| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.6 LAccepted-AOC GEETA COTTAGE NO 03 HOUSE NO 11 OPP CIVIL AIR PORT BHUJ KUTCH 370001 GUJARAT | KACHCHH | GUJARAT | 370001 | ₹15.6 L Quoted ₹16.1 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹17.6 L+₹1.6 L (9.76%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹17.6 L+₹1.6 L (9.76%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹21.2 L+₹5.1 L (32.0%)Rejected-Finance HAVELI FALIYA NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | ₹21.2 L+₹5.1 L (32.0%) | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
2 Apr 2024, 6:00 pmClosed
CWE (AF) BHUJ
CWE (AF) BHUJ KHAVDA ROAD BHUJ KACHCHH PIN 370001
COMREHENSIVE MAINTENANCE AND REPAIRS TO CENTRAL AC PLANT AND CHILLER PLANT/PACKAGE AC CONNECTED ITEMS AT AF STN NALIYA
2024_MES_640332_2
85256/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
NALIYA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) NALIYA
₹30,000
Yes
13 May 2024
12 Mar 2024
4 Apr 2024
12 Mar 2024
2 Apr 2024
19 Mar 2024
Amount
S & F in repair Display controller of 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by Engr-In-Charge.
S & F in repair Air release valve complete assy suitable for 45 KW capacity Hot Water generator of Make- Rapid Cool all as directed by Engr-In-Charge.
S & F in repair V-belts type A-23 model suitable for CSU motors for AC plant Make; Fenner/ Dunlop or equivalent
S & F in repair V-belts type B-62 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent
S & F in repair V-belts type A-44 model suitable for AHU motors for AC plant Make; Fenner/ Dunlop or equivalent
M&L for top up/ gas charging with refrigerant gas (R-410) for dehumidifier after vacuuming and leak testing including brazing suction/ discharge line and testing complete all as specified and as directed by Engr-In-Charge.
S&F in repair rotary/ invt type compressor of split type AC 1.5/2 Ton capacity in position, charging of refrigerant gas of required quantity, brazing of discharge and suction line and leak testing complete all as specified and as directed
S & F in repair capacitor of 35 MFD for dehumidifier all as specified and as directed by Engr-In-Charge.
S & F in repair Blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz all as specified and as directed by Engr-In-Charge.
S & F in repair Fan blade for blower motor of dehumidifier FDNF96, 2 KG,230V, 50Hz all as specified and as directed by Engr-In-Charge.
S & F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-410-W (Gde E-250 quality A) including welding work and black enamel paint with one coat primer all as directed by Engr-In-Charge
M & L for Servicing, greasing and alignment of AHU/CSU motors and pullies installed at AF Stn Naliya complete all as specified and as directed by Engr-In-Charge.
Servicing, cleaning and descaling with the help of diluted Acid of heat exchanger for hot water & cold water installed in CSU (Ceiling suspended unit) of 3TR capacity including minor repair and replacement of rusted parts as nut bolt brazing/welding etc for any leakage observed all as specified and as directed by Engr-In-Charge.
Servicing, descaling and cleaning of Hot Water Generator 45KW capacity 3 pase 440 Volts 50Hz including minor repair of parts as two qty heating coil /nut bolt/packing etc all as specified and as directed by Engr-In-Charge.
S & F in repair to CSU monoblock pump set of capacity 0.25 HP, single phase 230 Volts all as directed by Engr-In-Charge.
S & F in repair of 12V 26 AH maintenance free batteries for power backup of UPS unit all as directed by Engr-In-Charge
S & F in repair of 12V 7 AH maintenance free (SMF) batteries for power backup of UPS unit all as specified and as directed by Engr-In-Charge.
S & F in repair of Spun Filter /Cartridge of RO Plant all as directed by Engr-in- charge.
M&L for Anti scalant suitable for preventing formation of calcium carbonate and calcium sulphate and fouling by silica complete all as specified and as directed by Engr-In-Charge.
S & F in repair of high TDS Membrane of RO Plant of size up to 40/40 all as directed by Engr-In-Charge.
S & F in repair of silica sand from Sand filter for RO plant of any capacity all as specified and as directed by Engr-In-Charge.
S & F in repair of Activated Carbon from carbon filter for RO plant all as specified and as directed by Engr-In-Charge.
Dismantling the components of Reverse Osmosis plant and checking the serviceability of plant including rubber bushes, fittings, low pressure/ high pressure motor pumps & Cleaning of membrane filter with citric acid and cleaning, washing with the help of high pressure water pump complete and re-fixing the same after necessary repairs and replacement of unserviceable parts, commissioning and testing complete all as specified and as directed by Engr-In-Charge. Notes:- Replacement of defective items of existing make/ size shall be measured and paid separately under respective items.
S&F in repair of EWT (Entering water temperature) of 13x3 or 12x3 TR chiller Plant sensor as per existing model complete all as specified and as directed.
S&F in repair LWT(Leaving water Temperature) of 13x3 or 12x3 TR chiller Plantsensor as per existing model complete all as specified and as directed.
M&L for removing of damaged portion of duct insulation and fixing new Nitrile Insulation 13 mm (minium) thick closed cell elastomeric nitrile rubber insulation of 40-60 kg/cum density, on duct surface free from dust etc using a thin film of insulation material all as per manufacturer's recommended adhesive. Both duct and instulation, keeping the insulation material under compression (without any stretching), seal all joints air tight etc complete all as specified and as directed.
S&F in repair 100 mm dia butterfly valve of AC chillier plant circulation pipe line, of existing model, welding the same as per existing fixing arrangements complete all as specified and as directed.
Supply, Installation, testing & commissioning of Humidifier controller for atuomation all as specified and as directed by Engr-In-Charge.
Supply, Installation, testing & commissioning of Heater strip 2/4KW capacity all as specified and as directed by Engr-In-Charge.
S & F Thermostate for humidifier all as specified and as directed by Engr-In-Charge.
S & F in repair of 40 TR capacity Cooling Tower PVC filings along with sprinkler set, tension bar GI material,turn buckle, branch pipe of suitable size(approx 50 mm dia) and FRP eliminator blades for each cooling tower all as specified and as directed by Engr-In-Charge.
S & F in repair to cooling tower blower induction motor of capacity 5 HP/3.7KW, three phase 440 Volts with rewinding of motors with suitable size of super enamelled copper wire including shaft bearing including taking down, transportation to maintenance work shop, refixing all as specified and as directed by Engr-In-Charge.
S&F power contactor 3 pase system for 1.5 HP motor installed at TP-III of Model No-MNXA1 & MXA1 Make-L&T or equivalent including 10 Amps relay & PLA relay of blower motor Motor all as directed by Engr-In-Charge.
S&F power contactor for single phase motor of capacity 0.25 HP installed at TP-III of Model No-LAEN22 Make-Schnieder or equivalent including all as directed by Engr-In-Charge.
M&L for opening of CSU(Ceiling suspended unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02Nos) for repair and refixing complete assembly with new shaft,new pully and bearings (02 Nos) for 3 TR Capacity CSU including testing and greasing complete all as specified and as directed.
M&L for opening of AHU(Air Handling unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02Nos) for repair and refixing complete assembly with new ball bearings (02 Nos) for 25 TR Capacity AHU including testing and greasing complete all as specified and as directed.
M&L for opening of AHU(Air Handling unit) and taking down cover plate, disconnecting electric connections, opening the blower motor, blower, belt, shaft and bearings (02 Nos) for repair and refixing complete assembly with new ball bearings (02 Nos) for 35 TR Capacity AHU including testing and greasing complete all as specified and as directed by Engr-In-Charge.
M & L for FRP coating inside CSU area for arresting any type of water leakage in side CSU all as specified and as directed by Engr-In-Charge.
S & F in repair of cooling tower water inlet float Float valve PVC type all as specified and as directed by Engr-In-Charge.
S & F metal based Float valve for Humidifier of capacity 2KW to 4 KW all as specified and as directed by Engr-In-Charge.
S & F Cooling Tower Fan blade suitable for 40 TR capacity cooling tower all as specified and as directed by Engr-In-Charge.
Repair / servicing of stuck monoblock motor and pump set of 0.25 HP capacity single pase 440 Volts 50Hz lubricate the motor bearings after clean the rust with help of anti scale spray and tight the all nut bolt/packing etc all as specified and as directed by Engr-In-Charge.
S & F in repair to UPS of 600VA,360 Watt capacity of output 230 V, 50 Hz for BMS system all as specified and as directed by Engr-In-Charge.
S & F in repair of HRC Fuse link set of 03 of 400 Amp 3NA3 260-7Y, NH2, 500V~/120ka IS-13703 IEC 269-2 all as specified and as directed by Engr-In-Charge.
Dismantling and taking out monoblock motor of 0.25 HP to 2 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc. complete all as directed by Engr-In-Charge. (Note:- Bearing shall be measured and paid seperately)
S & F bearing of motor DE side
S & F bearing of NDE side
Dismantling and taking out monoblock motor of 3 HP to 7.5 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc. complete all as directed by Engr-In-Charge. (Note:- Bearing shall be measured and paid seperately)
S & F bearing of motor DE side
S & F bearing of NDE side
Dismantling and taking out monoblock motor of 10 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc. complete all as directed by Engr-In-Charge. (Note:- Bearing shall be measured and paid seperately)
S & F bearing of motor DE side
S & F bearing of NDE side
Dismantling and taking out monoblock motor of 20 HP from site for repair,opening and re-assembling, transporting from site to workshop and back after repair including loading, unloading , testing, commissioning etc. and refixing after overhauling with replacement of damaged gasket and nut ,bolts etc. complete all as directed by Engr-In-Charge. (Note:- Bearing shall be measured and paid seperately)
S & F bearing of motor DE side
S & F bearing of NDE side
S & F suitable size of super enamelled copper wire for winding of motors all as directed by Engr-In-Charge
Krishna Engineering
GEE CEE ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .