Electrical Installation Work for the office Accomodation of the Dte. of Anti-Corruption Branch for Enhanced effectiveness at 5th Floor Benfish Tower and 6th floor of Benfish Bhawan ----SITC of Fire Detection System at 5th Floor of Benfish Tower
2026_WBPWD_5075828_1
WBPWD/EE/BED/e-NIQ-121/2026-27
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Benfish Bhawan
Please refer Tender documents.
6 documents required · 6 mandatory
₹15,639
28 Sept 2026
28 Sept 2026
3 Oct 2026
28 Sept 2026
1 Oct 2026
28 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation,Testing & Commisioning of Microprocessor based addressable OPC complied fully networkable fire alarm control panel ( VDS/ UL / LPCB /FM approved) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 320 character alpha- numeric liquid crystal display.The panel shall be soft addressable type and shall beable to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered.The Panel should be able to store minimum 4000 log events in its memory (EPROM).The panel should have extra loop cards lot for future expansion. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 1 | nos | - | - |
| 2 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector (VDS/UL/LPCB/ FM approved )with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector is to be provided without extracost) the detectors should have built in response indicator with LED indicator.The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not
damage the detectors. Degree of protection as per OEM Standard. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 100 | Each | - | - |
| 3 | Supplying, installation, testing & commissioning of response indicator on surface /recessed MSB ox with metallic cover having two LED and Degree of protection as per OEM Standardetc. complete with all connections etc as required. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 2 | Each | - | - |
| 4 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) through 20 mm dia PVC 'FR' type Rigid Conduit pipe including S & Laying of the 20 mm dia PVC FR rigid conduit pipe with necessary arrangement as per GS. (Make : Precision/ AKG/ Universal/ Polycab) on the surface of the wall. | 1,300 | Mtr | - | - |
| 5 | Supply, Installation, Testing & Commissioning of Addressable Loop Powered /panel powered Hooter (sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator as per NFPA (Note :Hooter without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). ( VDS / UL / LPCB / FM approved ) approved. Degree of protection as per OEM Standard. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 2 | Each | - | - |
| 6 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / LPCB / FM approved ) with in built short circuit fault isolator as per NFPA (Note : MCP without built-in fault isolator is also acceptable with one independent short circuit fault isolator is to be provided without extra cost). Degree of protection as per OEM Standard. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 3 | Each | - | - |
| 7 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector ( VDS / UL / LPCB / FM approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 58 deg. C to 68 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA (Note : Detectors without built-in fault isolator is also acceptable with one independent short circuit fault isolator after every four (04) detector in the loop is to be provided without extra cost) the detectors should have built in response indicator with LED indicator.Degree of protection as per OEM Standard. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 4 | Each | - | - |
| 8 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. (Make-Notifire/ Notofire/ Siemens/ GST /Secutron/ Securiton/ As per Direction of EIC) | 2 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
2911_ii.pdf
Tender Documents • 0.50 MB
BOQ_5167130.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .