Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.2 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | 1 | Accepted-AOC AOC | |
| 2 | 2₹34.2 L+₹1.3 L (3.84%)Rejected-AOC BLOCK NO 11 VIMLNATH APARTMENT PRATAP VILAS ROAD NEAR SATYA SAI SCHOOL JAMNAGAR GUJARAT 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | 2 | Rejected-AOC NOT ACCEPTED | |
| 3 | 3₹35.9 L+₹3.0 L (9.07%)Rejected-AOC | 3 | Rejected-AOC NOT ACCEPTED |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(ARMY) BHUJ
GE(ARMY) BHUJ
COMPREHENSIVE MAINTAINENCE OF CERTAIN BR/EM WORKS AT KS LINE - II UNDER AOROF AGE BR II OF GE(A) BHUJ AT MIL STN BHUJ
2023_MES_617684_1
8155
Open Tender
Civil Works
Item Rate
180 days
ARMY AREA BHUJ
REFER TENDER
6 documents required · 6 mandatory
₹500
GE(ARMY) BHUJ
₹70,000
Yes
7 Oct 2023
7 Sept 2023
6 Oct 2023
7 Sept 2023
5 Oct 2023
23 Sept 2023
Amount
M&L for special treatment of sunken portion of WCs and Bath room as per following stages: Stage 1 :- Demolition of WC including lime concrete and cement concrete coba etc and preparing the surfaces of existing sunken portion of WCs or bath etc with wire brush to remove all loose dirt, oil grease etc . Stage 2:- Providing 10mm thick plaster in CM 1:3 with chemical of Dr. Fixit Pidicrete URP or plaster seal of STP Ltd Stage 3:- Applying Dr Fixit Primseal primer or STP Ltd (and allow to dry for 8 hours) under touch dry condition Stage 4:- Applying two coats of water proofing decorative elastomeric coating system of Dr Fixit Raincoats with DFT 100 Micron or shalicry 215 of STP(The surface after painting one coats shall be allowed to dry of 6 hours before next coats) all as per manufacturer instruction Stage 5:- Making holes in wall and fixing 600mm long 40mm dia GI spout for draining the surplus water if any.
M&L Plain cement concrete 1:4:8 type D-2 as in mass filling in sunken portion.
Dismantling 100 mm cast iron /PVC SWR drain pipes, jointed in cement mortar and taking out of trenches, if required (incuding fitting & fixtures)
Ditto above but 75 mm dia pipe.
S&F in repair PVC (SWR) gully trap 110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid in tranches complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid in tranches complete all as specified and directed
S&F in repair 110 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid on wall complete all as specified and directed
S&F in repair 75 mm bore PVC (SWR) pipes Type B ISI marked single socketed in any length with rubber ring joints laid on wall fixed complete all as specified and directed
S&F in repair PVC (SWR) bends, 110 mm bore, any radius complete all as specified and directed.
S&F in repair PVC (SWR) bends, 75 mm bore, any radius complete all as specified and directed.
S&F in repair PVC (SWR) bends, 110 mm bore, any radius with access door complete all as specified and directed.
S&F in repair PVC (SWR) bends, 75 mm bore, any radius with access door complete all as specified and directed.
S&F in repair PVC (SWR) Junction, single, (single T) equal or unequal, 110 mm bore, with access door complete all as specified and directed.
S&F in repair for PVC (SWR) vent cowl, 110 mm bore complete all as specified and directed.
S&F in repair PVC (SWR) 75mm branch piece, single (single Y) equal or unequal with access door complete all as specified and directed.
S&F in repair PVC (SWR) 75mm branch piece, double (double Y) equal or unequal with access door complete all as specified and directed.
S&F in repair vitreous china squatting pan, Orissa pattern, size 580 x 440 mm white with integral foot rests and connection with cast iron P trap and to flushing pipe, anti syphonage pipe etc (excluding flushing cistern and flush pipe) complete with provision of lime concrete bedding including taking down/ Dismantling existing unserviceable WC of any description and in any position & fixing new WC in repair and making good the disturbed surfaces to match with existing surfaces complete all as specified and directed.
S & F in repair vitreous china wash basin, white flat back , size 550mmx450mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated fancy type pillar tap 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed.
S & F in repair vitreous china wash basin, white flat back , size 450mmx300mm with and including Waste fittings, brass, chromium plated for basins with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed with and including Supplying and fixing cast copper alloy chromium plated, fancy type, pillar tap, 15mm bore, screwed down high pressure with or without lettered hot or cold with long shanks, screwed for iron pipe complete all as specified and directed.
S&F in repair PVC valve-less, syphonic action type, flushing cistern, low level, 10 litre capacity (ISI marked) white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
S&F Stop valves, cast copper alloy, ISI marked ,screwed down high pressure with crutch of butter fly handle, fancy type , chromium plated, with long shank and cup, screwed both ends for iron pipes or for union , for 15 mm bore , complete all as specified and directed.
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 15mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 20mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Taking up or down existing unserviceable upvc/ mild steel water tubing and connections 25mm dia, any grade, of any description or in any position including fittings complete all as specified and directed
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth
Supplying and Laying 16mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supplying and Laying 20mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
Supplying and Laying 25mm outer dia of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed
S&F bib tap, cast copper alloy chromium plated, screwed down high pressure with crutch of butter fly handle fancy type CP for 15 mm bore dia complete all as specified and directed.
S&F for Swivel shower rose size 125 mm of PTMT , any colour , for fixing with 15 mm dia pipe ,( minimum weight 40 gm. ) with and including Shower arm 15 mm size, 195 mm long with bend of 45 degree with flange of PTMT any colour (Min wt. 40gms) , fixed in repairs , complete all as specified and directed .
S&F PVC connections 15 mm size with PTMT nuts of length 450 mm
S/F in repair 75 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement
S&F in repair vitreous china Wash down water closet (pedestal pattern), complete including Pedestal pan and trap and seat cover, including connection to drain ( or outgoing pipe) and flushing pipe, antisyphonage pipes etc (excluding flushing cistern and flush pipe) complete
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises all as directed
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles, over and including 15 mm thick screed bed or bedding layer of cement mortar (1:6) complete all as specified and directed.
M&L for glazed ceramic tiles, coloured tiles, 450X300 x 7mm thick on vertical faces i.e.. as in skirting/dado etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles fix over and including 10 mm thick backing coat in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster of any description and in any position of brick or stone wall/concrete surfaces on walls ,ceiling etc including raking out joints ,hacking for key scrubbing down with water etc & prepared to receive new plaster complete all as specified and directed
M&L rendering 15 mm thick in CM 1:6 on brick/concrete wall surfaces of any description, and finishing the surfaces even and smooth without using extra cement complete all as specified and directed .
M&L for 15mm thick rendering on fair faces of brick/concrete surfaces in CM 1:4 finished even and smooth without using extra cement mixed with water proofing compound (Note :- WPC shall be measured & paid separately)
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces with smart painting tools complete all as specified and directed.
M&L for Preparation of old surfaces by complete removal of existing treatment and applying two coats of oil bound distemper over one coat of primer on walls complete all as specified and directed
M&L for preparation of the newly plastered surfaces of walls & applying two coats distemper oil- emulsion , white or tinted over a coat of primer surfaces of wall complete all as specified and directed.
M&L for rendering 5 mm thick in Cement Mortar (1:3) on ceiling finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of the newly plastered surfaces of ceiling & applying 3 coats of white wash on ceiling surfaces complete all as specified and directed.
Providing & applying Rising damp-proof coating system with Single component ready to use damp-proof coating Roff Hydamp : 1.SURFACE PREPARATION: Thoroughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc. All large voids or hollow portions must be removed and re-plastered. Non- moving cracks having width upto 5 mm must be filled with Polymer based crack filler. 2 APPLICATION: Apply the first coat of Dr Fixit Dampguard Classic with a paintbrush directly on the prepared surfaces by mixing ( 1 part base:1 part hardner: 1 part of water) . Allow to dry for a minimum 2-3 hrs. Apply one part of DAMPGUARD mixed chemical and 2 parts of OPC white cement/Birla Putty and make the Putty, apply Putty on the entire surface area. Allow it to dry for at least 3-4 hours. Apply the Final coat of Dr Fixit Dampguard Classic on the entire surface and allow the surface to air cure 48 Hrs proceeds to paint.
M&L in repair for preparing the existing surface by cleaning thoroughly to make it smooth and free from any foreign matter such as fungus, moss, dust etc by wire brushing and dusting and applying a coat of bitumenous primer conforming to IS : 3384 - 1986 @ 0.30 litre / Sqm and then pressing & laying 3mm thick Atactic Polypropylene Polymer (APP) modified prefabricated with non woven polyester reinforcement five layer water proofing membrane weighing not less than 3.50 Kg/ Sqm comprising of centre core of 160 - 170gsm non - woven polyster matt sandwitched on both sides by APP polymer modified bitumen duly protected on both sides by 20 micron HMHDPE film by torch on application with gas welding torch (Butane torch), and thereover applying a tack coat of 85/25 blown grade bitumen conforming to IS : 702 @ 1.20 Kg / Sqm incl cleaning surface and applying two coats of aluminium paint on roof or vertical surfaces and complete all as specified. as per manufacturer's instructions and as directed. Note :- The WPT work shall be got done through manufacturer's authorised applicator only under strict supervision of manufacturer's technical representative.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs of RCC roof and histing if required reconnecting and re-fixing in position with replacement of nipple/union/socket check nut of capacity exc 500Ltrs n.exc 1000Ltrs incl cleaning & removing of all scab & dirt etc from tank & from mouths of circulating pipes etc complete all as directed
Cutting chase in brick walls, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealing APP membrane etc and making good, cutting not exc 10cm girth complete all as specified and as directed
M&L for brushing neat cement slurry with 3 Kg/Sqm of cement complete all as specified and directed.
M&L Rendering 10 mm thick of CM 1:4 on concrete roof surfaces is to be finished even and smooth without using extra cement with mixing water proofing compound @3% by weight. complete all as directed.
Supply only water proofing compound (ISI Mark) complete all as specified and directed.
Taking down existing chowkats or frames of any description and in any position from the opening of size not exceeding 1.50 sqm each with shutter i.e. without taking off shutter from the frames complete all as specified and directed.
Taking down shutters of any description and in any position of size exceeding 1 sqm but not exceeding 2 sqm each complete all as specified and directed.
S&F aluminium anodised ventilator with fixed aluminium frame of size 65 x 40 x 1.98mm thick fixed in vertical position with aluminium vertical members and half portion to be provided with 4mm thick pin head glass and remaining portion to be louvered using 3mm thick pin head glass and louvered portion covered with stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm incl necessary channel frame work, including rubber gasket and aluminium beading complete all as specified.
S & F 3mm thick figured glass ,pin head type and glazing with oil putty in square n.exc 0.5 Sqm in each pane etc all as specified.
S & F Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average with of aperture 1.40mm (weight not less than 600 gms /sqm )and fixed with aluminium wire staples/iron and wooden beads etc complete all as specified and directed.
Hacking out old broken glass (any thickness size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clip and providing and fixing new ones complete all as specified and directed.
S&F sheet glass 3 mm thick ordinary quality and glazing with oil putty or wooden beads in square, rectangle n.exc 0.5 Sqm in each pan all as specified and as directed.
S&F in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or stainless steel wire staple complete all as specified and directed.
M&L Cement concrete ( 1:3:6) type C- 2, using (40mm graded stone aggregate) 75 mm thick as in sub base /plinth protection etc. Finishing cement concrete surface even and smooth without using extra cement complete all as directed.
M & L in repair for Curtain rod, stainless steel of 25mm dia pipe decorative finish with and including supply and fixing stainless steel decorated type brackets, stops, rollers etc. fixed on walls with brass screws with PVC rawl plugs as in curtain rods complete all as specified and directed.
S&F in repair Rotational moulded polyethylene water storage tanks 1000 Litres Capacity ( Cylindrical vertical with closed top hoisted and fixed in position all as specified in SSR Part-I
S&F SS 1st grade Kitchen Plate rack over all size (36x48x10 in inches) conforming to Jainko Cat part No. KRJ-9
Dismantaling and taking down copper / aluminium point wiring any type / size complete with removing all connection and accessories such as switches , sockets, ceiling rose,pendent holder,fan regulator any type , all type of fitting , batten , steel or PVC conduit , casing caping etc compele and making good the disturbed surface.
Taking down old and unserviceable sub main wiring any size / type / core incl earth wire complete with batten/conduit etc and making good the disturbed surface to match the existing disturbed surface all as directed by Engr-in-charg.
Taking down old and unsrevicable sheet metal enclosure , switch fuse unit , distribution bord any type /way / capacity including fuses,MCB's , insulator etc complete after removing all connection and making good the disturbed surface all as directed by Engr-in-charg.
M&L for point wiring with using 1.5 Sqmm (nominal area) multi standard copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade with and including PVC conduit pipe of adequate size concealed on wall / fixed to surface on ceiling with PVC rawl plugs with modular sunken type pressed steel terminal box and junction boxes 1.6mm thick of suitable size, duly painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for following:- NOTE :- (i) Quoted rate shall be deemed to include the cost of cutting chases in walls / pillars /column etc. of any description for concealing the boxes,conduit pipe to required depth & making good the disturbed surface in CM 1:4 including finishing the surface to match with the existing surface. (ii) Fittings like switches, sockets, regulators, lamp holders, light fittings shall be measured and paid for separately under appropriate item of Schedule `A'. (iii) The quoted rates shall be deemed to be inclusive for provision of covering modular sunken boards/terminal boxes / junction boxes of any shape and size with modular type white plate with suitable brass screws and cup washers
One light point controlled by one; one way switch.
One fan/exhaust fan point controlled by one, one way switch
One 3 pin socket out let 5 amp (independent) point controlled by one; one way switch.
One 3 pin socket out let 5 amp point on the (same board) with other switches.
All as per item No. 4 here-in-before but with 2.5sq mm size FRLS pvc insulated and unsheathed 1100 volts grade single core stranded (multistrand) copper conductor cable for 3 pin socket outlet 15 amp on independent board.
Supply and fix ceiling rose surface bakelite 63.5 x 20 mm, three terminals, complete all as specified and directed.
Supply and fix modular switch 6 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge.
Supply and fix modular switch 16 Amp, one way, 1 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge.
Supply and fix modular socket, 6 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge
Supply and fix switch socket modular , 6 /16 Amp, 2/3 pin combined, 2 module, 230 volts AC circuit complete all as specified and directed by Engr-in-charge
Supply and fix modular fan regulator 120 W 2 module complete all as specified and directed by Accepting officer
Supply only LED spot (recessed) white light 15 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed
Supply only LED spot (recessed) white light 12 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed
Supply only LED spot (recessed) white light 6 W round type AC 90 - 260 volts including all accessories and fixing arrangement complete all as specified and directed
Supply and fix elegantly industrial general purpose box type luminaire, 1x20 Watt, designed box type LED luminaries, CRCA sheet steel housing with white reflector cover fitted to the body with decorative end covers complete with spring loaded rotor type lamp holders, connected block with and including 01 No LED lamp 20 Watt and all accessories, pre-wired and connecting the same to ceiling rose with & including three core PVC insulated and sheathed copper conductor 23/0.0076 cable including all accessories and fixing arrangement for fixing the light fitting to walls / roof surface over and including 2 Nos PVC square box complete all as specified and directed.
Supply and fixing of mirror light of capacity 1x10 Watt epoxy white powder coated CRCA sheet steel housing with acrylic diffuser gaskat with all fixing acessories complete all as specified and directed.
Supply and fix lamp holder PVC / Polycarbonate type including 10 Watt LED lamp complete all as specified and directed by Engr-in-charge
Supply and fixing LED ceiling lights fitting 600mmx600mm, 36 watt complete with driver box type with driver, complete all as per directed by Engr-in-charge.
M&L for sub main wiring with four runs of 6 Sqmm (4x6 sqmm )1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x6 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 4 runs of 6 Sqmm ,one run of 6 Sqmm ( 4x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit again.
M&L for sub main wiring with two runs of 6 Sqmm (2x6 sqmm )1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductorcable confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in walls/roofs/floors etc with one run of 6 Sqmm (1x64 sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire complete all as specified and directed. Note:- 2 runs of 6 Sqmm ,one run of 6 Sqmm ( 2x6 sqmm + 1x6 sqmm ) cable and one meter of conduit will be measured as one unit again.
Supply & fixing MCB DBs TPN vertical, Double door, with provision of MCCB as incommer , 4 way, flush in wall, including civil work to match the disturbed surface with existing complete all as specified and directed by Engr-in-charge
S&F sheet metal enclosures for distribution board when MCB to be used TPN ( Triple pole and neutral ) 4 way, 415Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 12 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 8 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
S&F MCCB of capacity 100 Amps , 415 Volts, rupturing capacity 16 KA complete.
S&F MCB TP, 63 Amps, 415 Volts, rupturing capacity 10 KA."B" Series complete.
S&F MCB SPN, 63 Amps, 240 Volts, rupturing capacity 10 KA."B" Series complete.
S&F MCB SP, 5 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series complete.
Supply & fix RCBOs double pole 63 A for earth leakage, overload & short- circuit protection 30 mA complete.
M&L , earthing complete for machinary / Equipment installed at power house / sub station with galavanised steel earth plate electrode of size 60 cmx 60 cmx 6 mm thick buried directly in ground ( earth pit not less then 2.25 m deep below the normal ground level ) with top edge of the earth plate not less then 1.5m below normal Ground level connected galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washerws and check nuts all shown in electrical plate No.5 of SSR Part- I connected to main board / disribution board complete .Earthing GI lead and GI protection pipe 15 mm dia light grade upto 7.5 m from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed.
Note :- (i) The unit rate shall also included for earth work in hard /dense soil , PCC type C-I (1:3:6) chamber , PCC 1:2:4 type B-I cover 50 mm thick reinforced with 8 mm dia TMT bars,150 mm c/c both ways, funnel with watering pipe 20 mm dia medium graded , GI protection pipe light grade 15 mm dia and wire mesh complete in addition to items No. 1(a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II.
(ii) Earthing lead and GI protection pipe beyond 7.5 mtrs will be measured and paid separatelly if required under appropriate Schedule.
Note :- (i) Earthing shall be tested as specified in casul 19.137 of SSP PART - I 2009 , to the entire satisfication of Engr-in-Charge. (ii) On teting after complataion of earthing , if the desired earth resistance is not obatined the earthing wiil be re done by the contractor at his on risk and cost to the entire satisfaction of the Engr - in - charge.
Nirmal Construction
suvidhiconstruction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .