Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹11.6 L+₹1.8 L (18.9%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹15.1 L+₹5.3 L (54.6%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹9.8 L
EMD Value
₹19,500
Closing Date
3 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) SURYALANKA
AGE (I) SURYALANKA MILITARY ENGINEER SERVICES BAPATLA -522 101
AS PER BOQ AND TENDER DOCUMENT
2021_MES_448637_1
AGE(I)/SL/8399
Open Tender
Civil Works - Water Works
Item Rate
180 days
SURYALANKA
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
AGE (I) SURYALANKA
₹19,500
Yes
13 Jul 2021
4 Jun 2021
5 Jul 2021
4 Jun 2021
3 Jul 2021
18 Jun 2021
5 Jun 2021 - 23 Jun 2021
60 days
Amount
Supply, Installing, Programming, Testing of Water Level Indicator, 24V-32V DC to 4-20mA Output Radar / Ultrasonic Sensor for continues level measurement Range Up to 8 mtrs, 230V Digital Display with FS+/-1% accuracy, including suitable size 2 core under ground cabling work for sensors at water UG sumps, including necessary fittings and accessories for mounting the sensors at the centre of the Sumps complete all as specified and as directed. Note : 2 Nos of UG Sumps are Located at Suryalanka PH, 1 Nos of UG Sump is Located at Bapatla PH. Make: VEGA / PEPPERL+ FUCHS / NIVELCO / SIEMENS EMERSON / USGC / ENDRESS+HAUSER
All as per item No.1 above but for Over Head Tank. Note: 1. The Height of the Over Head Tank is 21mtr from the Ground level. 2. The quoted rate shall inclusive of all the T&P, Ladder, Safety belts and any other tools required for installation required for the work.
M&L for Unplasticized PVC 32 mm pipes of pressure rating 10 kgf/cm2 laid in trenches complete as per site requirement all as specified and as directed.
All as per item No.3 above but for 40 mm dia pipe.
All as per item No.3 above but for 50 mm dia pipe.
S&F 90mm outer dia, ISI marked 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stabilized and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings laid in trenches or floors etc., including taking up existing unserviceable pipes complete all as specified and as directed.
All as per item No.3 above but for 63 mm dia pipe.
All as per item No.3 above but for mm dia pipe.
M&L for making suitable hole in existing 150/100mm DI/CI pipe and fixing of Iron 'D' Clamps with any ferrule size for tapping, including disconnecting the existing PVC/PPR/GI tapping pipe from PVC 110mm main pipe line by closing the old tapping with PVC dummy and reconnecting to ferrule with necessary accessories, fittings, Gaskets etc complete all as specified and directed. Note:- (i) Iron 'D' Clamp with Ferrule shall be measured and paid separately under relevant item as supply only. (ii) The quoted rate shall be inclusive of necessary earthwork excavation, returning filling etc complete.
Supply only iron 'D' Clamp made out of MS flat not less than 50mm x 5 mm for 150mm DI pipe with and including 25 mm GI socket welded to 'D' clamp with necessary gaskets, nuts and bolts for connection, including two coats of synthetic enamel paint over red oxide primer complete all as specified and directed.
All as per item No.10 above but for 'D' Clamp suitable for 100mm DI Pipe.
Excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m in wide in soft/loose soil for laying of Pipes all as specified and as directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed. Note:-The back fill shall be neatly rounded/leveled over the trench to a sufficient height to allow for settlement to the required level all as specified in clause 18.56.6(a) of SSR-2009.
S&F in repair 150mm dia sluice valve ISI Marked (IS 14846-2000), Class PN-1.6, both ends flanged with CI body, stainless steel spindle, chuck nut and iron wheel etc including provision of new nuts, bolts, washers and gasket including testing complete all as specified and directed.
S&F in repair 100mm dia sluice valve ISI Marked (IS 14846-2000), Class PN-1.6, both ends flanged with CI body, stainless steel spindle, check nut and iron wheel etc including provision of new nuts, bolts, washers and gasket including testing complete all as specified and directed.
M&L for valve chamber of size 1500mm x 1500mm x 860mm (internal dimension) suitable for 150/100 mm sluice valve with 100mm thick PCC (1:4:8) type D2 as in foundation, 200mm thick sub class 'B ' brick wall built in CM (1:6), 50mm thick coping in PCC (1:2:4) type B1, 15mm thick plastering in CM (1:4) to all internal and exposed surface including necessary excavation and earth work in soft/loose soil, MS sheet cover 4mm thick along with angle iron frame of size 40 x 40 x 5mm with locking arrangement with necessary fixing materials like hinges, nut bolts etc (valve chamber cover shall be opened in two ways) and painting to MS cover with two coats of synthetic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
G V N R CONSTRUCTIONS
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .