Construction of five class rooms and construction of toilet block (Pre - fabricated work) in kendriya Vidyalaya Farsali.
2023_RES_60379_1
503/RWD/TENDER/2022-23 DATE 24-06-2023
Open Tender
Civil Works - Others
Item Rate
181 days
KAPKOT
Please refer tender documents.
1 document required · 1 mandatory
₹4,720
LEKHASHIRSH 0515008000100
₹1.1 L
2 Aug 2023
1 Jul 2023
13 Jul 2023
1 Jul 2023
13 Jul 2023
1 Jul 2023
Amount
Earth work in excavation by mechanical means (Hydraulic Excavator)/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.in all kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - -All work upto plinth level in 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth inCement mortar 1:6 (1 cement : 6 coarse sand
Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 6 coarse sand)
Half brick masonry with F.P.S. bricks of class designation 75 in superstructure abov plinth level upto floor V level inCement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every third course of half brick masonry (with F.P.S. bricks).
Providing and laying in position specified grade of reinforced cement concrete1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness), includingReinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate20 mm nominal size)
Filling available excavated earth (excluding rock) in trenches, plinthsides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m.
Centring and shuttering including strutting,ropping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Centring and shuttering including strutting,ropping etc. and removal of form forCentring and shuttering for foundations, footings, bases of columns, etc. for mass concrete.
Centring and shuttering including strutting,ropping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. TMT bars Fe500D
Steel work in built up tubular (round, square or rectangular hollow tubes etc.)trusses etc., including cutting, hoisting, fixing in position and applying a primingcoat of approved steel primer, including welding and bolted with special shapedwashers etc. complete.Hot finished welded type tubes
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should besupplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Flashings/ Aprons.( Upto 600 mm)
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories coupler110mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 110mm diameter
12.43 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised -PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110MM
Brick edging 7cm wide 11.4 cm deep to plinth protection with commonburnt clay F.P.S. (non modular) bricks of class designation 7.5 includinggrouting with cement mortar 1:4 (1 cement : 4 fine sand).
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including finishing the topsmooth.
12 mm cement plaster of mix1:6 (1 cement : 6 fine sand
Providing and fixing in position factory made non asbestos fibre reinforced aerated cement sandwich wall/roof/floor light weight solid core panels made of light weight cement concrete core composed of OPC cement, pulverized flyash, quick lime,cotton pulp & Gypsum in mortar state mixed with aeration agent in a preset mould. The outer face on both sides of the panels will be non asbestos fibre cement board confirming to IS 14862:2000. These solid wall panels are installed using Galvanized iron steel tracks/C channel of 1mm thick of required sizes as recommended by manufacturer’s and fixed to floor and RCC soffit in plumb to each other with steel screw/fasteners. The panel shall be fixed vertically with tongue &groove joint with cement based polymer modified jointing compound. The exposed surface finished with fibre mesh/glass fibre tape with polymer based jointing compound having superior flexibility. Panels should be used as floor & roofing with additional structural support, steel or RCC depending upon the design. All the operation shall be completed in all respect as per drawings, Manufacturers specifications and under the overall direction of Engineer-in-Charge (Cost of all the material is included except “tracks/C channel” which will be paid separately).Non load bearing panels 75mm thick of required size (minimum 5mm thick fibre cement board)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate.
Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick.
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as require including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters:30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing ISI marked oxidised M.S.sliding door bolts250x16mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 200x10 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, 150x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS125 mm
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete.With 4.0 mm thick glass panes.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shadeTwo or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture.
providing and applying white cement based putty of average thickness 1mm of approved brand and manufacture, over plastered wall surface to prepare the surface even and smooth complete
Distempering with 1st quality acrylic washable distemper (ready made) of approved manufacturer and of required shade and colour complete, as per manufacturer’s specificationTwo or more coats on new work.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and includingpriming coat of exterior primer applied @ 2.20 kg/10 sqm)
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) R.C.C. top slab with 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 (1 cement: 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finishedWith F.P.S. bricksInside dimensions 455x610 mm and 45 cm deep for single pipe line :
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honeycomb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacture ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm includingpointing the joints with white cement and matching pigmentetc., complete.
White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C. brass pillar tap.
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mmWhite Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work)20 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including refilling etc. (external work) 15 mm dia. nominal bore
Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe.
Providing and fixing ball valve (brass) of approved quality completeHigh or low pressure with plastic floats15 mm nominal bore
Providing and fixing brass bib cock of approved quality15 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass unions15 mm nominal bore45 cm length
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories single tee 110x110x110mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (i) Single socketed pipes110 mm diameter
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes75 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories bend 110mm diameter
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
GOLJU CONSTRUCTION
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_73330.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .