Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹15.0 Cr
EMD Value
₹30.0 L
Closing Date
5 Jan 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ACE PHED Region-II Jodhpur
ACE PHED Region-II Jodhpur
WORK OF CONVERSION OF DWSS SHCHEME OF VILLAGES SATYAYA TADANABALANASEWDA INTO PWSS TEHSIL POKARAN MLA CONSTITUENCY POKARAN DISTT JAISALMER WITH PROVISION OF FHTCS UNDER JJM WITH 5 YEARS OAND M AND 1 YEAR DLP
2025_PHCJO_519224_1
NIB 17/2025-26 ACE2JU
Open Tender
Civil Works - Water Works
Percentage
365 days
Pokaran
As per TD
2 documents required · 2 mandatory
₹10,000
EE PHED Pokaran and Director RISL
₹30.0 L
Yes
10 Dec 2025
10 Dec 2025
6 Jan 2026
10 Dec 2025
5 Jan 2026
10 Dec 2025
Cost for Basic Service Charges, Administration and Management, Running of Office, Comprehensive Operation, Maintenance and Repairs including Preventive Maintenance, Cost of material required for maintenance & repairs, Cost of Lubricants, salt for producing chlorine, Consumables, Spare Parts (if the spare parts supplied to PHED are used in emergency) as per Scope of Work & terms & conditions of contract for 5 year after defect laibility period of one year (except power feeder, IEC & miscllenous provision)
BoQ_Ver3.0
Bidder Name :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
(1.31) Add extra over item no 1.21, 1.22 & 1.23 for providing 20 mm PE 80 PN 16 as per ISO 4427 MDPE pipe including excavation, providing, laying & jointing of service line above 5.00 mtr.
(1.29) P& F Bib cock (IS : 8931 mark), superior quality of approved make, with foam flow chrome plated with complete brass body including brass handle with wt 300 to 325 gm.15 mm nominal bore.
(1.3) Road cutting for house hold service connection in minimum trench width wherever road crossing is required. Road cutting of cement concrete,WBM, Black top etc. of all thickness shall be done by using a concrete cutter machine keeping minimum trench width and restoration of the road with Cement concrete with PCC M-10 and CC M-30 grade as per specification and direction of Engineer in charge..
(14.3) Data entry of existing FHTCs in rural area under JJM on website ejalshakti.gov.in; work includes visiting the village for collecting basic data consumers like i.e. Aadhar no./ration card/voter ID/BPL card/ PAN card/driving license/passport/Antyodaya card/mobile no. etc. and entering the details on the above website. The cost also includes computer and operator.
CONSTRUCTION OF RWR 30000 KL
PWD BSR/2019/B-1/1.34.1 : Clearing Grass and Removal of Rubbish Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per Technical Specification Clause 201.In all kind of soil
PWD BSR/2019/B-1/1.8: Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sum on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed: All kinds of soil.
PWD BSR/2019/B-1/1.10.1 : Add extra over item No. 1 for every additional lift of 1.5 Mtr. or part there of : In all kind of soils
PWD BSR/2019/B-1/1.10.1 Add extra over item No. 1 for every additional lift of 1.5 Mtr. or part there of : In all kind of soils 3 to 4.5 Mtr.
PWD BSR/2019/B-3/3.2.4 : Providing and laying in position cement concrete including curing compaction etc. of specified grade excluding the cost of centering and shuttering All up to plinth level IS 456-2000 : 1:3:6 (1Cement :3 Course Sand :6 Graded stone aggregate 40 mm nominal size (Crusher Broken)
SEJSL 15-16/2203 Double PCC Block lining 120mm thick with ppc block size 30x15x4 cm inside slope, bottom layer laid in 6mm thick cement mortar 1:5, Bajari over base plaster of 12mm thick in cement mortar 1:6 (1 cement : 6 bajari) and 16mm thick sandwich plaster of 12mm thick in cement mortar 1:3 (1 cement: 3 bajari) & top layer of PCC Block laid in 6mm thick plaster in cement mortar 1:3 (1 cement: 3 bajari) including mechanical mixing mortar, dressing of side slope, scaffolding, providing, laying and jointing of LDPE & curing for 28 days complete as per specification including cost of LDPE film and including cost of jointing material.
SEJSL 15-16-2203 Double PCC Block lining 120mm thick with pcc block size 30x15x4 cm in bed, bottom layer laid in 6mm thick cement mortar 1:5, Bajari over base plaster of 12mm thick in cement mortar 1:6 (1 cement : 6 bajari) and 16mm thick sandwich plaster of 12mm thick in cement mortar 1:3 (1 cement: 3 bajari) & top layer of PCC Block laid in 6mm thick plaster in cement mortar 1:3 (1 cement: 3 bajari) including mechanical mixing mortar, dressing of bed, scaffolding, providing, laying and jointing of LDPE & curing for 28 days complete as per specification including cost of LDPE film and including cost of jointing material
PWD BSR/2019/B-6/6.1.5 : Random Rubble stone masonary for foundation and plinth in Cement Sand Mortar above 30 Cm. thick wall IS 1597 (Part-I) 1992 in : Cement Mortar 1:4 (1-Cement:4-Sand).
(CE Rural Letter/4212-15 ated 18.06.2021) Design,Construction, Commissioning and Testing of Non-Mechanical Rapid Gravity Filter Plant of Capacity as under ( 8 Working Hour in a day ). This work includes construction of RCC Recieving Chamber, baffle channel, floculator , elearifier, Clacting Channel, Filter beds.Operation Gallary, Clear water chamber,Channel ,Clorination Chamber , Pipe system for carrying Raw water from Pump House to inlet of RGF,Clear water from plant to CWR, De-sludging system, including providing pipe system from clarifier , Floculator & Back wash water chamber to existing storage tank , Back wash pumpset with piping system , air blower as per design interconnection of raw water clear water , sludge pipes etc including allied works such for construction , commissiong of system as specified in Tender document at various water supply schemes.
PWD BSR/2019/B-12/12.9.2 : Plaster on new surface on walls in cement sand mortar 1:6 including raking of joints etc. complete fine finish : 20 mm thick.
(6.1) Providing, lowering, aligning, fixing in position in pipe line, CI D/F Sluice valves of approved make of following Pressure rating & dia complete, confirming to IS:14846 (amended up to date) and of following specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand wheel of Grey cast iron of IS:210/ FG200 Stem - SS 304 ,Body Seat ring, Wedge facing ring & Bushes - LTB2/ SS , Face to face dimensions as per IS 14846/2000 (amended up to date), All exposed machined ferrous surfaces shall be painted with one coat of aluminium red oxide primer conforming to IS:5660 and two coats of black Japan paint conforming toType B of IS 341or paint conforming to IS9862 or IS2932( Non-Toxic- suitable for drinking water) applied inside and outside, Flanges Drilled as per IS 1538.Nut-Bolt confirming to IS:1363 and IS: 1367/ CS/ galvanised steel.Insersion rubber of black EPDM 6mm thick . Suitable support structure as per directions of EIC. Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
(4.1) Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
(4.5) Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
(4.7) Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
(4.8.1) M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
(4.9.2) b) 80 mm thick.
(4.9.3) c) 100 mm thick
(6.6) Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valve of approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amended up to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 , Float Guide- HBT1.HP Orifice- HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. Note: Rates are exclusive of connecting tee, pipe piece and earth work.
(1.15) Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
(1.15.1) MS pipe specials up to 600mm dia (with minimum 5mm thickness sheet)
(9.1) Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15 as leveling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast, Plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as per specifications and standard drawings and as directed by Engineer-in-Charge.
(9.1.2) For Class-A loading
(9.1.2.1) Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm
(11.1.3) EFM100 mm
(11.1.5) EFM 150 mm
(4.1) Horizontal directional drilling (by trenchless technology) of suitable dia hole minimum 1.0 mtr below natural ground level in all type of soil under CC/BT roads and pulling HDPE pipes of dia up to 110 mm, which are available in the form of a coil including excavation, shoring/ strutting, preparation, maintain the thrust and including, road dismantling, excavation and refilling of drive pit and exit pit, restoration of road cut as per technical specification and scope of work. Excluding cost of pipe line. Note: Trenchless laying shall be done only for laying of pipe line (rising main) and road crossing of distribution pipe line under CC/BT roads.
(4.11) Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
(4.11.1) 300 mm Dia 8 mm thick casing pipe.
(Rate Analysis) Construction of RCC Air Valve Pillar for fixing double/single air valve as per approved drawing and specifications to the satisfaction of Engineer-in-Charge ( at every 1 Km interval )
(6.3.1) Class PN 1.0
00 mm dia
PWD BSR/2019/B-11/11.3.3 : Cement concrete flooring grade 1:2:4 (1-Cement:2-Coarse sand:4-graded stone aggregate) rounding off edges etc. but excluding the cost of nosing of steps etc. complete IS 2571-1970 : 50 mm thick with 20 mm thick nominal size aggregate.
(1.4) Providing, lowering, laying and jointing in trenches, standard lengths HDPE ISI marked Pipes as per IS-4984: 1995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work) . Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. Supply may be in coil or straight length in 6 M/12 M.
(1.4.1) HDPE PE-80 PN-6
(1.4.1.2) 75 mm dia
(1.4.1.3) 90 mm dia
(1.5.1) HDPE PE-80 PN-6
(1.5.1.1) 125 mm dia
(1.5.1.2) 140 mm dia
(6.1.1) Manually Operated CI Sluice valve of Class PN-1.0
(1.5.1.3) 160 mm dia
(4.1) Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil
(4.5) Dismantling of cement concrete pavement for pipe line line and chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work.
(4.7) Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
(4.8) Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be made as per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, complete work as per technical specification and scope of work.
(4.8.1) M20 grade Nominal Mix 1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size).
(4.9) Removing & Re-fixing of Precast concrete interlocking blocks for laying of pipe line by manual method, stacking of serviceable & non serviceable material separately, disposal of dismantled material lead up to 50 mtr. The C.C. interlocking paving blocks be laid on average 25 mm thick bed of coarse sand and the joints to be filled with fine sand. Laying procedure on compacted sub base as defined. Complete job is to be executed as per the directions of Engineer in charge. The rates to be inclusive of fixing of minimum 70 percent reusable precast concrete interlocking block and cost of required new precast concrete interlocking block against damaged, including all lead and lift as per Technical specifications. (Interlocking block manufactured by fully computerized automatic stationery hydraulic vibro pressed machine & full computerized automatic batching plant of class A-1 as per BS:6717-2001. Tensile splitting strength and breaking load as per BS: 6717-2001 Colour: Grey cement natural colour. Variation in Dimension : Less than 1.6 mm Variation in thickness: Less than 3.2 mm)
(4.9.2) b) 80 mm thick.
(4.9.3) c) 100 mm thick
(9.1.2.1) Sluice valve chamber of size1.13m x0.85m x1.27m for pipe size-upto100mm
(PHED BSR / 2023 / 8.1) Construction of Pump house of required size suitable for installation of maximum 4 no. monoblock pump sets as per approved GA drawing, scope of work and technical specification complete work in all respect including electrical works for lighting and fans, rain water drainage. The plinth area of pump house shall be area of measurement. (2 NOS )
(PHED BSR / 2023 /8.2) Construction of boundary wall of Brick/ stone masonary as per enclosed GA drawing, scope of work and technical specifications complete work in all respect. Brief details of boundary wall parameter is as below: 1. Depth of foundation- 900 mm. 2. PCC in M-10, width -900 mm and thickness 100 mm, 3. Stone masonary in CM: 1:6 section of foundation above PCC, 600 mm (W )x 450 mm (D) and 450 mm (W) x 450 mm (D) 4. Superstructure work: Stone masonary in CM: 1:6, W-300, height-1650 mm,/ Brick work in CM: 1:6 W-230 mm, height- 1650 mm. 5. Cement mortar pointing on Stone masonary and cement mortar plaster 20 mm thick on brick masonary in CM 1:6. 6. Expansion joint shall be on every 30 mtr. 7. On top of wall there shall be CC Coping 75 mm thick (1:2:4) shall be provided. 8. Pillar for main gate 350x350 mm in size is part of boundary wall. 9. Cement paint of approved colour in 3 coat shall be done.
(PHED BSR / 2023 /8.3) Providing and fixing steel, gate, grating and grills made of angles, tees, square bars, flats or black pipe with hold fast and fitting complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide and two coat of enamal paints.
RISING MAINS PIPELINES (Based on PHED BSR 2023 Revised)
DISTRIBUTION PIPE LINES (Based on PHED BSR 2023 Revised)
(PHED BSR 2023/1.15) Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/ depths in trenches complete including all taxes, material, labour, inside lining, outside coating, testing and commissioning along with pipe line as per technical specifications and direction of Engineer-in-charge.
(1.15.1) MS pipe specials upto 600mm dia (with minimum 5mm thickness sheet)
(PHED BSR 2023/1.24) Providing, lowering, laying, aligning, fixing in position at all level/ depths CI Class - B specials as per IS : 1538, amended up to date in trenches complete including all material, labour, testing and commissioning along with pipe line/ appurtenance as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately.
(1.24.2) Double flanged CI pipe fittings.
00 mm dia
(PHED BSR 2023/6.3) Providing, lowering, aligning, fixing in position in pipe line, CI double flanged swing type Non Return Valves (NRV) of approved make of following Pressure rating & dia complete, confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Cover & disc of Grey cast iron of IS:210/ FG200. Face to face dimensions as per IS 5312 (part -1):2004 , Flanges Drilled as per IS:1538. Epoxy (Non-Toxic & suitable for drinking water) applied on body, cover and disc inside and outside . Body seat ring of SS/CS Door face ring - EPDM/ Neoprene (food grade quality) ,Shaft of HTB1/ SS- AISI- 410 ,Hinge Malleable cast iron / SS AISI 316/410 ,Bonnet Gasket EPDM, Bush- Leaded tin Bronze/ PTET, Gasket EPDM/NBR ,Nut-Bolt as per IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of EIC including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work.
(PHED BSR 2023/6.17) Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0
(6.17.2) 100 mm dia.
CIVIL WORKS (Based on PHED BSR 2023 Revised & BSR CE SP PROJECT)
(6.17.4) 150 mm dia.
(PHED BSR 2023/ 2.20) Supply & Fixing XLPE insulated / P.V.C. sheathed cable of 1.1 KV grade with aluminium conductor Armoured of IS:7098-I/1554-1 approved make in ground as per IS:1255 including excavation of 30cmx75cm size trench, 25 cm thick under layer of sand, second Class bricks covering, refilling earth, compaction of earth, making necessary connection, testing etc. as required of size.
(2.20.2) 16.0 Sq.mm, 4 core
(2.20.4) 35.0 Sq.mm, 3.5 core
(2.19) Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
(2.19.2) 3 core 6.0 Sq.mm
(2.19.3) 3 core 10.0 Sq.mm
Estimate for Gate on Boundary Wall
(PHED BSR 2023/ 2.21) Plate Earthing as per IS:3043 with G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe including all accessories like nut, bolts, reducer ,nipple, wire meshed funnel, and C.C. finished chamber covered with hinged type with locking arrangement C.I. Cover, C.I. Frame of size 300mm x 300mm complete with alternate layers of salt and coke/charcoal, testing of earth resistance as required.
(4.11.1) 300 mm Dia 8 mm thick casing pipe.
Type - B
(PHED BSR/ 2023/ 4.11) Supply laying and pushing of MS casing pipe of specified thickness approved by concerned department authority by trenchless method adopting any suitable technology below ground at
required depth under running traffic condition as per Highway/ Railway standard including carrying out survey work at the job site for determining underground cable trenches like telephone, cable, water & sanitary lines and resistivity test for finding the soil strata using necessary equipments for completion of works, mobilizing of machineries and specialized crew at the job site complete in all respect, including excavation of driven pit and exit pit (up to 3 meter depth) with proper protection at these sites with shoring sheets and ISMB. Providing MS cutting edges for front shield and constructing thrust bed at designated level. Necessary dewatering and providing concrete foundation at the base of the driven pit, PVC/Rubber saddle as per the requirement of Highway/Railway authority, crane for handing of pipe and any other machinery, tools, and tackles required, construction of temporary works as per design, drawing and method as per approved by authority specification and the direction of the Engineer. Apply corrosion, resistant, protection on inside and outside of casing pipe as per technical specification.
(10.3) Supply, installation, testing and commissioning of MNRE approved off Grid Solar Panels for running of motor pumps with 25 years of Linear Generation warranty, Work includes designing of solar panel area and MS fabricated structure 120 micron hot dip galvanized iron , showing arrangement of panel in available space and installation of PV module on frame structure such that minimum height of lower edge of panel shall be 4.0 mtr from ground level to safeguard against damage and theft as per indicative drawing enclosed with the bid document. The foundation of structure shall be in RCC. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for solar panel and mounting structure and suitable provision shall be included in tender document.
Pump House Commisioning (2 Nos.)
(10.5) Providing, installation, testing and commissioning of AC submersible pump sets with inbuilt or individual solar pump controller with Maximum power point tracking (MPPT) for optimally use the solar panel and maximize water discharge to deliver maximum water during the day including PVC flat submersible cable from controller to motor pumps.. Solar pump shall be of Stainless steel construction and performance shall be as per scope of work and minimum lift of water shall be as per defined in scope . Pump controller shall have Adequate protection against dry operation of motor pump set, and against hails and storms. Full protection against open circuit, accidental short circuit and reverse polarity should be provided. A good reliable on/off switch be provided. The cable shall be ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date ( standard insulation) and conductor as per class 5 of IS 8130:1980 or amended up to date. The duty condition of pump set shall be as per scope of work and entire work shall be executed as per technical specification and direction of Engineer in charge.
(2.1) Construction of tube well from ground level & up to 100 mtr depth to accommodate housing and assembly pipe of following sizes in all type of alluvium strata unconsolidated formation such as pebbles, boulders etc. by percussion/rotary drilling method as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications, with gravel as per IS:4097-1967 and it's packing as per IS: 2800 (Part I & II) 1979 as amended up to date (the work includes the cost of gravel & it's primary packing and packing during development, lowering of housing & strainer assembly pipes with supply and wrapping of coir-rope, wherever necessary for arresting fine sand particles and development work, but excluding the cost of housing and strainer pipe assembly). The work would be completed after obtaining sand free water.
(2.1.1) Nominal bore 150 mm dia.
(2.1.2) Nominal bore 200 mm dia.
(2.1.3) Nominal bore 250 mm dia.
(2.8) Testing verticality of tube well by plumbing system and yield test and draw down test by pumping system as per IS : 2800 (Part – II) – 1979 or as per amended up to date.
(2.9) Supplying & Packing P-gravel suitable for slot size/mesh size as suggested in IS 2800 (Part-1) 1991 or as per amended up to date.
(2.1) Development of tube well having depth up to 250 mtr as per IS: 11189- 1985 and IS: 2800 (Part- I)- 1991 (both amended up to date) using suitable methods to give sand free water for required yield of the gravel packed tube well.
(2.14) Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.
(2.14.1) Up to 2.0 KW
(2.14.2) Above 2.0 KW
(2.19) Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
(2.16) Supply and Fixing of Electric feeder panel (having projected canopy)for submersible pump set Single phase up to 5 HP, comprising of DOL Starter, MCB, Indicating Light, Ammeter, Volt meter, connection plate, condensers of approved make and the panel enclosure should be made out from 18 gauge M.S. Sheet with powder coating. Panel size Height 600 mm Width 500 mm depth 250 mm with Stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg’s length 18" and double door including in built locking system. The legs should be embedded in M-15 cement concrete platform. The size of CC platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. The operation of panel should be suitable for on 240 Volt AC Supply.
(2.19) Supply & Fixing of ISI marked three core PVC flat submersible cable as per IS 694:1990 or amended up to date and conductor as per class 5 of IS 8130:1980 including making connection etc.
(2.19.4) 3 core 16.0 Sq.mm
(2.22) Supply & Fixing M S clamp set of 50x6 mm flat from iron with nuts and bolts etc. for holding the riser pipe assembly of submersible pump set.
(2.23) Supply & Fixing tube well cover of MS sheet 8mm thick at top & 5mm thick 100mm wide shroud around the edge so as to form a cap on the top end of casing pipe with GI Nipple 45cm long & two GI flanges at both ends in 80mm sizes passing through a hole in the centre of MS sheet. A 25 mm socket with end plug shall also be welded over top plate. A GI nipple having outside thread of size 1/2" (for installation pressure gauge) shall be provided & welded with 80mm GI nipple near top plate nipple shall be provided with end plug.
125 mm dia
(2.23.2) 150 mm dia
(2.23.3) 200 mm dia
(2.23.4) 250 mm dia
(2.25) Providing & Lowering in tube well ISI marked HDPE pipe as per IS 4984:1995 or amended up to date in PE 80 grade and class PN 10 of following dia. including HDPE/GI fittings and PVC rope confirming to IS 5175:1992 or amended up to date, along with clamping of submersible cable etc. complete in all respect.
(2.25.1) 40 mm dia
(2.25.2) 50 mm dia
(2.25.3) 63 mm dia
(2.25.4) 75 mm dia
(2.25.5) 90 mm dia
Part - A: Electrical Works
(2.35) Supply of ISI mark AC pressure pipe class 15 manufactured by MAZZA process as per IS:1592-2003 or amended up to date, for casing of tube well for following dia nominal bore, with jointing material PVC coupler as per technical specification and direction of Engineer In charge.
ROAD CROSSING
Solar System (4 Nos.)
(2.35.2) 150 mm nominal dia
(2.36) Making slots of hole size and Nos. as directed by EIC in AC pressure pipe Class 15 as per technical specification for using slotted pipe in TW casing.
(3.2) Construction and commissioning of RCC INTZE type Over Head Service Reservoir of following capacity and staging as per the Scope of work and Technical specifications, consisting of the following main activities: -
(3.2.4) Rates for RCC OHSR,SBC 10 T/sqm, SEISMIC ZONE-II & STAGING 18 M
(3.2.4.1) 100 KL capacity
(3.2.4.2) 150 KL capacity
(3.2.4.3) 200 KL capacity
(3.7) Providing and fixing double flanged ISI marked DI Class K-9 pipes as per IS:8329-2000 (amended up to date), as vertical pipes for RCC Reservoirs including specials required such as duck foot bend, bend, tee etc. providing and fixing clamps at every 3 mtr, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. complete in all respect up to and from valve chamber as per direction of EIC, Technical Specification and Scope of work.
Construction of Tube Well (4 Nos.)
CONSTRUCTION OF OHSR AND CWR ( RATES AS PER PHED BSR 2023 Revised)
a) Topographic survey, preparation of site contour plan, conducting SBC test and its approval from department before construction. Submission and approval of concrete mix design and water quality test report for water to be used in construction. b) Excavation in all types of soil, PCC below foundation, all RCC Work, Plinth protection all around the structure including all material, labour, shuttering, scaffolding etc. c) OHSR shall be provided with adequate plinth protection all around the structure in a width starting from edge of structure at GL and extending at least up to 1.0m beyond the edge of outer most projection of OHSR. The plinth protection shall consist of 150mm thick PCC in M-15 grade concrete laid over 150mm thick layer of compacted soil. d) Providing and applying two coats of food grade epoxy paint on the inside surface on the top dome, edge beam and 600 mm height of the vertical wall. e) Conducting successfully hydro test and water tightness test as per I.S. code. f) Providing and applying three coats of anti-carbonation paint on the top surface of the Top Dome. g) Providing and applying three coats of cement-based paint on the external surface of the container, balcony, cone wall, columns & beams etc.. h) Providing and fixing SS-304 ventilator, SS 304 manhole frame and cover and SS-304 ladder from top dome/Slab to bottom dome/Slab inside container. i) Providing and fixing of MS section ladder from the last landing to balcony having railing all around it and MS ladder with safety cage from balcony to top dome/slab. j) Providing and fixing water level indicator (float type).
(3.3) Construction of RCC (Flat slab type) Clear Water Reservoir of following capacity as per the Scope of work and Technical specification, consisting of the following main activities: -
(3.3.1) Rates for RCC Partially Underground type clear water reservoir SBC 7 T/sqm, SEISMIC ZONE-2,3 & 4
(3.3.1.5) 200 KL capacity
(PHED BSR/ 2023/ 5.1) Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at syncronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected on C.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
(5.1.1) Centrifugal Monoblock Pump set (Single Stage)
(5.5) Providing, installation, testing and commissioning of submersible monoblock pump set conforming to IS 8034 and 2 pole motor operating at synchronised speed of speed 3000 RPM, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz AC and with water lubricated bearing to accept entire hydraulic thrust. Supply, with cable guard, thrust carbon/fibre bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer's design. Antithrust stream lined non return valve shall be provided with the pump and minimum 6 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump etc. complete in all respect as per specification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.
k) Providing and fixing of hand railing all around the balcony, top dome and staircase consisting of 25mm diameter Class-B GI pipe in two rows and 1000 mm high, 50X50X6mm angle iron vertical post at a maximum spacing of 1500mm centres. l) All MS parts to be painted with two coats of the enamel paint over the primer coat of red oxide. m) Providing and fixing of 150mm wide PVC water bar for the construction joints in the container (vertical wall & cone wall). n) Providing one Aluminium portable ladder of appropriate length to access first landing (3.5 to 4.5m above GL) from ground. o) Lighting arrestor consisting of providing and fixing of 2 Nos. of chemical earthing and connecting it to the conical cover of SS ventilator with two separate GI strips of 50mmX3mm. p) CI/DI puddle collar shall be fixed in the botto
(1.26) Providing Household Tap Connection as per technical specification and approved drawing and as per relevant IS code (amended up to date) from HDPE pipe line up to consumer meter/premises by using electro fusion saddle piece (Complete job).This job includes digging out suitable size of pits and trench for laying service line in all kinds of soil; depositing and refilling of pit & jhiri with watering & ramming /compacting in layers and disposal of surplus excavated soil as directed with in a lead of 100 meter ; providing & fixing of all fitting duly approved in accordance with specification for potable water including electrofusion saddle piece, gunmetal ferrule 4.0 mm , GM Full-way Valve (IS:778 Mark) or wheel valve and specials, below ground level 20 mm nominal dia MDPE pipe PE 80 PN 16 as per ISO 4427 / 20 mm nominal dia PPR-C (Three lay
ered) pipe PN16 SDR 7.4 (IS:15801:2008) (ISI mark) for and above ground level using 20 mm dia PPR-C pipe with standard PPR fittings/ 15 mm dia GI pipes with fittings in the premises for fixing a tap / meterbox (excluding) ,including accessories with flushing, cleaning, disinfecting and testing of pipe line complete required for making of service connection complete in all respect including labour charges . The service line should be laid at least 45 cm below ground level. Note: Road cut and restoration is not part of this item and paid seperately.
(1.26.1) For connection with 20 mm dia MDPE/PPR-C pipe length up to 05 mtr.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
BOQ_926377.xls
BOQ • 0.58 MB
TD17.pdf
Tender Documents • 6.99 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .