Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹32.3 L+₹1.2 L (3.75%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance NON BONAFIED | |
| 3 | L3₹32.9 L+₹1.8 L (5.72%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | BAPATLA | ANDHRA PRADESH | 504214 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹35.1 L+₹4.0 L (12.8%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹35.2 L+₹4.0 L (12.9%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MANNING AND OPERATION OF AC PLANTS AT 600 LT NEW BARRACK WORK SHOP NEW COLD COOL ROOM AC PLANTS AT NAD UNDER AGE EM NO II OF GE U II VISAKHAPATANAM
2020_MES_379032_2
8742
Open Tender
Electrical Maintenance Service
Item Rate
330 days
Garrison Engineer Utility-II Visakhapatnam
CLASS D
11 documents required · 11 mandatory
₹500
Garrison Engineer Utility-II
₹90,000
Yes
8 Dec 2020
27 Oct 2020
18 Nov 2020
27 Oct 2020
17 Nov 2020
5 Nov 2020
60 days
Amount
SCHEDULE "A' PART - I
Manning, operation and maintenance of 600 LT (New) AC Plants 3x25 TR with connected items, at P-346, NAD of Accel make Model No. SMC 65, direct expansion type including attending to minor defects for smooth and trouble free operation and keeping an hourly record of plant and inside room temparature complete, round the clock in 03 shifts of 08 hours each, by providing one skilled operator in each shift of 08 hours duration, including sundays and holidays complete all as specified and as directed.
Manpower :- One Skilled Operator per shift. Shift timings:- Ist shift : 0600 Hrs to 1400 Hrs 2 nd shift : 1400 Hrs to 2200 Hrs 3rd shift : 2200 Hrs to 0600 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning, operation and maintenance of AC Plant DX type 3x40 TR with connected items, at Barrack Missile work shop NAD of Voltas make Model No. 5H40, including attending to minor defects for smooth and trouble free operation and keeping an hourly record of plant and inside room temparatures complete, round the clock in 03 shifts of 08 hours each, by providing one skilled operator in each shifts of 08 hours duration, including sundays and holidays, complete all as specified and as directed.
Manpower :- One Skilled Operator per shift. Shift timings:- Ist shift : 0600 Hrs to 1400 Hrs 2 nd shift : 1400 Hrs to 2200 Hrs 3rd shift : 2200 Hrs to 0600 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning and operation and maintenance to Cold Room Plant of Capacity 3 x 20000 BTUH (-16 degree to -20 degree centigrade) and cool room plant of capacity (3 x 10000 BTUH (plus 2 degree to plus 8 degree centigrade) with connected items, at BV Yard, Visakhapatnam of Blue Star make, including attennding to minor defects for smooth and trouble free operation and keeping in hourly record of plant and inside room temperatures complete round the clock in 03 shifts of 08 hours each, by providing one skilled operator in each shift of 08 hours duration including sundays and holidays, complete all as directed by Engineer -in- Charge.
Manpower :- One Skilled Operator per shift. Shift timings:- Ist shift : 0600 Hrs to 1400 Hrs 2 nd shift : 1400 Hrs to 2200 Hrs 3rd shift : 2200 Hrs to 0600 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Note for SL item Nos. 1 to 3: (i) Rate quoted shall be deemed to be inclusive of prevention of minor breakdowns, maintenance of all equipments by replacement of bolts, nuts, washers, greasing, gland packing to pump, checking, filling of oil level in compressor, leak test, 'V' belt, electrical control wiring, minor repairs if any etc, but excluding major repairs to plant. Taking care of house keeping environmental cleanliness, cutting grass, small plants etc.,.surrounding area of installation, all round around installation shall be kept absolutely neat and clean. Cost of all consumable stores such as grease, lubricants ( Excluding compressor oil), cotton waste, minor spares and other required stores for daily opeartion and maintainance. One emergency light and necessary tools should be available in a tool box with operator for smooth functioning. (ii) The quoted rate is also inclusive of maintain logsheets, maintaining record of room temparatures on hourly basis and uniform of duty persons.
Note 1 for SL item Nos. 1 to 3: Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Note 2 for SL item Nos. 1 to 3: 1. Contractor shall quote wages, employers contribution towards EPF liability, contribution towards ESIC, contribution towards bonus, LWC and overhead & profit separately as applicable as per instruction in vogue in respective sub items. 2. The rate quoted for items of outsourcing / Manning shall not be less than minimum wages as notified by Government of India/concerned state Government/Local Body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective heading / sub-items. In case any quoted rate against the above items / subitems mentioned above which correspond works out to lower than the prevailing minimum rate of wages / subscription / contribution towards EPF / ESIC/ Bonus / LWC the bid will be treated as non bonafide / invalid, shall be disqualified.......
...... and such bids will not be considered for acceptance. In such case, the lowest bidder shall be determined from amongst the valid / bonafide bids only and no claim on this account is entertained. The prevailing rate / wages / contribution shall be as applicable on the bid submission end date. 3. (a) The contractor shall submit the ID Proof, Bank Account No, EPF account number and ESIC account number of Operator / Person Employed. (b) The payment shall not be less than minimum labour wages and payment of labour / employee shall be made through Online Banking like NEFT/ RTGS etc,.
(c) The quoted rate in sub items of wages, EPF, ESIC and Bonus will be released only after producing authenticated Documentary proof of payment as per prevailing rates deposited in the concerned employees account duly signed by contractor and shall be submitted along with RAR / final Bill for payments. 4. Quotations with 'Nil' or "Zero" consideration (overhead and profit) will be considered non bonafide. 5. Any variation in minimum wages, liability of EPF / ESIC / Bonus / LWC / GST shall be adjusted for reimbursement/ Recovery as under:- (i) Variation in minimum wages including other related statutory provisions shall be adjusted in tems of condition 63 of GCC (IAFW-2249). (ii) Variation in percentage/ rate of GST and LWC shall be adjusted as per special conditions here in after which deals with "Reimbursement / Refund on Variation in Taxes Directly Related to Contract Value.
(iii) Rates shall be quoted only upto two digits after decimal. If any rate quoted/ derived by the contractor works out to more than two digits after decimal, then the same shall be rounded off upto two digits after decimal. The rounding off shall be done in accordance with rules for rounding off of Numerical Values in accordance with IS: 02 pf 1960 (Revised 2016) of BIS. 6. The contractor will be required to submit copy of valid labour licence from the labour Commissioner within 15 days of commencement of the work. If the contractor fails to submit the same within this stipulated period the contract shall be liable to be cancelled and the performance Security of the firm shall be forfeited accordingly.
7. (a) In case of requirement, tradesmen provided for one area may be utilised in other areas at the discretion of the department without any extra cost to department as directed by Engineer-in-Charge. (b) Tools & plants shall be provided by contractor. (c) Temporary laying of LTUG cable of any size and any lenth for restoration of supply during break down / other requirement deemed to be included in the above quoted rate. (d) Complaint register and Complaint slip books as per site requirement shall be provided by the contractor and cost of the same is deemed to be included in the quoted rate. (e) All workers employed by the contractor shall be in proper uniform with name plate and other safety wearing items , shoes during the duty as per the electricity rules, which deemed to included in quoted rate.
(f) Departmental equipments of each installation,shall be under safe custody . In case of theft of any item from installation recovery shall be made from the contractor as per direction of Engr-in-charge. (g) Group insurance for the operators shall be made by the contractor. Documents shall be submitted to the department. (h) Rate quoted shall be deemed to include for leave/reserve of staff.
SCHEDULE "A' PART - II
Supply and replace KP-15R LP/HP cut out switch with 2.5 Sqmm multistranded copper wire -12 Metre long, wire lugs - 24 Nos, cable Ties - 01 Packet, insulation tape - 02 Nos, toggle switches - 03 Nos, copper pipe ¼” Soft - 20 RM, Brass Flare Nuts - 24 Nos, Teflon tape-10 Nos, Piano switches with gang Box - 01 No with necessary screws, nuts and Bolts including drilling, taping and proper dressing complete all as specified and directed by Engineer-in-Charge. Make :- Danfoss / Indfoss.
Supply and replace MP-55 Oil Pressure cut out switch complete all as specified and directed.
Supply and replace Compound Gauge of range 30-0-300 PSIG of Size : 2 ½” complete all as specified and directed. Make: HGURU /FIVIK
Supply and replace Compound Gauge of range 30-0-300 PSIG of Size 4” complete all as specified and directed. Make: HGURU /FIVIK
M&L for carrying out leak test of Central AC plant unit of capacity up to 110 TR with use of nitrogen gas and rectifying the leakages, arresting the leakages and including charging gas, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
M&L for carrying out leak test of Package AC Plant units of capacity from 10 to 40 TR with use of nitrogen gas and rectifying the leakages, arresting the leakages and including charging gas, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
M&L for carrying out leak test of Ductable package/split AC plants of capacity up to 5.5 TR with use of nitrogen gas and rectifying the leakages, arresting the leakages and including charging gas, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
All as per Sl. Item No. 10 above but 7.5/8.5 TR. (Note for Sl item No 8 to11:- (i) Necessary copper pipes, welding works are deemed to be included in the quoted rate. (ii) Refrigerant gas R-22/R134A/R410A/ R407 / R404 will be measured and paid separately.)
Supply and charging refrigerant gas R-22. Make:- Floron/Mafron
Supply and charging refrigerant gas R-134A. Make:- Floron/Mafron
Supply only refrigerant gas R410A / 407 / 404A (Make:- Floron/Mafron)
Supply only compressor oil. Make: Veedol 68 / Sheetal N-68
M & L for Repair/servicing of non chemical type online electrostatic scale preventor of size 100mm bore including replacing rusted nuts, bolts and gaskets complete all as directed by the Engineer-in-Charge
All as per above item Sl item No.16 but of size 80mm dia.
Supply and fixing in repairs MS ERW pipe medium with all fittings laid in trenches, floors or fixed to walls and ceilings etc of following size pipes including cutting of exisiting defective pipe, fixed with specials, leak testing, complete all as specified.
80 mm bore of pipe.
100 mm bore of pipe.
125 mm bore of pipe.
M&L in repairs Synthetic mat (rubber matting) suitable for 11000 Volts electrical grade 2mx1mx19mm thick chequered top, ISI marked to be laid in front of LT panel board complete all as speicfied and directed.
Supply & laying in trenches or fixing on wall or passing through pipe or in cable ducts XLPE insulated PVC FRLS, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded copper conductor of size 4 Core 70 Sqmm including taking out old un-serviceable cable complete all as specified and directed.
Supply & replacement of CT Coil including testing and commissioning complete all as specified and directed by Engr-in-Charge .
Supply, install, commissioning and testing Capacitor bank for 3 phase, 415 V & 50 Hz system of following capacity including dismantling one etc., complete all as specified and directed by Engr-in-charge .
Excavation in trenches n.exc. 1.5 m wide and n. exc. 1.5 m in depth and getting out in soft / loose soil for foundation, of pipe lines etc, complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in soil complete all as specified and as directed.
Removing excavated soil to a distance not exc. 50 m and depositing where directed at a level not.exc. 1.5 m above the starting point complete all as specified and as directed.
Supply and spreading clean dry sand for cable cushioning in trenches complete all as specified and as directed. Note: Punned thickness shall only be measured and paid.
Supply and laying Sub Class 'B' bricks of old size (23x11x7cm) laid along aligment of cable as protection to cable in trenches complete all as specified and directed by Engineer-in-charge
M&L for PCC 1:3:6 type C1 (using 20 mm graded stone aggregate) for making good surface where cutting road / hard standing / path complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) in bases / pedestals for pipe lines, mud stops or chamfered on edges and including demolition of existing PCC complete all as specified and directed by Engr-in-Charge.
M&L for Dismantling electrical connections , taking down existing cooling tower motor and fan assembly of following capacity including corroded base frame and carrying out the repairs cleaning of cooling tower, replacement of rusted nut & bolts and preparation of old surface of cooling tower, cooling tower fan, cooling tower motor and applying one coat of synthetic enamel paint inside and outside of cooling tower after repairs refixing back its original position complete all as specified.
110 TR Capacity hub with 4 blades
50 TR capacity hub with 3/4 blades
40 TR capacity hub with 3/4 blades
M&L for Dismantling electrical connections, taking down existing blower motor and PVC fan assembly of following capacity including corroded/damaged base frame and carrying out the repairs cleaning of outdoor unit blower, replacement of rusted / damaged nut & bolts and preparation of old surface of outdoor blower, blower motor and applying one coat of synthetic enamel paint inside and outside of blower unit after repairs refixing back its original position complete all as specified.
40 TR capacity hub with 2/3/4/6/8 blades
20/25 TR capacity hub with 3/4/6/8 blades
Taking down the defective water sprinkler assembly consisting of water distribution pipe set of 4 Nos, sprikler unit, balancing tie rod set etc., and S&F new sprinkler unit made out of diecast aluminium, 1 No. water distribution pipe of HDPE 4 Nos including necessary dripping holes end dummy and 4 Nos tie rod with necessary clamps including testing and commissioning the sprinkler assembly for the following caqpacities of FRP cooling tower of induced draught type complete all as directed by Engr-in-Charge.
110 TR Capacity cooling tower sprinkler
50 TR capacity cooling tower sprinkler
Taking down existing swing type PUF door and including supply and replacement of rubber gasket, PAD lock system, digital temperature indicator, hinges, necessary bolts, nuts etc, refix the door in same location after completion of repairs for cold / cool room complete all as specified and directed by Engineer-in-Charge.
Material & Labour for calibration of complete control wiring for Auto tripping of AC plant & chiller systems including replacement of burnt copper wires, connectors, fuses, indication lamps, push button switches etc complete all as specified and directed by Engineer-in-charge..
Supply and replacement of fiberglass reinforced polyester (FRP) multi cell common basin for 110 TR capacity cooling tower with hot dipped galvanized steel for supports, water outlet connections, overflow and makeup water connections ete., including necessary dismantlintling old unserviceable, complete all as specified and directed by Engineer-in-Charge. Make:- Mihir / Paharpur / Polo/Delta
Supply and replacement of fiberglass reinforced polyester (FRP) casing, fan deck and fan stack, motor cover, inspection door, PVC louvers, hot dipped galvanized steel for supports, corner posts, ladder, water Inlet connections etc for 110 TR capacity, complete all as specified and directed by Engineer-in-Charge. Make:- Mihir / Paharpur / Polo /Delta
Supply and replacement of PVC fill's of PVC (max. temperature 50 degree C), PVC draft eliminators, header assembly, PVC PP Nozzles for 40 to 110 TR capacity complete all as specified and directed by Engineer-in-Charge.
Supply & replacement of Air relief valve for chiller/condenserpipe lines including necessary required etc.,complete all as specified and directed by Engr-in-Charge..
Supply & replacement of 230V PCB drive unit for 110 TR capacity chiller unit for Model No. of EGWFXR 1201MLB2 of Make. Voltas including electrical connections, testing & commissiong etc., complete all as specified & directed by Engr-in-Charge.
Supply & replacement of Display Control touch Board of 110 TR capacity chiller unit for Model No. of EGWFXR 1201MLB2 of Make. Voltas including testing & commissiong etc.,as per existing one complete all as specified & directed by Engr-in-Charge.
ANAND ENTERPRISES AND ENGINEERS
M/S SRI VENKATA BHAVANI CONSTRUCTIONS
GS ENGINEERS
SRIESWARI ENTERPRISES
Chitturi Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .