Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹58.2 LAccepted-Finance E 60 INDUSTRIAL AREA HARIDWAR 249401 | HARIDWAR | HARIDWAR | UTTARAKHAND | 249401 | L-1 | Accepted-Finance financial evaluation | |
| 2 | L-2₹58.6 L+₹36,237.80 (0.62%)Accepted-Finance | L-2 | Accepted-Finance financial evaluation | |
| 3 | L-3₹58.7 L+₹47,825 (0.82%)Accepted-Finance 1759 SECOND FLOOR SECTOR 28 FARIDABAD 121008 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121008 | L-3 | Accepted-Finance financial evaluation |
| Sl No | Description | Qty | Unit | GOGOAL HYDRO PVT. LTD. L1 | VM POWER AND INFRATECH L3 | MS Projects L2 |
|---|---|---|---|---|---|---|
| 1.00 | Daily Operation, monitoring and logging of both unit and related work including transformer, switchyard equipments etc. with all labour , material ,T&P etc. required for proper completion of work. | 12 | Months | 30,72,000 ₹36,24,960 Lowest | 30,78,000 ₹36,32,040 | 30,75,600 ₹36,29,208 |
| 2.00 | Daily cleaning of all E&M equipment, Control & Protection panels including all labor T&P etc. required for completion of work | 12 | Months | 3,34,800 ₹3,95,064 Lowest | 3,37,200 ₹3,97,896 | 3,36,000 ₹3,96,480 |
| 3.00 | Site visit of Engineer required for E&M equipment i.e. SCADA & PLC
ACB & SF6 Circuit Breaker
Power & Auxiliary transformers
Battery charger, UPS & Battery Bank
Lubrication oil system
Oil pressure unit.
DE & NDE bearing of generator
Turbine & MIV
CVT 250kVA
up to the satisfaction of plant in charge including all labor T&P etc. required for completion of work. Spares shall be supplied by UJVNL | 10 | Nos | 3,40,900 ₹4,02,262 Lowest | 3,41,100 ₹4,02,498 | 3,41,000 ₹4,02,380 |
| 4.00 | Preventive maintenance of all E&M equipment of plant on routine basis to minimize breakdown of E&M equipment by skilled manpower & maintain proper record including all labor, material T&P etc. required for completion of work. The brief description of preventive maintenance works described as given below: -
i. Greasing, lubrication of all equipment.
ii. Cleaning of Cooling water filters.
iii. Cleaning of turbine floor, control room, Service Bay and make it oil/dust free.
iv. Filtration/Dehydration of LOS & OPU oil regularly.
v. Filtration/Dehydration of Transformer oil.
vi . Checking & maintaining oil level in LOS, OPU & Switchyard equipment.
vii. Checking tightness of Nut & Bolts of E&M equipment. | 12 | Months | 3,40,800 ₹4,02,144 Lowest | 3,42,000 ₹4,03,560 | 3,42,360 ₹4,03,984.8 |
| 5.00 | General Servicing & Breakdown maintenance of 62.5 kVA DG Set for breakdown free operation of DG set equipment including all labor T&P etc. required for completion of work in a year | 3 | Nos | 1,20,150 ₹1,41,777 Lowest | 1,20,270 ₹1,41,918.6 | 1,20,150 ₹1,41,777 Lowest |
| 6.00 | Mandatory Consumables before first Running bill of O&M work. Supply of Silica Gel 1 Kg packet | 20 | kg | 10,200 ₹12,036 Lowest | 10,600 ₹12,508 | 10,400 ₹12,272 |
| 7.00 | Supply of Filter Element 2.0018 H20XLA000P, Make-EPE (LOS)as per sample | 8 | Nos | 1,12,800 ₹1,33,104 Lowest | 1,16,800 ₹1,37,824 | 1,14,400 ₹1,34,992 |
| 8.00 | Supply ofFilter Element YSS-030, Make-EPE (LOS) as per sample | 6 | Nos | 76,800 ₹90,624 | 77,400 ₹91,332 | 76,200 ₹89,916 Lowest |
| 9.00 | Supply of Filter Element 0030 D 010 ON, Make-Hydac (OPU) as per sample | 6 | Nos | 1,35,000 ₹1,59,300 Lowest | 1,36,200 ₹1,60,716 | 1,35,900 ₹1,60,362 |
| 10.00 | Supply of Filter Element 0060 R 005 ON, Make-Hydac (OPU) as per sample | 6 | Nos | 1,11,000 ₹1,30,980 Lowest | 1,12,800 ₹1,33,104 | 1,12,200 ₹1,32,396 |
Tender Value
₹49.4 L
EMD Value
₹98,860
Closing Date
4 Dec 2025, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE EM SHP
Executive Engineer (EM-SHP) Guptkashi
Annual Operation and Maintenance of Kaliganga-I SHP
2025_UJVN_88869_1
10/EE(EM-SHP)/KG-I/25-26
Open Tender
Electrical Works
Item Rate
365 days
Guptkashi
As per Tender Document
2 documents required · 2 mandatory
₹2,360
General Manager SHP UJVNL Limited, Maner Rishikesh
₹98,860
6 Dec 2025
13 Nov 2025
6 Dec 2025
13 Nov 2025
4 Dec 2025
14 Nov 2025
Daily Operation, monitoring and logging of both unit and related work including transformer, switchyard equipments etc. with all labour , material ,T&P etc. required for proper completion of work.
Daily cleaning of all E&M equipment, Control & Protection panels including all labor T&P etc. required for completion of work
Site visit of Engineer required for E&M equipment i.e. SCADA & PLC ACB & SF6 Circuit Breaker Power & Auxiliary transformers Battery charger, UPS & Battery Bank Lubrication oil system Oil pressure unit. DE & NDE bearing of generator Turbine & MIV CVT 250kVA up to the satisfaction of plant in charge including all labor T&P etc. required for completion of work. Spares shall be supplied by UJVNL
Preventive maintenance of all E&M equipment of plant on routine basis to minimize breakdown of E&M equipment by skilled manpower & maintain proper record including all labor, material T&P etc. required for completion of work. The brief description of preventive maintenance works described as given below: - i. Greasing, lubrication of all equipment. ii. Cleaning of Cooling water filters. iii. Cleaning of turbine floor, control room, Service Bay and make it oil/dust free. iv. Filtration/Dehydration of LOS & OPU oil regularly. v. Filtration/Dehydration of Transformer oil. vi . Checking & maintaining oil level in LOS, OPU & Switchyard equipment. vii. Checking tightness of Nut & Bolts of E&M equipment.
General Servicing & Breakdown maintenance of 62.5 kVA DG Set for breakdown free operation of DG set equipment including all labor T&P etc. required for completion of work in a year
Mandatory Consumables before first Running bill of O&M work. Supply of Silica Gel 1 Kg packet
Supply of Filter Element 2.0018 H20XLA000P, Make-EPE (LOS)as per sample
Supply ofFilter Element YSS-030, Make-EPE (LOS) as per sample
Supply of Filter Element 0030 D 010 ON, Make-Hydac (OPU) as per sample
Supply of Filter Element 0060 R 005 ON, Make-Hydac (OPU) as per sample
Supply of Forebay Ultrasonic water level transducer, Model- ULIT, Range 0.3-6M, Output 4-20mA, Power supply 24VDC, 2 wire, Make- Scientific devices. (As par sample)
Supply of Pressure Transmitter range 0 to 20 bar, Output 4-20mA, Make- Gefran (As par sample)
Supply of HP make LCD monitor ( 54.6cm) 100-240V for SCADA (As per sample)
Supply of LED light for switchyard 200W, Model - BJFL200W LED I WHTG, I/P voltage-240, 50 Hz, IP 66, Make-Bajaj (As per Sample)
Supply of LED light for outer area of powerhouse 120W, Model- BRTFG 120W LED, I/P voltage-240, 50 Hz, IP 66, Make-Bajaj (As per Sample)
Supply of LED light for Machine Hall, Product Name - BGHBC 150W LED XL NB, Product Code- 169984, I/P voltage-240, 50 Hz, IP 65, Make-Bajaj (As per Sample)
Supply of Grease 1kg packet
Supply of Cardium compound for EOT ropes
Supply of CRC for Contactor cleaner (500ml bottle)
Supply of Straub OD 60.3mm, material AISI 304 (As per Sample)
Supply of Straub 50.8mm, material AISI 304 (As per Sample)
Supply of Multipurpose Expandable PU foam Insulation sealant PUF750, 750gm
Supply of Petroleum Jelley
Supply of Vacuum oil
Supply of EOT gear box Oil/Grease
Supply of EOT Hydraulic Thruster oil
MS Projects (BID ID -408245)
VM POWER AND INFRATECH (BID ID -408275)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TD10.pdf
Tender Documents • 1.28 MB
BOQ_105417.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .