| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹5.4 L+₹8,000 (1.50%)Rejected-Finance | L2 | Rejected-Finance Not L1 | |
| 3 | L3₹5.5 L+₹10,000 (1.87%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 4 | L3₹5.5 L+₹10,000 (1.87%)Rejected-Finance | L3 | Rejected-Finance Not L1 | |
| 5 | L4₹5.5 L+₹14,000 (2.62%)Rejected-Finance 0 NEAR SATYANARAYAN SOCIETY GAYATRI MANDIR ROAD 0 BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L4 | Rejected-Finance Not L1 |
Tender Value
₹5.4 L
Closing Date
28 Jul 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Anuraj Singh Rana, AE (Civ), Offg GE (AF)Bhuj
Bhuj-Kutch PIN- 370001
Repair and maint to temperature humidity monitoring sys installed in danger bldg PMS II at AF Bhuj
2020_MES_360422_1
3020/eQ/08/20-21/E3
Limited
Job Works
Item Rate
30 days
GE (AF) Bhuj
The firm must be registered with HQ CWE (AF) Bhuj as approved supplier to carryout general order supply and job work
1 document required · 1 mandatory
₹0
Exempted
28 Sept 2020
13 Jul 2020
29 Jul 2020
13 Jul 2020
28 Jul 2020
13 Jul 2020
30 days
Amount
1. Supply install commissioning and Testing of flowchart based programmable RTU for Monitoring Temperature and Humidity for Package Type AC 72 TR along with battery back and up SMS to MES in case of power failure and unit fixed in enclosure made out of MS powder coated CRCA 1.6 mm Thickness indoor Panel mounting on wall of minimum size 300 x 300 x 200 mm all as directed with following:- (a) Input Output as per requirement for measuring temperature and humidity (b) Serial ports to connect modem for communication (c) Digital inputs (optical isolation) for on/off status (d) Digital outputs (for start/stop function) (e) Isolated Analog Inputs for monitoring of Temperature & humidity (f) Local Display, membrane keyboard and data storage to feed input in RTU. (g) Compatibility with GSM Modem for indicator (to send data to MCS) (h) Isolation transformer for RTU protection (j) Make- Cimcon/Siemens /Motorola/Tesco /Clevermesh or equivalent 2. Editing SCADA software Version in Armory PC with required tags for Central Monitoring through wireless communication for Master Control Station Make: CIMCON. (01 Each) 3. Supply and fix in replacement of wireless modem suitable for GSM/GPRS based communication system from RTU to MCS. GSM/GPRS modem to be mounted in RTU enclosure. Make: CIMCON/ Siemens/Motorola (01 Each) 4. Supply and fix in replacement of RTD sensor for the room and Duct temperature measurement with installation accessories TO BE INSTALLED (inside the room and duct to measure temperature) Make-Waree / RADIX / Wika. (01 Each)
5. Supply and fix in replacement of humidity sensor with Transmitter for the room Humidity measurement (Make-Masibus/Wika/Waree/Radix) (01 each) 6. Supply and fix in replacement of Process Indicator with refransmission output for monitoring of temperature and humidity (to be installed in RTU panel) Make-MULTISPAN/Radix/Masibus (01 each) 7. M and L for replacement of flame proof wiring complete with 2 x 1.5 Sqmm multicore multistranded copper conductor fire Retardant PVC insulated and Shielded cable 650/1100 volts grade drawn through and incl ERW steel conduit of minimum 20 mm dia external (which shall be increased as per actual site requirement in accordance of clause No.19.125 07 SSR part-I) with wall thickness not less than 1.6 mm, with all conduit accessories like bends, junction boxes etc. (Make : Polycab /Havells/Finolex ) (120 RM) 8. M and L for replacement of flame proof wiring complete with 3 x 1.5 Sqmm multicore multistranded copper conductor fire Retardant PVC insulated and Shielded cable 650/1100 volts grade drawn through and incl ERW steel conduit of minimum 20 mm dia external (which shall be increased as per actual site requirement in accordance of clause No.19.125 07 SSR part-I) with wall thickness not less than 1.6 mm, with all conduit accessories like bends, junction boxes etc. (Make : Polycab /Havells/Finolex ) (120 RM) 9. Supply and fix in replacement of 2 Nos GSM Sim Card Rental and SMS charges for the period of Twelve months. (Make: Vodafone / Airtel / BSNL) (02 Each) Note: - All material, labor and T&P required for complete the job is responsibility of the firm.
Hi-Tech Systems
Sunrise Agency
M/S Divya Enterprise
SHREE BHANU ENTERPRISE
Jyoti Refrigeration
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_402345.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .