Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC 0 HISAR HISAR HARYANA 125004 UDYAM HR 06 0052049 | HISAR | HARYANA | 125004 | ₹35.4 L Quoted ₹36.5 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹38.6 L+₹2.1 L (5.69%)Rejected-Finance | ₹38.6 L+₹2.1 L (5.69%) | L2 | Rejected-Finance Second Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
17 Feb 2020, 6:00 pmClosed
Maj Saikat De
GE (I) Navy Porbandar Tija Mile Porbandar
PROVN OF POL STORE, LOW WALL FENCING, ADDITION ALTN TO TECH AREA AND CHAIN LINK FENCING AT NAE PORBANDAR
2020_MES_313154_1
9005/PBR/E8
Open Tender
Miscellaneous Services
Item Rate
150 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer (I) Navy
₹90,000
Yes
24 Feb 2020
9 Jan 2020
18 Feb 2020
9 Jan 2020
17 Feb 2020
24 Jan 2020
10 Jan 2020 - 23 Jan 2020
Amount
M&L for Surface dressing n exc. 150 mm deep in hard/dense soil. complete all as specified and directed by Engineer - in Charge. Note:- Area of surface dressing and surface excavation are not payable simultaneously.
Excavation in trenches, n. Exc. 1.5m wide and n exc 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil
Excavation in trenches, n. Exc. 1.5m wide and n exc 1.5m in depth, for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock
M&L for PCC type D2, 1:4:8 (40 mm graded aggregate) as in foundations, filling and mass concrete, complete all as directed by Engr-in-Charge.
M & L for 40mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork cement concrete 1:2:4 type-B0 complete all as specified. (Note : water proofing compound to be measured and paid for separately).
M&L Anti termite treatment by Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured)
M&L Treating with Anti-termite Treatment for top surface of filled earth of floor and soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as directed by Engr-in-Charge.
M&L PCC 75 mm thick, type D-2, 1:4:8 (40mm graded aggregate) under plinth beam, complete all as directed.
M & L for 75mm thick PCC 1:3:6 , type C-2using (20mm graded stone aggregate) as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1).
M&L for RCC type M-30 (20 mm graded aggregate) as in rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc. complete all as directed by Engr-in-Charge. Foundations, including
M & L for Reinforced cement concrete M-30 design mix (using 20 mm graded stone agg) in columns, pillars, piers, posts and struts etc
M&L for RCC type M-30 (20 mm graded aggregate) as in Beams, cantilevers,bressummers, lintels over 1.5m span. complete all as directed by Engr-in-Charge.
M&L for RCC type M-30 (20 mm graded aggregate) as in slab supported on walls, beams and columns in roofs etc. complete all as directed by Engr-in-Charge.
Returning, filling in, including spreading, levelling, watering and well reamming in layers not exc 25 cm in rocks, complete all as directed by Engr-in-Charge.
M & L for form works rough finished surfaces of concrete side of concrete foundation , footing , bases of coloumns raft and raft beams sides and sofits if any of foundation and plinth beams and similar work flat , vertical or to batter
Use and waste of formwork to sides of columns with rough finished surfaces of concrete in square, rectangular or polygonal.
Use and waste of formwork to sides and soffits of roof beams, lintel beams etc. including supports, overhangs, etc. also splays between floors and beams, etc. complete all as directed by Engr-in-Charge, with rough finished surfaces of concrete in flat.
Use and waste of Formwork to soffit of suspended slabs such as roof slabs floor slabs, landings and similar works not exc 200 mm thick (Horizontal or sloping)with rough finished surfaces complete all as directed by Engr-in charge.
Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed
Mild steel CRS bars 8mm dia as in stirrups spacer and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L stone walling porbandar type block masonary in cm 1:6, brought up to courses, complete all as directed by Engr-in-Charge.
M&L rendering 5 mm thick on fair face of brick work or concrete surfaces in CM 1:3 (in ceiling) finished even and smooth without using extra cement complete all as directed by Engr-in-Charge.
M&L rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:6 finished even and smooth without using extra cement complete all as directed by Engr-in-Charge.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even complete all as specified and directed on external surfaces using WPC. NOTE: Water Proofing Compound shall be paid separately.
M&L for 10 mm thick (average) plastering on concrete surfaces in cement mortar 1:4, in order to maintain proper slope and base over existing roof surfaces for laying of APP based polymeric membrane, add WPC @3% of cement weight(WPC paid separately), finished even and smooth without using extra cement complete all as specified and as directed. (Note:- Polymeric membrane will be measured and paid separately)
M&L for Moorum/red bajri filling in floors or pavings, laid in layers N.exc. 15 cm thick, spread, levelled and reammed including watering, complete all as directed by Engr-in- Charge.
M&L Screed bed or bedding layer or mortar 15mm thick for laying floor tiles in cement mortar 1:6 finished rough to receive floor tiles Complete all as specified and directed.
Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L 18 to 22 mm thick kota stone slab as in skirting, riser of steps and pillars over and including 10mm thick rendering in cement mortar (1:4) complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
M & L for two coats of acrylic emulsion weather proof antifungal paint on newly plastered surfaces of wall or concrete surfaces including preparation of surfaces and one coat of primer complete all as specified & directed by Engr-in-charge.
M & L preparing surface of newly plastered walls and applying two coats of oil bond distemper over chalk whitening preparatory to distempering.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified. Anodised
S&F powder coated aluminium ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified complete all as directed by Engr-in-charge.
S&F 5.5mm thick sheet glass, ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane.
S&F Steel rolling shutters (thickness of lath 1.25mm), with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified complete all as directed by Engr-in-charge.
M & L for two coats of synthetic enamel paint over a priming coat of red oxide after preparation of new surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed by Engr-in-charge.
M & L for 100 mm thick cement concrete type D-2 (1:4:8) mix using 40 mm graded stone aggregate as in sub base complete all as specified and directed by Engr-in-charge.
M & L for 100 mm thick PCC of M-20 (nominal mix) using 20 mm graded stone aggregate as in hard standing complete all as specified and directed by Engr-in-charge.
BLANK
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in Hard Dense Soil complete all as specified and directed by Engr-in-charge.
M&L for hard core (broken stone or boulders) of gauge n. exc. 63 mm but n exc 100mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rolled/rammed to a true surface all as specified & directed by Engr-in-charge.
S & F fine dry sand filling under paver block incl consolidation all as directed by Engr-in-Charge.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade, finished with grey cement and no pigment, complete all as directed by Engr-in-charge.
Dismantling fencing wire mesh any type complete all as specified and directed by Engineer - in - Charge.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed surface complete all as specified and directed by Engineer - in - Charge.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed by Engineer - in - Charge.
Removing excavated material (Soils) to distance of exc. 1.5 km but n. exc. 5 km and depositing outside MoD land all as specified & directed.
M & L for 15 mm thick rendering cement plastering on fair faces of brick work or concrete surfaces 1:4 mixed finished even and smooth (without using extra cement)
M & L for two coats of cement base paint over a coat of primer over newly plastered wall surfaces
M&L for angle posts and struts in fencing including stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts, angle posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
M & L for preparation of steel surfaces of any description over 10 cm in width or girth not otherwise described and two coat of synthetic enamel paint over one coat of red oxide
S & F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or typing at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured)
S&F Bitumen dip Concertina Coil, punched tape 2.60 mm dia high tensile spring steel wire, dia of coil 610mm, when stretched the length shall be 6.00m in one coil, (weight of stretched coil shall not less than 1.30kg/m) and tied to barbed wire with and including provision of steel clips @ 5 clips spiral in one row complete without coating all as directed by Engr-in-Charge.
M & L for P.C.C coping as in 1:3:6 type C-1 on top of wall.
M & L for broken glass coping in 25 mm thick screed bed cement mortar 1:3 on top of wall.
Taking down old roof treatment of any description including plaster, cement concrete etc. and removing old material outside MD land exc 1Km and not exceeding 5 Km completely all as specified and directed by Engineer - in - Charge.
M&L PCC 1:2:4 type B-0 using 12.5mm graded aggregate 25 mm thick in floor Complete all as specified and directed.
Supply only integral waterproofing compound
M&L for water proofing treatment to RCC roof slab including parapet comprising with the following course of treatment / specification from bottom to top:- (a) Applying bituminous primer @ 0.40 litre per Sqm over plastered surfaces of roof including parapet surfaces. (b) one layer of APP based polymeric membrane of approved manufacturer, 3 mm thick, weight not less than 3.6 Kgs per Sqm, reinforced with non wovwn polyster fabric or weight not less 150 gms per sqm. Polymeric membrane shall be taken to a height of 60 cm 9 minimum) and then inserted insde the groove of parapet wall and shall be finished by a membrane flashing. Note:- (i) Laying of APP based membrane shall be done by torch on method or as per manufacturers instruction. (ii) A minimum overlap of 150 mm and 100 mm should be made in the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as manufacturers instruction. (iii) Applying two coats of Bituminous aluminium paint on top of APP membrane.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded & pointed in any mortar complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick cement mortar 1:4 complete all as specified and directed by Engr-in-Charge complete all as directed.
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in skirting including 10mm thick cement mortar 1:4 complete all as specified and directed by Engr-in-Charge.
Demolition of masonary of any description or thickness in walls etc. complete all as specified and directed.
M&L Granite (of any type) work of 20mm thick (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match complete all as specified by Engr-in-charge.
S&F in sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and as directed.
S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
Taking down & refixing Chowkats or frames exc. 1.5 Sqm but not exc. 4 Sqm each (without taking off shutters from the frame) each in other opening after repairing complete all as specified and directed.
Taking down window, boards, etc. Chowkats or frames exc. 1.5 Sqm but not exc. 4 Sqm each (without taking off shutters from the frame) each complete all as specified and directed.
M&L rendering 10 mm thick in CM 1:4, for laying wall finishes for back coat of wall tile complete all as specified and directed.
M & L for Glazed ceramic tiles of size 300mm x 450mm x 7 mm thick (coloured) of superior quality fixed on vertical surfaces such as skirting, dado, risers etc. over 10 mm thick in CM 1:4 backing coat, compete all as specified and as directed
S&F powder coated anodised aluminium door shutters, window shutters aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminium snap beading screws etc. complete all as specified and as directed by Engr-in-charge.
S&F 32 mm dia Low density polyethylene (LDPE) pipes of pressure rating 6 kgf/sq. cm complete all as specified and directed.
S&F Bib taps, fancy type cast copper alloy with crutch or butterfly handle chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified & directed.
S&F Waste coupling of PTMT (half or full threaded) 40mm bore dia of discharge pipe (mm) (Minimum weight 32mm- 45gms/40mm-60 gms) for sink complete all as specified.
S&F Grating square 150 mm size of PTMT (Minimum weight 100gms) complete all as specified.
Material and labour for 3-layer PP-R polypropylene (random copolymer) concealed pipes and fittings of16mm outer dia, SDR 7.4(PN-16) UV stabilised and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain & brass threaded polypropylene random fittings complete laid in trenches all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm,in hard/dense soil including removing of soil all as specified & directed by Engr-in-charge.
Supply only chain link MS galvanised fencing, any size or type complete all as specified and directed by Engineer - in - Charge.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed.
S&F mild steel screw bolts 12 mm dia of shank (Machine made) with hexagonal or square heads at one end and the screwed the other ends, each screwed end to be fitted with washers and one hexagonal or square but exc 50 mm but N. exc 100 mm long complete all as specified and as directed.
M & L for two coats of synthetic enamel paint over a priming coat of red oxide after preparation of new surfaces of any description, not exc.10cm in width or girth, not otherwise described all as specified & directed by Engr-in-charge.
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases and making good etc in walls complete all as specified and directed for the One light/ Exhaust fan point
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V
Ceiling rose surface Bakelite, 65x50mm ,3 terminals complete all as specified and directed.
S&F Single pole and neutral enclosure with a two pin & earth plug & socket complete with one MCB SP 32A, 240V with plug top
Supply and Laying in trenches or fixing on wall, floor etc LT, PVC/XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts grade cross sectional area of 2core6 sqmm size complete all as specified.
Supply and fixing of exhaust fan 300mm dia sweep, heavy duty, 230 volts. Make: Crompton/ Bajaj/ Havells or Make specified in CA.
S&F CMRI certified LED Flameproof 2x16w/20w LED tube light fitting complete all as specified and as directed Model CG: EXTN2LT8-16/20 or eq Model of Make Specified.
Vastushilp Building Designer
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .