| 1 | L1₹19.4 LAccepted-AOC 120 ODHAV VANDANA AIRPORT ROAD BHUJ KUTCH 370 001 | KACHCHH | GUJARAT | 370001 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹19.9 L+₹43,751.30 (2.25%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹22.8 L+₹3.4 L (17.4%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹24.6 L+₹5.2 L (26.5%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹22.6 L
EMD Value
₹45,140
Closing Date
7 Nov 2022, 6:00 pmClosed
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
CONSTRUCTION OF MAINTENANCE SHED IN MTR AND S AND PROVN OF SEWAGE LINE NEAR AIRMEN MESS NO 1 AT AF STN BHUJ
2022_MES_557142_1
8623/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) BHUJ
₹45,140
Yes
13 Dec 2022
11 Oct 2022
9 Nov 2022
11 Oct 2022
7 Nov 2022
25 Oct 2022
17 Oct 2022 - 20 Oct 2022
Amount
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in Soft/ loose soil soil complete all as specified and directed by Engineer-in-Charge.
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removing excavated material soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing Cement concrete type C-2, 1:3:6(using 20mm graded stone aggregate) bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge.
Material & labour for laying SGSW pipe for 300 mm internal dia pipes of grade 'A' laid in trenches and jointed complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing cement concrete 1:3:6,type C2 (using 40mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
Material & labour for providingprecast reinforced cement concrete type B-1, 1:2:4 (using 20mm graded stone aggregate) as in cover slabs for drain set in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material & labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including crancking, bending spiraly for column & hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
Material & labour for mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for Precast cement concrete block masonry with solid blocks exc 10cm in width Type C1 (1:3:6) (using 20mm graded stone aggregates) and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material & labour for providing cement concete type B-1,1:2:4 mix (using 20 mm graded stone aggregates) as in copings including necessary use and waste of form work complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 10mm thick on fair faces of brick work or concrete surfaces ,in cement mortar 1:4 mixed with integral water proofing compound at the rate of minimum @ 3% by weight of cement and as per manufacturer's instructions,finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charged. ( Supply only Water proofing compound shall be measured and paid for separately)
Supply only integral water proofing compound complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing Cement concrete, type D2, (1:2:4), (using 40mm graded stone aggregate) in foundation, sub basees and mass concrete complete all as specified and as directed by Engineer-in-Charge.
Supply & fix mild steel pipe(Tubular) fixed as vertical post including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 as in posts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix steel work as rafters and web in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S. 1161-1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
Supply & fix mild steel plates, plain or chequered, in Fe 410-W (Gde-E- 250) quality-A complete all as specified and directed by Engineer-in-Charge.
Supply & fix mild steel screw bolts 16 to 20 mm dia of neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm long and n exc 10 cm long complete all as specified and directed by Engineer-in-Charge.
Supply & fix pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Supply & fix pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550MPA as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge.
Supply & fix hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts complete all as specified and directed by Engineer-in-Charge.
Supply & fix preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth not otherwise described and appying two coat of synthetic enamel paint over one coat of red oxid primer complete all as specified and directed by Engineer-in-Charge.
surface dressing n.exc 15cm deep and getting in soft/loose soil including site clearance complete all as specified and directed by Engineer-in-Charge.
Material and labour for providing 100 mm thick Cement concrete, type D2, (1:4:8), (using 40mm graded stone aggregate) in sub base/floor complete all as specified and as directed by Engineer-in-Charge.
Material and labour for providing 100 mm thick Cement concrete, type B1, (1:2:4), (using 20mm graded stone aggregate) in as floor complete all as specified and as directed by Engineer-in-Charge.
Material & labour for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Material and labour for 75 mm thick providing cement concrete, type C2, (1:3:6), (using 40mm graded stone aggregate) in and as approach path, hardstanding etc in complete all as specified and as directed by Engineer-in-Charge.
Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ complete all as specified and as directed by Engineer-in-Charge.
Expanded metal, not less than 4.00 Kg per SQM and 25mmx25mm cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel embers complete all as specified and as directed by Engineer-in-Charge.
Supply and Fixing wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 20 W 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Supply & fix double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 8 ways with 200 Amp rated bus bar 240 volts powder coated complete all as specified and directed by Engineer-in-Charge.
Supply & fix double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 Single pole and neutral 4 ways with 200 Amp rated bus bar 240 volts powder coated complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB/Isolator TPN of 415 Volts 63 Amp capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB/Isolator TPN of 415 Volts 40 Amp capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge.
Supply & fix MCB/Isolator SP of 240 Volts 10 Amp capacity, 'C' series, 10 KA in existing DB complete all as specified and directed by Engineer-in-Charge.
Supply & fix Switch Socket Combination 5 in 1, 5/15A, flush type universal complete all as specified and directed by Engineer-in-Charge.
Supply & fix Switch Socket Combination multi purpose 2 in 1, 5 pin 5 Amps, flush type universal complete all as specified and directed by Engineer-in-Charge.
Supply & fix PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed by Engineer-in-Charge.
Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 16 sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
Supply, laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4.0 sq. mm 2.0 core nominal cross section in service connections complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed by Engineer-in-Charge including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply & fix Rigid non-metallic PVC conduit of size 25mm exclusive of boxes (junction /terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix of tubes light grade of 40 mm bore galvanised with all fitting for cable protection trenches/ wall/ on pole including necesarry clamps sets and nut & bolts etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for road cutting for laying cables in GI pipe etc complete all as specified and directed by Engineer-in-Charge. Note:- Laying of cables and GI pipe will be measured separately under respective items.
SOIL ENGINEERS AND CONTRACTOR
MUKUL ENGINEERING
Bhavik Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .