Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC DOOR NO 4 202 MASJID STREET EPURUPALEM CHIRALA 533166 | CHIRALA | 533166 | L1 | Accepted-AOC Being Lowest tenderer | |
| 2 | L2₹4.4 L+₹10,050 (2.34%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹4.5 L+₹22,020 (5.13%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹4.6 L+₹29,075 (6.77%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹5.0 L+₹68,455 (15.9%)Rejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
19 Jul 2022, 6:00 pmClosed
AGE (I) Suryalanka
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA POST -522 102 SURYALANKA
AS PER BOQ AND TENDER DOCUMENT
2022_MES_526651_3
AGE(I)/SL/8454
Open Tender
Civil Works
Item Rate
240 days
AGE (I) Suryalanka
AS PER BOQ AND TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
AGE (I) SURYALANKA
₹12,000
Yes
23 Jul 2022
22 Jun 2022
21 Jul 2022
22 Jun 2022
19 Jul 2022
29 Jun 2022
Amount
Disconnecting existing water tanks of capacity 500 Ltrs to 1000 Ltrs, setting aside (or lowering if required) for repair, cleaning etc and hoisting if required, reconnecting and re-fixing in position (cleaning, repairing etc measured seperately). complete all as specified and as directed.
Disconnecting existing water tanks of capacity 250 Ltrs to 500 Ltrs, setting aside (or lowering if required) for repair, cleaning etc and hoisting if required, reconnecting and re-fixing in position (cleaning, repairing etc measured seperately) complete all as specified and as directed.
S&F in repairs of 20mm outer diameter of 3-layers PP-R (polypropylene random copolymer) pipes SDR-7.4 (PN16) UV stabilized and antimicrobil fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropyene random fittings, bends, reducers, etc fixed complete to walls, ceilings or in floors etc including taking down old pipes complete all as specified and as directed.
S&F in repairs of 25mm outer diameter of 3-layers PP-R (polypropylene random copolymer) pipes SDR-7.4 (PN16) UV stabilized and antimicrobil fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropyene random fittings, bends, reducers, etc fixed complete to walls, ceilings or in floors etc including taking down old pipes complete all as specified and as directed.
Taking down and removing of existing water proofing treatment of any description completely, taking down of old cement plaster if any or roughening of surfaces and cleaning the top surface of RCC slab with using wire brushes and water to remove all dust and loose particles etc complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar 1:3 on roof/ concrete surfaces with using water proofing compound as per manufacturer's instructions, surface finished even and smooth without using extra cement complete all as specified and as directed. Note: (Supply only of water proofing compound/admixture shall be measured and paid separately).
M&L for water proofing treatment with 4mm thick APP modified membrane weighing not less than 4Kg/Sqm reinforced with non woven polyester matt weighing not less than 160 Gram/Sqm having softening point not less than 140 degree celsius, longitudinal tensile strength not less than 300 N/Sqm, tearing strength of 180 N, laid after applying a coat of Bitumen Emulsion, Primer @ 0.20Kg/Sqm over the thoroughly cleaned surfaces to be water proofed. Membrane shall then be laid with 10Cm side overlaps and 15Cm end laps completely thermo fused by flame torch application as per manufacturer's instructions. Care shall be taken to avoid wrinkles while sticking the membrane on the bitumen surface. A coat of hot blown bitumen 90/15 shall be applied on top of the membrane @ 1.20 Kg/Sqm and finally finished with solar reflective aluminium paint @ 0.10 Kg/Sqm. The water proofing membrane shall be extended upto a height of minimum 30 cm on wall and inserted by cutting groove and filling with bitumen complete all as specified and as directed.
Supply only of liquid waterproofing compound of approved make.
DHANA CONSTRUCTIONS
KR ENTERPRISES
G V N R CONSTRUCTIONS
M/S SIRI BUILDERS
SM CONSTRUCTIONS
Ruchira Associates
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .