| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC 37 1634 IMPERIAL HOUSE KALOOR KATHRIKADAVU KATHRIKADAVU ERNAKULAM KERALA 682017 | ERNAKULAM | KERALA | 682017 | ₹3.2 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹3.2 Cr+₹52,843 (0.17%)Rejected-AOC 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹3.2 Cr+₹52,843 (0.17%) | L2 | Rejected-AOC L2 |
| 3 | L3₹3.5 Cr+₹28.3 L (8.88%)Rejected-AOC 66 102 ARUN JYOTHI MULLASSERY CANAL ROAD ERNAKULAM KOCHI 682 011 | KOCHI | ERNAKULAM | KERALA | 682011 | ₹3.5 Cr+₹28.3 L (8.88%) | L3 | Rejected-AOC L3 |
| 4 | L4₹3.5 Cr+₹31.6 L (9.89%)Rejected-AOC | ₹3.5 Cr+₹31.6 L (9.89%) | L4 | Rejected-AOC L4 |
| 5 | L5₹3.8 Cr+₹59.1 L (18.5%)Rejected-AOC | ₹3.8 Cr+₹59.1 L (18.5%) | L5 | Rejected-AOC L5 |
Tender Value
₹4.3 Cr
EMD Value
₹1 L
Closing Date
29 Sept 2022, 12:00 pmClosed
Chief Executive Officer
Chief Executive Officer, Park Centre, Technopark Phase-I Campus, Thiruvananthapuram
Revamping Of 11kV Power Distribution System at Technopark Phase-I Campus, Thiruvananthapuram
2022_ETPK_504188_1
ETPK/PH-I/2022-23/E-07
Open Tender
Electrical Works
Item Rate
180 days
Technopark Phase-I Campus
Please refer Tender Document
3 documents required · 3 mandatory
₹8,850
₹1 L
Park Centre, Technopark Phase-I campus
17 Nov 2022
19 Aug 2022
30 Sept 2022
19 Aug 2022
29 Sept 2022
23 Aug 2022
23 Aug 2022
Amount
Ring Main Unit
Supply of 11kV SF6 insulated, Ring Main Unit with 630A, 21kA, 1sec both side extensible outdoor motorized RMU consists of 2nos. motorised Load break switches for Cable Entry with 1 no of vacuum Circuit Breaker for out going (+CCV+ configuration) with protection relay, battery, battery charger, SCADA compatible, indicators, hooter etc. with all accessories as per technical specification. The RMU shall have bottom cable entry from front side. FRTU shall be provided integrated with RMU completely wired along with Modem suitable for communicating with main SCADA room through OFC network. Provision of communication through GSM network shall be available. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from SCADA. FRTU shall be powered by 24V DC system with necessary protection.
Installation, testing and commissioning of 11 kV SF6 Insulated, Ring Main Unit (item no. 2) including hoisting to the respective location, assembling of units, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, pre-commissioning checks, all the tests at site as per standards etc, including suitable RCC foundation and GI sheet roofing complete work
Supply of 11kV SF6 insulated, Ring Main Unit with 630A, 21kA, 1sec both side extensible outdoor motorized RMU consists of 2nos. motorised Load break switches for Cable Entry with 2 no of vacuum Circuit Breaker for out going (+CCVV+ configuration) with protection relay, battery, battery charger, SCADA compatible, indicators, hooter etc. with all accessories as per technical specification. The RMU shall have bottom cable entry from front side. FRTU shall be provided integrated with RMU completely wired along with Modem suitable for communicating with main SCADA room through OFC network. Provision of communication through GSM network shall be available. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from SCADA. FRTU shall be powered by 24V DC system with necessary protection.
Installation, testing and commissioning of 11 kV SF6 Insulated, Ring Main Unit (item no. 3)including hoisting to the respective location, assembling of units, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, pre-commissioning checks, all the tests at site as per standards etc, including suitable RCC foundation and GI sheet roofing complete work
Supply of 11kV SF6 insulated, Ring Main Unit with 630A, 21kA, 1sec both side extensible outdoor motorized RMU consists of 2nos. motorised Load break switches for Cable Entry with 3 nos of vacuum Circuit Breaker for out going (+CCVVV+ configuration) with protection relay, battery, battery charger, SCADA compatible, indicators, hooter etc. with all accessories as per technical specification. The RMU shall have bottom cable entry from front side. FRTU shall be provided integrated with RMU completely wired along with Modem suitable for communicating with main SCADA room through OFC network. Provision of communication through GSM network shall be available. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from SCADA. FRTU shall be powered by 24V DC system with necessary protection.
Installation, testing and commissioning of 11 kV SF6 Insulated, Ring Main Unit (item no. 4)including hoisting to the respective location, assembling of units, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, pre-commissioning checks, all the tests at site as per standards etc, including suitable RCC foundation and GI sheet roofing complete work
Supply of 11kV SF6 insulated, Ring Main Unit with 630A, 21kA, 1sec both side extensible outdoor motorized RMU consists of 2nos. motorised Load break switches for Cable Entry with 4 nos of vacuum Circuit Breaker for out going (+CCVVVV+ configuration) with protection relay, battery, battery charger, SCADA compatible, indicators, hooter etc. with all accessories as per technical specification. The RMU shall have bottom cable entry from front side. FRTU shall be provided integrated with RMU completely wired along with Modem suitable for communicating with main SCADA room through OFC network. Provision of communication through GSM network shall be available. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from SCADA. FRTU shall be powered by 24V DC system with necessary protection.
Installation, testing and commissioning of 11 kV SF6 Insulated, Ring Main Unit (item no 5) including hoisting to the respective location, assembling of units, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, pre-commissioning checks, all the tests at site as per standards etc, including suitable RCC foundation and GI sheet roofing complete work
Supply of 11kV SF6 insulated, Ring Main Unit with 630A, 21kA, 1sec both side extensible outdoor motorized RMU consists of 2nos. motorised Load break switches for Cable Entry with 5 nos. of vacuum Circuit Breaker for out going (+CCVVVVV+ configuration) with protection relay, battery, battery charger, SCADA compatible, indicators, hooter etc. with all accessories as per technical specification. The RMU shall have bottom cable entry from front side. FRTU shall be provided integrated with RMU completely wired along with Modem suitable for communicating with main SCADA room through OFC network. Provision of Provision of communication through GSM network shall be available. The FRTU shall include all hardware, software and firmware necessary to meet the input/output (I/O) point requirement including input output cards and output relays. FRTU shall include on/off device control points to support control actions initiated from SCADA. FRTU shall be powered by 24V DC system with necessary protection.
Installation, testing and commissioning of 11 kV SF6 Insulated, Ring Main Unit (item no. 6) including hoisting to the respective location, assembling of units, lining up, bolting the units, checking all the control wirings, Calibration of all measuring instruments, pre-commissioning checks, all the tests at site as per standards etc, including suitable RCC foundation and GI sheet roofing complete work
Metering Cubicle
Supply and Installation of metering cubicle which shall be constructed in 2mm thick sheet steel enclosure with 7 tank pre-treatment process and be subsequently painted with polyurethane based powder painted to same colour as that of RMU. Each metering cubicle shall house 1 set of three phase PT of metering class (0.2) and 3 nos of single phase CT (0.2s class accuracy). A ToD meter with 4 quadrant metering along with communication facility (RS 485) also shall be included along with this module. The metering cubicle shall have bottom cable entry from front side.
HT Cables
Supply of following sizes of XLPE insulated non-FRLS Aluminium conductor armoured power cables of 11kV grade confirming to IS 7098 amended upto date
3Cx300sqmm
3Cx150sqmm
3Cx185sqmm
Laying of XLPE power cable of 11 kV grade of following size using Lateral thrust boring (Hortzondit Direct Drilling) of holes in all classes of soil suitable for inserting 110 mm dia HDPE Pipes to lines and levels up to a depth of 3 mts without damaging any existing underground utilities fixing 110mm dia 8Kg PN6 PE80 HDPE pipe in the bore hole made as per the direction of Technopark officials at site for drawing the following 11 kV UG Cables with out any damage as per direction of departmental officers and staff including hire charges for tools and plants, conveying and ereding machinery for the lateral thrust boring and removing the same from the site after completion of the work including loading and untoading and supply of 110mm HDPE pipe.
3Cx300sqmm
3Cx150sqmm
3Cx185sqmm
Laying of XLPE power cable of 11 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
3Cx150sqmm
3Cx185sqmm
3Cx300sqmm
3Cx400sqmm
Laying of one number XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.
3Cx150sqmm
3Cx185sqmm
3Cx300sqmm
3Cx400sqmm
Laying of one number XLPE power cable of 11 KV grade of following size in recess/surface/cable tray/wall with saddles, clamps and all other accessories as required
3Cx150sqmm
3Cx185sqmm
3Cx300sqmm
3Cx400sqmm
Supplying and laying 40mm dia HDPE PLB pipe duct with coupling collars for drawing optic fiber pilot wire through the PLB pipes as per drawing and as per direction of Technopark Officials, in the existing trench/ HDD hole already made for laying 11kV UG Cable and also for covering distance form control rooms to each RMU's
Supply, laying and commissioning of fibre optical cable (24 fibre) from cable drums and laying through the 40mm PLB HDPE pipe carefully and neatly including loops, termination,supply of suitable terminal boxes, joint enclosures and connectors etc. complete on standard specifications and directions of Technopark officers at site
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
3Cx150sqmm
3Cx185sqmm
3Cx300sqmm
3Cx400sqmm
Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor cable of 11 kV grade as required.
3Cx150sqmm
3Cx185sqmm
3Cx300sqmm
3Cx400sqmm
SCADA
Earthing and Protection
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription"11kV UG Cable", bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground at every 100m interval.
Dismanteling
Dismantling of existing feeder cables from the receiving stations without any damage in the system (work including dismatling of existing cables termination,connection, etc)g
3Cx150sqmm
3Cx185sqmm
3Cx300sqmm
Preperation of the drawing, laisioning with all statutory bodies, submitting and getting approvals from KSEI and all statutory bodies, submission of completion certificate and arranging inspections, getting sanctions and energisation certificate from KSEI etc. for commissioning the whole installation in the premises. All statutory payments will be reimbursed on production of original receipt.
Civil Works
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material
Beyond 30 cm girth upto and including 60 cm girth
Beyond 60 cm girth upto and including 120 cm girth
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Ordinary rock
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Dismantling of bituminous road manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
Fathima Engineering Co. Pvt. Ltd.
National Electric Co
Dinu Electricals
Leela Electricpower Services Pvt.Ltd
VIJAYA ELE TECHS PRIVATE LTD.
SANTHOSH ELECTRO-TECH PVT LTD
IDEAL DATACOM NETWORK AND ELECTRICAL SOLUTIONS PVT LTD
Quilon Consulting Engineers
HELSA ELECTRICALS PVT LTD
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .