Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹35.5 L+₹4.9 L (16.1%)Rejected-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L2 | Rejected-Finance Other then lowest | |
| 3 | L3₹44.9 L+₹14.3 L (46.8%)Rejected-Finance | L3 | Rejected-Finance Other then lowest | |
| 4 | L4₹46.7 L+₹16.1 L (52.6%)Rejected-Finance | L4 | Rejected-Finance Other then lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
30 Jan 2020, 6:00 pmClosed
Maj Saikat De
GE (I) Navy Porbandar Tija Mile Porbandar
PROVN OF COMPRESSOR CHAMBER, ARMOURY AND RIFLE RACKS, ADDITION / ALTERATION TO COMCEN AND SITE DEVELOPEMENT AT INS PORBANDAR
2020_MES_311344_1
9003/PBR/E8
Open Tender
Miscellaneous Services
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (I) Navy
₹98,000
Yes
10 Feb 2020
3 Jan 2020
31 Jan 2020
3 Jan 2020
30 Jan 2020
17 Jan 2020
3 Jan 2020 - 16 Jan 2020
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
Taking down cement or cement lime plaster on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc, Complete all as specified and directed.
Cutting opening through old stone masonry walls built in cement mortar for door, window and other openings or enlarging existing opening etc or cutting out defective masonry for underpinning including providing fixing and removing shoring cleaning and stacking stone and removing surplus to store and rubbish off the premises.
Porbandar type stone masonary in cm 1:6, brought upto courses, complete all as directed by Engr-in-charge.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams,
Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
Mild steel CRS bars 8mm dia as in stirrups spacer and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Reinforced cement concrete (nominal mix) type B1, 1:2:4 for Beams, walls, cantilevers, shelves, bressummersers, lintels over 1.5m span (using 20 mm grade aggregate).
Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layers of mortars 15 mm thick for laying floor finishes in CM 1:6.
Vitrified Ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match but in skirting including 10mm thick rendering in CM 1:4 on stone masonry surfaces or surface as in backing coat plaster for skirting dados Complete all as specified and directed.
Dismantling of wall / floor and ceiling boards (fibre, pulp insulation etc) or insulation boards/ slabs / blankets any thickness including cover fillets complete all as specified and directed and providing 12 mm thick of PVC coated Gypsum designer board of size 600x600mm to be fixed on and including anodised Aluminium snap grid /section size 600mmx600mm with main runner ,cross tee and wall angle duly suspended with 4mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purlin from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed by Engineer-in-Charge.
Rendering 10 mm thick on fair face of brick work or concrete surfaces or stone masonry surfaces or surface in CM 1:6 finished even and smooth without using extra cement.
M & L for two coats of acrylic emulsion weather proof antifungal paint on newly plastered surfaces of wall or concrete surfaces in two coats including preparation of surfaces and one coat of primer complete all as specified & directed by Engr-in-charge.
Rendering 15 mm thick on fair face of brick work or concrete surfaces or stone masonry surfaces or surface in CM 1:4 finished even and smooth without using extra cement.
Preparing surface of newly plastered walls and applying two coats of oil bond distemper over chalk whitening preparatory to distempering.
Preparing surface of old plastered walls and applying one coats of oil bond distemper complete all as specified and directed.
Preparation of old painted wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint in any tint all as specified and directed
Taking down chowkats or frames not exc 1.5 Sqm each with shutter (without taking off Shutter)
Taking down chowkats or frames exc 1.5 Sqm and not. Exc 4 Sqm each with shutter (without taking off Shutter)
2nd class hardwood plain, solid straight chowkhats and frames, wrought, framed rebated on the solid,rounded or chamfered, put together with glue pinned at joints, 2nd class HW complete all as specified and directed.
Factory made 30mm thick, flush shutters, solid core construction, with block board core and plywood face panels, both face is covered with decorative choice sunmica lamination 0.9mm thick type I with lipping to match fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed.
35 mm thick 2nd class hardwood Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats, Complete all as specified and directed.
2nd class hard wood 30mm thick Glazed and skeleton shutter for windows, open rebated and prepared to receive glass , gauge etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc sizes of member of shutter as specified in SSR part-I section 8, clause 8.24 (a) supplied and fitted to chowkats etc.
Sheet glass 3mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as specified and directed.
Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers
Hydraulically aluminium extruded section body door closer regulated designation No 3 universal type suitable for door shutters of 851 to 1000mm in width and weight between 61 to 80 Kg etc complete all as specified and directed.
Mortice lock, brass body, 2 lever, vertical type, size 100 mm complete all as specified and directed.
Aluminium alloy, anodised, sliding door bolt 250mm length, with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed Complete all as specified and directed.
150mm aluminium anodised, barrel tower bolts of extruded section and fixed, Complete all as specified and directed.
150mm long aluminium handles, cast type, anodised, Complete all as specified and directed.
Butt hinges, 100 mm heavy weight, cold rolled mild steel, and fixed
Butt hinges, 50mm heavy weight, cold rolled mild steel, and fixed
Preparation of new wood and wood based surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 25mm pipe outer dia, Complete all as specified and directed.
Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified
Powder coated aluminium anodised frame for doors, windows and partitions with one or more rebates including necessary joining cleats, glazing clips, rubber neoprene packing, etc complete with powder coating of approved colour minimum thickness 50 micron complete all as specified and directed.
Glass sheet ordinary quality 5.5mm thick obscured on one side glazing with clips and aluminium beading area exc 0.5 sqm each pane etc complete all as specified and directed.
Glass sheet ordinary quality 5.5mm thick obscured on one side glazing with clips and aluminium beading area N.exc 0.5 sqm each pane etc complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping cleaning and washing down with water to remove dust etc complete all as specified and directed.
12 mm thick Prelaminated particle, board, exterior grade, Prelaminated both side with decorative choice laminations , fixed with screws to aluminium frame work, complete all as specified and as directed. (Note : Colour/Texture approved by GE)
Solid PVC sheet consisting of 5mm thick plain colour sheet including solvent cement and fixing to aluminium frame complete all as specified and directed.
M&L for PCC type D2, 1:4:8 by using 40 mm graded aggregate as in foundations, filling and mass concrete or as in sub base complete all as specified and directed.
50 mm thick fine sand bed under paver block or in foundation incl watering and consolidation all as directed by Engr-in-Charge.
PCC (1:3:6) type C1 by using 20 mm graded stone aggregate as in in roof kerbs or mud stops, rounded or chamfered on edge, complete all as specified and directed .
Surface dressing not exceeding 15 cm deep in hard and dense soil. Note:- Area of surface dressing and surface excavation are not payable simultaneously.
Hardcore of gauge n exc 63 deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface
Excavation in post holes (or similar holes) each N.exc 0.50 cum, getting out hard/dense soil, and soft/disintegrated rocks and filling in and ramming with cement concrete 1:3:6 type C-1 (20mm graded stone aggregate) complete all as specified and directed. (Note PCC shall be measured and paid separately)
M & L for cement concrete, 1:3:6, type C-1, using (20mm graded stone aggregate) as in lintels upto 1.50m clear span, cills, steps; seismic and other similar bands,plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed including necessary form work complete.
S & F roof truss (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beams, tee, angle, channel or flat sections) including distance pieces etc. conforming to Fe-410-0 or Fe-310-0.or induction butt welded tubes confirming to IS 1161- 1979 graded ST 240 all as specified & as directed.
Use and waste of form work to edges of concrete slab, roof slabs, floor slabs, exceeding 20cm wide and sides of RCC / PCC bands and similar works in walls (horizontal or sloping) and similar work of concrete with fair finished surfaces of concrete in flat complete.
M & L for PCC 1:2:4, type B-2, using (40mm graded stone aggregate) as in foundations, filling and mass concrete.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads
Mild steel screw bolts with 16 to 20mm diameter neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 22. 5cm but n exc 30cm long
S & F Pre-painted aluminium -zinc coated GI based steel sheeting (Galvalume) of approved colour, 0.50mm thick having tensile strength 550 Mpa , TCT corrugated roof sheeting with ribs (Trimdec), fixed with SDF screws to steel section in purlins ,rafters etc as in roof covering complete all as per manufacturer's instruction and as specified and directed.
Material & labour for point wiring with 4 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for 15 Amps indipendent/ or AC /Geyser Point.
Excavation in trenches N. exc. 1.5 M wide and N. exc. 1.5 M in depth for foundation, etc. and getting out in hard / dense soil, complete all as directed .
Excavation in trenches N. exc. 1.5 M wide and N. exc. 1.5 M in depth for foundation, etc. and getting out in soft / disintegrated rock
Excavation in trenches N. exc. 1.5 M wide and N. exc. 1.5 M in depth for foundation, etc. and getting out in but hard rock
Use and waste of Form work to sides of concrete foundations, footings, bases of columns and plinth beams and similar work, complete all as specified and directed .
Use and waste of Form work to sides of columns, square, rectangular, complete all as specified and directed .
S&F Mild steel CRS TMT bars 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed .
RCC type M-30 (20 mm graded aggregate) as in foundations ,including rafts, footing plinth beams, bases for column etc. complete all as specified and directed.
RCC type M-30 (20 mm graded aggregate) as in Columns, pillars, piers, posts and struts etc. complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil, complete all as directed .
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/disintegrated rock, complete all as directed .
Removing excavated material as rocks exc. 50 m and N. exc. 250 M, depositing where directed at a level N. exc. 1.5 M above the starting point, complete all as specified and directed
Use and waste of Form work to sides and soffits of suspended slabs such as roof slabs, floor slabs and similar work N exc 200 mm thick (horizontal or sloping) complete all as specified and directed.
RCC type M-30 (20 mm graded aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc. complete all as specified and directed .
Use and waste for form work to chajjas including edges etc, complete all as specified and directed.
RCC type M-30 (20 mm graded aggregate) as in chajjas etc. complete all as specified and directed .
RCC type M-30 (20 mm graded aggregate) as in roof slab supported on walls, beams and columns in roofs etc. complete all as specified and directed .
M&L for Hard core of broken stone or boulders of guage n exc. 63 mm, deposited, spread and levelled in layeres n exc. 150 mm thick, watered and rammed to a true surface, as in below sub base, plinth protection and ramp complete all as specified and directed .
Moorum / red bajri filling in floors or pavings, laid in layers N. exc. 150 mm thick, spread, levelled and rammed including watering, complete all as specified and directed.
M&L for treating the top surface of filled earth with anti termite emulsion at the rate of 5 litres per square metre of surface area,complete all as specified and as directed.
M&L for treating the soil under plinth protection / ramp with anti termite emulsion at the rate of 5 litres per square metre of surface area,complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6 , type C-1 using (20mm graded stone aggregate) as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1).
Blank
18 to 22 mm thick Kota stone slab as in flooring and size not less than 550x 550 mm laid over and including 20mm thick screed bed in cement mortar (1:6), set & jointed in grey cement slurry mixed with pigment to match shade of slab complete all as specified and directed.
18 to 22 mm thick kota stone slab as in skirting, riser of steps and pillars over and including 15mm thick rendering in cement mortar (1:4) complete all as specified and directed.
Dressed porbandar stone masonary walling of squared walling in CM (1:4), as in half thick stone wall , complete all as specified and directed .
Rendering 5 mm thick on fair faces of concrete surfaces as on ceiling surface, facia and projection of slabs, finished surfaces even and smooth without using extra cement, in CM (1:3) complete all as specified and directed.
Rendering 10 mm thick on fair faces of stone masonry surfaces or concrete surfaces on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed .
Rendering 20 mm thick in two layers (15+5) ,on fair faces of stone masonry surfaces or concrete surfaces in cement mortar 1:4 finished even & smooth with out using extra cement including use of water proofing compound in outer layer, complete all as specified and directed. (Note- Water proofing compound use against this item measured and paid separately )
Supply only integral water proofing compound.
Two coat of oil bound distemper on newly plastered surfaces as on ceiling including preparation of surfaces complete all as specified and directed .
Preparation of newly plastered external wall surfaces and applying two coat of acrylic emulsion weather proof antifungal paint over a coat of apex primer , complete all specified and directed.
S&F Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
4mm thick sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified.
Aluminium deco grill 5.5 mm to 6.5mm thick with necessary channels and clips design pattern DG 104.
S & F for 35mm thick 2nd class hard wood factory made panelled door shutters, plain framed panelled (Two panel) with lock rail & panel of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The size of rail and style shall be as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated complete.
S & F 200 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 300 mm Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast-aluminium alloy and fixed
S & F 100mm butt hinges medium weight cold rolled mild steel fixed with screws or welded Complete all as specified and directed.
10 mm thick (average) screed bed in CM (1:4) in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, finished even and smooth without extra cement complete all as specified and as directed. Note:- Polymeric membrane will be measured and paid separately
M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane.
Framed work as in doors or gates of angle or other section etc. Conforming to Fe - 290 Gde-E-165, with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging; also fastening and fixing complete.
1.6mm Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required
Preparation of new steel surface of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer.
Removing excavated materials to a distance not exec. 50 mtr and deposing where directed at a level not exec 1.5 mtr above the starting point all as specified.
M & L for providing of fine dry river sand cushion in trenches for cable protection complete all as specified. NOTE: - Only compacted thickness will be measured and paid.
4mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified.
Bib taps chromium plated, fancy type with crutch or butterfly handle, screwed down for iron pipe, 15mm bore of pipe fixed in repairs, Complete all as specified and directed.
M&L PVC (SWR) floor trap, plain with grating including jointing to waste pipe in cement mortar 75mm dia.
S&F of 75mm bore PVC (SWR) pipes of pressure rate 2.5 kgs/cm2, single socketed in any length with rubber ring, joints laid in trenches or in floor complete all as specified and directed.
S&F PVC (SWR) 75mm dia bends in any radius.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 20mm pipe outer dia, Complete all as specified and directed.
S&F1000 Ltr capacity, rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position, including with lead, locking arrangement, tounge nipple for inlet, outlet connections etc. complete all as directed by Engr-in-Charge.
S&F Gun mental globe or gate valves, with iron wheeled head screwed both ends of iron pipes for 20 mm bore pipe fixed Complete all as specified and directed.
S&F ball brass valves 20mm bore,high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
M&L Cutting into existing manholes for connecting new drains 150mm bore , making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and deforming benching as required all as specified .
Supply and laying galvanised steel water tubing medium grade ISI marked screwed socketed joints complete with all tube fitting (such as bends, elbow, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches,etc.,also cutting,screwing and waste and for making forged bends on piping as required at site for following sizes:- (a) 25 mm dia
S&F Gun mental globe or gate valves, with iron wheeled head screwed both ends of iron pipes for 25 mm bore pipe fixed Complete all as specified and directed.
Excavation in trenches N. exc. 1.5 M wide and N. exc. 1.5 M in depth for foundation, etc. and getting out in soft / loose soil, complete all as directed .
Supply and Laying in trenches or fixing on wall, floor etc LT, PVC/XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area of 4 core 35 Sqmm size after taking down the existing cable complete all as specified.
machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade, finished with grey cement and no pigment complete all as specified and directed by Engineer - in - Charge.
Rendering 10 mm thick in CM (1:4) on vertical surface complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of white wash. ,complete all as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc.
Taking down Sub main wiring complete from batten/steel conduit including making good the disturbed surfaces.
Taking down Ceiling fan complete with washer , hinge,nuts ,bolt and deposited in AGE E/M yard and re-hanging after completion of work with neccessory arrangement.all as directed by Enge-in-charge.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for the following :-
(a) One light/ fan point controlled by one one way switch
(b) One 5 Amps 3/5 pin socket outlet on same board with other switches.
(c) One 5 Amps 3/6 pin socket outlet on independent board
Material & labour for point wiring with 2.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed for Description a for independent switch socket outlet 6 pin 5/15 Amps and all as directed at site.
Sub main wiring complete with two runs 4 sq. mm single core multistranded PVC insulated unsheathed cable of 1100 volts FR grade, confirm to IS with copper conductor drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories with One run of 2.5 Sqmm PVC insulated single stranded copper earth continuity conductor all as specified.
Sub main wiring concealed with 6 Sqmm (Nominal area) with two runs of single core cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, confirm to IS with copper conductor drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories including 4 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as Specified and directed by Engr-in-Charge.
Sub main wiring concealed with 10 sqmm (Nominal area) with two runs of single core cable PVC insulated FR multistrand unsheathed copper conductor cable including 1100 V grade, drawn through Conduit including 6 sqmm (nominal area) single core PVC insulated multistrand unsheathed copper conductor as earth wire and duly connected to all common earth point all as directed.
Switch piano flush type 15/16 A single pole one way 230 V
Socket Outlet 2 in 1 3/6 pin 5and15 Amp flush type 230 V
Switch piano flush type 5/6 Amps single pole one way 230 Volts
Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volts
Switch socket combination 2 in 1, 3 pin, 5 Amp flush type universal.
Switch socket combination 2 in 1, 3 pin, 15 Amp flush type universal.
Ceiling rose surface Bakelite, 65x50mm ,3 terminals complete all as specified and directed.
Stepped type electronic fan regulator flush type on the existing sheet for 1200 /1400 mm sweep fans complete.
S & F Sheet metal enclosure DB ,Single pole and neutral with 200 Amps rated bus bar,230 volts double door type including connecting all connections of wire to MCBs with proper lugs & arrangements, making good to the disturbed surface after taking down existing DB all as specified and directed for DB 4 way
MCB TPN, 415 volts, 63 amps of breaking capacity 10 KA C curve.
MCB SP 240 Volts AC 6 - 40 Amps of breaking capacity 10 KA C curve. Make : Legrand, Havells or equivalent
MCB , DB sheet metal enclosures SPN 8 way double door.
MCB , DB SPN 4+12 way sheet metal enclosures double door.
Board distribution in sheet steel enclosure with bus bar neutral link, earth bar and Din rail suitable for fixing MCBs TPN 4 way 415 Volts Double door complete after taking down existing DB all as specified and directed.
MCB SPN 32 Amps 230 Volts, Single phase 50 Hz.
Replacement MCB, DP, 240 Volts, AC of breaking capacity 10 KA C curve of size 63 Amps
MCB, DP, 240 Volts, AC of breaking capacity 10 KA C curve of size 40 Amps
MCCB, 3pole, 415 volt AC, 100 amps, fixed type with breaking capacity 16KA all as specified.
MCB TPN 32 Amps 230 Volts, Single phase 50 Hz.
LED down lighter 6 watt. with aluminium housing. Make Bajaj cat no BGSLO Sleek 6 WH RD or eq model of Crompton , havells or make specified.
Supply, fix and testing LED down lighter 2' X 2' , 36 W surface mounting and fitting with false ceiling with complete accessories . All as directed by Engr-in-charge make Bajaj Skylux or equivalent model of Crompton and Philips and Havells.
Earthing complete with galvanised steel pipe electrode 40 mm bore, medium grade,2.5 mtr in length buried directly in ground with top edge not less than 1.25 metres below normal ground level, connected to galvanised earth wire 4 Sqmm by means of bolts, nuts, check nuts and washers of galvanised iron or steel connected to Earthing test point including watering arrangements, with 20mm bore medium grade GI Pipe, PCC chamber, CI frame cover all as shown in electrical plate No 2 including necessary excavation in any type of soil, filling of pit with charcoal & salt in alternate layers & testing complete all as specified. all as specified or indicated including testing on completion by Engr In charge .
Earth continuity conductor or main Earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop Earthing etc. as required using GI Wire 4 Sqmm as Earthing lead.
Supply & Fix Surface/pended mounting LED Retrofit Batten 18/20 W, with powder coated CRCA decorative patti with LED Tube ,Cat part No. SLE DB 18 LED and SLE TL-DS 18P Alpha of Surya /LTDC30120WLED/WD of C&S or Equi.model of Bajaj/Goldwyn/Crompton/Surya/HPL
S&F test and commissioning 35 W LED street light fitting system & with dedicated street light optics. Model Philips 35W Smart Bright Street Light or eq model of make III) HAVELLS; (IV) CROMPTON GREAVES (v) BAJAJ or make specified. Note:- (i)Driver & LED should be same make. (ii) Maintance/replacement of the Street light to done by contractor for 1 years after completion of work by free of cost.(iv) Cable and bracket included in quoted rate.
ceiling fan complete 230 V,1200 mm sweep. BEE 5 star rated
Supply and Laying in trenches or fixing on wall, floor etc LT, PVC/XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area of 4 core 16 sqmm size complete all as specified.
Supply and Laying in trenches or fixing on wall, floor etc LT, PVC/XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area of 4 core 10 sqmm size complete all as specified.
Supply and laying unreinforced pre cast cement concrete cable cover for cable protection (ready made covers) of sizes class LV type I, Flat size 250 X 150 X 40mm and laying adjacent to each other for protection of cable all as specified.
Surface excavation not exc. 30 cm deep and averaging 15cm deep and getting out in hard and dense soil including cutting of bushes,saplings and cutting trees not exe 30m girth etc complete.
Surface excavation not exc. 30 cm deep and averaging 15cm deep and getting out in soft and disintegrated rocks including cutting of bushes,saplings and cutting trees not exe 30m girth etc complete.
Removing excavated material as in soils exc. 1.5km but N. exc. 5KM, depositing where directed at a level N. exc. 1.5 M above the starting point, complete all as specified and directed
Removing excavated material as in rocks exc. 1.5km but N. exc. 5KM, depositing where directed at a level N. exc. 1.5 M above the starting point, complete all as specified and directed
OM ENTERPRISE
Parth Infrastructure Pvt. Ltd.
m/s.a.t.odedra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .