Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.5 LAccepted-AOC D NO 35 14 13 1 R P PETA KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹33.0 L+₹1.3 L (4.02%)Rejected-Finance H NO 8 9 29 ASOKE NAGAR OLD GAJUWAKA VIZAG 530028 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530028 | L2 | Rejected-Finance NON BONAFIED | |
| 3 | L3₹33.2 L+₹1.5 L (4.58%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹33.5 L+₹1.8 L (5.69%)Rejected-Finance D NO 38 22 40 NEAR LAKSHMI NARASHIMA THEATER 104 AREA VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹34.1 L+₹2.4 L (7.60%)Rejected-Finance DOOR NO 58 1 236 6 FLAT NO A 104 SAMPATH ENCLAVE NAD KOTHA ROAD VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
19 Oct 2020, 6:00 pmClosed
Garrison Engineer Utility-II Visakhapatnam
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
MAINTENANCE AND OPERATION OF FIRE FIGHTING PUMP HOUSES FIRE FIGHTING NETWORK DG SET AND CONNECTED ITEMS AT RESIDENTIAL AREA UNDER AOR OF AGE EM NO I OF GE UTILITY II VISAKHAPATNAM
2020_MES_363509_1
8713
Open Tender
Electrical Maintenance Service
Item Rate
330 days
Garrison Engineer Utility-II104 Area Industrial E
CLASS D
11 documents required · 11 mandatory
₹500
Garrison Engineer Utility-II
₹90,000
Yes
31 Oct 2020
21 Sept 2020
20 Oct 2020
21 Sept 2020
19 Oct 2020
5 Oct 2020
Amount
SCHEDULE "A' PART - I
Manning for operation and maintenance, periodical maintenance of Fire Fighting pump Houses including related LT panels and its connected accessories for smooth and trouble free operation complete round the clock in 3 shifts of 08 hours each including sundays and holidays for complete all as specified and directed by Engineer-in-charge. Area: Installations at Jamuna, Gomati and Tapati Buildings at NSB.
Manpower :- One Semi-Skilled Operator per shift. Shift timings:- Ist shift : 0600 Hrs to 1400 Hrs 2 nd shift : 1400 Hrs to 2200 Hrs 3rd shift : 2200 Hrs to 0600 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning for operation and maintenance, periodical maintenance of Fresh water pump house, DG set and pump sets including related LT panels and its connected accessories for smooth and trouble free operation complete round the clock in 3 shifts of 08 hours each including sundays and holidays for complete all as specified and directed by Engineer-in-charge.
Manpower :- One Semi-Skilled Operator per shift. Shift timings:- Ist shift : 0600 Hrs to 1400 Hrs 2 nd shift : 1400 Hrs to 2200 Hrs 3rd shift : 2200 Hrs to 0600 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
List of equipment :- (a) LT panels - 03 Nos (b) 50 Hp pumpsets - 02 Nos (c) Borewells - 04 Nos (d) Main recieving Control valves BPH No.I, keypersonnel Colony, NSB
Manning for operation and maintenance of water supply distribution system in 2 shifts of 08 hours each including sundays and holidays including operation of main and distribution valves, monitoring the water supply pumping from main BPH at pipe line junction to intake of the NSB tanks, keeping of valve chambers neat and clean all the time, rectification of minor defects such as gland leakages etc., and its connected accessories, maintaining of records complete all as specified and directed by Engineer-in -Charge.
Manpower :- One Semi-Skilled Operator per shift. Shift timings:- I st shift - 1600 Hrs to 2400 Hrs II nd shift - 2400 Hrs to 0800 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Manning for operation and maintenace of central sewage treatment plant at Nausena Baugh, Sewage pump house at SHO and at MES Key pers qtrs in 02 shifts of 08 hours each including Sundays & holidays for smooth and trouble free operation, complete all as specified and directed by Engineer-in-charge. The operator is also responsible to run SHO Sewage pump house daily as per regular sheduled time.
Manpower :- One Semi-Skilled Operator per shift. Shift timings:- I st shift - 0500 Hrs to 1300 Hrs II nd shift - 1300 Hrs to 2100 Hrs
Wages for labour ( Basic + Dearness and other allowncess if any as per Latest labour Wages as notified by central / state Govt/Local body, which ever is higher)
Contribution towards Employees provident fund liability ( EPF ) (Employer's contribution as per Government latest rules)
Contribution towards Employees state insurance corporation ( ESIC ) (Employer's contribution as per Government latest rules)
Contribution towards Bonus
Overhead and profit
LWC (Labour welfare cess)
Note:- The rates to be quoted for complete items / subitems above inclusive of all taxes, cess, levies etc., as applicable including GST.
Equipment and plant Details: (i) Raw sewage pump house with 12.5HP/ 20 HP capacity submersible sludge pump sets - 4 Nos. (ii) Aerator tank comprising of 10 HP motor coupled with areator gear box, shaft and areator blades - 4 Set (iii) Clarifier tank comprising of 0.75 HP motor coupled with chained gear box, clarifier baldes etc - 1 Set (iv) Sludge disposal pump house comprising of 12.5 HP submersible pump set - 1 No (v) DG set 100 KVA - 01 No (vi) Sludge drying bed - 1 No (vii) LT panel boards inside of all building including starters, main switches etc., (Viii) clear water pumps 12.5 HP - 2 Nos
Note: for item No.1 to 4 :- (a) The Contractor shall be fully responsible for the custody of all equipments, plants and other connected items inside the STP/ Pump Houses. (b) The contractor shall be responsible for the cleaning inside/ outside of all buildings/installations. (c) Minor repairs/ spares required for the operation of the plants like, nut & bolts, washers, M-seal, insulation tapes, emery papers etc. shall be supplied by the contractor and the cost of the same shall be deemed to be included in the unit rate quoted.
(d) Unauthorized person should not be allowed to enter/ stay inside the STP/ pump house areas. (e) Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Note 1 for SL item No. 1 to 4:- Before commencement of work the contractor shall submit the list of manpower to be employed as per requiste qualifications specified in particular specification for approval of GE duly recomended by Engineer-in- charge.
Note 2 for SL item No. 1 to 4:- 1. Contractor shall quote wages, employers contribution towards EPF liability, contribution towards ESIC, contribution towards bonus, LWC and overhead & profit separately as applicable as per instruction in vogue in respective sub items. 2. The rate quoted for items of outsourcing / Manning shall not be less than minimum wages as notified by Government of India/concerned state Government/Local Body, whichever is higher and also not less than applicable rates for contribution of employer towards EPF, contribution to ESIC, contribution of Bonus and LWC under respective heading / sub-items. In case any quoted rate against the above items / subitems mentioned above which correspond works out to lower than the prevailing minimum rate of wages / subscription / contribution towards EPF / ESIC/ Bonus / LWC the bid will be treated as non bonafide / invalid, shall be disqualified ......
...... and such bids will not be considered for acceptance. In such case, the lowest bidder shall be determined from amongst the valid / bonafide bids only and no claim on this account is entertained. The prevailing rate / wages / contribution shall be as applicable on the bid submission end date. 3. (a) The contractor shall submit the ID Proof, Bank Account No, EPF account number and ESIC account number of Operator / Person Employed. (b) The payment shall not be less than minimum labour wages and payment of labour / employee shall be made through Online Banking like NEFT/ RTGS etc,.
(c) The quoted rate in sub items of wages, EPF, ESIC and Bonus will be released only after producing authenticated Documentary proof of payment as per prevailing rates deposited in the concerned employees account duly signed by contractor and shall be submitted along with RAR / final Bill for payments. 4. Quotations with 'Nil' or "Zero" consideration (overhead and profit) will be considered non bonafide. 5. Any variation in minimum wages, liability of EPF / ESIC / Bonus / LWC / GST shall be adjusted for reimbursement/ Recovery as under:- (i) Variation in minimum wages including other related statutory provisions shall be adjusted in tems of condition 63 of GCC (IAFW-2249). (ii) Variation in percentage/ rate of GST and LWC shall be adjusted as per special conditions here in after which deals with "Reimbursement / Refund on Variation in Taxes Directly Related to Contract Value.
(iii) Rates shall be quoted only upto two digits after decimal. If any rate quoted/ derived by the contractor works out to more than two digits after decimal, then the same shall be rounded off upto two digits after decimal. The rounding off shall be done in accordance with rules for rounding off of Numerical Values in accordance with IS: 02 pf 1960 (Revised 2016) of BIS. 6. The contractor will be required to submit copy of valid labour licence from the labour Commissioner within 15 days of commencement of the work. If the contractor fails to submit the same within this stipulated period the contract shall be liable to be cancelled and the performance Security of the firm shall be forfeited accordingly.
7. (a) In case of requirement, tradesmen provided for one area may be utilised in other areas at the discretion of the department without any extra cost to department as directed by Engineer-in-Charge. (b) Tools & plants shall be provided by contractor. (c) Temporary laying of LTUG cable of any size and any lenth for restoration of supply during break down / other requirement deemed to be included in the above quoted rate. (d) Complaint register and Complaint slip books as per site requirement shall be provided by the contractor and cost of the same is deemed to be included in the quoted rate. (e) All workers employed by the contractor shall be in proper uniform with name plate and other safety wearing items , shoes during the duty as per the electricity rules, which deemed to included in quoted rate.
(f) Departmental equipments of each installation,shall be under safe custody . In case of theft of any item from installation recovery shall be made from the contractor as per direction of Engr-in-charge. (g) Group insurance for the operators shall be made by the contractor. Documents shall be submitted to the department. (h) Rate quoted shall be deemed to include for leave/reserve of staff.
SCHEDULE "A' PART - II
Labour only for cleaning/taking out of silt from sewage sumps, clarifier tank, aerator tank, sludge pumps and sludge bed and getting out and depositing out side the Naval Base area complete all as specified and directed by Engineer-in-charge. Note: Dried sludge/silt shall only be measured and paid. The item rate is inclusive of dewatering the water with suitable pump laid over the sludge.
Material and labour for choke clearing of submersible pump at sewage pump house/ STP including dewatering the sewage sump to bottom level by using diesel driven mobile pump set type/ submersible type, lifting submersible pump with delivery main from bracket at bottom of sewage sump of depth 3 mtr to 5 mtr by using pully & chain block up to floor level, removing all debris from pump casing, removing defective 'D' clamps etc. inspecting impeller, bearing, by passing under current relay, testing the pump, lowering the pump with delivery main through guide wire rope by chain block, setting the pump to bottom bracket, testing the pump complete all as directed.
Note :- (a) The Job to be completed with in 02 hours from choking of pump. (b) The quoted rate is deemed to be include the Tool & Plants required for lifting, inspection, lowering etc., . (c) All safety measures including lighting, safety shoes, safety glows to be provided by contractor.
M&L for lifting of unserviceable submersible motor / pump from sewage well / raw sump etc., of capacity 12.5 HP of any make (Non Clog type) and rewinding of electric motor with same gauge of super enamelled copper wire including varnishing, baking, drying till to get required megger value, replacement of terminal blocks, bearings on both drive end & non-drive end, re-assembling, testing, commissioning and re-erecting the same back in sump safely complete all as directed by Engineer-in-charge.
All as per SI item No.7 above but clarifier motor of capacity 0.75 HP capacity
M/L for pressure testing of existing 150 mm DI/MS fire main system , identifying leakages for rectifications including replacement of gland packing of sluice valves, rubber insertion packing, nut ,bolts etc., of flanged joints/ defective flanges etc., complete for making the system leak proof complete complete all as specified and directed by Engr-in- Charge. Note: (a) The rate quoted deemed to be inclusive of T&P such as air compressor for pressure testing etc., (b) Earthwork, DI/MS pipe & specials required for rectiifcation if any shall be measured and paid under relevant schedule items of BOQ.
Supply, laying and fixing in replacement of the following dia CI pipes with spigot and socket ends centrifugally cast , Class 'B'
200 mm dia.
150 mm dia.
100 mm dia.
80 mm dia.
Supply, laying and fixing in replacement of the following dia DI K9 water supply pipe lines with spigot and socket ends complete
200 mm dia.
150 mm dia.
100 mm dia.
Supply, laying and fixing in replacement of the following dia MS ERW pipes
200 mm bore, thickness not less than 6.30mm
150 mm bore, thickness not less than 5.40mm
100 mm bore, thickness not less than 4.80mm
80 mm bore, thickness not less than 5.40mm
Material and labour for run lead joint for spigot and socket pipes (CI/DI) and fittings to the following sizes complete all as specified and directed by Engr-in-Charge.
80 mm bore.
100 mm bore.
150 mm bore.
200 mm bore.
S&F the following size pipes of 3-layer PP-R (Polypropylene random copolymer) concealed SDR 7.4 Stabilized and antimicrobial fusion welded having thermal stability for hot and cold water supply all PP-R plain and brass threaded polypropylene random fittings fixed to walls, ceilings etc, complete including taking down old unserviceable GI pipe all as specified and directed by Engineer-in-charge:
20 mm (outer dia)
40 mm (outer dia)
50 mm (outer dia)
75 mm (outer dia)
Supply and fix the following sizes of Gun metal gate valves, with iron wheel head, screwed both ends for iron pipe and fixed including cutting the pipe line and taking down old unserviceable valves wherever required complete all as specified and directed.
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply and replace the following sizes of PP-R (Polypropylene random copolymer) gate valve (brass insert) complete all as specified and directed.
25 mm (outer dia)
40 mm (outer dia)
50 mm (outer dia)
Supply and replace existing pressure guage 6" dial, 0-16 Kg rating of existing make including necessary fittings complete all as directed by Engr-in-charge.
Supply and replace existing pressure guage 6" dial, 0-10 Kg rating of existing make including necessary fittings complete all as directed by Engr-in-charge.
Supply and replace the following sizes of CI sluice valves PN 1.6 conforming to IS 14846 flanged end with iron wheel head and stainless steel spindle flanged joints including necessary nuts, bolts, and washers etc., complete all as specified and directed by Engineer -in-charge.
200 mm dia.
150 mm dia.
100 mm dia.
80 mm dia.
Supply and replace the following CI foot valve flanged type with necessary rubber gasket, bolts, nuts and washers complete all specified and directed.
200 mm dia
150 mm dia
100 mm dia
80 mm dia
Supply and fixing or laying in trenches / walls / floors of the following size medium grade GI pipes with all fittings including taking down old unserviceable one all as specified and directed.
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply and fix DOL starter suitable for AC 415 Volts, 50 Hz, 3 Phase pumpset out put at 3 to 10 HP including removing the old unserviceable starter from the panel complete all as directed.
Supply and replacement of fire hydrant landing valve gun metal, type B (Double head outlet) of 63 mm bore conforming to IS-5290 complete all as specified and directed.
Supply and replacement of fire hydrant landing valve gun metal, type A (Single head outlet) of 63 mm bore conforming to IS-5290 complete all as specified and directed.
Supply and replacement of fire brigade inlet connection 4 way including with accessories suitable for 150mm dia pipe complete all as specified and directed.
Supply and replacement canvas pipe 15 metre long hose pipe confirming to IS 636 complete with male and female coupling and drum made out of MS sheet confirming to IS 903 complete all as specified and directed
Supply and replacement of hose reel drum and hose reel of 20mm dia and 30 metre length conforming to IS-5132 including gun metal hose reel cap (shank) suitable for existing fire fighting line complete all as specified and directed.
Repairing/ Servicing of fire hydrant valves of any type fixed to buildings by replacing seat, Neoprene 'O' rings, spring loaded side locks including renewal of necessary bolts/nuts/washers to arrest leakage complete all as directed by Engineer-in-charge.
Supply and replacement of hose boxes of size 800 x 600 x 250 mm with 2 mm thick CRCA sheet, frame made out of 25 x 25 x 5 mm thick MS angle Iron with double door, glazed with 4 mm thick sheet glass and including necessary locking arrragement, preparation and applying two coats of synthetic enamel paint (fire red outside and brilliant white inside) over a coat of zinc chrome primer complete all as specified and directed by Engineer - in - Charge.
M & L for Jungle cleaning by cutting and clearing away all grass vegetation, wild growth, sapling, shrubs, brushwoods, under growth roots, cutting of bushes, tree trunk of girth not execeeding 30 cm, cutting of trunk, portion protuding over ground, filling holes and leveling of ground and removing unserviceable materials to a distance n.exe 50m, compelte all as speicified.
M & L for preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint. complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5 m depth and getting out soft / loose soil for laying of cables, pipes etc, complete all as specified and directed by Engr-in- Charge.
Returning filling in, including spreading levelling watering and well ramming in layers n.exc. 25 cm thick complete all as specified and directed
Removing excavated soil to a distance n.exc. 50 m distance and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed by Engr-in- Charge.
lakshmi Engineering Works
GVR CONSTRUCTIONS
AYYAPPA CONSTRUCTIONS
M/S EVEREST INFRA
SRIESWARI ENTERPRISES
M/s NATIONAL ENGINEERING CONSTRUCTIONS CO
SANTOSH CONSTRUCTIONS
Sri Surya Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .