| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹15.6 LAccepted-Finance | 1 | Accepted-Finance L1 | |
| 2 | 2₹23.0 L+₹7.4 L (47.6%)Accepted-Finance | 2 | Accepted-Finance L2 | |
| 3 | 3₹23.8 L+₹8.2 L (52.7%)Accepted-Finance | 3 | Accepted-Finance L3 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
2 Dec 2024, 6:55 pmClosed
Executive Engineer Mechanical and Hospital Div BLA
The Executive Engineer Mechanical and Hospital Division Baramulla
Annual Stage Contract for Routine Maintenance and Breakdown Maintenance of Air Conditioning Units (ACs) of various capacities and VRV System installed at Associated Hospital GMC Baramulla along with Operation for a period of one year (2024-25)
2024_PWDJK_264994_2
MHDB/TS/2024-25/96
Open Tender
Repair and Maintenance Services
Item Rate
365 days
GMC Baramulla
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
Executive Engineer Mechanical and Hospital Div Bla
₹24,000
4 Dec 2024
19 Nov 2024
3 Dec 2024
19 Nov 2024
2 Dec 2024
19 Nov 2024
Amount
Dismantling of split type Hot and Cold, indoor and outdoor unit ACs of various capacities including shifting of the same to safer location and reinstallation of the same after necessary repairs (cost of repairs to be provided separately).
Installation of new split type Hot and Cold, indoor and outdoor unit ACs of various capacities.
Providing & Fitting of Out Door Unit Stand.
Providing & Fitting of In Door Unit Stand.
Wet servicing of split type hot and cold air conditioners of various capacities of different makes by using skilled labours and technicians. The job includes dismantling of indoor unit filters, cleaning and removing of dust and dirt from the outdoor unit by way of spraying suitable chemical agent and then checking all parameters of working, and setting them right as per requirement. The job further includes assembling and reinstalling back all the items demounted from the unit and then testing the performance of the AC unit on load. All tools and tackles required at site shall be arranged by the firm.
Providing and fitting of copper tubing with nitrile rubber insulation of following diameters to hot and cold air conditioning units.
Replacement of damaged compressor after demounting of air conditioners of various capacities and makes as per following details installed at associated hospitals of GMC Baramulla. The job includes dismantling of old damaged compressor by way of disconnecting copper tubes and electric connections and then replacement of the same with new compressor. The job further includes brazing of copper tubes and checking of leakages if any and then refilling the same with R-22/410/32 refrigerant and reassembling the parts and installing the outdoor unit to its existing place of installation and then testing the AC units on load to ensure uninterrupted operation of the unit. OEM recommended (Toshiba / Daikin / Hitachi /L.G/ voltas/ O-general/ Mitsubishi / IFB / Panasonic / Bluestar / godrej / emersion /lloyd) recommended make.
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Providing and filling of refrigerant R-22/410/32 for hot and cold air conditioning units.
Providing and fitting of PCB control card for air conditioner outdoor unit as per following detail. The job includes dismantling of the old damaged card and replacing the same with new one of same specifications and then testing the AC unit on load. Daikin Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Toshiba Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Hitachi Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
LG Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Voltas Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Samsung Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Mitsubishi Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
IFB Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Panasonic Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Godrej Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Providing and fitting of PCB control card for air conditioner indoor unit as per following details. The job includes removing of the old damaged card and replacing the same with new one of same specifications and then testing of AC unit on load. Daikin Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series
Toshiba Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Hitachi Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
LG Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Voltas Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Samsung Recommended Make
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Mitsubishi Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
IFB Recommended Make
2 TR (Non Inverter Series)
1.5 TR (Non- Inverter Series)
2 TR (Inverter Series)
1.5 TR (Inverter Series)
Panasonic Recommended Make
2 TR (Non Inverter Series)
2 TR (Inverter Series)
Godrej Recommended Make
2 TR (Non Inverter Series)
2 TR (Inverter Series)
Providing & fitting of 513 DTC controller with sensor.
Providing and fitting of sub zero controller
Providing and fitting of L.P and H.P switch
Providing and fitting of DC fan motor
Providing & fitting of overload relay as per sample
Providing & fitting of thermostat with control knob
Rewinding of fan motor and refitting and commissioning
Providing & fitting of MFD, of starting capacity 80-100, 275 volts/63 MFD 440 volts
Replacement of overload protector (Relay)
Replacement of overload protector (Relay)
Providing & fitting of running capacitor (63 MFD , 440 volt)
Providing & fitting of toggle switch one way
Providing & fitting of fan blades Aluminum/Plastic
Providing & fitting of toggle switch two way 20 AMP
Providing & fitting of heating element for 1.5 ton AC 2.5 KW with/without fins
Providing & fixing of three pin top 15 Amp with lead 5 mtrs un armoured coil
Providing & fixing of heater thermostat
Providing and fixing of switch knob
Providing & fixing of remote control for split AC (1.5 TR to 2 TR)
Providing & fixing of 30 AMP relay 24 volt
Providing and fixing of anti-dust filters
Providing & fixing of blower
Providing & fixing of 4 way reversing valve
Providing and fixing of IDU fan motor
Providing & fixing of ODU fan motor
Providing and fixing of Horizontal Louvres
Providing and fixing of sensor ODU Ambient
Providing and fixing of sensor IDU Ambient
Providing and fixing of sensor ODU Discharge
Providing and fixing of sensor ODU condenser
Providing and fixing of sensor evaporator IDU
Providing and fixing of service valve 1/4"
Providing and fixing of service valve 1/2"
Providing and fixing of defrost thermo resistor
Providing and fixing of Contactor as per sample
Providing and fixing of Relay
Providing and fixing of phase preventer cum protector
Providing and fixing of capillary tube assembly
Providing and fitting of multi stranded wire pvc insulated single core
Providing and fitting of 32 Ampere DP-MCB
Providing and fitting of 4 kva automatic voltage stabilizer single phase, wall mounted designed at input voltage of 90 volts and output voltage of 220-240 volt with digital display along with the wall mounting brackets and necessary fittings.
Providing and fitting of 5 kva automatic voltage stabilizer single phase, wall mounted designed at input voltage of 90 volts and output voltage of 220-240 volt with digital display along with the wall mounting brackets and necessary fittings.
SITC of 2 Ton split type hot and cold AC with minimum 4 star rating along with 5 Kva Voltage stabilizer, copper piping, electrical wiring, MCB and all other accessories required to make the AC functional should be deemed to have been included in the Job.
SITC of 1.5 Ton split type hot and cold AC with minimum 4 star rating along with 5 Kva Voltage stabilizer, copper piping, electrical wiring, MCB.The job shall include P/F of all allied accessories required to make the AC functional.
Providing and fitting of Galvanized steel protection walkway Tray for VRV copper pipes/ Electrical wires, laid at ground Adjacent to VRV Outdoor units, Size: (2 ft width and 0.5 ft height)
Providing and fitting of copper tubing with nitrile rubber insulation of following diameters to VRV IV system.
Routine maintenance and Breakdown maintenance of indoor unit VRV by way of rewinding of the motor using copper coil of same gauge, including cleaning of hepa filters, radiator and other items/equipments.
Routine maintenance and Breakdown maintenance of indoor unit VRV by way of rewinding of the damaged motor using copper coil of same gauge, including cleaning of hepa filters, radiator and other items/equipments.
Replacement of damaged Compressor of Daikin make VRV-IV (Inverter series), by way of Providing and Fitting of new compressor of following specifications. Outdoor unit Model No : RXYQ18TRY6 (18 HP) High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa.
Replacement of damaged Compressor of Daikin make VRV-IV (Inverter series), by way of Providing and Fitting of new compressor of following specifications. Outdoor unit Model No : RXYQ16TRY6 (16 HP) High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa.
Replacement of damaged Compressor of Daikin make VRV-IV (Inverter series), by way of Providing and Fitting of new compressor of following specifications. Outdoor unit Model No : RXYQ12TRY6 (12 HP) High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa.
Replacement of damaged Compressor of Daikin make VRV-IV (Inverter series), by way of Providing and Fitting of new compressor of following specifications. Outdoor unit Model No : RXYQ8TRY6 (8 HP) High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa.
Wet servicing of 18 HP capacity Daikin VRV IV Inverter series (Both Outdoor & Indoor Units) High pressure side 4.0 MPa Low pressure side 3.3 Mpa capacity by using skilled labourers and technicians. The job includes dismantling of indoor & Outdoor unit filters ,cleaning and removing of dust and dirt from the outdoor unit by way of spraying suitable chemical agent and then checking all parameters of working and setting them right as per requirement. The job further includes assembling and reinstalling back all the items removed from the unit and then testing the performance of the VRV system on load. All tools and tackles required at site shall be arranged by the firm.
Wet servicing of 16 HP capacity Daikin VRV IV Inverter series (Both Outdoor & Indoor Units) High pressure side 4.0 MPa Low pressure side 3.3 Mpa capacity by using skilled labourers and technicians. The job includes dismantling of indoor & Outdoor unit filters, cleaning and removing of dust and dirt from the outdoor unit by way of spraying suitable chemical agent and then checking all parameters of working and setting them right as per requirement. The job further includes assembling and reinstalling back all the items removed from the unit and then testing the performance of the VRV system on load. All tools and tackles required at site shall be arranged by the firm.
Wet servicing of 12 HP capacity Daikin VRV IV Inverter series (Both Outdoor & Indoor Units) High pressure side 4.0 MPa Low pressure side 3.3 Mpa capacity , by using skilled labourers and technicians. The job includes dismantling of indoor & Outdoor unit filters ,cleaning and removing of dust and dirt from the outdoor unit by way of spraying suitable chemical agent and then checking all parameters of working and setting them right as per requirement. The job further includes assembling and reinstalling back all the items removed from the unit and then testing the performance of the VRV system on load. All tools and tackles required at site shall be arranged by firm.
Wet servicing of 8 HP capacity Daikin VRV IV Inverter series (Both Outdoor & Indoor Units) High pressure side 4.0 MPa Low pressure side 3.3 Mpa by using skilled labourers and technicians. The job includes dismantling of indoor & Outdoor unit filters, cleaning and removing of dust and dirt from the outdoor unit by way of spraying suitable chemical agent and then checking all parameters of working and setting them right as per requirement. The job further includes assembling and reinstalling back all the items removed from the unit and then testing the performance of the VRV system on load. All tools and tackles required at site shall be arranged by the firm.
Replacement of damaged Main PCB card by way of Providing and Fitting of new Main PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Main PCB card by way of Providing and Fitting of new Main PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Main PCB card by way of Providing and Fitting of new Main PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Main PCB card by way of Providing and Fitting of new Main PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Inverter PCB card by way of Providing and Fitting of new Inverter PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Inverter PCB card by way of Providing and Fitting of new Inverter PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Inverter PCB card by way of Providing and Fitting of new Inverter PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Inverter PCB card by way of Providing and Fitting of new Inverter PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa, Low pressure side = 3.3 Mpa
Replacement of damaged Noise PCB card by way of Providing and Fitting of new Noise PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa ,Low pressure side = 3.3 Mpa
Replacement of damaged Noise PCB card by way of Providing and Fitting of new Noise PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Noise PCB card by way of Providing and Fitting of new Noise PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Noise PCB card by way of Providing and Fitting of new Noise PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan PCB card by way of Providing and Fitting of new Fan PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan PCB card by way of Providing and Fitting of new Fan PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan PCB card by way of Providing and Fitting of new Fan PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan PCB card by way of Providing and Fitting of new Fan PCB card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan Motor by way of Providing and Fitting of new Fan Motor card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan Motor by way of Providing and Fitting of new Fan Motor card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan Motor by way of Providing and Fitting of new Fan Motor card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Fan Motor by way of Providing and Fitting of new Fan Motor card to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Repairs to 5HP AHU motor by way of extracting the damaged /burnt stator coils from the stator slots by using proper tools and tackles avoiding damage to stator core , followed by complete rewinding of motor in copper wire (insulated) having specific size and gauge. The job shall further include shifting of motor to & fro, refitting and testing at site
Providing and Refilling of Refrigerant R-410 (A) in the complete circuit of the Compressor units of VRV IV Inverter series outdoor units.
Providing and fitting of multi stranded pvc insulated single core copper cable required for indoor and outdoor units of Daikin make VRV-IV system.
Replacement of damaged AHU Control box of existing VRV machines.
Providing and fitting of 16 Ampere box type SS Combine.
Providing and Refilling of Refrigerant R-410/R22/R32 in the complete circuit of the Compressor units of ACs of different capacities and make installed in GMC Baramulla.
Replacement of damaged Four way change over switch by way of Providing and Fitting of new Four way change over switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa , Low pressure side = 3.3 Mpa
Replacement of damaged Four way change over switch by way of Providing and Fitting of new Four way change over switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Four way change over switch by way of Providing and Fitting of new Four way change over switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Four way change over switch by way of Providing and Fitting of new Four way change over switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High Pressure Sensor by way of Providing and Fitting of new High Pressure Sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High Pressure Sensor by way of Providing and Fitting of new High Pressure Sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High Pressure Sensor by way of Providing and Fitting of new High Pressure Sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High Pressure Sensor by way of Providing and Fitting of new High Pressure Sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Solenoid Valve by way of Providing and Fitting of new Solenoid Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Solenoid Valve by way of Providing and Fitting of new Solenoid Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Solenoid Valve by way of Providing and Fitting of new Solenoid Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Solenoid Valve by way of Providing and Fitting of new Solenoid Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Brazing job to copper pipes of different diameters which includes all tools, tackles and accessories required for complete brazing job.
Replacement of damaged Electronic Expansion Valve by way of Providing and Fitting of new Electronic Expansion Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Electronic Expansion Valve by way of Providing and Fitting of new Electronic Expansion Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Electronic Expansion Valve by way of Providing and Fitting of new Electronic Expansion Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged Electronic Expansion Valve by way of Providing and Fitting of new Electronic Expansion Valve to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure sensor by way of Providing and Fitting of new low pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure sensor by way of Providing and Fitting of new low pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure sensor by way of Providing and Fitting of new low pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure sensor by way of Providing and Fitting of new low pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High pressure sensor by way of Providing and Fitting of new High pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High pressure sensor by way of Providing and Fitting of new High pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High pressure sensor by way of Providing and Fitting of new High pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged High pressure sensor by way of Providing and Fitting of new High pressure sensor to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure switch by way of Providing and Fitting of new low pressure switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ18TRY6 (18HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure switch by way of Providing and Fitting of new low pressure switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ16TRY6 (16HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure switch by way of Providing and Fitting of new low pressure switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ12TRY6 (12 HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Replacement of damaged low pressure switch by way of Providing and Fitting of new low pressure switch to VRV IV Inverter series of following specifications. Outdoor unit Model no = RXYQ8TRY6 (8HP) Source = 3-phase, 380-440V , 50Hz High pressure side = 4.0 MPa Low pressure side = 3.3 Mpa
Providing and fitting of deicer thermistor to VRV IV Inverter series Outdoor unit
Providing and fitting of Accumulator inlet thermister to VRV IV Inverter series Outdoor unit
Providing and fitting of thermistor for sub-cooling heat exchanger gas pipe to VRV IV Inverter series Outdoor unit
Providing and fitting of outdoor air thermistor to VRV IV Inverter series Outdoor unit
Providing and fitting of thermistor for discharge pipe to VRV IV Inverter series Outdoor unit
Providing and fitting of thermistor for subcooling heat exchanger liquid pipe to VRV IV Inverter series Outdoor unit
Providing and fitting of thermistor for heat exchanger liquid pipe to VRV IV Inverter series Outdoor unit
Providing and fitting of thermistor for temperature measurement of compressor casing VRV IV Inverter series Outdoor unit.
Operation
Engagement of Semi-skilled manpower (02Nos) for round the clock operation and maintenance of AC’s & VRV system for complete one year 2024-25(@15000/Operator/month)
FARUKH SONS ENTERPRISE (BID ID -2256077)
Elevate Engineers (BID ID -2267861)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .