| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC LOWEST AND REASONABLE RATE | |
| 2 | L2₹28.0 L+₹5.1 L (22.2%)Rejected-Finance WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance HIGHER RATE |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ARMY BHUJ
BHUJ
REPAIR REPLACEMENT OF LT DISTRIBUTION LINE AND OTHER CONNECTED WORKS UNDER AOR OF AGE EM OF GE A BHUJ AT MIL STN BHUJ AND KHAVDA
2024_MES_653411_2
8209
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE ARMY BHUJ
₹50,000
Yes
19 Sept 2024
28 Jun 2024
24 Jul 2024
28 Jun 2024
22 Jul 2024
3 Jul 2024
Amount
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc for laying of cables, erection of poles, struts/ stays etc not exceeding 10 sqm on plan and getting out in soft loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and directed.
Removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in soils complete all as specified and directed.
M & L for sand filling in trenches for cushioning of LT cables punning after filling complete as specified and as directed. Note: Punned thickness shall only be measured and paid
Supply and lay un-reinforced precast concrete cable cover , class , LV , Type I flat size 250 x 150 x 40 mm laid dry in treches over under ground cables complete all as specified and directed.
S & F GI pipe, light grade, of size 50 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection complete all as specified and directed.
S & F GI pipe, light grade, of size 40 mm dia including necessary fittings laid in trenches/fixed on wall/pole for LT cable protection and taking down the old GI pipe, complete all as speicifed and directed for cable protection complete all as specified and directed.
Supplying ,Laying, jointing and testing new XLPE insulated, armoured, heavy duty, LT aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed of size 2 core 6 sqmm complete all as specified and directed.
- do- as per Item 8 here in above but of size 4 core 10 sqmm
- do- as per Item 8 here in above but of size 4 core 16 sqmm
- do- as per Item 8 here in above but of size 3.5 core 25 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 35 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 50 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 70 Sqmm
- do- as per Item 8 here in above but of size 3.5 core 95 Sqmm
M&L for Disconnecting, taking out, removing old existing unserviceable LT underground cable of any size complete all as specified and directed.
Material and labour for bring the van mounted full automated underground cable fault locator machine at site for find out HT/LT cable fault in underground completely complete all as specified and directed. Note: (a) Fault machine,cable & T&P required shall be arranged by the contractor. (b) Cable jointing kit for LT is measured separately
M&L for refreshing of incomming and all outgoing XLPE cable of any size including excavation for removing cable loop , refreshing of exsiting all cable by removing insulation ,including removing old damaged lugs and fixing of suitable size lugs, PVC conncetor,dressing of all cables . nuts ,bolts,washer to all incomming and outgoing MCCB , insulating all bare conductor with insulating cable of suitable colour complete all as specified and directed. Note: 1.Cable Lugs and insulator shall be measured and paid in appropirate item of schedule. 2.Labour charges of following item shall be deemed to include in quoted rate.
Supply only timbles/lugs of any size and type complete all as specified and directed.
Supply only post insulator of any size and type complete all as specified and directed.
Supply only LT insulation tape ISI marked complete all as specified and directed.
M&L for replacement of damaged iron hinges, iron latch of LT panel including welding of news hinges , fixing of new stainless steel latch 8 inch to panel door complete all as specified and directed.
M&L for restring of LT Over head aluminium conductor of any size including taking down aluminium conductor and refixing the same conductor to insulator including aluminium binding works for connceting insulator and conductor , tighting of pin insulator , MS channel refixing of outgoing conductor ,removing all old unservicable tapping from pole complete all as specified and directed.
supply and fix Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 65mm dia for 550 volts grade complete all as specified and directed.
Supply and fix in repiars the following items and disconnecting,taking out the old unserviceable one, including necessary replacemnet of lugs ,nuts,bolts lugs of any size and capacity wherever reqd :-
MCCB Thermal Magnetic release,Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 63 Amps 16 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 100 Amps 16 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 160 Amps 36 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 250 Amps 36 KA.
MCCB Thermal Magnetic release Ics=100% of Icu, Adjustable over load 0.8 to 1 In,Adjustable Short circuit current 6-10 In , 4 pole 400 Amps 36 KA.
M&L for removing shrub and creeper on electrical pole ,electrical panel ,at substation ,chain link fencing on hardstanding pcc complete all as specified and directed.
supply and fix in repiar on load changeover 415V 100A with enclosure, disconncetion & taking down and reconnection with proper size of lugs complete all as specified and directed.
supply and fix in repiar on load changeover 415V 160A with enclosure disconncetion & taking down and reconnection with proper size of lugs complete all as specified and directed.
Supply, installation, testing and commissioning CPRI approved weather and vermin proof LT Panel box factory fabricated out door cubicle type (KIOSK type ) , front and back openable , air vent , totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement with pad lock consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber /wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/ externally of approved colour with PCC foundation and civil work and copper bus bar for 3 phase & neutral mounted on epoxy insulator-01 Set including sleeves as per colour coading and connecting the following :-(LP panel-2)
Incoming
(a) Copper Bus bar,150 Amps TPN -01 set
(b) MCCB 4 Pole thermal magnetic release 415 volts 100 A 35 KA-01
(g) Indicating lamps ( LED type) ( R-Y-B) -01 (Set of three)
(f) Digital Multifunctional meter - 01 No
Outgoing
(a) MCCB 4 Pole thermal adjustable magnetic release 415 volts 25 A 16 KA-05(4 working +01 stand by)
Supply and fixing in replacement old unserveceable cable junction box with new pole mounted thermoplastic cable junction box of size 300x200x105mm or next higher size for street light with IP-65 protection, weather proof with metric knockouts for cable entry for outdoor installation with front door opening system, copper busbar suitable capacity with RYBN & sleeves as per colour coding, cable gland for incoming and outgoing cable according to cable size including terminals for one incoming and two outgoing cables of size 16/25 sqmm 4 core, one MCB SP 6 Amp 240V AC with mounting on DIN rail, clamp of flat iron, nut, bolt and washers complete all as specified and directed .
M&L for three core PVC insulated sheathed(heavy duty) unarmoured copper conductor multi stranded cable (for phase, neutral and earth ) of size 1.50 Sqmm for connection drawing through pole or GI brackets from junction box to light conncector of street light fittings including heavy duty PVC conduit of size 20mm dia, lugs /thimbles according to size of cablecomplete all as specified and directed.
supply and fix PVC copper cables from bus bar to MCCB inside panal including nuts bolts washer ,drilling holes in to bus bar of following sizes:-
a)10 sqmm PVC single core
b)16 sqmm PVC single core
c)25 sqmm PVC single core
d)25 sqmm PVC single core
e)50 sqmm PVC single core
Supply and fixing 11KV fuse wire of any type and size complete all as specified and directed.
Notes :-(1) The contractor shall keep all items readily available at site, which is required for urgent repair works.
(2) Common miscellaneous material such as screws any type, nails, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.
(3) All tools &tackles, plants, machineries, equipment and material to carry out the work at site which is to be decided by GE (A) Bhuj shall have to be provided by the contractor at his/ her own cost.
(4) Contractor’s supervisor (electrical engineer) should be available at the site to supervise the works and co-ordinate with the officials.
(5) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at various places and forwarded to administration.
(6) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.
(7) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.
(8) It is responsibility of contractor to clean the area after repairwork of appliances. Rates are deemed to be include in his quoted rates of respective items.
(9) Any of contractor persons causes damage of equipment or property of Militart station, the contactor will be solely held responsible for the cost of consequences thereof.
(10) Joint measurement weekly. The contarctor should be availble for joint measurement along with supervisor on every Wednesday/as decided by Enginner-in-charge.
(11) Stationery such as complaint register, Job card/Docket , work diary ,hindrance register, site order register etc shall be supplied by the contractor
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.
M/s Bombay Novelty Stores (BID ID -3069340)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .