Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 CrAdmitted-Finance | ₹2.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.4 Cr+₹24.7 L (11.7%)Admitted-Finance | ₹2.4 Cr+₹24.7 L (11.7%) | L2 | Admitted-Finance |
| 3 | L3₹4.5 Cr+₹2.4 Cr (112.1%)Admitted-Finance | ₹4.5 Cr+₹2.4 Cr (112.1%) | L3 | Admitted-Finance |
| 4 | L4₹2.4 Cr+₹28.3 L (13.4%)Admitted-Finance 701 7TH FLOOR LE MERIDIEN COMMERCIAL TOWER RAISINA ROAD NEW DELHI SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | ₹2.4 Cr+₹28.3 L (13.4%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Technically Not Suitable |
| Sl No | Description | Qty | Unit | POSITIVE CONTROLS L1 | ramakrishna electrical winding works L3 | SRI SANARI ELECTRICAL AND ENGINEERING WORKS L2 | DYNATRON SERVICES PVT LTD L4 |
|---|---|---|---|---|---|---|---|
| 1.00MANDATORY SERVICES | |||||||
| 2.00MOTOR RENEWAL | |||||||
| 2.01 | 50 HZ ALTERNATOR ΠO-20-50 (20KW) | 2 | Nos. | 5,00,000 ₹10,00,000 | 4,50,000 ₹9,00,000 Lowest | 4,75,600 ₹9,51,200 | 5,50,830 ₹11,01,660 |
| 2.02 | 400 HZ ALTERNATOR ΠO-20-400 (20KW) | 2 | Nos. | 5,00,000 ₹10,00,000 | 4,50,000 ₹9,00,000 Lowest | 6,75,000 ₹13,50,000 | 6,25,650 ₹12,51,300 |
| 2.03 | SULZER COMPRESSOR - 3Π39.5 25M (85 KW) | 2 | Nos. | 4,00,000 ₹8,00,000 | 7,50,000 ₹15,00,000 | 3,85,000 ₹7,70,000 Lowest | 7,74,000 ₹15,48,000 |
| 2.04 | SPLIT A/C MOTOR- Π51 M 720M5 (19.5 KW) | 2 | Nos. | 2,00,000 ₹4,00,000 Lowest | 4,50,000 ₹9,00,000 | 2,85,000 ₹5,70,000 | 4,51,500 ₹9,03,000 |
| 2.05 | CAPSTAN MOTOR DPM-22OMI (10 KW) | 2 | Nos. | 4,50,000 ₹9,00,000 | 3,75,000 ₹7,50,000 Lowest | 4,75,000 ₹9,50,000 | 4,38,600 ₹8,77,200 |
| 2.06 | REF PLANT MOTOR Π-42M (5.7 KW) | 1 | Nos. | 1,00,000 ₹1,00,000 | 1,25,000 ₹1,25,000 | 87,500 ₹87,500 | 64,500 ₹64,500 Lowest |
| 3.00MOTOR OVERHAULING/ REPAIR | |||||||
| 3.01 | BATTERY BLOWER NO I Π 11 M 720M5 (1 KW) | 4 | Nos. | 1,50,000 ₹6,00,000 | 75,000 ₹3,00,000 | 1,85,600 ₹7,42,400 | 38,700 ₹1,54,800 Lowest |
Tender Value
Refer Docs
EMD Value
₹3.6 L
Closing Date
26 Feb 2026, 11:00 amClosed
Ms.E.S.S.Vindhya Manager (Outsource)
Mob. 9493792124
Fitment/ Overhaul/ Repair Works of Motors and Starters of an EKM Class Submarine
2026_HSL_98927_1
CD/OS.1667/Motors and Starters/EKM/2026 dated 06.02.26
Open Tender
Miscellaneous Services
Service
30 days
Hindustan Shipyard Limited
Please refer Tender documents.
15 documents required · 15 mandatory
₹0
₹3.6 L
Yes
HSL
30 Mar 2026
6 Feb 2026
26 Feb 2026
6 Feb 2026
26 Feb 2026
13 Feb 2026
12 Feb 2026
MANDATORY SERVICES
MOTOR RENEWAL
50 HZ ALTERNATOR ΠO-20-50 (20KW)
400 HZ ALTERNATOR ΠO-20-400 (20KW)
SULZER COMPRESSOR - 3Π39.5 25M (85 KW)
SPLIT A/C MOTOR- Π51 M 720M5 (19.5 KW)
CAPSTAN MOTOR DPM-22OMI (10 KW)
REF PLANT MOTOR Π-42M (5.7 KW)
MOTOR OVERHAULING/ REPAIR
BATTERY BLOWER NO I Π 11 M 720M5 (1 KW)
SONAR BLOWER NO I Π 11 M 720M5 (1 KW)
SUPPLY & EXHAUST BLOWER - Π61 M 720M5 (32.5 KW)
1-2-3 BLOWER NO 1- Π-31M72OM5 (4.4 KW)
AMK 10PC BLOWER- Π-22M72OM5 (2.9 KW)
Compt Air Purify Blower - Π-22M72OM5 (2.9 KW)
W/C BLOWER Π-11M72OM5 (1 KW)
WT BLOWER - Π-22M72OM5 (2.9 KW)
15 MBOO Π-11MШ72OM5 (0.42 KW)
COMPT BLOWER - Π-31M72OM5 (4.67 KW)
GALLEY BLOWER Π-21M72OM5 (1.9 KW)
PROVISION ROOM & GALLEY PURIFIER Π-11M72OM5 (1 KW)
35 MBOO NO 1- Π-22MШ72OM5 (0.7 KW)
10 MBOO - Π-11MШ72OM5 (0.42 KW)
STANDARD BLOWER - Π-21M72OM5 (1.9 KW)
Compartment Blower Π-21M72OM5 (1.9 KW)
Compt Air Purify Blower - Π11M72OM5 (1 KW)
STARTER RENEWAL
Starter SULZER COMPRESSOR - 3Π39.5 25M
MANDATORY SPARES
RESISTOR (P)(E)B-25-1 Kohm +-10%
RESISTOR (P)(E)(B)-25.3 Kohm+-5%
HOLDER FOR FUSE (D)(P)K-1-2
RESISTOR PE-20-1.5 Kohm +-5%OR 10%
DIODE (D)237A
BEARING BALL SKF 6307 ZZ
BEARING BALL SKF AND RHP 6309 (2 DOT) ZZ
BEARING BALL SKF/RHP 6412 ZZ
BEARING SKF 6302 ZZ
BEARING SKF 6302/EQUIVALENT ZZ
BEARING SKF 6309 ZZ
BEARING SKF 6311 ZZ
BEARING SKF 6316/EQUIVALENT ZZ
BRUSH HOLDER 12.5x25
BRUSH CARBON (E)(G)74
BRUSH (E)(G)-4 H(SH)206/16X32-1
BRUSH E(G)- 74 8X10X25
BRUSH E(G)-74 K1-3,12.5X25X40
BRUSH 10X12.5X32
BRUSH 16X25X40
BRUSH 6.5X15X20
BRUSH (E)(G)-74K 2/6.25x25x40 GR.III
BRUSH (E)(G)-74K 10x12.5x25 GR.III
BRUSH 16X25X40
BRUSH (E)(G)-74K K1-3,12.5x25x40
BRUSH CARBON (E)(G)-4E,8x10, 26x9.9x7.9mm WITH SINGLE PIG T
BRUSH CARBON (E)(G)-74 33x12.5x10
BRUSH 10X12.5X32
BRUSH (E)(G)-4 KM2-8x10x25(P)41
BRUSH (E)(G)-74 8x10x25
BRUSH 16X25X40
FUSE (P)K-45,0.15A
PUSH BUTTON
BUTTON TWO (E) 1K3 WITH RED PROTECTOR
PUSH BUTTON
FUSE P(D)C-1-6A. 380V
RELAY THERMAL TPT-133-T-22A
CURRENT SETTING OF THERMAL RELAY TRT132
FUSE (P)(D)C-1 6A 380V
FUSE (P)K-45-0.15A
RESISTOR (P)(E)B-10-3.6 Kohm +-5%
RESISTOR PE-25-2.4 Kohm +-5%
RESISTOR (P)(E)B-25-24 Ohm
RESISTOR (P)(E)B-25-2 Kohm +/-10% (P)(E)B-25-2-4K
RESISTOR (P)(E)B-25-390OHMC+-10%
RESISTOR PEB-25-4300 Ohm
RESISTOR (P)(E)B-25-510 OHM +-5%
RESISTOR (P)(E)B-25-6.2 Kohm
RESISTOR (P)(E)B-25-9.1KOHM +-5%
RESISTOR (P)(E)B-40-620-OM +-10%
DIODE (D)229A
DIODE (D)232A
DIODE (D)233
DIODE (D)237A
FUSE (P)K-45-0.5A
RESISTOR (P)(E)B-25-510,OM +/-5%
RESISTOR (P)(E)B-25-1 Kohm +-10%
RESISTOR (P)(E)B-25-0479-2 (P)(E)B-25-2 Kohm +-5%
RELAY THERMAL TPT-134-TM3-28AMPS
RELAY THERMAL TPT-114-5AMPS
RELAY THERMAL TPT-113
RELAY THERMAL TPT-121
RELAY THERMAL TPT-115-7AMPS
FUSE P(D)C-1-6A
RESISTOR (P)(E)B-3KOHM.25B +/- 5%
RESISTOR (P)(P)B35B-25BT.5.1KOHM +/- 5%
RESISTOR (P)(P)B35B-25BT.1.5KOHM +/- 5%
RESISTOR (P)(P)B35B-25BT.1.2KOHM +/- 5%
BEARING SKF 5304 ZZ
BEARING SKF 5305 ZZ
BEARING SKF 6304 ZZ
BEARING SKF 6305 ZZ
AKCC-120M
AKCC-10M
AKCC-15M
AKCC-220M
AKCC-220И
AKCC-25M
AKCC-25И
AKCC-300M
AKCC-40M
AKCC-40И
AKCC-60И
AKCC-85И
AKPO Size (0-8) Mounts
* Note: 1. L1 vendor will be established on overall L1 basis (Mandatory Services and Spares). Anticipatory services cost will not be considered for establishment of L1. 2. All the spares are to be procured from IUE/ IN approved vendors only.
Item Rate BoQ
BoQ_Ver4.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only)
NUMBER #
ANTICIPATORY SERVICES
MOTOR OVERHAULING/ REPAIR
50 HZ ALTERNATOR ΠO-20-50 (20KW)
400 HZ ALTERNATOR ΠO-20-400 (20KW)
SULZER COMPRESSOR - 3Π39.5 25M (85 KW)
SPLIT A/C MOTOR- Π51 M 720M5 (19.5 KW)
CAPSTAN MOTOR DPM-22OMI (10 KW)
REF PLANT MOTOR Π-42M (5.7 KW)
MOTOR ARMATURE REWINDING
50 HZ ALTERNATOR ΠO-20-50 (20KW)
400 HZ ALTERNATOR ΠO-20-400 (20KW)
SULZER COMPRESSOR - 3Π39.5 25M (85 KW)
SPLIT A/C MOTOR- Π51 M 720M5 (19.5 KW)
CAPSTAN MOTOR DPM-22OMI (10 KW)
REF PLANT MOTOR Π-42M (5.7 KW)
BATTERY BLOWER NO I Π 11 M 720M5 (1 KW)
SUPPLY & EXHAUST BLOWER - Π61 M 720M5 (32.5 KW)
1-2-3 BLOWER NO 1- Π-31M72OM5 (4.4 KW)
AMK 10PC BLOWER- Π-22M72OM5 (2.9 KW)
15 MBOO Π-11MШ72OM5 (0.42 KW)
GALLEY BLOWER Π-21M72OM5 (1.9 KW)
35 MBOO NO 1- Π-22MШ72OM5 (0.7 KW)
10 MBOO - Π-11MШ72OM5 (0.42 KW)
MOTOR FIELD POLE REWINDING
50 HZ ALTERNATOR ΠO-20-50 (20KW)
400 HZ ALTERNATOR ΠO-20-400 (20KW)
SULZER COMPRESSOR - 3Π39.5 25M (85 KW)
SPLIT A/C MOTOR- Π51 M 720M5 (19.5 KW)
CAPSTAN MOTOR DPM-22OMI (10 KW)
REF PLANT MOTOR Π-42M (5.7 KW)
BATTERY BLOWER NO I Π 11 M 720M5 (1 KW)
SUPPLY & EXHAUST BLOWER - Π61 M 720M5 (32.5 KW)
1-2-3 BLOWER NO 1- Π-31M72OM5 (4.4 KW)
AMK 10PC BLOWER- Π-22M72OM5 (2.9 KW)
15 MBOO Π-11MШ72OM5 (0.42 KW)
GALLEY BLOWER Π-21M72OM5 (1.9 KW)
35 MBOO NO 1- Π-22MШ72OM5 (0.7 KW)
10 MBOO - Π-11MШ72OM5 (0.42 KW)
STARTER OVERHAULING
Starter SULZER COMPRESSOR - 3Π39.5 25M
MANUFACTURING OF IMPELLER
Impeller of Π 11 M 720M5 - 3(SH)CD
Impeller of Π 61 M 720M5 - 80(SH)CD
Impeller of Π 51 M 720M5 - 56(SH)CD
Impeller of Π 22 M 720M5 - 15(SH)CD
Impeller of Π 31 M 720M5 - 30(SH)CD
Impeller of Π 21 M 720M5 - 8(SH)CD
* Note: 1. L1 vendor will be established on overall L1 basis (Mandatory Services and Spares). Anticipatory services cost will not be considered for establishment of L1. 2. All the spares are to be procured from IUE/ IN approved vendors only.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
REPAIR-WORKS-OF-MOTORS-STARTERS.rar
Tender Documents • 5.07 MB
BOQ_108498.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .