| 1 | L-1₹5.9 LAccepted-Finance 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L-1 | Accepted-Finance Being L-1 | |
| 2 | L-2₹6.1 L+₹19,865 (3.35%)Rejected-Finance | L-2 | Rejected-Finance Being L-2 | |
| 3 | L-3₹6.6 L+₹68,000 (11.5%)Rejected-Finance | L-3 | Rejected-Finance Being L-3 | |
| 4 | L-4₹6.7 L+₹75,246.93 (12.7%)Rejected-Finance 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | L-4 | Rejected-Finance Being L-4 | |
| 5 | L-5₹7.0 L+₹1.1 L (17.9%)Rejected-Finance | L-5 | Rejected-Finance Being L-5 |
Tender Value
₹8.9 L
EMD Value
₹17,847
Closing Date
17 Sept 2020, 6:00 pmClosed
AGM (E-E)
AAI, Project offices, SVPI Airport, Ahmedabad
As per BOQ
2020_AAI_56378_1
AAI/AH/AGM(E-E)/eNIT-05/20-21
Open Tender
Repair and Maintenance Services
Item Rate
60 days
Ahmedabad Airport
As per NIT
6 documents required · 6 mandatory
₹1,180
Yes
Airports Authority of India
₹17,847
Yes
14 Oct 2020
1 Sept 2020
25 Sept 2020
2 Sept 2020
17 Sept 2020
2 Sept 2020
2 Sept 2020 - 8 Sept 2020
Amount
Servicing of 3 Ph 11KV 630A HT Vaccum Circuit Breaker (VCB) of Areva/CG make and connected CTs & PTs, minor repairing works if any complete as required including checking, testing and submission of test reports as detailed in particular specification and as per OEM recommended standards etc. complete all as required and as specified.
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. a) Instantaneous Differential relay (CAG)
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. b) Trip circuit supervision relay (VAX)
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. c) Tripping relay (VAJ / CGXH1)
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. d) Aux. relay (VAA /B33X3 / (AVANA) EMR 261))
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. e) Micom relay (For HT breaker)
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. f) Overcurrent Relay (CGI 14N)
Servicing, Testing and Calibration of following relays at site as detailed in particular specification and as per OEM recommended standard and submission of calibration report complete all as required and as specified. g) Protection Relay (M2-4) (EAPL)
Servicing of Oil type transformer i/c. checking, blowering, cleaning, tightening, physical inspection, arresting the oil leakages by replacing suitable size gaskets from radiator valve & drain plug, Buchholz relay and other visible leakages followed with testing and submission of Test Report and BDV Report (before & after) etc. complete through OEM or his authorized representative and all as specified in Particular Specification for the following capacity of Voltamp Make transformer. a) 11/0.433 kV, 2000 KVA ONAN Transformer
Servicing of Oil type transformer i/c. checking, blowering, cleaning, tightening, physical inspection, arresting the oil leakages by replacing suitable size gaskets from tap switch and other visible leakages followed with testing and submission of Test Report and BDV Report (before & after) etc. complete through OEM or his authorized representative and all as specified in Particular Specification for the following capacity of Voltamp Make transformer. a) 11/0.433 kV, 2000 KVA ONAN Transformer
Servicing of 11/0.433 KVA different capacities from 1600 KVA to 2500 KVA of Voltamp Make Dry type transformers i/c checking, blowering, cleaning, tightening, physical inspection followed with testing and submission of test reports complete through OEM or his authorized representative and all as specified in Particular Specification for the following capacity of Voltamp Make transformer.
Supply and Installation of PECON make (ER7570) WTI meter for 2000KVA, 11/0.433 kV Voltamp make dry type transformer.
Adarsh electric works
System Protection
Ascent Electrification Engineers
SHREE SAI ELECTRICAL and INSTRUMENTATION
Techno Electricals
SHRI SAI ELECTRICAL
POOJA ELECTRICALS
NS ENGINEERS
Taral Electricals
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .