| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical TECHNICALLY NOT SUITABLE |
| 3 | Rejected-Technical | Rejected-Technical TECHNICALLY NOT SUITABLE |
| 4 | Rejected-Technical | Rejected-Technical TECHNICALLY NOT SUITABLE |
Tender Value
Refer Docs
Closing Date
3 Feb 2022, 3:00 pmClosed
S Sadasiva - Manager(Purchase)
HSL
Out-Sourcing of HVAC (Accommodation spaces ducting) Sheet Metal Works on 2 X DSVs VC 11190 and 11191
2022_HSL_88671_1
CD/OS/SB/01304/DUCTING - WORKS/ 11190-91/2021 date
Open Tender
Miscellaneous Services
Service
30 days
Hindustan Shipyard Limited
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
Exempted
17 Mar 2022
17 Jan 2022
4 Feb 2022
17 Jan 2022
3 Feb 2022
17 Jan 2022
Fabrication of Bulkhead fittings /Deck fittings /plenum boxes related to various sizes of ducts along with flanges, welding, paint scheme, workshop inspection, installation and welding and installation survey as per drawings to meet requirement of QAP to ensure the trunks without leakages at the joints. Material :- MS plate 3.15mm thick and above
Fabrication of MS Sheet Ducts (1.6mmthk), Plenum Boxes, welding along with flanges, paint scheme, workshop inspection, onboard installation with supports and wire mesh (grills) etc, box up of the trunks, onboard installation survey as per drawings without leakages at the joints to meet the requirement of QAP.
Fabrication and assembling of GI Ducts along with flanges, workshop inspection, onboard installation with supports ventilation outlets by providing metal framed wire mesh, ensuring the trunk joints without leakages by applying sealant, onboard installation survey as per drawings to meet the requirement of QAP.
Inline& end fittings(HSL supply) :Onboard Installation of inline fittings in way of ventilation trunks (MS/GI) installation survey of inline fittings(Volume dampers, fire dampers, Gas tight/smoke tight/ Water tight dampers, diffusers, grilles, valves, filters, punkah louvers, duct flexible, bellows etc ) as per QAP.
Spiral duct with fittings (HSL supply):- Processing, Assembling of Spiral Ducts, workshop inspection, onboard installation duct and inline fittings with deck/BHD fitting along with supports, installation survey as per drawings, ensuring the trunk joints without leakages by applying sealant to meet the requirement of QAP.
Fixing of Insulation after surface cleaning on rectangular ducts (MS/GI) with adhesive and taping with FRP cloth by applying adhesive / self-adhesive tape at joints followed by installation survey.
Description of Work / Item(s)
Removal & re fixing of MS (thickness=1.6&above)/ GI Ducts (0.8mm to 1.2mm thick).
Removal &re fixing of MS(thickness=1.6&above)/GI ducting(0.8to1.2mm) including modification to suit at site
Removal & re fixing of insulation
Removal and re fixing of spiral duct
Removal &re fixing of spiral Ducting including modification to suit at site
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .