Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹61.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹62.3 L+₹1.3 L (2.21%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹67.0 L+₹6.0 L (9.91%)Rejected-Finance NAYA BASS MAHAMANDIR JODHPUR RAJASTHAN 342006 | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹69.7 L+₹8.7 L (14.3%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹71.4 L+₹10.4 L (17.1%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹71.9 L
EMD Value
₹1.3 L
Closing Date
17 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE(AF) BHUJ
HQ CWE(AF) BHUJ KHAVADA ROAD BHUJ KUTCH
AUGMENTATION OF ELECTRIC SUPPLY AND OTHER ALLIED WORKS AT AF STN BHUJ.
2023_MES_619342_1
84216/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE(AF)BHUJ
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE(AF) BHUJ
₹1.3 L
22 Nov 2023
18 Sept 2023
19 Oct 2023
19 Sept 2023
17 Oct 2023
10 Oct 2023
19 Sept 2023 - 9 Oct 2023
Amount
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth and getting out hard and dense in soil all as specified and as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick in soil all as specified and as directed by Engr-in-Charge.
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points all as specified and as directed by Engr-in-Charge.
M&L for sand cushioning for UG cables using dry river sand; gently punning down all as directed and specified. ( Note : For measurement purpose punned thickness shall be considered)
S & F unreinforced precast concrete cable cover, class HV type 1 , flat size 300 mm x 180 mm x 40mm thick all as specified and as directed by Engr-in-Charge.
Supply and laying cable HT XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty earthed type) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm 3 core all as specified and as directed by Engr-in-Charge. (Note :- Sand cushioning, GI pipes,excavation and earth work and Cable protection cover shall be measured and paid seperately under respective items.
S& F cable jointing kit for 11 KV grade cable for indoor end termination (heat shrinkage) type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminum conductor cable of 95 Sqmm size all as specified and as directed by Engr-in-Charge.
S&F GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS FI clamps with necessary bolts, nuts and washers of sizes 100 mm bore all as specified and as directed by Engr-in-Charge.
M & L for Boring of holes under road, pavement, hard standing by necessary machine or by hand including HDPE pipe of 100 mm dia suitable for 0.4 mpa working pressure all as specified and directed by EIC.
M & L for taking out loop of existing HT cable and reroute the exsting cable and laying at new route and connect to RMU all as specified as per directed by Engr-in-Carge.
M&L for erection of Precast HT cable route / cable path indicator,made out of PCC 1:2:4 ,type B1,12.5 mm graded stone aggregates, of size 100 Cm (Height) x 12 Cm (Width) x 8 Cm (Thichness) , painted with red colour lettering synthetic paint and letters 4 inch "DANGER,HT 11 KV CABLE " to be written with black colour lettering synthetic paint and embedded in PCC block 1:3:6 type C2 (using 40mm graded aggregate) of size 15cm x 15cm x 20cm including necessary excavation for PCC block , placed at interval of every 30 M ,complete all as specified and as directed by Engr-in-Charge
M&L for Borewell earthing with the help of mechanical boring machine of 150 mm dia 30 mtr depth including supply and fix 160 mm dia (O.D),UPVC pipe 6 Kg/sqcm rating -06 mtr long with the help of suitable size clamp with nut bolt and washer -01 No ,Supply and fix 30 mtr 50 mm dia GI pipe medium grade lowering in borewell with the help of T & P having suitable hole for providing good condutivity of earthing and M & L for providing 32 X6 mm GI strip up to 7.5 mtr long complete with protected with 40 mm light grade GI tubing and connect with equipment by nut bolt and bore well earthing with the help of suitable size GI nut bolt and washer etc complete. M & L for charcoal ,dust ,salt fill in bore well for earth conductivity M&L for covering of borewell with PCC (1:2:4) typr B-1/Brick masonry pit of size 45x45x45x cm complete all as specified and give the minimum earth result below 1.0 Ohm to provide any chemical etc as required complete all as specified and dircted by Engr-in Charge. Note: (i) Earth strip and GI protection pipe up to length 7.5m shall deemed to be included in rate of above item.
Supply, install, testing and commissioning of HT 11KV, 3 Phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, Outdoor Non-Extensible Fixed Type (IP54), RMU (Ring main unit) " CCC+VVV+M"6-way comprising of 03 No 630 Amps Motorized operated Load Break Switch & 03 Nos. motorized charging fixed-type Vacuum Circuit Breaker, inside robotically welded stainless steel 304 (Non Ferrite Non Megnetic Grade) tank having min. thickness 2.5mm with IP 67 Degree of Protection and enhanced BIL of 75kVp internally to manage voltage surges. RMU should be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provisions & complete with all accessories. The RMU shall be type tested for Internal arc test of AFL 21kA/1 sec for tank as per IEC62271-200. RMU shall have on-site-repairability features such as site replacable bushing/coupling/mechanism and gas refilling at site.The earthing busbar shall be provided inside each cable compartment for soilid earthing of Cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing fail-safe protection. The unit shall include the following with all necessary standard fitting as required at site.
(A) 03 Nos Load Break Switch module consisting of following accessories : (a) 11kV, 630A Load Break Switch module and integrated earthing switch, both with full making capacity. Short time current - 21kA/3-sec, Making Capacity - 52kAp (b) Auxiliary contacts - 1NO + 1NC (c) Fault Pass Indicator - 1 No.for Incoming LBS (d) Spring-assisted snap-action mechanism driven via motor and manual operation. (e) Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live condition, Right angle boots (push on type). Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. (f) Cable covers with self Interlocking mechanism with earth switch (g) Capacitive voltage indication fixed type system as per IEC61243. (B) 03Nos.Breaker module consisting of following accessories : (a) 11kV, 630A fixed-type Vaccum Circuit Breaker module for making and breaking of fault current alongwith disconnector+Earth Switch of full making capacity. Short time current - 21KA/ 3 sec, Making Capacity - 52kAp (b) Auxiliary contacts - 1NO + 1NC (c) Stored Enegry mechanism with manual and motorized spring-charging, associated closing/tripping coils, integrated non-removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism.Interlocked Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3X). Safety interlocked to prevent access to cable termination in live-condition. (d) Right angle boots (push on type) Numerical based self-powered OC+EF Protection Relay, providing OverCurrent (min. setting 20%), Earth-Fault (min. setting: 10%)
(e) 03 Nos 25/50/1, 2.5VA epoxy insulated, Ring Core CTs for protection (Acc.Cl.5P10), installed away from bushings to prevent saturation of core. 03 Nos 100/1, 2.5VA epoxy insulated, Ring Core CTs for metering (Acc.Cl:1.0), installed away from bushings to prevent saturation of core. (f) 01 Nos Digital Multifunction meter CL:1.0 (g) Suitable site replacable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation / testing / replacement purpose. (h) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB (i) Capacitive voltage indication fixed type system. (j) Mechanical Indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged Air insulated metering module 12kV,630A. (k) Bushings outside cone interface for connection of external busbar - 1 No (l) Coupling materials OD RMU to OD Metering - 1 No (m) Single Phase potential transformer,Primary voltage: 11000V Secondary voltage: 110V,25VA, CL: 1.0, 3P - 2 Sets. (n) Space heater with thermostat control - 1 No (o) Panel illumination lamp- 1 No (p) R Y B Indication- 1 No (q) Capacitive voltage indication fixed type VPIS 9-15 kV (r) Necessay interclocking arrangement for safety and operations- 1 No. Operationg Handle for Manual Operation and one no. manometer Safety Interlocks Shall be provided as per relevant IEC/IS Standards and Manufacturers directions. Above switchgear shall confirm to all relevant IEC/IS Standards. Vacuum interrupter should be of same make as RMU. Cable bushing should be replacable at site. Minimum 5 module should accommodate in one tank to avoid multiple coupling at site. Note:-The cost of the foundation are included in the quoted rate.
All as per item No.13 here-in-above but "CC+VV+M" 4-way comprising of 02 Nos 630 Amps Motorized operated Load Break Switch & 02 Nos. motorized charging fixed-type Vacuum Circuit Breaker.
All as per item No.13 here-in-above but "CC+V+M" 3-way comprising of 03 No 630 Amps Motorized operated Load Break Switch & 02 Nos. motorized charging fixed-type Vacuum Circuit Breaker.
All as per item No.13 here-in-above but "CCC+VV+M" 5-way comprising of 03 No 630 Amps Motorized operated Load Break Switch & 02 Nos. motorized charging fixed-type Vacuum Circuit Breaker.
Supply and laying copper cable of size 2 core 2.5 sqmm including PVC rigid conduit of suitable dia with ferrule,lugs,clamp all as directed by engineer-in-charge.
Supply and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
Electricals India
Anil Builders
MUKUL ENGINEERING
ALBA AC AND REF SERVICES
M/S Anil Enterprises
Vijaypower Generators Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .