Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC D 222 30 FUGRO HOUSE TTC INDUSTRIAL AREA MIDC NERUL NAVI MUMBAI THANE MAHARASHTRA 400706 | THANE | MAHARASHTRA | 400706 | ₹2.3 Cr | L1 | Accepted-AOC L1 |
| 2 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
| 3 | Rejected-Technical | - | - | Rejected-Technical Technically Not Qualified |
Tender Value
Refer Docs
EMD Value
₹4.5 L
Closing Date
29 Jan 2025, 11:00 amClosed
Sub-Unit Head, Highway Design, Highway Vertical
4th Floor, Shikhar, Plot No 1, Sector 29, Gurugram 122001
Special Geotechnical Investigation Works and Studies using Jack Up Platform in the State of West Bengal, India
2025_RITES_222477_1
RITES/RT30000118/GEOTECH/2025
Open Tender
Consultancy
Lump-sum
90 days
Services
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹4.5 L
Yes
11 Mar 2025
2 Jan 2025
30 Jan 2025
2 Jan 2025
29 Jan 2025
3 Jan 2025
3 Jan 2025 - 22 Jan 2025
Amount
Mobilisation & Demobilisation JUB,CPT unit
Carrying out boreholes in all kinds of soil with Mazier sampling. SPT sampling will be carried out in hard/dense soil. The boreholes shall be terminated at 80m below ground level (over land/Onshore).
Carrying out Static Cone Penetration Test (CPTU) up to 80m below river bed (over water/offshore) including shifting & positioning of JUB. Note: If any of the above Cone Penetration Tests encountered refusal before reaching the target depth, drilling will be performed to the refusal depth (upto maximum 3 times), followed by Mazier sampling up to a maximum of 2.00 m (approx.). Cone penetration testing will then be resumed, and this process will be repeated as necessary to achieve the target depth.
Carrying out boreholes in all kinds of soil with Mazier sampling. SPT sampling will be carried out in hard/dense soil. The boreholes shall be terminated at 80m below river bed (Over water/Offshore).
Conducting PMT on land (onshore) BHs.
Conducting PMT in River (offshore) BHs.
Carrying out following laboratory tests
Particle Size Distribution
Atterberg's Limit
Natural Moisture Content
Organic Content
Mica Content
Triaxial Test (UU)
Direct Shear Test
Consolidation Test (one dimensional)
Chemical analysis of sub-soil
Chemical analysis of water sample
Mobilizatuion/demobilization of PS logging equipment and manpower.
Conducting PS Logging testing along with data interpretaion and report. Minimum 2 nos. of P-S Logging shall be done over land (onshore) and 1 no. shall be done over water (offshore) to get an idea across the entire width of the river bed material.
Preperation of Geotechnical Factual Report including borehole logs, cone penetration test data and laboratory test results.
RENUKA CONSULTANTS PVT LTD (BID ID -813417)
VKP GEOTECH (BID ID -812714)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .