SR. MANAGER ELECTRICAL
O/O. ENGINEERING ELECTRICAL, VIJAYAWADA AIRPORT, VIJAYAWADA - 521 102
Beautification of approach road to new terminal building with landscaping, hardscaping, horticulture and sculpture works and associated lighting works at Vijayawada International Airport. SH ELECTRICAL WORKS
2026_AAI_288828_1
Beautification of Approach road to NITB with landscaping hardscaping. SH Electrical Works
Open Tender
Electrical Works
Works
90 days
AAI, VIJAYAWADA AIRPORT
As per NIT criteria
12 documents required · 12 mandatory
₹1,180
₹3.9 L
26 Aug 2026
26 Aug 2026
7 Sept 2026
26 Aug 2026
5 Sept 2026
31 Aug 2026
26 Aug 2026 - 27 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of minimum 150W surface mounted LED Flood projector with delivered Luminous flux of minimum 80lm/W. FIxture should have body in diecast aluminium/extrusion and glass sealed optical chamber. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 3000K and CRI > 70 and IK10 with IEC 60598 certification. The luminaire shall meet IP66 with THD < 10% and PF > 0.9. Operating Voltage 140-270VAC,The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 , Quality Standard ISO 9001, Environmental Standard ISO 14001, Luminaire shall have dual optics with primary optics distribution of 120 degree or higher and secondary optics as per site/boq requirement. All the luminaires shall have LM-79 , the testing facility to generate the LM-79 should be at vendor (Not Sub Vendor) address during production and LM-80 of LED shoulde be available. Radiation Emission Measurement as per CISPR.15:2018, Conducted Emission Measurement as per CISPR.15:2018, Output voltage ripple should be within 3%, Full Load Efficiency of the driver ≥ 85%. The total power consumption should not exceed 250W (including driver). Luminaires and driver both shall be BIS certified individually. Heat sink used should be extruded Aluminum or Pressure Die-Cast Aluminum having high conductivity preferably ADC 12 or LM6. An extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the cover and the metal housing to exclude the entry of dust, water, insects, etc. Luminaire should conform to degree of protection of IP 65 or above. Mini IP68 water proof Gel box connector with PP Glue to be provided. Fixture should have beam distribution of 60° , 90° , 120° or as per consultant. Fixture should be compatible with accessory like Baffle as well as snoot for minimum glare.T he product shall be complete with all factory-fitted accessories, mounting hardware, weatherproof cable entries and connectors required for proper installation including suitable foundation and operation. The manufacturers name/logo should be engraved/embossed on the housing/body or Name/Logo on aluminum plate labels or Name/logo printed on housing/body etc. complete as required and as approved by Engineer In Charge.
Location: SCULPTURE / STATUE | 60 | Each | - | - |
| 2 | SITC of minimum 15W( Lamp Degree 24⁰ ) surface mounted LED spot projector with delivered Luminous flux of minimum 35 lm/W. FIxture should have body in die-cast aluminium/extrusion and glass sealed optical chamber. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of RGBW and CRI > 70 and IK10 with IEC 60598 certification. The luminaire shall meet IP66 with THD < 10% and PF > 0.9. Operating Voltage 140-270VAC,The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 , Quality Standard ISO 9001, Environmental Standard ISO 14001, Luminaire shall have dual optics with primary optics distribution of 120 degree or higher and secondary optics as per site/boq requirement. All the luminaires shall have LM-79 , the testing facility to generate the LM-79 should be at vendor (Not Sub Vendor) address during production and LM-80 of LED shoulde be available. Radiation Emission Measurement as per CISPR.15:2018, Conducted Emission Measurement as per CISPR.15:2018, Output voltage ripple should be within 3%, Full Load Efficiency of the driver ≥ 85%. Luminaires and driver both shall be BIS certified individually. Heat sink used should be extruded Aluminum or Pressure Die-Cast Aluminum having high conductivity preferably ADC 12 or LM6. An extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the cover and the metal housing to exclude the entry of dust, water, insects, etc. Luminaire should conform to degree of protection of IP 65 or above. Mini IP68 water proof Gel box connector with PP Glue to be provided. Fixture should have beam distribution of 10° , 24° , 36°, 48° , 10X40° , 10X25° & 100X10° or as per consultant. Fixture should be compatible with accessory like honeycomb louvre as well as snoot for minimum glare. The product shall be complete with all factory-fitted accessories, mounting hardware, weatherproof cable entries and connectors required for proper installation including suitable foundation and operation. The manufacturers name/logo should be engraved/embossed on the housing/body or Name/Logo on aluminum plate labels or Name/logo printed on housing/body including jumper cable 5pin, 200W DC24V IP67 Driver, etc. complete as required and as approved by Engineer In Charge.
Location: PILLAR | 60 | Each | - | - |
| 3 | SITC of minimum 15W ( Lamp degree 36⁰ )surface mounted LED spot projector with delivered Luminous flux of minimum 35 lm/W. FIxture should have body in die-cast aluminium/extrusion and glass sealed optical chamber. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of RGBW and CRI > 70 and IK10 with IEC 60598 certification. The luminaire shall meet IP66 with THD < 10% and PF > 0.9. Operating Voltage 140-270VAC,The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 , Quality Standard ISO 9001, Environmental Standard ISO 14001, Luminaire shall have dual optics with primary optics distribution of 120 degree or higher and secondary optics as per site/boq requirement. All the luminaires shall have LM-79 , the testing facility to generate the LM-79 should be at vendor (Not Sub Vendor) address during production and LM-80 of LED shoulde be available. Radiation Emission Measurement as per CISPR.15:2018, Conducted Emission Measurement as per CISPR.15:2018, Output voltage ripple should be within 3%, Full Load Efficiency of the driver ≥ 85%. Luminaires and driver both shall be BIS certified individually. Heat sink used should be extruded Aluminum or Pressure Die-Cast Aluminum having high conductivity preferably ADC 12 or LM6. An extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the cover and the metal housing to exclude the entry of dust, water, insects, etc. Luminaire should conform to degree of protection of IP 65 or above. Mini IP68 water proof Gel box connector with PP Glue to be provided. Fixture should have beam distribution of 10° , 24° , 36°, 48° , 10X40° , 10X25° & 100X10° or as per consultant. Fixture should be compatible with accessory like honeycomb louvre as well as snoot for minimum glare. The product shall be complete with all factory-fitted accessories, mounting hardware, weatherproof cable entries and connectors required for proper installation including suitable foundation and operation. The manufacturers name/logo should be engraved/embossed on the housing/body or Name/Logo on aluminum plate labels or Name/logo printed on housing/body including jumper cable 5pin, 200W DC24V IP67 Driver, etc. complete as required and as approved by Engineer In Charge.
Location: TREES &PLANTERS | 300 | Each | - | - |
| 4 | SITC of minimum 5Wm,3000K color, 24V flexible LED homogenous fixture for exterior top crown structure wash application. The housing of the material should be made of PCB Silicon Tube and the LEDs should be SMD type (SDCM <5). The delivered lumen output of the fixture should be around 40lm/W. The protection rating of the fixture should be IP67. Output power of the fixture should be 10-20W/M. The fixture should be of beam distribution of minimum 115˚. CCT of the fixture should be RGBW or as per requirement of the architect. The colour rendering capability of the fixture should be more the 80. The products shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors,suitable LED drivers etc. Fixture should come with rigid Installation Aluminium profile for flex & Difusser as per site requirement etc. complete as required and as approved by Engineer In Charge.
Location: CAB PICKUP AREA PLANTER EDGE | 500 | Mtr | - | - |
| 5 | SITC of minimum 15W surface mounted LED Bollard fixture with delivered Luminous flux of minimum 60lm/W. FIxture should have body in die-cast aluminium/extrusion and glass sealed optical chamber. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 3000k and CRI > 70 and IK10 with IEC 60598 certification. The luminaire shall meet IP66 with THD < 10% and PF > 0.9. Operating Voltage 140-240VAC,The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 , Quality Standard ISO 9001, Environmental Standard ISO 14001, Luminaire shall have dual optics with primary optics distribution of 120degree or higher and secondary optics as per site/boq requirement. All the luminaires shall have LM-79 , the testing facility to generate the LM-79 should be at vendor (Not Sub Vendor) address during production and LM-80 of LED shoulde be available. Radiation Emission Measurement as per CISPR.15:2018, Conducted Emission Measurement as per CISPR.15:2018, Output voltage ripple should be within 3%, Full Load Efficiency of the driver ≥ 85%. The total power consumption should not exceed 20W (including driver). Luminaires and driver both shall be BIS certified individually. Heat sink used should be extruded Aluminum or Pressure Die-Cast Aluminum having high conductivity preferably ADC 12 or LM6. An extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the cover and the metal housing to exclude the entry of dust, water, insects, etc. Luminaire should conform to degree of protection of IP 65 or above. Mini 1P68 water proof Gel box connector with PP Glue to be provided. Fixture should have beam distribution of 60° , 120° , 180°, 360° , or as per consultant. The product shall be complete with all factory-fitted accessories, mounting hardware, weatherproof cable entries and connectors required for proper installation including suitable foundation and operation. Fixture dimension should be 750mmHeight and 150mm Dia as per fixture wattage. The manufacturers name/logo should be engraved/embossed on the housing/body or Name/Logo on aluminum plate labels or Name/logo printed on housing/body etc. complete as required and as approved by Engineer In Charge.
Location: LANDSCAPE PATHWAY | 150 | Each | - | - |
| 6 | SITC of minimum 60W surface mounted LED POST TOP POLE LIGHT fixture with delivered Luminous flux of minimum 80lm/W. FIxture should have body in die-cast aluminium/extrusion and glass sealed optical chamber. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a colour temperature of 3000k and CRI > 70 and IK10 with IEC 60598 certification. The luminaire shall meet IP66 with THD < 10% and PF > 0.9. Operating Voltage 140-270VAC,The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 , Quality Standard ISO 9001, Environmental Standard ISO 14001, Luminaire shall have dual optics with primary optics distribution of 120degree or higher and secondary optics as per site/boq requirement. All the luminaires shall have LM-79 , the testing facility to generate the LM-79 should be at vendor (Not Sub Vendor) address during production and LM-80 of LED shoulde be available. Radiation Emission Measurement as per CISPR.15:2018, Conducted Emission Measurement as per CISPR.15:2018, Output voltage ripple should be within 3%, Full Load Efficiency of the driver ≥ 85%. The total power consumption should not exceed 20W (including driver). Luminaires and driver both shall be BIS certified individually. Heat sink used should be extruded Aluminum or Pressure Die-Cast Aluminum having high conductivity preferably ADC 12 or LM6. An extruded silicon loop gasket shall be provided in the lantern body to ensure a weather proof seal between the cover and the metal housing to exclude the entry of dust, water, insects, etc. Luminaire should conform to degree of protection of IP 65 or above. Mini IP68 water proof Gel box connector with PP Glue to be provided. Fixture should have beam distribution of 60° , 120° , 180°, 360° , or as per consultant.The product shall be complete with all factory-fitted accessories, mounting hardware, weatherproof cable entries and connectors required for proper installation including suitable foundation and operation. Fixture dimension should be 2100mm Height / 2400mm Height as per fixture wattage. The manufacturers name/logo should be engraved/embossed on the housing/body or Name/Logo on aluminum plate labels or Name/logo printed on housing/body etc. complete as required and as approved by Engineer In Charge.
Location: LANDSCAPE PATHWAY | 100 | Each | - | - |
| 7 | Supply of following sizes of 1.1 KV grade multicore copper conductor PVC insulated / XLPE insulated and PVC sheathed armoured cable as per IS-7098 (Part-I) 1988 respectively with upto date ammendments.
4C X 10 Sq mm | 4,700 | Mtr | - | - |
| 8 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in existing RCC/HUME/METAL/DWC HDPE pipe etc as required.
Upto 35 sq. mm | 4,300 | Mtr | - | - |
| 9 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in masonnary open duct etc as required.
Upto 35 sq. mm | 200 | Mtr | - | - |
| 10 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
Upto 35 sq. mm ( clamped with 1mm thick saddle) | 200 | Mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
TENDERDOCLANDSCAPE.pdf
Tender Documents • 10.76 MB
BOQ_337091.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].