The Executive Engineer (Electrical)
O/o the Executive Engineer (E), BSNL Electrical Division, D/1 staff quarter, Lohanagar, Bhaktinagar Telephone Exchange Building. Rajkot
Operation and Caretaking of Electromechanical Services EMS at TE Building Bhaktinagar Rajkot
2020_BSNL_60081_1
27/EEE (R )/BSNL ED/2020-21
Open Tender
Repair and Maintenance Services
Item Rate
180 days
Rajkot
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
AO Cash GMTD BSNL Rajkot
₹4,755
4 Nov 2020
17 Oct 2020
3 Nov 2020
17 Oct 2020
2 Nov 2020
17 Oct 2020
90 days
Amount
Operation & Caretaking of all Electromechanical Services including attending operations involved thereto alongwith arranging necessary tools and safety equipments, maintainig daily record / Log-book for Substation & A/C Plant, DG Set areas and all other duties of electrical operator / caretaking assigned from time to time complete as per direction of Engineer-In-Charge. (all materials/consumables shall be provided by the departement except distilled water for DG Battery). The Operator/ Caretaker should make himself available within short time of an hour when called for any operational activity after his regular shiftt duty. The Operator / Caretaker shall conduct Fire Drill along with JTO (E) / SDE(E) & Building In-Charge once in a month by testing atleast 1/3rd of the detectors at all floors in rotation. (Note: 1 Person should be deplyoed per day) The Electromechanical Services includes -(1) 2 x 400 kVA Sub Staion (2) 1 x 250 kVA & 1 x 500 KVA DG Set (3) 6 x 7 TR PAC Plant (4) Auto Fire Detection & Fire Alarm System incl. 27Nos CO2 type fire extinguishers. (5) 2Nos 5 HP/3HP/1 HP Monoblock Submersible pumps (6) 2Nos 3 HP Submersible Pump (7)1.5/2.0/3.0 TR Split type A/C Units - 12Nos (8) EI & Fans and Compound Lighting (Note : Rate should be quoted for this item is Rate per worker per shift )
Supplying and fixing / replacement following Rating, 240V/ 415 v 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning , credit of faulty item etc. as required. 32 A TPN MCB
40 A TPN MCB
5 -32 A SP MCB
5 - 32 A SPN MCB
Rewinding of the following capacity Exh fans with copper conductor H class insulated copper enamalled suitable gauge wire i/c taking to workshop, reinstallation, painting, servicing, credit of burned windings etc as reqd (a) Single phase Exhaust fans / pedastal fans up to 200 Watts cap
(b) Single phase celling fan.
Replacement of existing compound light / street light lamp on pole/bracket with 18 Watts LED lamp in the existing fitting with lamp holder etc as reqd.
SITC of Aluminium die cast LED street light fitting of 18W suitable for operation on 230 V A.C. supply i/c removing the existing faulty fitting on pole/bracket i/c testing etc. comp. as required. (M/s.Syska/ Philips of S.S. make)
SITC of 4ft, 20W LED type batten suitable for operation on 230 V A.C. supply i/c removing of existing faulty fitting, making connection, testing etc. comp. as reqd. (M/s. Philips or S.S. make)
Supplying and fixing of following MCCB/TPN SFU / accesories in existing LT panel i/c dismantling of existing faulty parts, making connection etc as reqd. 63- 75 A TP MCCB ( 25 KA)
100/125 A TP MCCB ( 35 KA)
63 Amp. TPN SFU in open execution i/c HRC fuse link (AC-23 duty)
125 Amp. TPN SFU in open execution i/c HRC fuse link (AC-23 duty)
2/4 amp HRC Type control fuse link
63 Amp. HRC Fuse link.
100/125 Amp. HRC Fuse link.
Replacement of the following ISI marked items i/c credit for non return of faulty item as reqd. 4 feet long 36 Watts flourescent tube rod.
4 feet long 20 W / 18 W LED Tube Rods.
230 V starter suitable for flourscent tube rod fitting.
Electronic choke suitable for operation on single phase 230 volts.
Side holder suitable for flourscent tuberod fitting.
5/6 Amps capacity piono type switch.
15/16 Amps capacity piono type switch.
5/6 Amps capacity modular type switch.
15/16 Amps capacity modular type switch.
5/6 Amps capacity 3 pin socket outlet.
15/16 Amps capacity 3 pin socket outlet.
5/6 Amps capacity modular type 3 pin socket outlet.
15/16 Amps capacity modular type 6 pin socket outlet.
Supplying and drawing 1X1.5 Sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing 2X1.5 Sq mm FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
9W LED Lamp
Replacement / Supply of following type detector complete with base cover / MS Box/ MS Round box of having 4"X4" / junction bx/ stand / tripod etc and ITC of the same as directed by Engineer in Charge comp. As reqd. Photo electric type Smoke detector
Ionisation type Smoke Detector
Replacing of the following spares/ component in control panel of Existing Auto F/D system with same make & model including , making connections, testing and comissioning etc.comp. as reqd. Control Card
Zone Card
Power Card
SMPS Charging Unit
Replacement of / Supply of Manually Call point with LED indicator (Pill box) in MS box etc.comp. as reqd.
Refilling of existing 4.5 kgs. CO2 type fire extinguishers including transportation to authorised service centre including testing, pvdg. data sheet sticker & factory certificate etc as required
Replacement of defective 1.0 mtr long hose pipe( steel wire breaded pipe ) with brand new pressure tested horn pipe a/w suitable for existing 4.5/3.6 kg CO2 type fire extinguishers etc as required.
Replacement / supply of following rating sealed maintenance free battery in dully charged condition i/c fixing making connection testing etc.as required ( Approved make of BSNL ) 12 Volts, 20 AH
Amit Electricals
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .