Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹74.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹83.9 L+₹9.8 L (13.3%)Rejected-AOC | 2 | Rejected-AOC L2 |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
25 May 2022, 5:00 pmClosed
Executive Engineer
Executive Engineer, Uttarakhand Jal Sansthan Khatima
Construction of Dhyanpur (SVS) Water Supply Scheme including, Supply Installation and testing of Rising Main, Distribution System, FHTC work, repairing of OHT and all appurtenance work etc. complete under Jal Jeevan Mission program
2022_UKJS_44299_2
445/E-Tender Notice/2022-23 date 27.04.2022
Open Tender
Civil Works - Water Works
Item Wise
180 days
Khatima
Please refer Tender documents.
2 documents required · 2 mandatory
₹4,720
Executive Engineer UJS
₹1.7 L
Khatima
14 Aug 2023
10 May 2022
27 May 2022
10 May 2022
25 May 2022
10 May 2022
12 May 2022
Rates for Construction of Dhyanpur (SVS) Water Supply Scheme including, Supply Installation & testing of Rising Main, Distribution System, , FHTC work, repairing of OHT & all appurtenance work etc. complete under Jal Jeevan Mission program.
Dismantling manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge :bituminous road
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 meters lead as per direction of Engineer - in -charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.
Providing, Lowering into trenches with true to alignment. Laying & Jointing of full Length of HDPE Pipes of specified grade as per IS:4984-1995 and specifications with testing of pipe line including supply of jointing materials.(PE-100 Grade, PN-8(8.0 Kg/Cm2) Normal Pressure (PN) in 8.0 Kg/Cm2 63mm PN8
Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I screwed pipes (including supply of all jointing materials like specials, white lead, hemp and oil etc.) in trenches with its cutting, threading and testing of pipe line etc. 15 mm dia
80 mm dia
100 mm dia
100 mm dia
150 mm dia
200 mm dia
C.I. D/F Non Return Valves 100mm dia
Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4"graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design
Constructing masonry Chamber 120x120x100 cm, inside with 75 class designation brick work in cement mortar 1:4(1 cement: 4 coarse sand ) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement: 2 coarse sand : 4"graded stone aggregate 20 mm nominal size ) necessary excavation foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3(1 cement: 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design
Providing and making House service connection from water supply distribution pipe line etc. complete
RCC OHT Repairing work
Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge decketc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shallcarry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm
For horizontal surface one coat @1.10 kg per sqm.
Providing & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatious waterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineer-in-Charge.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.
Removing dry or oil bound distemper, water proofing cement paintand the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On concrete work
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete. On steel work
12 mm cement plaster finished with a floating coat of neat cement of,mix :1:4 (1 cement: 4 coarse sand)
Supply & applying of water based bio-degradable epoxy polymide chemical on MS flange for repairing of water leakage including all labour material T&P etc. complete as per direction of Engineer-in-Charge. Repairing of OHT column pipe joints with pipe joints sealents upto 0 to 10 feet height
Repairing of OHT column pipe joints with pipe joints sealents upto 10 to 20 feet height
Repairing of OHT column pipe joints with pipe joints sealents upto 20 to 30 feet height
Repairing of OHT column pipe joints with pipe joints sealents upto 30 to 40 feet height
Repairing of OHT column pipe joints with pipe joints sealents upto 40 to 50 feet height
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supply and installation of Water level indicator (II level) including one set of sensor with its holding parts, 54 meter sensor cable armued with steel wire.
Pump House Repairing work
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, hitrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand).
12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Grading roof for water proofing treatment with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm mominal size.
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece.
Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. Door chowkhats.
Window chowkhats.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm)on existing cement paint surface
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture.
Supply of RS joist (ISLB) 300mm x 150mm & 9.40mm thick size & 4.00m long and fixing with 1:2:4 PCC over columns in position. (wt. of ISLB [email protected]/m)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group B Long Discrpition)
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVCinsulated copper conductor single core cable for loop earthing as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Fire Hydrant work
Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design
P/F fire Hydrant valve confirming to is: 5290 (flanged) in position including all material, labour T&P etc Complete 80 mm dia
Electrical & Mechanical works
Supply of energy efficient submersible pumpsets of various duty parameters, as per IS 8034 - 2002 and IS 9283 - 1995 with latest amendments Pump of 600 LPM discharge at 50 m head
Supply, installation, testing and commissioning of three phase Electronic Automatic Voltage Stabiliser suitable for unbalanced voltage and unbalance load including fixing of proper size copper lugs on input and output cables on both ends at different sites on turnkey basis including five year cost free maintenance. Input voltage 280V/460V/240V(Three phase) Servo Voltage
Supply and fixing of H.R.C. main switch 3 pole with neutral link in 100amp. 440 voltage A.C.
Supply and fixing of 100 mm dia x 5.6mm thick flanged column pipe in 3m length with inter locking arrangement
Supply and fixing Rubber insulation sheet 1 Mt. x 2Mt. X .025Mt.
Supply of chain pully block having capacity 3 Ton with 6 meter chain.
Supply, Fixing and installation of Display and Sign. Board (8’ x 6’) size with Jal Jeewan Mission logo (1’5” x 2’) including letter & slogan writing etc at specified space as per JJM guidelines & as per direction of engineer-in-charge.
M/S Guru contractor
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .