Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.4 LAccepted-AOC B 39 UPPER GROUND FATEH NAGAR NEW DELHI 110018 | WEST | DELHI | 110018 | L1 | Accepted-AOC L1 AND ACCEPATABLE | |
| 2 | L2₹36.2 L+₹1.8 L (5.12%)Rejected-AOC 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | L2 | Rejected-AOC NOT L1 |
Tender Value
₹30.0 L
EMD Value
₹60,000
Closing Date
4 Sept 2024, 12:00 pmClosed
CWE AHMEDABAD
CWE AHMEDABAD
REPAIR/ REPLACEMENT OF HT OVERHEAD LINES, TRANSFORMER, HT UG CABLES, SWITCH GEARS AND ALLIED WORKS UNDER AOR OF AGE E/M OF GE (A) BHUJ AT MIL STN BHUJ AND KHAVDA
2024_MES_664065_1
87276/E8
Open Tender
Civil Works
Item Rate
120 days
ARMY AREA BHUJ
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (A) BHUJ
₹60,000
Yes
1 Jan 2025
5 Jul 2024
5 Sept 2024
5 Jul 2024
4 Sept 2024
19 Jul 2024
Amount
Disconnecting and dismantling the existing indoor type VCB/ outdoor RMU 11 KV horizontal draw out type VCB trolly of capacity 400/ 630 Amps from location and repair/ overhauling including replacement of damaged minor spare parts and carrying out with the following all as specified and as directed by Engineer-in-Charge. Note :- Major spare parts will be measured & paid seperately. (i) Inspecting/ overhauling of manual/ motorised spring drive mechanism by checking mechanism, motor and gear assembly, big gear assembly, stop bolt assembly, main shaft interlocking assembly, closing spring assembly, small cam with screw, motor cut-off limit switch, butter fly switch assembly, replacement of damaged control wiring DC/ AC for smooth function of VCB, testing of contact resistance, insulation resistance and apply multi grease lubricant to function smoothly. (ii) Inspecting/ overhauling of tripping assembly, earth fault release assembly, tripping coil, auxiliary switch and checking of electrical wiring system, replacement of control wire fuse, MCB and connected accesories all as specfied and directed by Engineer-in-Charge. (iii) Inspecting/ overhauling/ cleaning and inspecting through insulators, vacuum interuptors by carbon cleaner solution and apply dry graphite conductive sealant for electrical contacts to avoid carbon deposits on contact surfaces. (iv) Assembling all items/ components parts to the respective position & testing the breaker with High Voltage(DC) and meggering before and after high voltage test complete. (v) Overhauling, calibration and secondary injection of over current earth fault relays/ release on each multiple setting readjustment by artificial load complete all as specified including testing complete. (vi) Contarctor should contact PGVCL for proper tripping paramters and same should be set such that proper coordination is maintained in tripping between PGVCL VCB and MES incoming VCB and between sub feeder VCB in MES power house and the same to be record and submitted to Engineer-in-Charge.
Material and labour for comprehensive maintanence of following transformer any type, Opening the top cover of the transformer carefully at site and draining of transformer oil, and removing the core and windings for finding out the fault and refixing the same after repairs, refilling and or topping up with new transformer oil confirming to IS-335 of 1993 having suitable dielectric strength, including all tests of transformer to be done as per standared, cleaning of transformer & its parts using proper cleaner if transformer can not be repaired, the same shall be transported to workshop to carry out repair & rewinding and back as approved by Engineer-in-Charge complete of the follwing sizes:- Note : (a) Transformer oil shall be measured and paid separetely. (b) Spare parts will be measured & paid in appropiate item of schedule. (c) Opening and assembling of transformer shall be carried out at the presense of officials. (d) Labour charges shall be deemmed to be included for replacement of parts mentioned here- in-before/ here-in-after. (e) Test Report after concluding all test shall be submitted with duly signed by licensed technician.
Removal of burnt HT coil winding and replacement of the same with new copper wire coil including necessary insulation material like impregnated paper or super enamelled and keeping the core and windings in to the hot air oven till the moisture evaporate and achieving proper insulation resistance complete all as specified and as directed.
Removal of burnt LT coil winding rewinding of the same with new copper strip including necessary insulation materials and keeping the core and windings in to the hot air oven till the moisture evaporate and achieving proper insulation resistance results complete all as specified and as directed.
Supply only HT bushing any type and size complete complete all as specified and as directed.
Supply only LT bushing any type and size complete complete all as specified and as directed.
Supply only cracked/ worn out synthetic rubberized cork gasket 10mm thick for top cover of transformer capacity upto 250 KVA complete all as specified and as directed
Supply only cracked/ worn out synthetic rubberized cork gasket 10mm thick for HT/ LT bushes complete all as specified and as directed
Supply only silica gel in exist breather as required complete all as specified and as directed
Supply only tap changer switch including all accessories of any capacity complete all as specified and as directed
Supply only paint from approved brand complete all as specified and as directed
Supply only temperature gauge any type and size complete all as specified and as directed
Supply and replacement of transformer oil confirming to IS 335, having dielectric strength 60 KV completely including opening of top plate of transformer and refixing complete all as specified and as directed by Engineer-in-Charge.
Supply and fix super heavy duty capacitor 5 KVAR APP type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix super heavy duty capacitor 7.5 KVAR APP type complete all as specified and as directed by Engineer-in-Charge.
Supply and fix super heavy duty capacitor 10 KVAR APP type complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing Gun metal gate valve 25mm dia heavy duty high pressure with crutch or butterfly handle screwed both ends for iron pipes along with suitable GI plug complete all as specified and as directed.
Supply and fixing Gun metal gate valve 40mm dia heavy duty high pressure with crutch or butterfly handle screwed both ends for iron pipes along with suitable GI plug complete all as specified and as directed
Supply and fix super heavy duty capacitor 12.5 KVAR APP type complete all as specified and as directed by Enginner-in-Charge.
Supply and fixing replacement of cracked/ worn out synthetic rubberized cork gasket 10mm thick for HT/ LT bushes complete all as specified and as directed
Supply and fixing, replacement of silica gel breather assembly complete with silica gel upto 250 KVA transformer complete all as specified and as directed
Supply and fixing, replacement of silica gel in existing breather as required complete all as specified and as directed
Supply only spare parts suitable for C&S, ALSTOM, AREVA CG VCBs VCB Panels Boards, Rating 11KV, 400/ 630A, indoor type complete all as specified and as directed by Engineer-in-Charge.
Multi Function meters, Digital type 96 x 96mm, Aux Supply 230 Volts AC, including conncetions and testing
Opening/ Closing Push Button Assembly
Motor Charging mechanism gear Drum box
Vaccume Interupter assembly
Limit Switches
Closing Coil Assembly 30V DC
Spring Charging Motor 230 Volts
Spring return latch
Tripping Coil assembly 30 Volts DC
Auxiliary Switch with link
Spout Insulator assembly (3 Phase) feeder side
Spout Insulator assembly (3 Phase) Bus bar side
Potential Transformer, Resin cast dry type 11KV/ 110 Volt ,100VA burden, Class 1 Accuracy, Trolly mounted.
Current Transformers, resin cast dry type, 60/5A Class 0.5 and 5p10, 15VA
TNC Switch, 25A,Type:BCA02P004E86/S (Kaycee)
Indicating Lamps LED type, 30Volts DC Make: Teknic or equivalent.
Indicating Lamps LED type, 110Volts AC Make: Teknic or equivalent.
Ammeters, Digital type 96 x 96mm, CTR 50/ 30/ 5 Amps Class 1 acuracy, Aux Supply 230 Volts AC type:DM3258 Conzerv (Schneider Electric)
Voltmeters, Digital type 96 x 96mm, Voltage 11KV, PTR 11 KV/ 110V, class 1 acuracy, Aux Supply 230Volts AC, Type:DM 3257 Make Conserv (Schnieder electric)
Relay Nuemerical IDMTL+Inst O/C &E/F, suitable to exisiting relay
Master trip relay Tripping relay suitable to exisiting relay
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth in hard/ dense soil for laying of cable/ GI pipe and getting out complete all as specified and as directed.
Returning, filling in including spreading levelling watering well ramming in layers not exceeding 25 cm each complete all as specified and as directed.
Removing surplus soil to a distance outside MD land and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Material and labour for dry clean river sand for cushioning of cable in trenches for cable protection including spreading, leveling and hand punning complete all as specified in SSR Part-I and as directed. Note :- Only compacted thickness of sand will be measured and paid separately.
Cutting existing road surface or hard standing, bituminous topping 15 cm but not exceeding 30 cm girth for laying of pipes/ Cables and making good distrubed surface to match with existing complete all as specified and as directed.
Material and labour in replacement for High density polyethylene pipes (HDPE) of pressure 4 KG/cm2 pipe,110mm dia for road crossing of cables or for cable protection of cable above ground surface complete all as specfied and as directed
Material and labour for cement concrete 1:2:4, type B-2 (using 40mm graded stone aggregate) as in support of CI pipes, foundation and hard standing finishing even and fair without using extra cement complete all as specfied and as directed
Supply and fix of suitable type and size FRP bus bar support insulator (Bridge Insulator) for fixing the extended aluminium/ copper bars, for cable terminations, duly fixed in the body of the panel board including galvanized steel bolts, nuts, washers and necessary drillings, in the panel body, complete all as specified and as directed.
Material and labour for bring the van mounted full automated underground cable fault locator machine at site for find out HT/ LT cable fault in underground completely all as specified and as directed by Engineer- in-Charge. Note: (a) Fault machine, cable & T&P required shall be arranged by the contractor. (b) Cable jointing kit for HT/ LT is measured separately
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and as directed by Engineer-in-Charge.
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty)11000 Volts grade with stranded aluminium conductor of size 95 Sqmm 3core and complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, class HV Type I, flat, size 300mm x 180mm x 40mm. laid in trenches complete all as specified and as directed.
Maintaining of HT over head lines by trimming the of tree branches touching to the HT/ LT over head conductors lines upto 03 meter away from the live conductors surrounding area complete all as specified and as directed at site complete. Note :- Cost of labours deemed to be including cutting the tree branches and depositing the tree branches 50 Meter away from the poles or as directed by Engineer-in-charge complete.
Supply and erection of prestressed concrete pole of length 11 Meter, 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as specfied and as directed by Engineer-in-Charge.
Supply and conncetion of new Pin type, porcelain, vitreous, white, brown insulator on pole or any structure including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade including removing old damaged insulator from pole complete all as specfied and as directed by Engineer-in-Charge.
Supply and fix porcelain loop type insulator, vitreous porcelain, white, brown or green: Large size, with overall dimensions 90mm x 140mm, clearance of hole 25.5mm complete all as specified and as directed by Engineer-in-Charge.
Supply and erection of Cross arms, bracings, supports, clamps and back plates, equal channel, anchor for stay wire, stay strand fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or complete all as specified and as directed.
Clearing and cleaning of vegtation and creeper around various 4/ 2 pole structure, on chain link fencing complete all as specified and as directed by Engineer-in-Charge.
Material and labour for MS chequred plate of thickness 5mm including cutting into required shape fixing on equal angle complete all as specified and as directed by Engineer-in-Charge.
Material and labour, earthing complete for machinary/ equipment installed at power house/ sub station with galavanised steel earth plate electrode of size 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less then 2.25 meter deep below the normal ground level) with top edge of the earth plate not less then 1.5 meter below normal Ground level connected galvanised earth strip 32 X 6mm by means of bolts, nuts, washers and check nuts all shown in electrical plate No. 5 of SSR Part- I connected to main board/ disribution board complete. Earthing GI lead and GI protection pipe 15mm dia light grade upto 7.5 meter from earth pit connecting to machinary/ equipment, testing point, all as specified and testing on completion all as per directed. Note :- (i) The unit rate shall also included for earth work in hard/ dense soil, PCC type C-1 (1:3:6) chamber, PCC 1:2:4 type B-1 cover 50mm thick reinforced with 8mm dia TMT bars,150mm c/c both ways, funnel with watering pipe 20mm dia medium graded, GI protection pipe light grade 15mm dia and wire mesh complete in addition to items No. 1 (a) to (e) of preamble (notes) under sub heading earthing specified on SI page No. 389 of SSR Part - II. (ii) Earthing strip and GI protection pipe beyond 7.5 meters will be measured and paid separatelly if required under appropriate Schedule. (iii) Earthing shall be tested as specified in casual 19.137 of SSP PART- I 2009, to the entire satisfication of Engr-in-Charge. (iv) On testing after completion of earthing, if the desired earth resistance is not obatined the earthing wiil be redone by the contractor at his on risk and cost to the entire satisfaction of the Engr-in-charge.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing as required 32 X 6mm dia galvanised steel strip complete all as specified and as directed.
Material and labour for restringing of HT/ LT ACSR OH line 3 wire conductor upto permissible sag after dismantling the binding wires from insulators and jumper connections complete and providing with new aluminium conductors as binding wire of existing size with insulators and jumpers all as specified by Engineer-in-charge. (suitable size ladder and tripod shall be provided by contractor). Note- Three line together will be measured as one length.
Material and labour for painting of grey colour on transformer and painting MES no in white colour of suitable font all as directed by Engineer-in-charge
Supply and distribution of 40mm crushed stone aggregate of suitable thickness at various transformer location including removing old stone layer and reuse same all as specified by Engineer-in-Charge.
Material and labour for painting of white layer on HT/ LT pole of suitable height and numbering the pole in black colour of suitable font and size complete all as specified and as directed.
Removing HT connection from VCB and rearrange of Each HT cable in trench and fixing of cable with GI strip along the trench wall including removing unservicable HT cable from VCB room complete all as specified and as directed.
Material and labour for Brick work work with old size sub class 'B' bricks, straight or curved on plan exceeding 6 meter mean radius built in CM 1:6 complete all as specfied and as directed.
Material and labour for rendering 10mm thick on stone masonry surface or surface other than fair face of brick-work in 1:6 and finished even and smooth with out using extra cement complete all as specified and as directed.
Material and labour for shifting of transformer from power house to site and installation on two pole structure or PCC block including connceting incoming HT and LT line, removing damaged unservicable transformer to power complete all as specified and as directed.
Supply and fixing stay assembly complete with accessories as showing in electrical plate No. 1 with 16mm dia stay rod (loop type insulator, stay strand, stay clamps, excavation and PCC will be measured and paid separately on as required basis) complete all as specified and as directed.
Supply and fix/ stringing aluminium conductor steel reinforced, any cross sectional area, including material and labour complete all as specified and as directed.
Material and labour for lightning arresters nominal discharge current Peak 65 KA rating, suitable for operation on HT 11000 volts system, comprising of zinc oxide disks, electrodes, fibre re-inforced composite structure, non tracking weather resistant shedded heat shrinked polymeric housing for with standing from the effects of pollution, rain, heat, and with moisture seal, stainless steel bolts and nuts, stainless steel end fitting cups and fixing arrangements, complete all as specified and as directed. Make-Bhel/ Jaipurya brothers/ National.
Repairing/ servicing/ overhauling of gang operated device 11000 volts, 200/400 Amps including greasing all the moving parts and applying white petroleum jelly at the contact points tightening all jointing/ bolts nuts including replacing wornout the bolt and nuts complete all as specified and as directed. Note: (a) All the spares replaced will be measured and paid separately, supply only the following spares for repalcing in repairs/ servicing. (b) Labour charges shall be deemed to be included for replacement of parts mentioned here- in-before/ here-in-after.
Supply only Moving contact blades
Supply only Fixed contact jaw copper
Supply only PG clamps of suitable size as per site requirement.
Material and labour for painting and marking alternate yellow and black strip 30 cm height, upto 1.5 meter height from coping, painting HT/ LT pole number, letters/ figures by black paint complete all as specified and as directed.
Material and labour for framed work as in gates of angle or other section with gusset plates, rails, braces complete, drilled for fixing of steel sheeting or other covering. Doors to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing with all locking arrangement complete all as specified and as directed.
Supply and fixing Galvanized iron chainlink fencing 4mm dia including line wires 50mm x 50mm size mesh and type to any type of standards, rails, straining bolts including provision of binding wire upto a height of 3 meters complete all as specified and as directed.
Material and labour for compound girders and stanchions, lattice girders, aerial masts, staging for fencing post and the like including caps, bases, splices built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates complete all as specified and as directed.
ARTI CONSTRUCTION (BID ID -3078859)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .