Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance BHAGWANPUR ROORKEE HARIDWAR | BHAGWANPUR | HARIDWAR | UTTARAKHAND | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
EMD Value
₹57,000
Closing Date
4 Dec 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, Maintenance Division, UJS Pantdeep, Haridwar
Office of The Executive Engineer Maintenance Division, Uttarakhand Jal Sansthan Pantdeep, Haridwar
Supply, Laying, Jointing, Testing and Commissioning of Pipeline for Domestic Household Connection in Changa Majri Water Supply Scheme in Block Bhagwanpur of Haridwar District
2020_UKJS_27695_3
1691/JJM/E-Tender/2020-21 Date-19.11.2020
Open Tender
Civil Works
Item Rate
45 days
Haridwar
As Per NIT
3 documents required · 3 mandatory
₹3,000
EE Maintenance Division Haridwar
₹57,000
Haridwar
5 Dec 2020
25 Nov 2020
5 Dec 2020
25 Nov 2020
4 Dec 2020
25 Nov 2020
1 Dec 2020
Amount
Dismantling of Road
Dismantling of cement concrete pavements by mechanical means using pneumatic tools breaking to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials upto a lead of 1000 m, stacking serviceable and unserviceable materials separately.
Restoration of Road
Construction of Un-reinforced, Cement concrete pavement for restroration of CC Road, (Average thickness 15 to 20cm) in PCC 1:2:4 with 43 grade cement, coarse sand and corse/fine aggregates.
Earthwork
Excavation in soil mixed with single bouldres etc. Requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering, ramming of excavated earth in the trenches.
Providing & Laying of Pipe Line Providing, lowering into trenches with true to alignment, Laying & Jointing of full lenghts of HDPE Pipes of specified grade as per IS:4984-1995 and specifications, with testing of pipe line including supply of jointing materials. PE-63 Grade. Normal Pressure (PN) in 6.0 Kg/Sqcm
90 mm dia pipe
Valves & Chambers Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI/CI Sluice Valves / Scour Valve of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer incharge. C.I. D/F Sluice Valves Confirming to IS: 14846-2000 (Kirloskar or equivalent) PN 1.0
80mm Dia
100mm Dia
Air Valve (Scrwed) 20mm
Constructing masonry Chamber 60x60x75 cm (inside) in brick work in cement mortar 1:4 for fire hydrants/sluice valve, with C.I. surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix, i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3, 12 mm thick, finished with a floating coat of neat cement complete as per standard design.
Constructing masonry Chamber 90x90x100 cm (inside) in brick work in cement mortar 1:4 for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3, 12 mm thick, finished with a floating coat of neat cement complete as per standard design.
Water Connections
Providing and making house service connections from water supply distribution GI pipe line upto water meter chamber inside the property using GI pipe upto 5 metre length including supply and fixing of electrofussion saddle ,brass ferrules elbow, ball valve etc complete with earthwork, road cutting with restoration works
Renovation of Pump House, OHT and Boundary Wall
Providing and laying brick work in cement mortar 1:6 (1 cement : 6 coarse sand) using first class best quality FPS bricks of class designation 100 in super structure upto all heights and levels including scaffolding etc. all complete as directed by engineer in charge.
Providing and laying 18-20 mm average cement plaster mix 1:6 (1cement : 6 fine sand) in two layers on outside brick wall surface including racking joints, curing, scoffolding etc. all complete as per specifications and as directed by Engineer-in-charge.
Providing and laying cement concrete (1:4:8) in foundations, footings, under floors and mass concrete etc. including the cost of centring and shuttering.
Dismantling of existing flooring including stacking of serviceable material and disposal of unserviceable material as per directed by Engineer-in -charge.
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardenermix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the
Oil Bound Distemper: Oil bound washable distemper of approved brand and conforming to IS:428 shall be used. The primer where used as on new work shall be cement primer or distemper primer. The primer coat shall be applied with a brush. The surface shall be finished as uniformly as possible leaving no brush marks. After the primer coat has dried for at least 48 hours, the surface shall be lightly sand papered to make it smooth for receiving the distemper, taking care not to rub out the priming coat. All loose particles shall be dusted off after rubbing. One coat of distemper diluted with thinner, as stipulated by the manufacturer, shall be applied with brushes in horizontal strokes followed immediately by vertical ones which together constitute one coat. The subsequent coats shall be applied in the same way. Two or more coats of distemper shall be applied over the primer coat to obtain an even shade.
Providing and applying 100% heat insulating & thermal resistant, high quality, decorative external Emulsion paint coating of approved make (Asian (Apex), Burger (Weathercaat), Nerolac (Excel) etc.) including a priming coat on the surface and applying by brush two subsequent coats of paint of approved shade, colour, texture & design. The rate shall include erection of scaffolding at all levels, applying three coats at an interval of 4-6 hours between each coat etc.
P/A Enamel The enamel paint shall satisfy in general requirements in specification of oil paints, Enamel paint shall conform to I.S.2933-1975.
Chlorination Pump
Supply of Electronically Controlled, Electrically Actuated, Diaphragm Oerated, Chemical Metering Pump, Wall Mounting Suitable for Delivering upto 6 litres of Chemical Solution / Sodium Hypo Chloride Solution Per Hour Under Maximum Delivery Pressure upto 8 Kg/cm2 & Suction Lift Not Less Than 1.5 Metre With Chemical dosing tank and accessories.
Installation of Electronically Controlled, Electrically Actuated, Diaphragm Operated, Chemical Metering Pump With All Accessories at Site of Work. Injector and NRV with PVC pipes etc. 200 ltr. Capacity PVC tank, Starter cum panel, Single phase automatic stabilizer, Chlorine testing kit etc.
Servo Voltage Stabalizer Input Voltage 330-460 Volts (Phase to Phase) Capacity - 125 Kva
Supply, Installation, Testing and commissioning of 3-Phase Digital rolling contact servo voltage stabalizer suitable for unbalanced voltage and unbalanced load including supply of proper size cable & lugs also fixing of proper size copper lugs on input and output cabels on both ends at differnt sits on Turn key basis including five year free maintaince.
SITC of Autometic phase sequence corrector unit for 75 amp load, 440 volt, 3-phase AC supply
M/S VISHNU RAGHAV CONSTRUCTION
4 Dimensions
M/s S.S. Construction
Geetaram Saini
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .