Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC accept | |
| 2 | L2₹23.9 L+₹1.8 L (8.31%)Rejected-AOC | L2 | Rejected-AOC accept | |
| 3 | L3₹25.0 L+₹3.0 L (13.6%)Rejected-AOC | L3 | Rejected-AOC accept | |
| 4 | L4₹29.8 L+₹7.8 L (35.4%)Rejected-AOC | L4 | Rejected-AOC accept |
Tender Value
₹16.3 L
EMD Value
₹32,594
Closing Date
15 Nov 2021, 5:00 pmClosed
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
C,O LIS Garh from Moul Khad in Tehsil Palampur Distt. Kangra HP S,head S,E automation for pumping machinery
2021_HPIPH_53275_1
THL-KNG05-729 (10992-11043 dated 8.11.2021)
Open Tender
Supply and Erection
Item Rate
90 days
C, O LIS Garh from Moul Khad in Tehsil Palampur Di
Please refer Tender documents.
9 documents required · 9 mandatory
₹400
₹32,594
Yes
7 Jan 2022
8 Nov 2021
16 Nov 2021
8 Nov 2021
15 Nov 2021
8 Nov 2021
Amount
Supply, Installation, Testing and Commissioning of energy saving variable frequency starter Panel for centrifugal pump made out of 16 Gauge sheet, powder coated dust and vermin proof, wall/ base mounted and front opening door type with copper insulated wiring suitable to operate 2 Nos. Pumps (1working and 1 stand by) each of the rating 125 HP. Starter should be capable enough to handle the following faults like short circuit, over current, under cuttent, over voltage, under volatage, dry run protection and phase loss with LED On/ Off and Trip indicators, Power Quality monitoring and Controlling relay at the incomer Feeder, Should be fitted with surge suppressor Device suiable to protect against class 1 & 2 Surges. Make: Aarmation ELectric Private Limited/ MAS/ ELLES/ Adlec.
Energy Saving varibale frequency starter of 125 HP heavy Duty for smooth start and smooth stop of centrifugal pumps and for the energy conservation in the system. It shold be caable to control the frequency of pumps through out the operation and also should be capable to maintain he power factor of th system within acceptable limits. It should have ambient temperature 50 Degree without derating and have conformal coating class 3c2, so that it can work in any harsh environment like moisture etc. Make: Aarmation Electric Private Limited/ Bechoff/Bosch /Rockwell.
Multi Function meter indicating different parameters like current, voltage, KWH, PF, THD ec with RS. 485 communication make L & T / Amarmation Electrics/ Siemens/ Schnieder.
Main Incommer MCCB Suitable capacity of L&T / Schnieder make on the coming feeder for pumping set confirming to BIS 2516-1985 (latest edition) with neutral linked under voltage release.
LED Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 (part I and II) latest with upto date ammendment.
LED On / Off indicator and push button, Control and power wiring, Power capacitor, Cooling, Fan 230 VAC, Control terminal, Buss Bar, i.e. Bolt, insulator, etc.
Input Choke for Energy Saving variable Frequency Starter for 50 HP which should be installed at the input of VFD starter, So that there should be proper protection in case of any voltage surge and distortins in signal Make: Aarmation Electric/ MAS/ ELLE
Control Transformer complete in all respect as per direction of Engineer in Charge.
Power and Control wiring and Bushwar complete in all respect as per direction of Engineer in Charge.
Surge Supressor device with Isolating MCCB to Eliminate the power surge due to lightening and System Surge.
Power quality monitoring and controlling relay with control contractor to safeguard the electronic and Electric elements.
Indipendent Control Panel with Switch Fuse Unit and Fuse of Suitable Amperage to eliminate the KitKat fuses of HPSEB . Make:- Amarmation / Siemens/ Schnidar/ L&T
PLC ( Programme Logic Controller) with appropriate digital and analoge inputs and outputs to give automatic command to Star Delta Starter Panel/ Energy Saving Variable frequency starter panel make:- Aarmation electric/ Bechoff Automation/ Rockwell Automation.
Electric Relay card 8 Channel complete in all respect as per the direction of Engg. In charge.
SMPS 4.5 amps to energise PLC System complete in all respect as per the direction of Engg. In charge.
HMI 7" display with IOT to give on & off command manually and alos to show pump running and breakdow status at pump station make Aarmation electric/ Bechoff Automation/ Rockwell Automation.
Control MCB for automation system complete in all repsect as per the dirction of Engg. In charge.
Level Sensor to indicate the water level of tank remotely complete in all respect.
Shielded Data Cable for Communication of level sensor with PVC.
Cloud Gate way for data cluding to server complete in all respect as per the direction of Engg. In charge.
SCADA software to be installed in Laptop/ PC to remotely monitor and control the openting of Pumps and alos to analysis the pump start and stop history loggine, fault status, Fault History, Power Quality parameter like PF, Current, Voltage, KWH, THD etc make Aarmation electric/ ROckwell Automation /.Backoff.
Cloud space for data storage an cloud/ Server. Complete in all respect as per the direction of Engg. In charge.
Installation, Commissioning and Software Development complete in all respect as per the direction of engg. In charge.
Transporation and Carriage charge for panel till site complete in all respect as per direction of Engineer in Charge.
P C Construction
sadeep kumar
Dogra Construction Company Pvt Ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .