07,102.75 ₹20,14,205.5 | 8,43,447.43 ₹16,86,894.86 Lowest |
| 1.05 | Supply, installation, testing, and commissioning of Variable Frequency Drives (VFDs) for the pumps installed at the Water Treatment Plant (WTP). The VFDs shall ensure Total Harmonic Distortion of current (THDi) less than 5% and Total Harmonic Distortion of voltage (THDv) less than 5%, achieved through the use of Active Front-End (AFE) drives and/or suitable harmonic filters.
The system shall be fully compliant with IEEE 519:2022 and the relevant technical specifications and tender conditions.
If the AFE drive or harmonic filter is integrated within the pump package supplied by the OEM, the bidder shall ensure compliance with the above harmonic distortion limits and quote the corresponding cost for the integrated VFD and AFE/filter system under this item. | 2 | Nos | 2,48,100 ₹4,96,200 Lowest | 2,95,414.73 ₹5,90,829.46 | 2,86,096.56 ₹5,72,193.12 |
| 1.06 | Supply, Installation, Construction, Testing, And Commissioning of Foundation required for the Treated Water Transfer Pump as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279 | 1.5 | m3 | 35,000 ₹52,500 | 34,618.64 ₹51,927.96 | 33,526.68 ₹50,290.02 Lowest |
| 1.07 | Supply, installation, testing, and commissioning of NSF-certified Triple layer PPR pipelines conforming to DIN 8077 / DIN 8078 standards, of PN16 pressure rating, having a minimum internal diameter of 116 mm, for Treated Water Transfer Pumps to Underground Sump (Water Tank Tower) & Overhead Tank (Water Tank Tower). The item shall include all necessary straight pipe sections, couplings, and jointing accessories not covered under item number 7 of the BOQ, complete in all respects as per the technical specifications, drawings, and terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279. | 700 | Mtrs | 3,325 ₹23,27,500 | 3,141.26 ₹21,98,882 Lowest | 4,010.63 ₹28,07,441 |
| 1.08 | Supply, Installation, Testing, And Commissioning of Pressure Gauge for each Treated Water Transfer Pump as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279 | 2 | Nos | 4,805 ₹9,610 | 4,760.06 ₹9,520.12 | 4,609.92 ₹9,219.84 Lowest |
| 1.09 | Supply, Installation, Testing, And Commissioning of Pressure Transmitter for Treated Water Transfer Pump Discharge Header as per the technical specifications, terms and conditions of the tender document ETPK/PH-I/2025-26/AT-279 | 1 | Nos | 14,850 ₹14,850 | 14,712.92 ₹14,712.92 | 14,248.84 ₹14,248.84 Lowest |
Tender Value
₹2.5 Cr
EMD Value
₹1 L
Closing Date
30 Oct 2025, 4:00 pmClosed
Chief Executive Officer
Park Center, Technopark Phase I Campus, Trivandrum
UPGRADATION OF THE EXISTING MAIN WATER DISTRIBUTION SYSTEM OF TECHNOPARK PHASE I CAMPUS
2025_ETPK_812702_1
ETPK/PH-I/2025-26/AT-279
Open Tender
Miscellaneous Works
Item Rate
120 days
Technopark Phase I Campus, Trivandrum
Please refer Tender documents.
2 documents required · 2 mandatory
₹8,850
₹1 L
21 Nov 2025
21 Oct 2025
31 Oct 2025
21 Oct 2025
30 Oct 2025
21 Oct 2025
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1358281.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.10 MB
TENDER.pdf
Tender Documents • 1.56 MB
BOQ_1358281.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .