Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance AFCONS HOUSE 16 SHAH INDUSTRIAL ESTATE VEERA DESAI ROAD AZADNAGAR ANDHERI WEST MUMBAI 400 053 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400053 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance C 4 DISTRICT CENTRE SAKET NEW DELHI 110017 | NEW DELHI | NEW DELHI | DELHI | 110017 | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance 9TH FLOOR PRIMA BAY TOWER B GATE NO 5 SAKI VIHAR ROAD POWAI MUMBAI 400072 | MUMBAI | MUMBAI | MAHARASHTRA | 400072 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 12 LANDT HOUSE SHIVAJI NAGAR NORTH AMBAZARI ROAD NAGPUR MAHARASHTRA 440010 | NAGPUR | NAGPUR | MAHARASHTRA | 440010 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance ELECTRICAL DIVISION 8TH FLOOR NCC HOUSE MADHAPUR HYDERABAD 500081 | HYDERABAD | HYDERABAD | TELANGANA | 500081 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
14 Dec 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
S. Sadasiva, Manager (Outsourcing)
HSL
EXPRESSION OF INTEREST (EOI0 FOR AUGMENTATION OF INFRASTRUCTURE AND SUPPLY, INSTALLATION, TESTING AND TRIALS AND COMMISSIONING OF CRANES AND MACHINERY AT HINDUSTAN SHIPYARD LIMITED, VISAKHAPATNAM
2021_HSL_88004_1
EOI/IAFSS/COMBINED-R0
Open Tender
Miscellaneous Services
EOI
30 days
Hindustan Shipyard Limited
Please refer Tender documents.
12 documents required · 12 mandatory
₹0
Exempted
Hindustan Shipyard Limited
15 Dec 2021
11 Nov 2021
15 Dec 2021
11 Nov 2021
14 Dec 2021
22 Nov 2021
18 Nov 2021
180 days
PART A - CIVIL AND WATER SUPPLY WORKS
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with contractors own earth brought from outside in trenches, plinth, sides of foundations,open areas etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 350 kg/cum)
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-35 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).(Note: Minimum Cement content considered is 350 kg/cum) 600 mm dia piles
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in -Charge.Initial test ( Test Load 2.5 times the Safe capacity=2.5X140 T=350 Tonne capacity )
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in -Charge. Routine test (Test Load 1.5 times the Safe capacity =1.5X140 T = 210 T )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform
Supply & installation of Mill finished Aluminium Hi-Crest sheets roofing system having 1144 mm overall width and nominal 46 mm deep ribs with subtle square fluting in the six pans of nominal 175 mm c/c distance. The end rib shall be designed for anti – capillary action grooves, to avoid seepage of water through the lateral overlap & extended to allow return leg in the profile for sturdy fixing. The base material shall be 0.91 mm thick AA3104 / AA3105 Aluminum alloy coil made from virgin aluminum confirming IS-737 and temper H-18 and Fluorocarbon PVDF finish on the exposed surface of approved colour. The Aluminum Alloy manufacturer’s test certificate for the chemical and mechanical properties of aluminum shall be submitted for approval to the concerned authority prior to installation. Tolerance in thickness shall be as per IS 2676 -1981. (Please note rates are inclusive of lateral overlap & end overlap). Installation must be done by self-drilling screws of specification mentioned below along with requisite no of Aluminium alloy storm washers complete as per the direction of engineer in charge.
Providing and fixing of 2 mm thick Aluminium gutter with double side vulcanised rubber Expansion joints. Necessary down take spout with diameter up to 150 mm at required intervals & other accessories like Cover plate, end caps and welding at joints. The Girth of gutter would be up to 1200 mm. Dye Penetration test to be conducted wherever aluminium welding has been done. Drain Water Pipe not in our scope.
Flashings manufactured from aluminium alloy AA 3004(AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF finish on the exposed surface. The flashing shall be of same colour as of roof. Girth – 400mm to 600mm
Ridge -Flashings manufactured from aluminium alloy AA 3004(AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF finish on the exposed surface. The Ridge flashing shall be of same colour as of roof.Girth – 400mm to 600mm
Supply & installation of Mill finished Aluminium Hi-Crest sheets cladding system having 1144 mm overall width and nominal 46 mm deep ribs with subtle square fluting in the six pans of nominal 175 mm c/c distance. The end rib shall be designed for anti – capillary action grooves, to avoid seepage of water through the lateral overlap & extended to allow return leg in the profile for sturdy fixing. The base material shall be 0.91 mm thick AA3104 / AA3105 Aluminum alloy coil made from virgin aluminum confirming IS-737 and temper H-18 and Fluorocarbon PVDF finish on the exposed surface of approved colour. The Aluminum Alloy manufacturer’s test certificate for the chemical and mechanical properties of aluminum shall be submitted for approval to the concerned authority prior to installation. Tolerance in thickness shall be as per IS 2676 -1981. (Please note rates are inclusive of lateral overlap & end overlap). Installation must be done by self-drilling screws of manufacturer specification along with requisite no of Aluminium alloy storm washers complete as per the direction of engineer in charge.
Providing and Fixing of 2 mm thick profiled Polycarbonate Panels for skylight roofing and cladding includung all accessories and making the joints water tight all complete as per manufacturer recommentation and as directed by Engineer in charge.
Steel fencing with structural steel angles and plates including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. as per drawing and directed by Engineer in charge.
Supply of aluminum louvers consisting of panels manufactured from 0.6 mm thick aluminum alloy AA3005/3105, of height 132mm and 98.5 mm wide, supplied to required lengths up to a maximum of 6 mtrs, to be installed at a panel module of 136.5 mm by means of aluminum brackets. The brackets belonging to the system, 20 - 25 mm wide, made of extruded aluminum, black anodized to 20 microns shall be fixed to the sub structure at a centre to centre of 136.5 mm as required and panels clipped on. Clamps shall be fixed at 150 mm from panel edges and maximum center-to-center spacing of 920mm all properties and specifications shall comply with ECCA directives and more specifically EN 1396:1996. Paint Finish: Panel shall be stove enamelled and finished with special three layered coating system (consisting of first a conversion layer of thickness 800-2000mg/sq mtr, a polyurethane basecoat of 16-20 microns, and a special top coat of polyamide particles of 8- 12 microns thick to provide excellent abrasion and damage resistance) in a continuous coil coating process of the approved colour on the exposed side and thereverse side with epoxy.
RCC Flooring work
RCC -20 cm thick M35 grade
PCC 10 cm thick 1:4:8
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. M.S. tube
Providing and applying Anti corrosive painting on steel work including epoxy primer (DFT-175 micron),epoxy intermediate coat (DFT-125 micron) and aliphatic PU top coat (DFT-50 micron) and surface roughness shall be made to SA 2.5 before applying primer etc. including cost and conveyance of all materials,nuts,bolts,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.
PART II- CURVED MODULE FABRICATION HALL
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with contractors own earth brought from outside in trenches, plinth, sides of foundations,open areas etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 350 kg/cum)
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-35 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: Minimum Cement content considered is 350 kg/cum) 600 mm dia piles
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge.Initial test ( Test Load 2.5 times the Safe capacity=2.5X120 T=300 Tonne capacity )
Pile capacity - 150 T
Arranging and conducting vertical load testing of piles in accordance with IS.2911 (Part IV ) including installation of loading platform and preparation of pile head or construction of test cap and dismantling of test cap after test etc complete as per specification & the direction of Engineer - in - Charge. Routine test (Test Load 1.5 times the Safe capacity =1.5X120 T = 180 T )
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Supply & installation of Mill finished Aluminium Hi-Crest sheets roofing system having 1144 mm overall width and nominal 46 mm deep ribs with subtle square fluting in the six pans of nominal 175 mm c/c distance. The end rib shall be designed for anti – capillary action grooves, to avoid seepage of water through the lateral overlap & extended to allow return leg in the profile for sturdy fixing. The base material shall be 0.91 mm thick AA3104 / AA3105 Aluminum alloy coil made from virgin aluminum confirming IS-737 and temper H-18 and Fluorocarbon PVDF finish on the exposed surface of approved colour. The Aluminum Alloy manufacturer’s test certificate for the chemical and mechanical properties of aluminum shall be submitted for approval to the concerned authority prior to installation. Tolerance in thickness shall be as per IS 2676 -1981. (Please note rates are inclusive of lateral overlap & end overlap). Installation must be done by self-drilling screws of specification mentioned below along with requisite no of Aluminium alloy storm washers complete as per the direction of engineer in charge.
Providing and fixing of 2 mm thick Aluminium gutter with double side vulcanised rubber Expansion joints. Necessary down take spout with diameter up to 150 mm at required intervals & other accessories like Cover plate, end caps and welding at joints. The Girth of gutter would be up to 1200 mm. Dye Penetration test to be conducted wherever aluminium welding has been done. Drain Water Pipe not in our scope.
Flashings manufactured from aluminium alloy AA 3004(AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF finish on the exposed surface. The flashing shall be of same colour as of roof. Girth – 400mm to 600mm
Ridge -Flashings manufactured from aluminium alloy AA 3004(AlMn1Mg1) as specified in BS EN 1396: 2007 minimum material thickness of 0.9 mm and Fluorocarbon PVDF finish on the exposed surface. The Ridge flashing shall be of same colour as of roof.Girth – 400mm to 600mm
Providing at all heights, levels and locations Aluminium profile industrial troughed sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per specifications, detail drawings and direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealent where required etc. but excluding the cost of purlins, rafters and trusses. 0.91 mm thick, the profile detail width 1044/920 mm, cover width 1000/875 mm.
Providing and Fixing of 2 mm thick profiled Polycarbonate Panels for skylight roofing and cladding includung all accessories and making the joints water tight all complete as per manufacturer recommentation and as directed by engineer in charge.
Steel fencing with structural steel angles and plates including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. as per drawing and directed by Engineer in charge.
Supply of aluminum louvers consisting of panels manufactured from 0.6 mm thick aluminum alloy AA3005/3105, of height 132mm and 98.5 mm wide, supplied to required lengths up to a maximum of 6 mtrs, to be installed at a panel module of 136.5 mm by means of aluminum brackets. The brackets belonging to the system, 20 - 25 mm wide, made of extruded aluminum, black anodized to 20 microns shall be fixed to the sub structure at a centre to centre of 136.5 mm as required and panels clipped on. Clamps shall be fixed at 150 mm from panel edges and maximum center-to-center spacing of 920mm all properties and specifications shall comply with ECCA directives and more specifically EN 1396:1996. Paint Finish: Panel shall be stove enamelled and finished with special three layered coating system (consisting of first a conversion layer of thickness 800-2000mg/sq mtr, a polyurethane basecoat of 16-20 microns, and a special top coat of polyamide particles of 8- 12 microns thick to provide excellent abrasion and damage resistance) in a continuous coil coating process of the approved colour on the exposed side and thereverse side with epoxy.
RCC Flooring work
RCC -20 cm thick M35 grade
PCC 10 cm thick 1:4:8
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. M.S. tube
Providing and applying Anti corrosive painting on steel work including epoxy primer (DFT-175 micron),epoxy intermediate coat (DFT-125 micron) and aliphatic PU top coat (DFT-50 micron) and surface roughness shall be made to SA 2.5 before applying primer etc. including cost and conveyance of all materials,nuts,bolts,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.
PART III - HUMIDITY CONTROLLED BLASTING & PAINTING BAYS
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Ordinary rock
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Filling with contractors own earth brought from outside in trenches, plinth, sides of foundations,open areas etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position machine batched and machine mixed design mix M-35 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (All works upto plinth level. (Note: Minimum Cement content considered is 350 kg/cum)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Design,vetting, material, fabrication, supply, erection, transportation, labour, supervision of Pre- Engineered superstructure and cladding as per drawing including all primary members, secondary members, roof & wall sheeting, canopy as per drawing fasteners, sealer/rope sealer, closures/filler stripes, ridge cap, flashing and trim, eave gutters and downspouts, anchor bolts, ventilators and Turbo ventilators etc. complete as per the drawing and as directed by the Engineer-in-charge with the following specification at all levels. Unless specified all work shall conform to the latest Indian Standards. Building type: Clear Span (CS) as per drawing.Building height: As per drawing Building slope: as per drawing Type of End Frame: Post & Beam Design codes- IS 800- 2007, IS 875 (Part 3 Wind load) 1987, IS 801-1975, IS 1893:2002, AWS D1.1.96,D1.1-2004 . Roofing & cladding sheet: 0.91mm aluminium Hi crest sheet & 10 mm thick muiltiwall poly carbonate sheet for day light. The rate quoted for PEB shall be inclusive of all super structure work as per drawing above the existing foundation excluding the 6mm steel plate cladding and its support structure in the Blasting area. Plinth area of the building shall be measured for payment.
RCC Flooring work
RCC -20 cm thick M35 grade
PCC 10 cm thick 1:4:8
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer. M.S. tube
Providing and applying Anti corrosive painting on steel work including epoxy primer (DFT-175 micron),epoxy intermediate coat (DFT-125 micron) and aliphatic PU top coat (DFT-50 micron) and surface roughness shall be made to SA 2.5 before applying primer etc. including cost and conveyance of all materials,nuts,bolts,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.
Supplying and fixing Vertically Lifting Fabric Hoist Up Door in Single Leaf-The Fabric Hoist-up Door will be constructed in compliance with the product standard and performance characteristic requirements of EN 13241-1. Each leaf will consist of two layers of fabric, folded on each side of the supporting intermediate beams. The fabric sections will be fastened to horizontal aluminium support beams with aluminium fastening strips.The intermediate beams will be constructed of aluminium with optimum width and thickness depending on the windload requirement. - The fabric is made of one piece heavy duty vinyl coated reinforced polyester - Fabric weight approximately 900g/m2 - Flame retardancy NFP 92507: M2 / DIN 4102 B1 - The fabric shall be attached to both sides of the intermediate beams, top beam and bottom beam with self tapping screws through corrosion resistant aluminium batten strips. -Special characteristics: Lacquered (water-dilutable), material is UV stabilized, mildew and rot -resistant - Base Fabric type 1100 dtex polyester The materials and installation shall be strictly as per technical specification and manufacturers recommendation as directed by engineer in charge at all levels.
PART III- SUBSTATION AREA STATEMENT
CIVIL WORK Substation building -2 Nos Ground Floor Area (198.75+291.41)sqm
RCC framed structure of building sizes as per drawing (No:DP 1059 DRG CL 01 1101) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
PART IV- OFFICE BUILDING
CIVIL WORK Office building G+4
RCC framed structure of building sizes as per drawing with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
PART V- FACILITATION BLOCK G+1
CIVIL WORK Facilitation block G+1
RCC framed structure of building sizes as per drawing (No:DP 1059 DRG CL 01 101) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
PART- VI - RENOVATION OF EXISTING ACCOUNTS BLOCK G+1
CIVIL WORK Renovation of Existing accounts block G+1 Renovation of Ground Floor
Renovation cost for GF including vitrified tile flooring,partition works ,false ceiling and finishing works as per drawing and specification as per DPAR 2020 published by CPWD.The rate shall include the cost of Internal water supply & sanitary works as per drawing and technical specification.
New construction of First floor
RCC framed structure of building sizes as per drawing (No:DP 1059 DRG CL 01 901) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
PART VII- CIVIL ITEMS RELATED TO MECHANICAL WORKS
CIVIL WORK Civil items related to Mechanical works Manifolds
LPG Manifold Building- RCC/Steel structure having building sizes as per drawing (No:DP 1059 DRG CL 01 601) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
CO2 Manifold 1 Building -RCC/Steel structure having building sizes as per drawing (No:DP 1059 DRG CL 01 601) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
CO2 Manifold 2 Building -RCC/Steel structure having building sizes as per drawing (No:DP 1059 DRG CL 01 601) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
Compressor shed Building- RCC/Steel structure having building sizes as per drawing (No:DP 1059 DRG CL 01 1001) with pile foundation ,Internal water supply & sanitary works and finishing schedule as per the specification of DPAR 2020 published by CPWD.
Trenches
RCC Trench of size 300x600 mm of M30 grade and 200mm wall and slab thickness
RCC Trench of size 1000x1500 mm of M30 grade and 200mm wall and slab thickness
PART VIII- SLIPWAY AND CRAIN TRACK WORKS
250 T Crane track
Demolition of slab (1.5m cutting)
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1200 mm Dia Pile (M40) land side
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-40 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: Minimum Cement content considered is 360 kg/cum). 1200 mm dia piles upto a depth of 30m from the GL.
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
1200 mm Dia Pile (M40) sea side with 8mm thk liner
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-40 of specified diameter upto pile cutoff including additional length to chip off for good concrete as per IS 2911, excluding the cost of steel reinforcement but including the cost of concrete and boring with bentonite solution/polymer and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including the barge or platform for piling in water area with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap/beam/slab).Low strain pile integrity test on all the working piles as per procedure of IS : 2911 (Part 4) Contractor shall include the method of construction in water area in the method statement. 1200 mm dia piles upto a depth of 30m from seabed.
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Providing Steel Liner 8mm thick for piling works including Fabricating and Setting out as per Detailed Drawing and as per MoRTH specification 12.22
Cross beam (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
Crane beam (1.0 x 1.2 m) (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
Slab M40 grade
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Retaining wall side (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Retaining wall front (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
A120 rails with crane rail system; shall be of the continuously supported type and shall include rail, reinforced neoprene layer, support plate, rail clamps, anchor bolts, grouting and the like and shall be designed for full crane operational and standby loading. All the rail fixtures shall be of GANTREX/GANTRAI. Measurement and payment shall be per meter and the rates shall include the complete supply, installation, etc. of rail, reinforced neoprene layer, support plate, rail clamps, anchor bolts, grouting, complete in every respect.
Slipway Works
Demolition of slab
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Slipway extension (sea side)
1200 mm Dia Pile (M40) sea side with 8mm thk liner
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-40 of specified diameter upto pile cutoff including additional length to chip off for good concrete as per IS 2911, excluding the cost of steel reinforcement but including the cost of concrete and boring with bentonite solution/polymer and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including the barge or platform for piling in water area with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap/beam/slab).Low strain pile integrity test on all the working piles as per procedure of IS : 2911 (Part 4) Contractor shall include the method of construction in water area in the method statement 1200 mm dia piles upto a depth of 30m from the seabedL.
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Providing Steel Liner 10mm thick for Curbs and 6 mm thick for Steining of Wells including Fabricating and Setting out as per Detailed Drawing and as per MoRTH specification 12.22
Slab 750 Thk (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Design, erection and dismantling of cofferdam Design, erection and dismantling of temporary twin wall cofferdam preferably using hot rolled steel sheet piles with necessary tie rods, wailing channels, other supporting structures etc as per the approved design and as detailed in the Nature of works, scope of works, procedure of works, material specifications, methodology & drawings etc including cost and conveyance of all labour, equipment, granular/sandbag filling between the twin walls, dewatering, making the area dry. The work involves also designing, vetting of the design, and submission of the approved design notes, calculations and drawings for the temporary cofferdam to HSL. The design and drawings have to be vetted, stamped, signed and dated by a Professor of CivilEngineering/Offshore Engineering Department of any IIT/ NIT. The designs shallbe in accordance with Indian standards. Depth of water at cofferdam constrcution area is 10m and approximate depth of embedment (including rock layer) of the sheet pile is 15 to 20m from seabed.
Slipway landside extension
1200 mm Dia Pile (M40) land side
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-40 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: Minimum Cement content considered is 360 kg/cum) 1200 mm dia piles upto 30m from GL.
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Pile cap (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Columns (M 40) 0.6 x 1m
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Cross beam (0.6 x 0.9 m) (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
long beam (0.6 x 0.9 m) (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers
Slab 350mm thk (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Masonary block works area
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Masonary block works area
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand)
12 mm cement plaster of mix :1:4 (1 cement: 4 fine sand)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
Boulder filling (7m height inside the retaining wall)
Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level and the like. Cement mortar 1:6 (1 cement : 6 coarse sand)
Slipway inside area strengthening
1200 mm Dia Pile (M40) land side
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-40 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, Including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: Minimum Cement content considered is 360 kg/cum) 1200 mm dia piles
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
600 mm Dia Pile (M40) land side
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of garde M-40 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: Minimum Cement content considered is 360 kg/cum)- 600 mm dia piles
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Column (0.6 x 0.6)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
Slab 750 Thk (M 40)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works above plinth level upto floor V level (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Sand filling
Coarse sand (zone III)
MS Hand rails
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S. tube
Crane stopper
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Providing and applying Anti corrosive painting on steel work including epoxy primer (DFT-175 micron),epoxy intermediate coat (DFT-125 micron) and aliphatic PU top coat (DFT-50 micron) and surface roughness shall be made to SA 2.5 before applying primer etc. including cost and conveyance of all materials,nuts,bolts,labour charges ,lead,lift etc complete as directed by Engineer in Charge at all levels.
Concrete blocks for ship launching(3m x 0.9m) M 40
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete
Trench cover (1m wide 0.2 thick)
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for :Suspended floors, roofs, landings, balconies and access platform
Megablock erection area
Demolition
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
RCC works
Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. All works upto plinth level. (Note: Minimum Cement content considered is 360 kg/cum)
Thermo - Mechanically Treated Corrosion resistant steel bars of grade Fe-500D or more.
Supply and Application of 1mm thick PU based floor topping on the existing concrete floor to provide abrasion, chemical & UV Resistant with aesthetic appearance. Application of Primer – Nitoprime 30 or equivalent a 2 component system and both the components are mixed together and applied on dried concrete surface using Epoxy roller by maintaining the coverage’s strictly as specified by the manufacturer or engineer-in-charge. Antislip grains: Sprinkling of anti-slip grains on the primed surface when it is in tacky condition. Application of Intermediate coat – Trafficguard UR150 or equivalent Intermediate Coat. It is supplied in 2 component system and both the components are mixed together and applied on dried concrete surface using Epoxy roller by maintaining the coverage’s strictly as specified by the manufacturer or engineer-in-charge on the dried surface of the primer. Application of Wearing coat – Trafficguard UR150 WC or equivalent a 2 component system and both the components are mixed together and applied on dried concrete surface using Epoxy roller by maintaining the coverages strictly as specified by the manufacturer or Engineer-in-charge.
Permanent Sheet Piling at Slipway end- Type: AU20 or equivalent Supply,driving and installation of sheet piles as per Drawings and in accordance with the Specifications, complete.All including cost of materials,driving using vibrohammer, labour, equipments, material handling & transportation charges etc. all as per decision of engineer-in-charge. Pile to be driven at a depth of 25m.
Filling of sand in cofferdam area
Coarse sand (zone III) Supply, filling and compaction of sand fill in the double sheet pile profiles as per Drawings and in accordance with the Specifications, complete.All including cost of materials, labour, equipments, material handling & transportation charges etc. all as per decision of engineer-in-charge.
PCC 1:4:8 - Total quantity requirement
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
PART IX- OTHER MISCELLANEOUS WORKS
CIVIL WORK Other Miscellanious work Underground Sump
Underground RCC Sump 560 cum
Overhead tank
RCC Over head tank upto staging height 20 m , 31 cum
Septic tank 150 users
Septic tank 150 users
Landscaping work
Landscaping work
Rain water piping for Steel buldings
External work,PVC 6kg/cm2
300mm dia
250mm dia
200mm dia
160mm dia
110mm dia
External works Exposed,PVC6kg/cm2
160mm dia
110mm idia
Strom water drain
RCC Storm water drain 1mx1m size
AM Drain protection work -2.5 m height RCC wall considered on either sides
RCC Culvert 6.0x2.5 M as per drawing
Electrcical trench outisde -1.5x1.5 m ,M 30 grade and 200mm slab and wall thickness.
Electrcical trench outisde -1.2x1.2 m ,M 30 grade and 200mm slab and wall thickness.
PART X - ANCILLARY WORKS
CIVIL WORK Ancillary Works
Steel yard development - Foundation for Crane movement
Steel yard development - Pile foundation and beams for Crane movement as per drawing. Length of crane track shall be measured for payment.
Concrete sleepers for stacking steel dimensions as per drawing
Rigid pavement (136x61 m ) for steel yard as per drawing
Road work (Rigid pavement) as per drawing
PART XI- DISMANTLING WORK
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix)
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:
Dismantling Hume pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes at site as per direction of Engineer-in-charge for all leads and lifts :Above 1500 mm and below 2000mm diameter
Description of Work / Item(s)
PART B- ELECTRICAL WORKS
SUBSTATION 2
11 Panel VCB 11kV HT Panel including 2 nos of Bus PT- Refer SLD
11kV/433V 1600kVA oil cooled indoor star delta transformer with losses confirming to IS 1180 lvl 2
MSB-2 (Proposed Panel)- Refer SLD
EOT Panel- NPH-Refer SLD
EOT Panel- CMFH-Refer SLD
Lighting Panel (NPH and CMFH) -Refer SLD
Feeder Stock Yard EOT Panel -Refer SLD
Main Welding Panel- NPH 1 and 2 -Refer SLD
Main Welding Panel CMFH -Refer SLD
Welding Panel -Refer SLD
500kVAr Thyristor based Capacitor Panels-Refer SLD
2500A Al Sandwich Busduct
1250A Al Sandwich Busduct
Supply, Termination and Laying of 3C 300sqmm 11kV XLPE insulated earthed Aluminium cable
Associated LT cabling works (Supply, Termination and Laying of 3.5C 400sqmm 1.1kV XLPE insulated Aluminium cable -5500mtr)including the cables for all LT panels
Associated Earthing(CI, 100mm dia, 4m long CI B class pipe- 8 Nos, 75x10 GI strip- 120m, 50x6 GI strip-5500m, 25x6 mm Cu strip- 200m)
Internal Electrification of Curved Module Fabrication Hall and New production Hall including 2 nos of HDB along with incomer and outgoings, including 200 nos of LED highbays and its wiring from DB etc as required complete
Supply and installation of 20kVA UPS as required complete
Lightning Protection System for NPH
Lightning Protection System for CMFH
SUBSTATION 4
Addition of HT breaker in the existing 11kV HT panel - Refer SLD
11kV/433V 1600kVA oil cooled indoor star delta transformer with losses confirming to IS 1180 lvl 2
MSB-1 Retrofitting- Refer SLD
MSB-2- Refer SLD
500kVAr Thyristor based Capacitorr Panels-Refer SLD
2500A Al Sandwich Busduct
1600A Al Sandwich Busduct
1250A Al Sandwich Busduct
Supply, Termination and Laying of 3C 300sqmm 11kV XLPE insulated earthed Aluminium cable
Associated LT cabling works (Supply, Termination and Laying of 3.5C 400sqmm 1.1kV XLPE insulated Aluminium cable -2000mtr) including the cables for all LT panels
Associated Earthing(CI, 100mm dia, 4m long CI B class pipe- 4 Nos, 75x10 GI strip- 200m, 50x6 GI strip-2000m, 25x6 mm Cu strip- 200m)
SUBSTATION 3
11kV/433V 2000kVA oil cooled indoor star delta transformer with losses confirming to IS 1180 lvl 2
MSB3 Proposed
Main Shore Connection Panel
Shore Connection Panel
Shore Auxiliary Panel
500kVAr Thyristor based Capacitorr Panels-Refer SLD
3200A Al Sandwich Busduct
1250A Al Sandwich Busduct
Supply, Termination and Laying of 3C 300sqmm 11kV XLPE insulated earthed Aluminium cable
Associated LT cabling works (Supply, Termination and Laying of 3.5C 400sqmm 1.1kV XLPE insulated Aluminium cable -1870mtr) including the cables for all LT panels
Associated Earthing(CI, 100mm dia, 4m long CI B class pipe- 4 Nos, 75x10 GI strip- 600m, 50x6 GI strip-500m)
SUBSTATION 5
6 Panel VCB 11kV HT Panel including 2 nos of Bus PT- Refer SLD
Supply, Termination and Laying of 3C 300sqmm 11kV XLPE insulated earthed Aluminium cable
Associated Earthing(CI, 100mm dia, 4m long CI B class pipe- 2 Nos, 75x10 GI strip- 200m)
SUBSTATION 6
7 Panel VCB 11kV HT Panel including 2 nos of Bus PT- Refer SLD
6 Panel VCB 3.3kV HT Panel including 2 nos of Bus PT- Refer SLD
11kV/433V 1250kVA oil cooled indoor star delta transformer with losses confirming to IS 1180 lvl 2
11kV/3.3kV 3000kVA oil cooled indoor star delta transformer with losses confirming to IS 1180 lvl 2
433/24V Delta Star Lighting Transformer
MSB-Proposed for Slipway Welding
Slipway Main Panel
Portable Welding Panel
Welding Panel
Lighting Panel
500kVAr Thyristor based Capacitorr Panels-Refer SLD
1600A Al Sandwich Busduct
1250A Al Sandwich Busduct
Supply, Termination and Laying of 3C 300sqmm 11kV XLPE insulated earthed Aluminium cable
Associated LT cabling works (Supply, Termination and Laying of 3.5C 400sqmm 1.1kV XLPE insulated Aluminium cable -13900mtr and 3.3kV 300sqmm Al -cable-550m)including the cables for all LT panels
Associated Earthing(CI, 100mm dia, 4m long CI B class pipe- 27 Nos, 75x10 GI strip- 200m, 50x6 GI strip-4200m, 25x6 GI strip-1200m 25x6 mm Cu strip- 200m)
30mtr Highmast
1010kVA DG Set with exhaust stack as per PCB Norms including fuel tank, fuel piping , control panel and all accessories as required complete
Earthing of DG set
Associated LT cabling works (Supply, Termination and Laying of 3.5C 400sqmm 1.1kV XLPE insulated Aluminium cable -5600mtr)including the cables for all LT panels
DG Synchronization Panel Modification - Refer SLD
Facilitation and Production Office
Internal Electrification of Facilitation Building ( Area-1200 sqm) including LT cabling, Distribution boards, wiring, light fixtures, earthing and all accessories as required complete
Internal Electrification of Production Office ( Area-720 sqm) including LT cabling, Distribution boards, wiring, light fixtures, earthing and all accessories as required complete
Description of Work / Item(s)
PART C- FIRE PROTECTION WORKS
FIRE PUMP HOUSE
Electric driven fire pump with motor - Horizontal, split casing, 2850 lpm at 80m head
Diesel engine drive fire pump - Horizontal, split casing, 2850 lpm at 80m head
Electric driven fire pump with motor - Vertical inline, 180 lpm at 80m head
Motor control panel for pumps
Pressure gauge for pumps
Pressure switch for pump
Butterfly valves
Non return valves
Y strainer for pumps
Flexible bellows for pumps
Air vessel
MS 'C' class piping inside pump house
YARD PIPING
150mm dia MS 'C' class underground pipe
80mm dia MS 'C' class aboveground pipe
HYDRANT ACCESSORIES
Gunmetal single headed hydrant valve with 63mm instantaneious outlets
OTHERS
Internal Fire fighting system of Office Building ( Area-4000 sqm) including fire piping, sprinklers, internal hydrants, fire detection and alarm system and all accessories as required as per NBC 2016.
Description of Work / Item(s)
PART D- MACHINERIES
COMPRESSOR AND AUXILIARY ITEMS DMSITC 1000 CFM (min)
Design, Supply, Installation Testing and Commissioning of Oil Injected Screw Compressor having capacity at 1000cfm (min) and discharge pressure at 10kg/cm2 with Air cooling etc complete as required.
Design, Supply, Installation Testing and Commissioning of Oil separator inside the compressor room inline with the air pipe line suitable for the above compressor capacity etc complete as required
Design, Supply, Installation Testing and Commissioning of Primary air receiver of 5m3(5000ltr capacity) with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Pre filter suitable for the above compressor with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Refrigerated Air Dryer suitable for the above compressor with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Post filter suitable for the above compressor flow rate with all fittings etc complete as required
340 CFM (min)
Design, Supply, Installation Testing and Commissioning of Oil Injected Screw Compressor having capacity at 340cfm (min) and discharge pressure at 10kg/cm2 with Air cooling etc complete as required.
Design, Supply, Installation Testing and Commissioning of Oil separator inside the compressor room inline with the air pipe line suitable for the above compressor capacity etc complete as required
Design, Supply, Installation Testing and Commissioning of Primary air receiver of 3m3(3000ltr capacity) with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Pre filter suitable for the above compressor with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Refrigerated Air Dryer suitable for the above compressor with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Post filter suitable for the above compressor flow rate with all fittings etc complete as required
240 CFM (min)
Design, Supply, Installation Testing and Commissioning of Oil Injected Screw Compressor having capacity at 240cfm (min) and discharge pressure at 10kg/cm2 with Air cooling etc complete as required.
Design, Supply, Installation Testing and Commissioning of Oil separator inside the compressor room inline with the air pipe line suitable for the above compressor capacity etc complete as required
Design, Supply, Installation Testing and Commissioning of Primary air receiver of 2m3(2000ltr capacity) with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Pre filter suitable for the above compressor with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Refrigerated Air Dryer suitable for the above compressor with all fittings etc complete as required
Design, Supply, Installation Testing and Commissioning of Post filter suitable for the above compressor flow rate with all fittings etc complete as required
Note : The offered rates shall be inclusives of all taxes and duties, insurances, transporatation, loading and unloading from the country of origin and India except GST.
GAS PIPING & MANIFOLD SYSTEM Oxygen gas Piping
Pipes In trenches/Undergroud area - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all fittings Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, fixing the pipe inside the trench with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required with all the structural steel supports and as per tender technical specifications.
Pipes above the ground level -Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, above the ground like on the wall/ceiling with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required with all the structural steel supports and as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-80, complete including all fittings Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard , fixing the pipe inside the trench with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports and as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-80, complete including all Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, above the ground level like on the wall/ceiling with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required with Pipe Hangers and all structural steel supports and as per tender technical specifications
Design, Supplying, installation, testing and commissioning of Ball valve for low pressure piping of 3Pc Design: Full Bore: 150#: Flanged Ends: Body/End Connectors/ Ball - CF8: Stem -SS304: Seat/Seals - PTFE: Hand Lever Operated & properly pressure tested with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc. with nuts, bolts, gaskets, washers etc. & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of Ball valve for High pressure piping of 3Pc Design: Full Bore: 300#: Flanged Ends: Body/End Connectors/ Ball - CF8: Stem -SS304: Seat/Seals - PTFE: Hand Lever Operated & properly pressure tested with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc. with nuts, bolts, gaskets, washers etc. & as per tender technical specifications.
Sub Manifold structure
Design, Supply, Installation, testing and Commissioning of Sub Manifold structure of necessary size GI pipe with necessary isolation ball valve at inlet and with 08 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 08 numbers of Oxygen valve with spindle and hand wheel stub size 25.4 mm, outlet 5/8” BSP (R.H) with SS spindle and Teflon washer & as per tender technical specifications.
Design, Supply , Installation, testing and Commissioning of Sub Manifold structure of necessary size GI pipe with necessary isolation ball valve at inlet and with 04 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 04 numbers of Oxygen valve with spindle and hand wheel stub size 25.4 mm, outlet 5/8” BSP (R.H) with SS spindle and Teflon washer & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/cm2) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required suitable for the Oxygen gas & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of oxygen pressure regulator for low pressure pipeline upto outlet pressure of 10 bar etc. complete as required suitable for the Oxygen gas & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of oxygen pressure regulator for high pressure pipeline upto outlet pressure of 20 bar etc. complete as required suitable for the Oxygen gas & as per tender technical specifications.
Compressed Air Piping
Pipes In trenches/Undergroud area- Design, Supplying, installation, testing and commissioning of G.I. Pipes complete (IS:1239 Heavy duty class) including G.I. Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to IS 1239, fixing the pipe inside the trench with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required with all the structural steel supports and as per tender technical specifications.
Pipes above the ground level -Design, Supplying, installation, testing and commissioning of G.I. Pipes complete (IS:1239 Heavy duty class) including G.I. Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to IS 1239 above ground on the wall/ceiling with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of Butterfly valve, class 300 rating, wafer type, hand lever operated, Carbon steel body, disc SS304(CF8) , with seat EPDM regular bore SS 304 ball valve with CS body, disc & properly tested with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of cast steel/cast iron dual plate non-return valve having class 300 conforming to API 594 complete with WCB body, rubber gasket, GI bolts, nuts, washers etc. as required & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of regular bore SS 304 ball valve, class 300 rating, with CS body, disc & stem union, with hard chrome plated stainless steel ball tested to proper pressure with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc. & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg/cm2) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required & as per tender technical specifications.
LPG Gas Piping
Pipes In trenches/ Underground area - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard , fixing the pipe inside the trench with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.
Pipes above the ground level - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, fixing the pipe above ground level like on the wall/ceiling with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of Ball valve of 3Pc Design: Full Bore: 150#: Flanged Ends: Body/End Connectors/ Ball - CF8: Stem -SS304: Seat/Seals - PTFE: Hand Lever Operated and tested to a pressure not less than 15 Kg/cm2 with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc. & as per tender technical specifications.
Sub Manifold structure
Design, Supply, Installation, testing and Commissioning of Sub Manifold structure of necessary size GI pipe with necessary isolation ball valve and 1/2'' flash back arrestor (FBA- 3m3/hr) at inlet and with 08 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 08 numbers of LPG valve with spindle and hand wheel stub size 25.4 mm , outlet 5/8” BSP (L.H) with SS spindle and Teflon washer & as per tender technical specifications.
Design, Supply, Installation, testing and Commissioning of Sub Manifold structure of necessary size GI pipe with necessary isolation ball valve and 1/2'' flash back arrestor (FBA- 3m3/hr) at inlet and with 04 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 04 numbers of LPG valve with spindle and hand wheel stub size 25.4 mm , outlet 5/8” BSP (L.H) with SS spindle and Teflon washer & as per tender technical specifications.
Design, Supply, Installation, Testing and Commissioning of Manifold system for LPG storage area with the following components for 61 cylinders in operation and 61 cylinders in standby (2 x 61 Nos.); SS braided Teflon hose, main header, branch pipes, isolation valves, inline filter, Safety relief valve, SS body pressure gauges, regulator, high pressure and low pressure valves, flashback arrestor, Check valves, MS legs, support structural with clamp, anchor fastener or welding, with paints, Suitable box clamp and Teflon tape and MS support with clamp with anchor fastener or welding with paints, Cylinder holding chain system, etc. for the above required as per the statutory norms and standard & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of of pressure gauge 0-200 PSI (0 - 14 Kg ) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required suitable for LPG gas & as per tender technical specifications.
Carbon Dioxide Piping
Pipes In trenches/Underground area - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, fixing the pipe inside the trench with suitable clamps, supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.
Pipes above the ground level - Design, Supplying, installation, testing and commissioning of Seamless Carbon Steel Pipes, A106 Gr B, sch-40, complete including all Fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. conforming to ASTM standard, above the ground level like on the wall/ceiling with suitable clamps, , supports and painting meeting the requirements of C5M as per ISO 12944 of required shade complete as required and clamps and jointing with Teflon tape including chase cutting and making good the walls, floors etc. wherever required, Pipe Hangers and all structural steel supports & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of Ball valve of 3Pc Design: Full Bore: 150#: Flanged Ends: Body/End Connectors/ Ball - CF8: Stem -SS304: Seat/Seals - PTFE: Hand Lever Operated and tested to a pressure not less than 15 Kg/cm2 with flanged joints or socket weld joints complete with nuts, bolts, gaskets, washers etc. & as per tender technical specifications.
Sub Manifold structure
Design, Supply, fabrication, installation, testing and commissioning of CO2 sub manifold structure of necessary size GI pipe with necessary isolation ball valve at inlet, filters/strainers, with 08 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 08 numbers of CO2 valve with spindle and hand wheel stub size 25.4 mm, outlet 5/8” BSP (R.H) with SS spindle and Teflon washer & as per tender technical specifications.
Design, Supply, fabrication, installation, testing and commissioning of CO2 sub manifold structure of necessary size GI pipe with necessary isolation ball valve at inlet, filters/strainers, with 04 numbers of (1:8) tapered threaded bush fittings coupled with blind flanged connection and 04 numbers of CO2 valve with spindle and hand wheel stub size 25.4 mm, outlet 5/8” BSP (R.H) with SS spindle and Teflon washer & as per tender technical specifications.
Design, Supply, fabrication, installation, testing and commissioning of gas filter for carbon dioxide & as per tender technical specifications.
Design, Supplying, installation, testing and commissioning of pressure gauge 0-200 PSI (0 - 14 Kg) range, 3/8" BSP bottom entry, 4" dial weather proof with stainless steel internals, siphon tube and ball valve including fittings, etc. complete as required suitable for Carbon dioxide gas & as per tender technical specifications.
Design, Supply, Installation, Testing and Commissioning of Manifold system for CO2 storage area with the following components for 14 cylinders in operation and 14 cylinders in standby (2 x 14 Nos.); SS braided Teflon hose, main header, branch pipes, isolation valves, inline filter, Safety relief valve, SS body pressure gauges, regulator, high pressure and low pressure valves, flashback arrestor, necessary gas pre-heaters, Check valves, MS legs, support structural with clamp, anchor fastener or welding, with paints, Suitable box clamp and Teflon tape and MS support with clamp with anchor fastener or welding with paints, Cylinder holding chain system, etc. for the above required as per the statutory norms and standard & as per tender technical specifications.
Design, Supply, Installation, Testing and Commissioning of Manifold system for CO2 storage area with the following components for 49 cylinders in operation and 49 cylinders in standby (2 x 49 Nos.); SS braided Teflon hose, main header, branch pipes, isolation valves, inline filter, Safety relief valve, SS body pressure gauges, regulator, high pressure and low pressure valves, flashback arrestor, necessary gas pre-heaters, Check valves, MS legs, support structural with clamp, anchor fastener or welding, with paints, Suitable box clamp and Teflon tape and MS support with clamp with anchor fastener or welding with paints, Cylinder holding chain system, etc. for the above required as per the statutory norms and standard & as per tender technical specifications.
Dissolved Acetylene (DA) Piping
Design, Supply, Installation, Testing and Commissioning of Manifold system for Acetylene storage area with the following components for 58 cylinders in operation and 58 cylinders in standby ( 2 x 58 Nos.) ; SS braided Teflon hose, main header, branch pipes, isolation valves, inline filter, Safety relief valve, SS body pressure gauges, regulator, high pressure and low pressure valves, flashback arrestor, Check valves, MS legs, support structural with clamp, anchor fastener or welding with paints, Suitable box clamp and Teflon tape and MS support with clamp with anchor fastener or welding with paints, Cylinder holding chain system, for the above required as per the statutory norms and standard & as per tender technical specifications.
VERTICAL TANK FOR STORAGE OF LIQUID OXYGEN (Minimum net capacity of 25 KL) ALONG WITH ATMOSPHERIC VAPORIZERS AND INTERCONNECTED PIPING SYSTEM FOR HSL
DESIGN, MANUFACTURE & SUPPLY OF VERTICAL TANK FOR STORAGE OF LIQUID OXYGEN (Minimum net capacity of 25 KL) ALONG WITH ATMOSPHERIC VAPORIZERS AND INTERCONNECTED PIPING SYSTEM at HSL SHIPYARD (including freight & landing charges, statutory clearances, insurance and all applicable taxes except GST, and duties in country of origin or in India etc.) to the complete satisfaction of Officer in charge/Engineer as per the technical specification attached.
INSTALLATION, TESTING & COMMISSIONING OF VERTICAL TANK FOR STORAGE OF LIQUID OXYGEN (Minimum net capacity of 25 KL) ALONG WITH ATMOSPHERIC VAPORIZERS AND INTERCONNECTED PIPING SYSTEM at HSL SHIPYARD (including freight & landing charges, statutory clearances, insurance and all applicable taxes except GST, and duties in country of origin or in India etc.) to the complete satisfaction of Officer in charge/Engineer as per the technical specification attached.
DESIGN, MANUFACTURE, SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF ONE (1) NUMBER “CNC PROFILE BENDING MACHINE ” FOR HULL SHOP BAY 4 AT HSL SHIPYARD
DESIGN, MANUFACTURE & SUPPLY OF ONE (1) NUMBER “CNC PROFILE BENDING MACHINE ” FOR HULL SHOP BAY 4 AT HSL SHIPYARD (including freight & landing charges, statutory clearances, insurance and all applicable taxes except GST etc.) as per the technical specification attached.
INSTALLATION, TESTING & COMMISSIONING OF ONE (1) NUMBER “CNC PROFILE BENDING MACHINE ” FOR HULL SHOP BAY 4 AT HSL SHIPYARD (including all applicable taxes except GST) as per the technical specification attached.
Description of Work / Item(s)
PART E- CRANE
Cost of crane and accessories 120 (60+60) T - 24M TWIN TROLLEY DG EOT CRANE Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading /unloading
Cost of spares for 120 (60+60) T - 24M TWIN TROLLEY DG EOT CRANE
Cost for Erection, Installation, commissioning, testing and handing over Charges for Crane 120 (60+60) T - 24M TWIN TROLLEY DG EOT CRANE
Crane Cost of crane and accessories 100 (50+50) T - 24M TWIN TROLLEY DG EOT CRANE Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading.
Cost of spares for 100 (50+50) T - 24M TWIN TROLLEY DG EOT CRAN4
Cost for Erection, Installation, commissioning, testing and handing over Charges for Crane 100 (50+50) T - 24M TWIN TROLLEY DG EOT CRANE
Cost of crane and accessories 10 T - 50M DG EOT CRANE Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading
Cost of spares for 10 T - 50M DG EOT CRANE
Cost for Erection, Installation, commissioning, testing and handing over Charges for Crane 10 T - 50M DG EOT CRANE
Crane Cost of crane and accessories 10 T - 24M DG EOT CRANE Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading.
Cost of spares for 10 T - 24M DG EOT CRANE
Cost for Erection, Installation, commissioning, testing and handing over Charges for Crane 10 T - 24M DG EOT CRANE
Cost of crane and accessories 15T - 45M MAGNETIC DG GANTRY CRANE Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading.
Cost of spares for accessories 15T - 45M MAGNETIC DG GANTRY CRANE
Cost for Erection, Installation, commissioning, testing and handing over Charges for Crane accessories 15T - 45M MAGNETIC DG GANTRY CRANE
Cost of 250T Capacity,87m span rail mounted gantry crane and accessories (Import supply) (USD /EUR/ JPY) (Includes cost of DDP HSL stores delivery after Custom Clearance, Local Transport from port to HSL, Transport from HSL to erection site, handling, loading/unloading, cost of spares to be supplied along with crane etc.) as per specification
Cost of 250T Capacity,87m span rail mounted gantry crane and accessories (Indigenous supply,if any) (INR) (Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading cost of spares to be supplied along with crane etc.) as per specification
Erection ,Installation, commissioning ,testing and handover including service assistance for 250T Capacity,87m span rail mounted gantry crane and accessories(USD/ EUR / JPY/ INR)
Note: Contractor to specify whether the proposed crane will be reaching HSL in assembled condition or assembly is proposed at site. If site assembly is proposed, feasibility of the same to be confirmed before quoting.
Description of Work / Item(s)
PART F- MACHINERY SYSTEM FOR BLASTING AND PAINTING BAY
Cost of Humidity controlled Blasting and painting machinery (Import supply) (Includes cost of DDP HSL stores delivery after Custom Clearance, Local Transport from port to HSL, Transport from HSL to erection site, handling, loading/unloading, cost of spares to be supplied along with Machinery etc.)
Cost of Humidity controlled Blasting and painting machinery (Indigenous supply, if any) (IN R) (Includes cost of delivery at HSL stores all inclusive, Transport from HSL to erection site, handling, loading/unloading.
Erection ,Installation, commissioning ,testing and handover including service assistance of Humidity controlled Blasting and painting machinery
NCC LIMITED
AFCONS INFRASTRUCTURE LIMITED
Larsen & Toubro Construction
ITD CEMENTATION INDIA LIMITED
ITD CEMENTATION INDIA LIMITED
AFCONS INFRASTRUCTURE LIMITED
Larsen & Toubro Construction
IRCON INTERNATIONAL LIMITED
IRCON INTERNATIONAL LIMITED
AFCONS INFRASTRUCTURE LIMITED
Larsen & Toubro Construction
ITD CEMENTATION INDIA LIMITED
ITD CEMENTATION INDIA LIMITED
Larsen & Toubro Construction
NCC LIMITED
IRCON INTERNATIONAL LIMITED
NCC LIMITED
AFCONS INFRASTRUCTURE LIMITED
ITD CEMENTATION INDIA LIMITED
IRCON INTERNATIONAL LIMITED
AFCONS INFRASTRUCTURE LIMITED
ITD CEMENTATION INDIA LIMITED
NCC LIMITED
IRCON INTERNATIONAL LIMITED
finance_97339.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .