| 1 | L1₹21.2 LAccepted-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹21.9 L+₹19,100 (0.88%)Rejected-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L2 | Rejected-Finance Not a Lowest Bidder | |
| 3 | L3₹22.7 L+₹99,770 (4.60%)Rejected-Finance | L3 | Rejected-Finance Not a Lowest Bidder | |
| 4 | L4₹23.1 L+₹1.4 L (6.40%)Rejected-Finance C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L4 | Rejected-Finance Not a Lowest Bidder | |
| 5 | L5₹23.5 L+₹1.8 L (8.53%)Rejected-Finance PLOT NO 52 SIDDARTH PARK BEHIND ICE FACTORY RAVALWADI BHUJ KUTCH GUJARAT 370001 | KACHCHH | GUJARAT | 370001 | L5 | Rejected-Finance Not a Lowest Bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Jan 2020, 6:00 pmClosed
GE (AF) NALIYA
GE AF Naliya 370655
REPAIR REPLACEMENT OF INTERNAL WIRING FITTINGS FIXTURES AT VARIOUS LOCATION AT AF STATION NALIYA UNDER GE AF NALIYA
2019_MES_307253_1
8670/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) NALIYA
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) NALIYA
₹60,000
Yes
30 Jan 2020
17 Dec 2019
8 Jan 2020
17 Dec 2019
6 Jan 2020
31 Dec 2019
Amount
Taking down carefully copper/ aluminum point wiring (light, fan, socket or power etc.) complete including fitting and fixture such as switches, socket, ceiling rose, pendent, regulators, light fittings, etc. complete all as specified and as directed. Note:- Job including for taking out old gutties, screw, nails, casing caping/ conduit etc. and making good to disturbed surface of wall/ floor/ ceiling etc. to match with the existing surface.
M&L for point wiring with 1.5 Sqmm, FRLS, single core, PVC insulated, unsheathed, 1100 Volts grade with multistranded copper conductor drawn through and including PVC casing and capping with all accessories fixed to wall/ floor/ ceiling etc. and including provision of 1.5 Sqmm PVC insulated and unsheathed copper conductor as earth continuity conductor and connected to common earth dolly including PVC box, ISI marked of suitable size for mounting the switches, socket outlets, fan regulators etc. complete all as specified and as directed for following:- One light/ fan point controlled by one, one way switch.
One 3 pin, 5 Amp, socket outlet on independent board.
One light point controlled by two, two way switches.
One 3 pin, 5 Amp socket outlet on the same board with other switches.
One bell/ buzzer point controlled by one push button on the same board with other switches or independent.
Descrition all as per Srl Item No. 2.10 here-in-before above but with 2.5 sqmm single core cable for one 3 pin socket outlet 15 Amps on independent switch board including 2.50 Sqmm as earth continuity conductor and connected to common earth dolly complete all as specified and as directed.
S&F in replacement of switch piano, flush type, single pole, one way, 5 Amp complete all as specified and as directed.
S&F in replacement of switch piano, flush type, single pole, two way, 5 Amp complete all as specified and as directed
S&F in replacement of ceiling rose three terminal, PVC/ Polycarbonate, isolated body, complete as specified and as directed.
S&F in replacement of switch socket combination 2 in 1, multipurpose, 3 pin, 5/ 15 Amps, flush type, controlled by one switch complete all as specified and as directed.
S&F in replacement of switch socket combination 2 in 1, 5 Amp, flush type, controlled by one switch complete all as specified and as directed.
S&F in replacement of socket outlet 2 in 1, 3/ 5 pin, 5 Amp, multi purpose, flush type complete all as specified and as directed.
S&F in replacement of MCB DB, SPN, 8 ways double door with 240 Volt, 200 Amps rated bus bar with all accessories fixed in the wall including taking out old DBs any type and capacity and making good the disturbed surface to match with the existing surface of wall complete all as specified and as directed.
Description all as per Srl Item No. 10.00 here-in-before but 4 way.
S&F in replacment of sheet metal enclosure 4 ways, double door, triple pole and neutral with 415 Volt, 200 Amps rated bus bar with all accessories fixed in the wall including taking out old DBs of any type and capacity and making good the disturbed surface to match with the existing surface of wall complete all as specified and as directed.
S&F in replacment of vertical type DB, double door, suitable for isolated neutral bar, 4 ways, IP-43 protection, door earthing, mechenical impact strength IK 08 insulated busbar assembly, fixed in the wall with suitable nuts and bolts including 4 pole MCCB 25 Amp 16 KA fixed in DBs as incommer, three phase supply fixed in the wall including taking out old DBs of any type and capacity and making good the disturbed surface to match with the existing surface of wall complete all as specified and as directed. Make:- Indoasian Cat Part No. 811870 or equivalent model & make of Legrand/Havells/Bajaj/CG or approved by GE.
S&F in replacment of isolator 4 Pole, 100 Amp, 240 Volts complete all as specified and as directed.
S&F in replacment of isolator 4 Pole, 63 Amp, 240 Volts complete all as specified and as directed.
S&F in replacement of MCB, single pole and neutral, 35-63 Amps, 240 Volts, complete all as specified and as directed.
S&F in replacement of MCB, single pole, 6 to 32 Amps, 240 Volts, complete all as specified and as directed.
S&F in replacement of switch bell push, flush type, 5 Amps, AC, 230 Volts, single pole complete all as specified and as directed.
S&F in replacement call bell, Ding Dong type, AC, 230 volts, single pole, controlled by one bell push complete all as specified and as directed.
S&F in replacement of lamp holder, PVC/ Polycarbonate type, insulated body with back plate batten/ angle type for batten fitting complete all as specified and as directed.
S&F in replacement of LED batten for LED tube light with 01 No. of LED tube 18 Watt, fixed on two Nos. of square block with twin core copper flexible wire and including taking down old type tube light fitting etc complete all as specified and as directed. Make:- Bajaj Cat Part No. BLRB 18W CW for tube and BLRB-DB 118 for Batten or equivalent model & make of Bajaj/CG/Havells/Surya or as approved by GE.
S&F in replacement of LED plastic batten with white acrylic cover 10 Watt fixed on two Nos. of square block with twin core copper flexible wire and including taking down old type tube light fitting/ holder of any type etc.complete all as specified and as directed. Make:- Bajaj Cat Part No. BCLSB 10 WH or equivalent model & make of Bajaj/CG/Havells/Surya or as approved by GE
S&F in replacement of energy efficient conventional LED bulk head fitting 10 Watt, IP 65, including twin core copper flexible wire including taking down old type fitting/ holder of any type etc. complete all as specified and as directed. Make:- Bajaj Cat Part No. BIBWP 6W LED or equivalent model & make of Bajaj/CG/Havells/Surya or as approved by GE
S&F in replacement of LED street light fitting 15 Watt with pressure die cast housing alongwith prismatic polymer carbonate diffuser and LED with secondary optic with IP 65 protection, including provision of GI pipe, light grade, of suitable size bent to the shape required, fixed in the wall with two Nos. of clamps, nuts, bolts, screws etc. and including taking down old street light fitting of etc. complete all as specified and as directed.
S&F in replacement of fan regulator, flush type, on the existing phenolic laminated sheet etc. as per requirement complete all as specified and as directed.
M&L in replacement for sub main wiring with two runs of single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS), drawn through and including PVC capping & casing not less than 25mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) as earth wire including taking down old unserviceable sub main wiring of any size with capping & casing/ conduit with all accessories complete all as specified and as directed. Note:- Two runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
M&L in replacement for sub main wiring with two runs of single core multistranded copper conductor cable, of size 4 Sqmm, PVC insulated, unsheathed, fire retardant, low smoke (FRLS), drawn through and including PVC capping & casing not less than 25mm wide with all necessary fitting and including one run single core multistranded copper conductor cable, of size 4.0 Sqmm, PVC insulated, unsheathed, fire retardant low smoke (FRLS) as earth wire including taking down old unserviceable sub main wiring of any size with capping & casing/ conduit with all accessories complete all as specified and as directed. Note:- Two runs of main cable and one run earth wire with capping & casing will be measured as one RM for payment.
S&F in replacement of modular switch, 230 volts, single pole, one way, 6 Amps, 1 module complete all as specified and as directed.
S&F in replacement of modular bell push, 230 volts, single pole, one way, 6 Amps, 1 module complete all as specified and as directed.
S&F in replacement of modular socket 2/ 3 pin, 6 Amps, 230 Volts, 2 modules complete all as specified and as directed.
S&F in replacement of modular socket 2/ 3 pin combined, 6/ 16 Amps, 230 Volts, 2 modules complete all as specified and as directed.
S&F in replacement of modular fan regulator of 120 Watt, 2 modules complete all as specified and as directed.
S&F in replacement of PVC rectangular block for mounting switches, sockets, fan regulators etc. with 3.0mm thick plastic laminated sheet cover of size 100mmx100mmx50mm deep, including taking down old unserviceable board of any type and removing the all unserviceable switches, sockets etc. complete all as specified and as directed. Note:- New switchs, sockets, switch sockets mounting on the new board will be measured and paid seprately under respective items.
S&F in replacement of PVC rectangular block for mounting switches, sockets, fan regulators etc. with 3.0mm thick plastic laminated sheet cover of size 200mmx150mmx50mm deep, including taking down old unserviceable board of any type and removing the all unserviceable switches, sockets etc. complete all as specified and as directed. Note:- New switchs, sockets, switch sockets mounting on the new board will be measured and paid seprately under respective items.
S&F in replacement of PVC rectangular block for mounting switches, sockets, fan regulators etc. with 3.0mm thick plastic laminated sheet cover of size 350mmx300mmx50mm deep, including taking down old unserviceable board of any type and removing the all unserviceable switches, sockets etc. complete all as specified and as directed. Note:- New switchs, sockets, switch sockets mounting on the new board will be measured and paid seprately under respective items.
S&F in replacement of 25mm dia rigid non metalic PVC conduit including of boxes (Junction/ terminal), all tees, bends, elbow, reducer, bell mouth tubes ends and fixture accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
S&F in replacement of LED tube 18/ 20 Watt including taking down old unserviceable LED tube from the existing fittings complete all as specified and as directed.
S&F in replacement of bipin holder suitable for 28/ 36/ 40 Watt tube light fitting complete all as specified and as directed.
S&F in replacement of electronic ballast suitable for 36/ 40 Watt fitting complete all as specified and as directed.
M&L in replacement for earthing complete with galvanized GI earth plate electrode of size 600mmx600mmx6mm, buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to galvanized earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and galvanized iron or steel, charcoal salt 15cm around the earth plate as shown in electrical plate No. 3 of SSR part-I, 20mm dia watering pipe medium grade 1.50 mtr long, GI protection pipe light grade 15mm dia from earth pit to main board including earthwork and excavation in any type of soil, refilling earth and removal of surplus soil upto 50 mtrs, PCC (1:3:6) type CI chamber, precast RCC cover 40mm thick, reinforced with 6mm dia MS bar 3 Nos. both way with handle made out of 6 mm dia MS bar and testing etc complete all as specified and as directed. Note:- (i) Length of GI protection pipe and earth lead wire shall not be less than 7.5 mtrs. (ii) On completeion, the earth resistance test to be carried out. If desired value of resistance not obtained, the earthing will be re-done at no extra cost.
Vijay Construction Co
M/s Shivji Rana Chad
Krishna Engineering
KALIKAY ENTERPRISES
NILESH SUBHASH KARALE
SHOBHIT BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .