Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.4 LAccepted-AOC WANIAWAD BHUJ KUTCH 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L1 | Accepted-AOC Being the lowest bidder | |
| 2 | L2₹46.5 L+₹2.7 L (6.09%)Rejected-Finance | L2 | Rejected-Finance Not l1 |
Tender Value
₹49.9 L
EMD Value
₹1 L
Closing Date
27 Jan 2020, 6:00 pmClosed
GE AF BHUJ
GE AF BHUJ KHAVADA ROAD AIR FORCE BHUJ KUTCHH GUJARAT STATE370001
ENERGY AUDIT AND REPAIRS TO EXTERNAL ELECTRIFICATION NETWORK LIGHTING SYSTEM EARTHING SYSTEM OF SUBSTATIONS AND MISCNALIOUS ITEMS FOR KHAVADA AND BHUJ
2019_MES_310044_1
8750/V/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE AF BHUJ
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GE AF BHUJ
₹1 L
Yes
2 Mar 2020
28 Dec 2019
31 Jan 2020
28 Dec 2019
27 Jan 2020
11 Jan 2020
Amount
ENERGY AUDIT
Deployment of manpower, instrument, tools, and all connected accessories for Carrying out electricity billing analysis ( both HT and LT) for past 12 months for purchase of bulk power supply from Gujarat Electricity Board (GEB), analyzing tariff structure / Paschim Gujarat Vij Co Ltd rules as applicable for availing incentives and providing suggestions. (a) To minimize Demand expenditure and avoid penalty / infructuous expenditures. (b) To achieve reduction in tariff bills by PF control, T & D billing, Licensee status, optimization of demand control, load factor improvement, minimization of T & D losses, harmonics and improvement of PF by better supply and demand side control. (c) Electricity billing analysis, suggesting & any other measures to achieve energy efficiency shall be carried out for following HT & LT Installations :- (1) HT -2 No (2) LT -5 No Note – (i) Rate quoted shall be included of all T&P, Transportation, boarding and lodging charges and stationery required to carry out said Energy Analysis. Area covered include restricted area hence security clearance is required. (ii) Location is scattered in different areas of Air Force staion Bhuj (within approx 15 Km). Bidders are requested to visit site location before quoting the rates.
Deployment of manpower, instrument, tools, and all connected accessories for carry out on line load survey with portable power analyser for a period of 24 hours at the 11KV incoming panels / VCBs at various MRS / sub stns. This include Checking the efficiency of transformer, its loading pattern, PF, THD, Best Efficiency point and existing losses in the system. Providing suggestions to achieve energy efficiency and energy saving of the system for the following substations/areas. (1) HT -2 No (2) LT-5 No
Deployment of manpower, instrument, tools, and all connected accessories for carry out online load survey for a period of 30 Mins at the Distribuion side of Transformers, checking efficiency of system and its loading pattern, PF, THD, existing losses in the system and to provide solution to achieve reduction in losses and to achieve energy efficiency of the system for the following substations/areas. (1) All Transformers/Substns of 100KVA or higher- 45 Nos.
Deployment of manpower, instrument, tools, and all connected accessories for Carrying out detailed study of LT motors of various capacity up to 100 HP ,assessing capacitor rating required and its location to improve PF ,evaluating potential for VFD and soft starters , conducting motor load survey , checking the efficacy of existing motors, MCC , PCC , other factors affecting motor performance and existing losses. Providing suggestion to achieve energy efficiency in motors and connected electrical system and indicate other energy saving opportunities for following motor :- (1) Pump House (i) Motors up to 100 HP: 04 Nos. (2) Pump House (i) Motors up to 50 HP: 14 Nos.
Deployment of manpower, instrument, tools, and all connected accessories for Carrying out detailed study of HVAC and refrigeration system including all connected system such as chilled water ,condensate water systems and AHU but excluding cooling tower system , conducting performance audit of existing system comparing it with the design data/reference standard. Studying the existing losses, heat gains and providing measures to reduce these. Identifying improvement options, Ozone depleting substance, energy conservation opportunities to reduce energy consumption, evaluating potential for VFD and other equipment to conserve energy, indicate any other measures of energy saving opportunities for following installations :- (1) Air Force Stn Bhuj (27 Wing) (ii) A/C Plant – 48 TR- 3Nos (iii) A/C Plant – 33 TR- 1 Nos (iv) A/C Plant – 22 TR- 2 Nos (v) A/C Plant – 26 TR- 1 Nos (vi) A/C Plant – 20 TR- 1 Nos (vii) A/C Plant – 35 TR- 1Nos
Deployment of manpower, instrument, tools, and all connected accessories for Carrying out detailed study of DG set system, conducting full load testing, performance audit of existing system comparing it with the reference standard. Calculating load factor, utilization factor, and thermal efficiency and existing losses. Studying PF correction, cooling system, engine/prime mover and alternator side management, acoustic, electrical and mechanical improvements, specific fuel consumption, load balancing, quality of power. Evaluating potential for energy efficiency by repositioning/capacity utilization etc and to indicate any other measures of energy saving for following capacities of DG sets. (1) Air Force Stn Bhuj (27 Wing) (i) DG Set up to 100 KVA -21 Nos (ii) DG Set from 100 to 200 KVA -15 Nos (iii) DG Set from 200 to 315 KVA -04 Nos (2) Air Force Stn Bhuj (308 TRU) (i) DG Set up to 100 KVA - 01 Nos (3) Junction point PH (14 Km away from BHuj AF STN) (i) DG Set from 100 to 200 KVA - 02 Nos (4) Petrol Pump Pump House (14 Km away from AF STN Bhuj) (i) DG Set up to 100 KVA - 01 Nos (5) Dhorawa Pump House (16 Km away from AF STN Bhuj) Note – (i) Necessary T & P required to conduct efficeincy and load testing will be provided by the contractor and quoted rate shall be deemed to be included for the same (i) DG Set up to 100 KVA - 01 Nos
Deployment of manpower, instrument, tools, and all connected accessories for carrying out feasibility study and providing suggestions to implement Renewable Energy Sources such as wind and solar energy/hybrid system there modalitities cost benefit analysis based on payback period based on concept of net present value, carring out survay of 15KW solar power plant and giving suggestion for improvement, alternation for making it servisibel and submit detailed report based on site survey at AF Station Bhuj Note:-(Applicable for Item No 01 to 07) The complete work of Energy Audit shall be done by BEE accredited energy auditor and the firm should be enlisted in MES D(VII) category of energy audit. Contractor will submit report of energy audit containing data, analysis covering payback period etc in three hard copies and one soft copy.
M & L for taking down old unservisible compressor by duly disconnecting existing electrical connection , disconnecting suction and delivery line etc. and replacement of new Scroll compressor capacity 12 TR of Model SZ185 for air/ witer cooled chiller having package AC plant including connecting up with all electrical connection and suction and delivery connection, welding, brazing, Qty 15 Kg, R 407C refrigerant gas charging , testing etc all as specified and directed. Make: Sanyo / Copland / Danfoss / Emerson / Panasonic Note: Contractor shall provide written warranty obtained from manufacturer. 2. Old Unservisible item shall be deposited to MES store Yard.
M & L for taking down old unservisible compressor by duly disconnecting existing electrical connection , disconnecting suction and delivery line etc. and replacement of new Scroll compressor capacity 12 TR of Model SM185 for air/ witer cooled chiller having package AC plant including connecting up with all electrical connection and suction and delivery connection, welding, brazing, Qty 15 Kg, R 22 refrigerant gas charging , testing etc all as specified and directed. Make: Sanyo / Copland / Danfoss / Emerson / Panasonic Note: Contractor shall provide written warranty obtained from manufacturer. 2. Old Unservisible item shall be deposited to MES store Yard.
Supply and fix in replacement Electronic wall mounting type suitable for AC upto 1.5 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 4.0 KVA(Make: Unistar/ Microtek/ V Guard)/Volino/Vintek. Old Unservisible item shall be deposited to MES store Yard.
Supply and fix in replacement Electronic wall mounting type suitable for AC upto 2.0 TR Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volt to 250 volt with output voltage stabilized at 230 volt with accuracy of ±2.5% and of capacity 5.0 KVA(Make: Unistar/V Guard)/Volino/Vintek 1. Old Unservisible item shall be deposited to MES store Yard.
Excavation in trenches n.exc. 1.5 mtr wide and n.exc. 1.5 mtr in depth and getting out hard and dense in soil & Stone
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc. 25 cm thick in soil
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points.
Supply,spreading and filling of clean river sand spreading leveling in layers not exceeding 25 cm thick as cushioning to LT UG cable complete all as directed by Engineer-in-Charge. (NOTE : Punned thickness of dry sand will be measured and paid)
Supplying and laying un-reinforced precast concrete cable covers,class LV type-2,flat of size 300 mm x 180 mm x40mm ,cover embossed "LT CABLE" laid abutting each other with a gap not more than 10 mm ,in such a way that length of cover shall be perpendicular to length of cable complete all as specified and as directed by the Engineer-in-Charge.
Taking out unserviceable LT cables from excavated trenches, ducts, wall, pole etc including removing cable covers, sand, cable joints, pipes, clamps etc, taking out old serviceable cables, cable covers, etc for reuse and removing unserviceable cables, covers etc, for the following sizes of cables :-
LT cables up to 35 Sqmm, any core.
LT cables 185 Sqmm, any core.
LT cables 240 Sqmm, any core.
Supply & Fix in replacement,connecting,testing and commissioning and jointing,LT under ground cable 1100 volts grade,XLPE insulated,armoured with galvanized round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminum conductor, laid in trenches,ducts,fixed on poles/walls with proper size saddles and clamp laid under roads /path /drain /culverts or encased in GI pipe fixed & testing and commissioning complete all as specified and as directed by the Engineer-in-Charge of following Sizes:- Note:- (i) Sand cushioning, Cable protection cover, GI pipes, excavation and earth work shall be measured and paid for separately under respective items of Schedule "A" .
LT cables 25 Sqmm, 3.5 core.
LT cables 35 Sqmm, 3.5 core.
LT cables 185 Sqmm, 3.5 core.
LT cables 240 Sqmm, 3.5 core.
M&L for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing (Make :- M seal/3M /Denson) complete for : -
Cable size 240 Sqmm, 3.5 core
Cable size 150 to 185 Sqmm , 3.5 core
Cable size 120 Sqmm , 3.5 core
Cable size upto 10 to 50 Sqmm, 3.5 core
Taking down U/S panels & Supply, fabricate, test and commissioning, installation with cable new lugs incoming and outgoing of LT electrical outdoor distribution panel board floor mounted cubical type dust proof, weather proof, vermin proof, astehically desiggned, having at least IP-54 degree of ingress protection, fabricated from 3mm thick CRCA sheet with front and rear opening including bus bar chamber, continuous GI strip earth bus bar 4 strips of copper bus bar 200 Amps capacity, insulated color sleeves, procelain/epoxy insulators, rail channels cable alloy, danger notice board including made out of 14 gauge MS sheet over angle iron frame of size 40 x 40 x 6mm, 30 cm grouted in ground floor and 30 cm above GL including necessary excavation, foundation, PCC etc complete with locking arrangement duly powder coated painted of approved color connecting incoming & outgoing cable connection with suitable lugs, nuts, bolts, washers and cable joints, prewired complete with PVC insulated fire retardant copper conductor cable complete including:- (i) MCCB 4 POLE 415 V 100 (25 KA) adjustable type- 01 No (Incoming) (ii) MCCB 3 POLE 415 V 63 (16 KA) adjustable type-2 Nos (O/G) (iii) Isolator 3 POLE 415 V 32 Amps -01 No (iv) MCB SP 6 to 32 A (10 KA) -01 No (v) Indicator lamp neon type - 3 Nos (vi) DOL starter suitable for 7.5HP relay range 20-32A, 415Volts 3 Phase, relay range 20-32 with single phase preventer Make : Power system & controls/electro control systems India Pvt Ltd/Unique Engineer.
Supply and fix in replacement of Off-load changover switch of capacity 400 Amps having copper busbar, changover facility of side handle in sheet enclosure, 415V AC, 50 Hz including making new lugs of incoming and outgoing cable of any size all as directed by engineer in charge. Make :- Havells/ ABB/ Standerd/ L& T
Supply and fix in replacement of On-load change over switch 415V in sheet metal enclosures 4 pole of capacity 250 Amps of including making new lugs of incoming and outgoing cable of any size all as directed by engineer in charge. Make :- Havells/ ABB/ Standerd/ L& T
Supply & Fix in replacement of Automatic / Manual with inbuilt controller, Time delay Transfer Switch (ATS) 100 Amps four pole (with Enclosure) with connections of Auto / Manual Transfer Switch including Testing. including making new lugs of incoming and outgoing cable of any size all all as directed by engineer in charge. Make :- Havells/ ABB/ Standerd/L& T
Supply & Fix in replacement of Automatic / Manual with inbuilt controller, Time delay Transfer Switch (ATS) 200 Amps four pole (with Enclosure) with connections of Auto / Manual Transfer Switch including Testing. including making new lugs of incoming and outgoing cable of any size all all as directed by engineer in charge. Make :- Havells/ ABB/ Standerd/L& T
Supply & Fix in replacement of Automatic / Manual with inbuilt controller, Time delay Transfer Switch (ATS) 400 Amps four pole (with Enclosure) with connections of Auto / Manual Transfer Switch including Testing. including making new lugs of incoming and outgoing cable of any size all all as directed by engineer in charge. Make :- Havells/ ABB/ Standerd/L& T
LIGHTING SYSTEM
Supply & fix in replacement of 150W MH flood by LED flood light-High Lumen output fitting of 100 Watt ,IK 07 exclusive die-cast aluminium body with highpower LEDs as light source,LED module CCT 5700K, 240V, 50Hz, current 660mA P.F>.95 ITHD<1% with exclusive innivative designed, long life versatile pressure die cast aluminium IP65 flood light luminaire with high power LED as light source fixed with suitable GI clamps along with 10 Amps MCB and connecting wires fron syntex box to LED lights all as directed by engineer in charge. Make: -Bajaj / Havells / Crompton / Phillips / Wipro
Supply & fix in replacement of Flame proof LED light-High Lumen output fitting of 39/40 Watt with exclusive innovative designed, long life versatile pressure die cast aluminium IP65 flood light luminaire with high power LED as light source complete all as specified and directed by Engineer-in-Charge. (Make - Sudhir cat No FL/2C/1251-39W lamp voltage or equivalent of Shyam / Balinga / Bajaj)
Supply and fix in Replacement for flame proof and weather proof (Protection Class IP-65) enclosure suitable for LED tube light fitting including LED Light 2X40 watt,with LED & Driver, internal reflector, and Integral type fittings aluminium cast alloy LM-6,inside and outside light grey epoxy coating,prewired complete with connector block etc.all accessories fixed on on wall or on ceiling and connecting up complete with 23/0.0076 flexible three core copper cable in flexible steel conduict with flame proof cable glands all as specified and directed. Make: Crompton Greaves, Sudhir Switchgears Ltd., BALIGA, FCG.
EARTHING SYSTEM
M&L for earthing complete with Copper Earth plate electrode 60cmx60cm x 3.00 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including COPPER strip of 20x3mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete. Note:- Test certificate shall be submitted duly signed by the Engineer-in-Charge and user. If the earth resistance found more than 1 Ohm, earthing shall be regenerated without any extra cost till the desired earth resistance is obtained Copper plat shall be errected in earth pit in presence of user. Test report shall be submitted duly signed by the user. Copper strip beyond 7.5m long shall be measured & paid seprately. Plate will be jointed strip by brazing method.
S&F in replacement aluminium strip by copper strip 20 x 3 mm with saddles and fixing screws etc for roof/down conductor above ground on wall / PCC pole upto height 11 meter and on building wall of height 15 meter including jointing with rivets/ brazing/ insulators of cerimac/ rubber / PVC etc all as directed by engineer-in-charge complete.
S&F in replacement aluminium strip by copper strip 25 x 3 mm with saddles and fixing screws etc for roof/down conductor above ground on wall / PCC pole upto height 11 meter and on building wall of height 15 meter including jointing with rivets/ brazing/ insulators of cerimac/ rubber / PVC etc all as directed by engineer-in-charge complete.
S&F in replacement aluminium strip by copper strip 32X6 mm with saddles and fixing screws etc for roof/down conductor above ground including jointing with rivets/ brazing etc all as directed by engineer-in-charge complete.
S&F test point terminal block made of gun metal / phosphorus bronze/copper of size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head screw all as specified and directed.
S & F air termination single pointed Copper rod 12mm dia ,300mm complete all as directed.
S & F GI tubing light grade for mechanical protection of earth strip for lightning protection & by means of MS clamps with necessary bolts, nuts and washers etc complete all as specified of size 40 mm bore
S & F GI tubing medium grade for mechanical protection of earth strip / installation of LED flood Light / cable protection & by means of MS clamps with necessary bolts, nuts and washers etc complete all as specified of size 50 mm bore
M&L for PCC 1:2:4, type B1, using 20mm graded crushed stone aggregate as in bed block coping cells etc. all as specified for Feeder pillars
M&L Cleanig, dressing and levelling of sand of earthing top surface by removing or adding extra soil and making new earth chamber size 400* 400* 300 mm made up of PCC 1:3:6 type C1 chamber, with precast slab cover 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame all as specified and as directed by Enger-in-charge
M & L for cutting Ductile iron pipe of 100mm dia and supply and installing flanged ends cast iron gate valve of 100 mm for controlling the water flow along with all fittings such as flanges/ Tee/ elbow /tail piece/ socket / reducer/ rubber washer and rejointing the Ductile pipe along with providing water connection for 50 mm dia GI pipe as original all as directed by Enger-in-charge
Jyoti Refrigeration
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .