| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L1₹12.2 LRejected-AOC LAXMANPUR CHOWK VIKASNAGAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Rejected-AOC L3 | |
| 3 | L2₹12.2 LRejected-AOC 916 9 AWAS VIKAS COLONY RISHIKESH | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC L2 | |
| 4 | Rejected-Technical AZAD NAGAR HALDWANI NAINITAL | HALDWANI | NAINITAL | UTTARAKHAND | - | Rejected-Technical PQR Not Qualified |
Tender Value
Refer Docs
Closing Date
14 Jul 2021, 5:00 pmClosed
Executive Engineer
56-Special Wing, Near Amitabh Textile Mill, Premnagar, Dehradun
Increasing capacity of Transformer of different capacities in EDSD Selaqui and Mohanpur under EDD Mohanpur
2021_UPCL4_34294_1
07/2021-22
Open Tender
Supply, Erection and Commissioning
Item Rate
30 days
EDD Mohanpur
As per Tender Document
4 documents required · 4 mandatory
₹590
Executive Engineer,EDD Mohanpur
Exempted
29 Sept 2023
7 Jul 2021
15 Jul 2021
7 Jul 2021
14 Jul 2021
7 Jul 2021
Amount
Cartage of ST & PCC Pole from store center to Cnstruction site with loading, unloading at both points and proper stacking
ST POLE SP-33
PCC POLE
Cartage of T/F and other item from Aaraghar to S/S road side 27km approx distance
Carriage of Stock material
Head load Cartage of following poles from road to site
ST POLE SP-33
PCC POLE
Mannual Shifting of T/F
Mannual Shifting of Stock material
Dismentaling of old T/F from D/P Structure and opening of all connection from LT and HT Side
Back head load cartage of T/F by head load from S/S to road side
Mounting of 11/0.4KV, T/F Double pole with fixing of all accessories & Making both
Back Cartage of old Transformer from road head to ESC araghar
Providing & Fixing of Danger Board number plate complete by providing clamps of MS flat 50x6mm and making of all conection of HT and LT side and its complete commissioning.
Laying and errection of LT PVC Cable including Crimping of lugs of size 1x120 sqmm
Laying and errection of LT PVC Cable including Crimping of lugs of size 1x240 sq mm
Dismentaling and Reconnection of LT Service Cable line
Opening and Fixing of Existing Consumer Connection
Fabrication of M.S Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc, as per RESSPO schedule and local approved drawing.
Excavation of earth for stay pit of size .6x.6x1.2 mtr in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work.
Fixing Tightening and nozzzling of stay with pole
11 KV line
LT Stay
Grouting of stayin size .6x.x.3 in CC raio 1:4:8 block including cost of cement sand and stone blasst back filling of soil and boulders in pt and ramming and proper alignment, leveling as per RESSPO construction mannual
Earthing of support with M.S earthrod of 2.5 meter long by hammaring of M.S rod to proper depth and connecting the earth electrode with the help of G.I wire as per construction mannual
Making and fixing of T/F base
Fixing and installation of LT Fuse set
Making of section pole for existing LT line complete in all respect
Laying of AB Cable Size 3x120+1x95 sqmm
Laying of AB Cable Size 3x95 sqmm
Dismentaling of existing LT/HT line including disc fitting, insulator clamps nut&bolt and consumer connections and street light connection etc, including rolling of conductor and cartage back from site to JE Store
3P 5W wire Length ACSR Weasel Conductor
Laying Spreading, Stringing and Sagging of L.T lines of the following wire as phase wire with G.I earth wire complete with binding and jumpering as per RESSPO Spech.
3P 5W wire Length ACSR Weasel Conductor
Laying Spreading Sagging 1P 2W line for Converting 1P 2W line into 3P line
Chemical Earthing : Earthing of distribution transformer including digging of pit of size 2.5 mtr depth and make hole of size 150mm placing of earthing electrode as drawing B, connecting the same with GI strip of size 35x6 mm as per drawing C for a minimum length 6m treatment of soil with highly conductive substance as per IS 30343 complete in all respect, reasult of earthing resistance to be recorded in M.B before and after installation of earthing, The earth resistance after earthing should be less than 1 OHM.
Excavation of Earth for pole pit of size 0.9x0.6x1/6 of full length of pole for errection of pole in all type of soil including proper dressing of sides and ramming of bottom including getti out te excavated soil and disposal of surplus excavated soil as directed complete.
Errection of Single support pole inproper level and alignment along with fixing of all accessories, like top channel & clamps as per RESSPO Consruction mannual
ST POLE SP-33
PCC POLE
Errection of Double Support Pole
ST POLE SP-33
Grouting of pole in size 0.45x0.45x1/6 of the support in CC ratio 1:4:8 block including cost of cement sand and stone ballast back filling of soil and boulders in pit and ramming and proper alignment leveling as per ESSPO construction mannual
Muffing of pole size 0.45cm x0.60 cm radious with CC 1:3:6 block size 45cm height from ground level including cost of cement stone and sand etc
Fixing of triangular type bracket/single pole accessries in 11 Kv line
Fixing of D- Type Bracket in LT Line
Making Special type separate earthing for netural/body of power transformer by digging 3x4x12 feet deep pit at corner of switchyard with duly provided 1 No. Copper plate of size 18"18""1/2" Jointing them with 6" long bolt duly covered withlayer of softcoal 60kg and salt 20kg (total 80kg) the earth plate shall be connected with 35x6 mm GI strip and GI strip Shall be laid upto the netural and T/F body sepatately (including supply of steel).
Guarding of line over (Telephone/Road/LT line crossing as per drawing with 6/8 SWG G.I wire including fixing of guarding Channel/angle as per RESSPO mannual LT/11KV/33KV liine
Mounting and fixing of lightening arrestor set (3 nos) on double pole structure including making all connections by GI strip size 35x6 mm to earth point complete work.
Fixing of extra clamps and insulator on PCC Pole
Major Repairing of T/F Plinth for 400 KVA T/F Complete work as per norms
Errection & Providing and fixing of wire mesh of size 50x35mm around plinth and toe wal
Painting of poles with angle and channel and all steel part by one coat of Red Oxide primer and two coats of aluminium paint and two strip of fluorecent altemate red and white paint 30cm wide upp to .5 mtrs from groud level.
ST POLe SP-55
ST POLe SP-33
Replace and new fixing & installation of LT fuse set
Dismentaling of fuse set on the double pole structure
Errection of LT XLPE Cable 120sqmm
Route Clearence of Cutting of tree branches/pronmg, looping Chopping of trees
T-off Connection Complete 11/33KV line
RE-alignment of TPMO on existing Double pole with Digging of pit and fixingof TPMO on the double pole with smooth operating including making of gung and jumpher with binding kit
Dismentaling of LT AB Cable
RE-laying of above Dismentled LT AB Cable
Re Jumpering of Double Pole
supply
AL Lug 120 Sqmm
AL Lug 240 Sqmm
Shackle Insulator 75x90mm with N&B
LT Clamp for ST Pole with N&B (50x6)
LT Clamp for PCC with N&B (50x6)
LT Shackle insulator with N&B (100x115)
Stay Clamp for St Pole SP-33 pole with N&B (50x6)
LT Clamp for ST Pole Sp-33 With N&B (50x6)
PP & Clamp of SP-33 Pole (50x6)
All Crimping lug 400sqmm
Earth Clamp for ST Pole SP-33 (50x6)
LT Fuse Set
Holding Clamp for ST Pole SP-33 (50x6)
MS Nut & Bolt off Size
M/S R. B. ELECTRICALS
garg enterprises
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .