Tender Value
₹32.1 L
EMD Value
₹64,200
Closing Date
13 Feb 2023, 6:00 pmClosed
GE (AF) BHUJ
GE (AF) BHUJ ,KHAVDA ROAD, BHUJ GUJARAT-370001
PROVN OF STABILIZER IN TRANSMITTER BUILDER S/BY POWE SUPPLY FOR PAR RADAR AND AC IN S/BY BCR SECTION, SERVER ROOM CUM REST ROOM FOR GDCC AND SPECIAL REPAIRS TO TOILETS AND BATHROOM OF AIRMESS BILLETS IN 308 TRU AT AF STN BHUJ
2022_MES_570177_2
8637/V/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) BHUJ
AS PER NOTICE OF TENDER
7 documents required · 7 mandatory
₹500
GE (AF) BHUJ
₹64,200
Yes
4 Mar 2023
25 Jan 2023
15 Feb 2023
25 Jan 2023
13 Feb 2023
1 Feb 2023
28 Jan 2023 - 30 Jan 2023
Amount
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) and removing rubbish off the MD land complete all as specified and directed by Engineer-in-Charge.
Material & labour for 75mm thick PCC 1:3:6 type C-2 ( using 40 mm graded stone aggregate ) as in plinth protection finished even and smoth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
Material & labour for 25mm thick cement concrete type B0 1:2:4 using 12.5mm graded aggregate in sub base floor complete all as specified and directed by Engineer-in-Charge.
Material & labour for non skid ceramic coloured tiles 7 to 8mm thick (sqaure/rectangular) area of each tiles exc. 0.06Sqm but n.exc. 0.11Sqm as per IS - 13755 in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed 15mm thick in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 5.0 but on vertical surface such as in skirting and dados laid over plaster in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material & labour for glazed ceramic coloured tiles in vertical surfaces such as in skirting and dados 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10 mm thick plaster in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Material & labour for 20 mm thick Granite (of any type or Z blank as per discided by Engineer-in-Charge) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer-in-Charge. NOTE : Cost of Screed Bed shall deemed to be included in QUOTED UNIT RATE.
Taking down cement plaster on walls etc, including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering on concrete surfaces 15mm thick in two layers first coat 10mm thick in CM 1:6 and second coat 5mm thick in CM 1:4 with water proofing compound @3% by wt of cement, finished even and fair complete all as specified and directed by Engineer-in-Charge.
Supply only water proofing compound complete all as specified and directed by Engineer-in-Charge.
Material & labour for three coats of white wash incl preparation on new plaster surfaces of wall complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of new or previously untreated concrete or PCC block masonry external surfaces and applying two coats of exterior emulsion paint (in camouflage pattern as approved by the GE) over a coat of primer complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparation of old treated surfaces of wall including brooming down, scrapping down smoke soots etc. and appyinge one coat of white wash on ceiling complete all as specified and directed by Engineer-in-Charge.
Taking up on down steel tubing and connection incl cleaning for refining complete all as specified and directed by Engineer-in-Charge of the following bore of pipe :-
15mm bore of pipe
20mm bore of pipe
25/32mm bore of pipe
Supply & fix CPVC pipes ISI marked, IS-15778 with all fittings for hot and cold water, fixed with solvent cement complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer-in-Charge of following sizes :-
20mm bore of pipe
25mm bore of pipe
32mm bore of pipe
Dismantling of cast iron, PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engineer-in-Charge following bore of pipe :-
100/110mm dia of pipes
75mm dia of pipe
Supply & fix UPVC ultra drain,SelFit pipes, single socketed, ISI marked, IS-13592 type 'B' in any length, jointed with solvent cement fixed in walls and floors complete all as specified and directed by Engineer-in-Charge of following size :-
110mm dia of pipes
75mm dia of pipe
Supply & fix UPVC junction single 'Tee' equal with door opening, ISI marked, IS-14735, jointed with solvent cement complete all as specified and directed by Engineer-in-Charge of following size :-
110mm dia of pipes
75mm dia of pipe
Supply & fix PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed by Engineer-in-Charge of following size :-
110mm dia of pipes
75mm dia of pipe
Supply & fix PVC (SWR) bends any radius complete all as specified and directed by Engineer-in-Charge of following sizes :-
110mm dia of pipes
75mm dia of pipe
Supply & fix in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement with 75mm outlet dia complete all as specified and as directed by Engineer-in-Charge.
Disconnecting existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc capacity of tank exc 500 and n.exc 1000 ltr complete all as specified and directed by Engineer-in-Charge.
Supply & fix rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 1000 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms) complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair 20 mm bore gun metal globe / gate valve with iron wheel head screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repair grating doom 125mm dia with waste hole of PTMT (minimum weight 40 grams) complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repair PVC connection 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engineer-in-Charge.
Supply and fix in repairs soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Aluminium anodised tubular towel rail 20mm dia D Type 60cm long between flanges complete all as specified and directed by Engineer-in-Charge
Supply & fix in repairs Vitreous china wash down water closet, pedestal pattern (EWC), white, with 'P' or 'S' trap, with PVC water closet seat, black or white, closed pattern, with flat bottom and cover and mild steel chromium plated or aluminised hinging device including taking down and removal of existing old water closet with scat cover complete all as specified and directed by Engineer-in-Charge
Supply & fix in repairs for bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for size 15mm bore complete all as specified and directed by Engineer-in-Charge
Supply & fix in repairs for pillar tape ISI marked of 15mm bore swan neck ,fency type with capastan head,chromium plated scerwed down high pressure with long screwed shank and fly nuts screwed for iron pipe &fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs stop valve 15 mm dia cast chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed. complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs for brass CP mixer for mixing hot and cold water screwed down for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs for shower rose for 15 mm dia, PTMTscrewed down high pressure with long shank screwed end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix PVC connection 450mm long with check nut for wash hand basin etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs vitreous china wash basin white oval shape, angle back, size 550x400mm white, excluding taps, waste, chain and plug and porcelain stopper but including brackets complete all as specified and directed by Engineer-in-Charge.
Supply & fix vitreous bowl urinal flat back,size of 465x355x265mm white(minimum),with grating and union for discharge pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fix Urinal spreader of CP for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed by Engineer-in-Charge.
Supply & fix waste pipe of 32mm dia PVC pipe for WHB with long screwed shanks and fly nut flange end beddedd in red lead cement and other end fixed complete all as specified and as directed by Engineer-in-Charge.
Supply & fix in repairs PVC low level valveless, syphonic action type flushing cistern, low level, white, with inlet, bll valve, flaot and handle including brackets of 10 Ltr capacity.including flush pipe complete all as specified and directed by Engineer-in-Charge.
Supply & fix water closet squatting pan 'Orissa Pattern'of size 580 x 440 mm white with integral foot rest (excluding flushing cistern and flush pipe) with P' or 'S' trap complete incl connection to trap,and to flushing pipe, anti-syphonage pipe, etc. complete including making good to floor complete all as specified and directed by Engineer-in-Charge.
Supply & fix in repairs PVC corners fixed in bath rooms with screws including necessary drilling holes complete all as specified and directed by Engineer-in-Charge.
Supply and fix taking down existing water proofing tretment on RCC slab / beams with bitumen felt with out damaging structure and removing the debrise outside the MD land and M&L for plaster 10 mm thck on concrete surfaces in cement mortar 1:3 finished even and smooth using WPC @ 3% by weight of cement and preparing the surfaces to recive WPT treatment , applying a coat of bitumenm primer confirm to IS - 3384-1986 @ 0.3 Litre per sqm . providing APP modified memrane with non woven polyster reinforcement/mat ( centre core) by tourch application over primed surfaces complete all as specified and directed by Engineer-in-Charge.
Supply and fix 10 mm thick rendering for fair faces of concrete surfaces on walls in CM 1:3 with WPC and finished even and smooth without using extra cement as in roof complete all as specified and directed by Engineer-in-Charge. (WPC shall be measured and paid seprately).
Material & labour for providing cement concrete type B-0, 1:2:4 (using 12.5mm graded aggregate) as in roof kerbs, mud stops, filling in frames and the like rounded or or chamfered on edges complete all as specified and directed by Engineer-in-Charge
Taking down Chowkats or frames not exc. 1.5 Sqm each, with shutters (without taking off shutters from the frame) complete all as specified and directed by Engineer-in-Charge
Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm complete all as specified and directed by Engineer-in-Charge
Supply & fix 25x60 mm, 1.25 mm thick pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified including filling in frames with cement concrete type B0, 1:2:4 ( Using 12.5 mm graded stone aggegate) complete all as specified and directed by Engineer-in-Charge.
Supply & fix 35mm thick 2nd class hard wood factory made plain framed, paneled shutters (any number of panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veveered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-I), kiln seasoned and chemically pressure treated. complete all as specified and directed by Engineer-in-Charge.
Supply & fix 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/ Gauge etc. Size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a) complete all as specified and directed by Engineer-in-Charge.
Supply & fix solid PVC door frame of size 50mm x 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as specified and directed by Engineer-in-Charge.
Supply & fix stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed wih SS wire staples complete all as specified and directed by Engineer-in-Charge
Supply & fix 300mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cost aluminium alloycomplete all as specified and directed by Engineer-in-Charge.
Supply & fix 150mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
Supply & fix aluminium, anodised barrel tower bolt of extruded section and fixed 150mm of size complete all as specified and directed by Engineer-in-Charge.
Supply & fix aluminium, anodised 100mm size of hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge.
Supply & fix mild steel 300mm long ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new or previously untreated surfaces wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer on wooden surface complete all as specified and directed by Engineer-in-Charge.
Material & labour for aluminium window with double side hung shutter for glazing and gauging and frame with one or more rebates made out of JINDAL/ INDAL anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium beading screws, type B20 100mm long suitable handle and anodised aluminum fittings such as stay, hinges glazing with 5 mm thick tinted sheet glass and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm aperture as per drg No. CEAA/TD/133 sheet No. 1/2 and 2/2 dated 13.12.02 except fixed glazing (FG) all as specified and directed.(Tint of glass shall be approved by GE) Note :- Aluminium grill fixed under above item shall be measured and paid separately. Note : main section of aluminium shall be used 100mmx45MM with same thickness as mentioned in lieu of drg 65mm x 38mm above reffered due to less space available for fixing wire gauge shutter fixing grill complete all as specified and directed by Engineer-in-Charge
Material & labour for aluminium anodised grill of approved shape with opening in grill 66mm x 80mm (diagonally) or nearest to + 5mm made out of standard aluminium moulded section of size 4.4 mm x 7mm complete all as specified and directed by Engineer-in-Charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar including the pipe inserted in Man holes walls etc. for undermentioned drain pipes, including removal of rubbish outside MD land complete all as specified and directed by Engineer-in-Charge of following sizes :-
150mm dia
200mm dia
Material & labour for providing cement concrete 1:3:6 type C-2 bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and complete all as specified and directed by Engineer-in-Charge tested for :-
150mm dia of pipe
200mm dia of pipe
Material & labour for reinforced concrete pipes, 150 mm bore, class NP-2 laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
Material & labour for reinforced concrete pipes, 200mm bore, class NP-2 laid and jointed complete with collars complete all as specified and directed by Engineer-in-Charge.
Demolition of Brick work of stone/boulder/block masonry, built in cement mortar excluding ashlars facing dressed stone work and pre-cast concrete articles and precast concrete block walling complete all as specified and directed by Engineer-in-Charge.
Material & labour for Precast cement concrete block masonry with solid blocks exc 10cm in width Type C1 (1:3:6) (using 20mm graded stone aggregates) and setting in cement mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.
Material & labour for providing PCC 1:3:6, type C-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing precast reinforced cement concrete of type B1 (1:2:4) (using 20 mm graded stone aggregate) as in cover slabs for drain set in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge.
Material & labour for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering 15mm thick in CM 1:4 mixed with water proofing compound on PCC block masonry surfaces finished even and smooth without using extra cement as specified. (Note : Supply only WPC will be measured and paid separately) complete all as specified and directed by Engineer-in-Charge.
On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete all as specified and directed by Engineer-in-Charge.
Soakage wells of 1.2M dia x 4.50 effective depth complete all as specified and as shown on TD drawing CEAA/TD/80 sheet 1/2 and 2/2.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants,regulators, sockets etc.incl removing materials to store for kepping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified and directed by Engineer-in-Charge.
Taking down main switch/DB’s including MCB’s with board and fixture of any description and making good disturbed surface of walls etc complete all as specified and directed by Engineer-in-Charge.
Taking down old tube light fittings of any description and making good disturbed surface of walls etc complete all as specified and directed by Engineer-in-Charge.
Taking down old Exhaust Fans of any size and making good disturbed surface of walls etc complete all as specified and directed by Engineer-in-Charge (old exhaust fan to be deposited to AGE E/M Store Yard)
Taking down old serviceable geysers of capacity 25 lts and refixing in the same location with wall fasteners and making good disturbed surface of walls etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLSH cable 1100 volts grade ISI marked drawn through and including PVC conduit accessories etc including fixed to wall/ceiling including provn of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with and pressed steel terminal box powder coated of suitable size 3mm thick bakelite white/colour sheet top cover ISI marked with brass screws and cup washers for housing switches, sockets, fan regulator, etc complete all as specified and directed by Engineer-in-Charge for the following :-
One light point controlled by one, one way switch single pole piano type
One exhaust point controlled by one, one way switch single pole piano type each
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
All as per item No 82 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement switch piano flush type 230/250 Volt, 5 Amps single pole one way complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement switch socket combination multi purpose 2 in 1, 5 pin 5 Amps, flush type, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement switch socket combination 2 in 1 , 5/15 Amp, flush type, ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement ceiling rose surface bakelite 65mm x 50mm three terminal complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 triple pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 8 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement double door Sheet metal enclosures factory made DBs protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 4 ways with 200 Amp rated bus bar 415 volts powder coated complete all as specified and directed by Engineer-in-Charge.
Supply & fix isolators/MCBs of the under mentioned type and rating and fixing in DBs (DBs measured and paid for separately) complete all as specified and directed by Engineer-in-Charge for the following:
MCB TPN 415 volts 63 Amps Capacity, 10 KA
MCB SPN 240 volts 5-40 Amps Capacity, 'C' series
MCB SP 240 volts 6-40 Amps Capacity, 'C' series
MCB SPN 240 volts 63 Amps Capacity, 10 KA
Material & labour for earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 4 mm dia by means of nut, bolts, check nuts and washers of galvanised iron or steel as shown in electrical plate No.3 of SSR Part-I (2009) complete all as specified and directed including testing on completion including the material and labour of the following : - (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
Supply and Fixing in repairs wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 18 W 4 ft indoor decorative with 2 Core copper wire freom ceiling rose to light fitting as per complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 10 W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting complete all as specified and directed by Engineer-in-Charge.
Supply and Fix Metal body exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ Alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of Metal body exhaust fan, AC single phase 230/240V of size 450 mm sweep with louvers including making hole of suitable size/ Alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply and fixing including testing of storage type Water Heater/Geyser of vertical type of capacity 25 Ltr, Rated 2000W,230V, 50Hz Auto cutoff with a High tech adjustable thermostat,multifuction saftey valve,Magnesium anode Coated heating element, Rust Proof External Body with Unique Polymer protective coated inner Tank, Red and Green indicator lamp, Suitable for highrise building Suitable for water pressure head upto 8 bars Star rating (BEE): -5 Star,High Density & thick PUF that Ensures energy efficiency and reduced electricity bills ,15 Amps heavy duty plug complete all as specified and directed by Engineer-in-Charge. Note:-The rate quoated shall be in including hanging of Geyser in wall with 2/4 nos of stainless steel fastner of suitable size no extra payment will be allowed to contractor in this regard.
Supply & fix sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through and including PVC Conduit ISI marked with accessories and 6 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engineer-in-Charge. (Note: Two runs of conductor with one run of earth wire and PVC conduit will be measured & paid as one unit)
Supply & fix sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC Conduit ISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engineer-in-Charge. (Note: Two runs of conductor with one run of earth wire and PVC conduit will be measured & paid as one unit)
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engineer-in-Charge.
Material & labour for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engineer-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x 180 x 40 mm complete all as specified and directed by Engineer-in-Charge.
Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge
Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 25 sqmm, 4.0 core complete all as specified and directed by Engineer-in-Charge
Supply & fix tubes light grade of 50 mm bore galvanised with all fitting for cable protection trenches/ wall/ on pole including necesarry clamps sets and nut & bolts complete all as specified and directed by Engineer-in-Charge
Material & labour for cutting of existing road for laying GI pipe of size 50mm incl PCC work after laying the cable in GI pipe complete all as specified and directed by Engineer-in-Charge
Supply & fix GI tubing 25 mm bore, medium grade, ISI marked, with and including all fittings such as bends, elbows, tees, short pices etc compelete to wall and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge
Cutting & screwing extg steel tubing of size 25 mm dia for alterations or additions or lengthening screw on pipe to form connector and done in position complete all as specified and directed by Engineer-in-Charge
Supply & fix Gun-metal, globe or gate valves 25mm, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
Supply, install, testing and commissioning of Servo controlled voltage stabilizer of capacity 60 KVA ( Confirming to BIS 9815:Part1 :1994) Three phase,50 Hz, Oil cooled , outdoor , copper wound, metallic body duly powder coated with lifting Hooks two nos , digital display type, relay free smooth and silent operation with 1st filling of Transformer oil up to level having complete all as specified and directed by Engineer-in-Charge following specification:- (a) Input voltage 300V to 480 V, (b) Output voltage stabilized at any deigned/desired voltage 415V +- 1% (c) Rated frequency 50 Hz (d) No distortion in wave form (e) Response time not to exceed 10 mille seconds (f) Sensitivity (+/-)1% (g) Rate of correction 6 Volt/second for phase to phase (h) Efficiency not less than 95% (i)Type of load : Three phase,, unbalanced type (j) Digital display:- Voltmeter/Ammeter (k) Protections:- 1. Over load/Short Circuit protections 2. High/Low voltage cut off 3. By pass arrangement in case of emergency 4. Single phase sequence change protection
Supply & Laying,connecting,testing and commissioning and jointing,LT under ground cable 1100 volts grade,XLPE insulated,armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed by the Engineer-in-Charge of following Size:- Note:-Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of BOQ .
70 Sqmm 3.5 core
50 Sqmm 3.5 core
Material & labour for boring of holes under road, pavement, hard standing by necessary machine or by hand including HDPE pipe of 50 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engineer-in-Charge.
Supply & fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS FI clamps with necessary bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge.
Material & labour for Earthing complete with copper plate 60×60cm × 3.15mm thick electrode buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 20×3mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers and providing galvanised iron or steel 15 mm bore galvanised iron medium grade watering pipe, 32 mm bore galvanised iron light grade pipe for earth strip protection, including all excavation earth work in any type of strata, PCC 1:3:6 type C1 for chamber of internal size 300 mm x 300 x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete, RCC 1:2:4,type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00Kg/Sqm) with cast iron frame, funnel with wire mesh, test point etc complete all as specified and directed.all as shown in electricalplate No. 5 of SSR-2009 connected to earthing test point complete all as specified and directed by Engineer-in-Charge or indicated including testing on completion. Note: (i) Earth strip and GI protection pipe up to length 7.5m shall deemed to be included in rate of above item.
Supply & fix copper strip 20x3 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etc complete all as specified and directed by Engineer-in-Charge.
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 1.1 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed by Engineer-in-Charge.
Supply, fix and testing of ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps front operated including connection of incoming & outgoing cables complete all as specified and directed by Engineer-in-Charge
Supply & fix framed work as in door or gates of angle or other section with gusset plates rails braces etc. complete drilled for fixing of steel sheeting or other covering,Doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering running rails and guides and hanging also fastening and fixing complete AF e-290(GdeE-165 complete all as specified and directed by Engineer-in-Charge
Material & labour for mild steel plates,plain or chequered,5mm thick or over in thickness in available sizes,Fe410-W(Gde-E-250) quality-A ,including applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge
Supply, install & testing air cooled split unit Air Conditioner 100% Copper condenser & copper evaporator electric driven single Phase of capacity of 2.0 TR indoor & outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating (as per 2019 BEE rating) including MS stand for outdoor unit, suction and delivery line copper material of suitable length as per site requirement complete all as specified and directed by Engineer-in-Charge
Supply & fix Voltage stabilizer for automatic operation, wall mounted type single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with low and high cutoff facility including under and over current protection with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and directed by Engineer-in-Charge
Supply & fix double door Sheet metal enclosures factory made DBs with protection class IP-43, suitable for fixing of MCBs, Isolators etc, confirming to IS 13032 single pole and neutral 4 ways with 200 Amp rated bus bar 240 volts powder coated painted complete all as specified and directed by Engineer-in-Charge
Supply & fix metal clad enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, in hard/dense soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engineer-in-Charge.
Material & labour for providing PCC 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge.
Material & labour for reinforced cement concrete (design mix M 30) in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed by Engineer-in-Charge
Material & labour for reinforced cement concrete (design mix M 30) in Columns, pillars, piers, posts and struts complete all as specified and directed by Engineer-in-Charge
Material & labour for reinforced cement concrete (design mix M 30) in Beams, cantilevers, bressummers,lintels over 1.5m span complete all as specified and directed by Engineer-in-Charge
Material & labour for reinforced cement concrete (design mix M 30) in Chajjas complete all as specified and directed by Engineer-in-Charge
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter complete all as specified and directed by Engineer-in-Charge.
Formwork to sides of concrete columns etc for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Formwork to sides and soffits chajja of concrete etc for rough finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
Supply & fix TMT bars 6 to 8mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia complete all as specified and directed by Engineer-in-Charge.
Material & labour for Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Material & labour for 100mm thick cement concrete type D2 1:4:8 using 40mm graded stone aggregate in sub base floor complete all as specified and directed by Engineer-in-Charge.
Material & labour for Cement Concrete 1:3:6 (using 40mm graded stone aggregate), 75mm thick as in Plinth Protection/Path, etc., laid in alternate bays, finishing Concrete Surfaces Even and Smooth without using Extra Cement complete all as specified and directed by Engineer-in-Charge
Material & labour for anodised aluminium powdered coated as required colour as per site frame for doors, windows, ventilators with one or more rebates, aluminium grill and U clips, including jointing cleat for fixing etc complete all as specified and directed by Engineer-in-Charge.
Supply & fix stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix sheet glass, 5.50mm ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed by Engineer-in-Charge.
Material & labour for rendering or bedding layer 10mm thick in cement mortar 1:4 on walls, etc. for fixing tiles as skirtings, dados, etc complete all as specified and directed by Engineer-in-Charge
Material & labour for screed bed or bedding layer 15mm thick in cement mortar 1:6 for laying floor finishes/tiles complete all as specified and directed by Engineer-in-Charge.
Material & labour for vetrified ceramic tiles 10 mm thick dark shade (square/rectangular ) polished , area of each tiles not exceeding 0.36 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing new treated surfaces by washing, rubbing down and stopping and applying two coats of distemper over a coat of wall care putty complete all as specified and directed by Engineer-in-Charge.
Material & labour for 40mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregates as in Damp proof course to horizontal or vertical surfaces including necessary formwork complete all as specified and directed by Engineer-in-Charge.
Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the substructure in contact with backfill to be measured) complete all as specified and directed by Engineer-in-Charge.
Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed by Engineer-in-Charge.
Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed by Engineer-in-Charge
Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed by Engineer-in-Charge.
Supply & fix curtain rod 25mm decorated mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed by Engineer-in-Charge.
Material & labour for false ceiling of perforeted particle board/tiles 60X60 cm in size and 12mm thick fixed with nails to timber frame work or with staples on snap grid fixed with screws complete all as specified and directed by Engineer-in-Charge.
Material & labour for anodised aluminium snap grid frame work for false ceiling complete all as specified and directed by Engineer-in-Charge
Supply & fix steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed by Engineer-in-Charge.
Material & labour for Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes ,Fe 410-W (Gde-E- 250) quality- A complete all as specified and directed by Engineer-in-Charge.
Material & labour for mild steel for wind ties for roof including securing bolts ,incuding cutting tops to shape as directed , drilling holes and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
Material & labour for preperation of new or prevously untreated steel surfaces of any description over 10cm in width or girth ,not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
Supply & fix pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, curve/ circular portion on roof truss etc fixed with self tapping screws complete all as specified and directed by Engineer-in-Charge
Material & labour for 40mm thick flush shutter solid core core construction with block board and plywood face panelcommercial type on both sides and fitted to Wooden Chowkat complete all as specified and directed by Engineer-in-Charge.
Supply & fix 100 mm long butt hinges medium weight, cold rolled mild steel and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix aluminium, anodised barrel tower bolt of extruded section and fixed 200mm of size complete all as specified and directed by Engineer-in-Charge.
Material & labour for 100mm thick cement concrete type B2 1:2:4 using 40mm graded stone aggregate in sub base floor complete all as specified and directed by Engineer-in-Charge.
Supply & fix aluminium, anodised barrel tower bolt of extruded section and fixed 100mm of size complete all as specified and directed by Engineer-in-Charge.
Supply & fix 75 mm long butt hinges medium weight, cold rolled mild steel and fixed complete all as specified and directed by Engineer-in-Charge.
Supply & fix 100mm size extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
Supply & fix in Replacement recessed mounting LED 2x2 luminaire with white acrylic flat light dissipater with LED light source of 34/36 Watt of size 2’x2’(Feet) square shape suitable for False/POP ceiling including cutting the existing POP ceiling and fixing complete all as specified and as directed by Eng In Charge complete all as specified and directed by Engineer-in-Charge.
Supply & fix energy saving ceilling fan 1200mm sweep and connecting up including provision of cable from ceilling rose or connector to fan complete all as specified and directed by Engineer-in-Charge.
Supply & fix PVC body exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ Alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-Charge.
Supply & fix ceiling rose surface bakelite 65mm x 50mm three terminal complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular socket 6A 5 pin 2 in 1 combined 2 module, 240 Volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular socket 6A/16A 5 pin 2 in 1 combined 2 module, 240 Volts complete all as specified and directed by Engineer-in-Charge.
Supply & fix moodular switch 1 way 6A 1module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular switch 1 way 16A 1module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of 8 module ISI markedcomplete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of 4 module ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular white cover plate with frame of 3 module ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular metal flush box 8 module complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular metal flush box 4 module ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular metal flush box 3 module ISI marked complete all as specified and directed by Engineer-in-Charge.
Supply & fix modular metal flush box 3 module ISI marked complete all as specified and directed by Engineer-in-Charge.
Ahmed B Khatri
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .