Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.3 L+₹2.3 L (78.6%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹7.5 L+₹4.6 L (154.2%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹6.7 L
EMD Value
₹16,836
Closing Date
7 Sept 2023, 4:00 pmClosed
Chief Executive Officer
Chief Executive Officer Park Centre, Technopark Phase I Campus
PERIODIC MONITORING OF DRINKING WATER, STACK, EFFLUENT, AMBIENT AIR AND NOISE LEVEL IN TECHNOPARK PHASE I, PHASE III AND PHASE IV CAMPUSES
2023_ETPK_598522_1
ETPK/PH-I/2023-24/AT-190
Open Tender
Miscellaneous Works
Item Rate
720 days
Technopark Phase I, Phase III and Phase IV Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,589
₹16,836
21 Nov 2023
24 Aug 2023
8 Sept 2023
24 Aug 2023
7 Sept 2023
25 Aug 2023
25 Aug 2023 - 5 Sept 2023
Amount
TESTING OF FOLLOWING SAMPLES IN PHASE I CAMPUS INCLUDING ALL ASSOCIATED COSTS
Ambient Air (A total of 2 samples with following parameters have to be taken per month): Parameter to be tested are: Particulate Matter (PM10) Particulate Matter (PM2.5) Sulphur Dioxide(SO2) Nitrogen Dioxide(NO2) Carbon monoxide (CO) Lead (as Pb) Arsenic (as As) Nickel (as Ni) Ammonia (as NH3) Ozone (as O3) Benzene (as C6H6) Benzo (a) pyrene (as BaP)
Stack Emission (A total of 5 samples with following parameters have to be taken per month): Parameter to be tested are: Temperature Velocity of Gas Discharged Volume of Gas Discharged Particulate Matter Sulphur Dioxide
Noise Level (A total of 2 samples have to be taken per month):
Drinking water (A total of 8 samples with following parameters have to be taken per month): Parameter to be tested are: Colour Odour Turbidity pH Total Dissolved Solids Total Hardness (as CaCO3) Calcium (as Ca) Magnesium (as Mg) Chloride (as Cl) Total Alkalinity (as CaCO3) Iron (as Fe) Sulphate (as SO4) Nitrate (as NO3) Residual Free Chlorine Total Coliform Bacteria E coli
River/Canal water (A total of 2 samples with following parameters have to be taken per month): Parameter to be tested are: pH Total Suspended Solids Biochemical Oxygen Demand (3 days at 27 OC) Chemical Oxygen Demand Oil & Grease
Sewage water (A total of 3 samples with following parameters have to be taken per month): Parameter to be tested are: pH Total Suspended Solids Biochemical Oxygen Demand (3 days at 27 OC) Chemical Oxygen Demand Oil & Grease
TESTING OF FOLLOWING SAMPLES IN PHASE III CAMPUS INCLUDING ALL ASSOCIATED COSTS
Ambient Air (A total of 1 samples with following parameters have to be taken month): Parameter to be tested are: Particulate Matter (PM10) Particulate Matter (PM2.5) Sulphur Dioxide(SO2) Nitrogen Dioxide(NO2) Carbon monoxide (CO) Lead (as Pb) Arsenic (as As) Nickel (as Ni) Ammonia (as NH3) Ozone (as O3) Benzene (as C6H6) Benzo (a) pyrene (as BaP)
Stack Emission (A total of 1 samples with following parameters have to be taken per month): Parameter to be tested are: Temperature Velocity of Gas Discharged Volume of Gas Discharged Particulate Matter Sulphur Dioxide
Noise Level (A total of 1 samples have to be taken per month):
Drinking water (A total of 7 samples with following parameters have to be taken per month): Parameter to be tested are: Colour Odour Turbidity pH Total Dissolved Solids Total Hardness (as CaCO3) Calcium (as Ca) Magnesium (as Mg) Chloride (as Cl) Total Alkalinity (as CaCO3) Iron (as Fe) Sulphate (as SO4) Nitrate (as NO3) Residual Free Chlorine Total Coliform Bacteria E coli
River/Canal water (A total of 2 samples with following parameters have to be taken per month): Parameter to be tested are: pH Total Suspended Solids Biochemical Oxygen Demand (3 days at 27 OC) Chemical Oxygen Demand Oil & Grease
Sewage water (A total of 2 samples have to be taken for each of the below item, per month): Parameter to be tested are: pH Total Suspended Solids Biochemical Oxygen Demand (3 days at 27 OC) Chemical Oxygen Demand Oil & Grease
TESTING OF FOLLOWING SAMPLES IN PHASE IV CAMPUS INCLUDING ALL ASSOCIATED COSTS
Ambient Air (A total of 1 samples have to be taken for each of the below item, per month): Parameter to be tested are: Particulate Matter (PM10) Particulate Matter (PM2.5) Sulphur Dioxide(SO2) Nitrogen Dioxide(NO2) Carbon monoxide (CO) Lead (as Pb) Arsenic (as As) Nickel (as Ni) Ammonia (as NH3) Ozone (as O3) Benzene (as C6H6) Benzo (a) pyrene (as BaP)
Stack Emission (A total of 1 samples with following parameters have to be taken per month): Parameter to be tested are: Temperature Velocity of Gas Discharged Volume of Gas Discharged Particulate Matter Sulphur Dioxide
Noise Level (A total of 1 samples have to be taken per month):
Drinking water (A total of 2 samples with following parameters have to be taken per month): Parameter to be tested are: Colour Odour Turbidity pH Total Dissolved Solids Total Hardness (as CaCO3) Calcium (as Ca) Magnesium (as Mg) Chloride (as Cl) Total Alkalinity (as CaCO3) Iron (as Fe) Sulphate (as SO4) Nitrate (as NO3) Residual Free Chlorine Total Coliform Bacteria E coli
Sewage water (A total of 1 samples with following parameters have to be taken month): Parameter to be tested are: pH Total Suspended Solids Biochemical Oxygen Demand (3 days at 27 OC) Chemical Oxygen Demand Oil & Grease
Standards Environmental and Analytical Laboratories
Envirodesigns Eco Labs
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_888423.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .